Defence Statutory Bodies & Commissions/Committees Closing in 12 days TDR #57429074

Tender For Construction Of Adm Block For Weu At Rajouri Under Ge 862 Ews

Issued by Statutory Bodies & Commissions/Committees · Rajouri, Jammu and Kashmir
Tender Value
4.98 Crore
Estimated cost
Bid Submission
28 Oct 2026
12 days left
EMD
5.73 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rajouri → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Adm Block For Weu At Rajouri Under Ge 862 Ews

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 10-Oct-2026 CorrNo01 Date 28-Oct-2026

BOQ

Name of Work:- CONSTRUCTION OF ADM BLOCK FOR WEU AT RAJOURI UNDER GE 862 EWS
Sl. No. Item Description
1Sch 'A' Part-I (Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only.
2Construction of building block for Adm block for WEU complete all as shown on drawings and as specified.
3Construction of building block for covered accn for vehicle and ancellaries (single bay) including open platform, dwarf wall, toe wall and ramp/apron, complete all as shown on drawings and as specified.
4Total Amount of Sch 'A' Part - II (Site Clearance and Development Work)
5Total Amount of Sch 'A' Part - III (Sec-I) (Internal Water Supply Work)
6Total Amount of Sch 'A' Part - IV (Sec-I) (Internal Electric Supply Work)
7Total Amount of Sch 'A' Part - V (Plumbing Work)
8Total Amount of Sch 'A' Part - VI (Area Drainage Work)
9Total Amount of Sch 'A' Part - VII (Sec-I) (Protective Work)
10Total Amount of Sch 'A' Part - VIII (Sec-I) (Sewage Disposal Work)
11Total Amount of Sch 'A' Part - IX (Road, Path and Culver Work)
12Total Amount of Sch 'A' Part -X (Sec-I) (External Water Supply Work)
13Total Amount of Sch 'A' Part -XI (Sec-I) (External Electric Supply Work)
14Total Amount of Sch 'A' Part -XII (Dismantling/Demolition Work)
15Sch 'A' Part - III (Sec-II) (Internal Water Supply) Note: This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only.
16Two way bib cock with wall flange quarter turn (low-flow) 16mm dia complete all as specified and directed
1715mm bore push cock for urinal for iron pipe and fixed (PRS-CHR-073) (1.5 LPM) complete all as specified and directed
18Angular stop cock 15mm bore for pipe with wall flange chromium plated stop valves complete all as specified and directed.
19Sch 'A' Part-IV (Sec-II) (Internal Electric Supply Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only.
20Point wiring complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20mm dia medium grade (MMS) and all accessories are concealed in walls / roofs / floors / ceiling etc; including modular metal flush box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick including modular top cover plate as per numbers of switch modules for fixing of modular switches, sockets, fan regulators, red colour indicator, blank plates etc. as approved colours and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- Note No1: All necessary accessories such as modular steel box, top cover plate, blank plate, screws, washers and all modular electrical fixtures are to be used of same make/brand only. Note No 2: Any cutting /leaving /forming holes, chases etc., in walls, floors and ceiling as required and making good the same, shall be deemded to be included in lump sum Sch 'A' Part-I as per para 10(b) in Sch 'A' BOQ Notes.
21All as per Srl item No. 14.01 here-in-before above but one light/fan/exhaust fan/bell buzzer point controlled by one switch
22All as per Srl item No. 14.01 here-in-before above but one additional point controlled by on the same switch circuit.
23All as per Srl item No. 14.01 here-in-before above but one 6 Amp, socket outlet on the same board with other switch
24All as per Srl item No. 14.01 here-in-before above but one 6 Amp, socket outlet, independent board
25All as per Srl item No. 14.01 here-in-before above but one 16 Amp, socket outlet, independent board with 2.5mm2 size cable.
26All as per Srl item No. 14.01 here-in-before above but one 20 Amp, socket outlet, independent board with 4mm2 size cable.
27MCB, Single pole & neutral, 240 volt, 25/32 A, 10KA rating, \\"C\\" curve, complete all specified and directed.
28Modular switch, 3 pin, 25/32 A socket, complete all as specified.
29Sheet metal enclosure DB, vertical triple pole & neutral, 8 way double door (IP-43) made out of powder coated CRCA mild steel sheet 1.6mm thick, suitable for MCCB upto 160 A as incommer and SP/TP MCBs as including with 250 A rated copper busbar for each phase with neutral, earthing and din rail, dust and vermin proof, suitable for fixing flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification including taking down complete all as specified and directed.
30MCCB, 4pole, 415V, 25KA, 25 Hz with TMD, single frame size upto 250A.
31Sub main wiring with two run of single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia or above required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmm as earth continuity conductor connected to commen earth dolly complete all as specified and directed.Note: - Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only.Note No 2: Any cutting /leaving /forming holes, chases etc., in walls, floors and ceiling as required and making good the same, shall be deemded to be included in lump sum Sch 'A' Part-I as per para 10(b) in Sch 'A' BOQ Notes.
32Sub main wiring with four run of single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia or above required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 sqmm as earth continuity conductor connected to commen earth dolly complete all as specified and directed.Note: - Four run of 10 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only.Note No 2: Any cutting /leaving /forming holes, chases etc., in walls, floors and ceiling as required and making good the same, shall be deemded to be included in lump sum Sch 'A' Part-I as per para 10(b) in Sch 'A' BOQ Notes.
33Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size (32x6)mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron (40x40x5)mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh, GI medium grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed. Note: - (i) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction.(ii) Supply and fix of the earth Pit chamber board for all earthing fixe in this project of 3.15mm thick mild steel sheet of size min 45cm x 30cm fixed with 12mm thick MS rod two Nos up to 90cm height by nut/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters min 6cm height i.e; earth Pit No. location, earthinc test value and date and other letters complete all as specified and directed by Engr- in-Charge.
34Galvanised iron strip 32mm x 6mm as earth lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc; complete all as specified and directed.
35LED batten suitable for indoor application 20W, 4 feet length, 65KA wall mounted with polycarbonate housing, end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified.
3610W 3 star (EEL) T-shape lamp capable delivering 1000 lumen having luminous efficacy of >100lm/W, starting time < 0.5s, CRI>80, CCT 6500K, PF>0.9, input voltage range 140-270V, input frequency 50-60 Hz and B22 socket complete all as specified and directed.
377W LED, 1 feet mirror light suitable for wall mounting & 220-240V, 50Hz mains voltage with built in LED & driver, luminous efficacy of > 90, power rating ≤ 8W, including IP20 protection as well as electrical connection with 3 core 1.0mm2 PVC insulated copper conductor unarmoured cable to the fixture complete all as specified and directed.
3812W surface mounted round shape, 7 inch, LED downlight capable of delivering 1200 lumen having minimum luminous efficiency> 100 lumen/W, CCT 6500K, CRI>80, high quality polycarbonate diffuser, input voltage range 140-270V, input frequency 50-60Hz, including electrical connection complete all as specified and directed.
39LED street light fitting 25 Watt, 230 V, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, complete all as specified and directed.
40Supply, installation, testing and commissioning of feeder piller box outdoor type fabicrated of 3.15mm thick, CRCA sheet dust and vermin proof powder coated double door type independent cabin including locking arrangement for each MCCB;s, bus bar chamber enclosed complete suitable for operating on 415 volt, 50Hz, AC supply internally wired with copper conductor/strip of adequate size from main incoming MCCB to bus bar and bus bar to outgoing MCCB/MCBs, having lags 45cm made out of 65mmx65mmx6mm angle iron grouted on brick masonary platform upto 30cm, brick masonary platfom should be 60cm above the ground level, comprising the following:-(i) MCCB 160 amps, FP, 35KA, 415volts, 50Hz-01 No. (adjustable type)(ii) MCCB, 60 amps, FP, 25KA, 415volts, 50Hz-2 No.(iii) MCB, 40amps, SPN, 10KA, 240 volts, 50Hz-1No.(iv) Digital voltmeter, 415volts with VSS-01 set, digital ammeter, 250amp with CTs & ASS-01-01 set(v) LED phase indication lamps RYB-01 set(vi) Aluminium bus bar TPN 400 amps rating-01 set
41Sch 'A' Part-VII (Sec-II) (Protective Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only.
42Earth work in excavation by mechanical means Hydraulic excavator)/ in foundation trenches or drains (exceeding 1.5 m in width or 10sqm on plan), including dressing of sides and ramming of bottoms, lift upto 3m, including getting out in all kind of soil (the excavated soil) and disposal of surplus excavated soil, within a lead of 50m complete all as specified and directed.Note:- Contractor may at his discretion use any means for excavation and width required at site. However payment shall be made for authorized width only as defined in preamble para 3.2.3 to section 3 of MES SSR Part-II.
433mm dia galvanised steel wire, 150x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling, complete all as specified and directed.
44Boulders/gravel pitching as in inverted filter backside of retaining wall in two layer vertical 1st layer 300mm thick of 40mm to 100mm gravel and 2 layer 150mm thick of 20mm to 40mm (hand packed tightly) complete all as specified and directed.
45Filling of coarse sand behind the retaining wall as an inverted filter media duly compacted complete all as specified and directed.
46Pre moulded bitumen impregnated fiberboard (20mm thick) in expantion joints including cutting to shape fixing in position with adhasive/cement and finishing the surface complete all as specified and directed.
47Sch 'A' Part - VIII (Sec-II) (Sewage Disposal Work) Note: This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only.
48LLDPE septic tank designed to carry sewage and sludge water, comprising earth work , excavation, returning filling, disposal of surplus spoils to a distance not exceeding 50 mtr from starting point in any type of soil, PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation, 200mm thick, vent shaft, connections etc.for 30 users (4000 liter capacity) including all fittings, fixtures, testing on completion complete all as specified.
49Construction of soakage well (Brick construction) 2.4m dia and 3.00m deep below inlet pipe level (depth from inlet pipe to ground level 45cm), complete all as specified and shown on drg No. CEUZ/TD-1585/2021 sheet 1/4 to 4/4.
50Sch 'A' Part - X (Sec-II) (External Water Supply Work) Note: This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only.
51Water pressure gauge, pressure upto 7kg, suitable for non clog vertical motor pump 1 HP complete all as specified and directed.
52Construction of Valve pit of size (120x6120x120)cm (Internal dimensions) using PCC (1:4:8) type D-2, using 40mm graded crushed stone aggregate for foundation, 10cm thick and 100mm off sets on all sides, 230mm thick brick masonary walls built in cement mortar (1:6), 15mm thick rendering all around the masonry work in cement (1:6), for internal and up to 15cm below GL for external surfaces of walls, 50mm thick PCC (1:2:4) type B-1 using with 20mm graded crushed stone aggregate including necessary form work for grouting including 3.15mm thick, MS top sheet cover double door with locking arrangement welded to MS frame made out of (50x60x6)mm angle iron frame fixed with hold fasts including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation in any kind of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as specified and shown on drawing.
53Sch 'A' Part - XI (Sec-II) (External Electric Supply Work) Note: This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only.
54Earthing complete with galvanized steel pipe electrode 40mm bore, medium grade, 2.5m length buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including medium grade GI protection pipe 15mm dia up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.Note:(i) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction.(ii) Supply and fix of the earth Pit chamber board for all earthing fixe in this project of 3.15mm thick mild steel sheet of size min 45cm x 30cm fixed with 12mm thick MS rod two Nos up to 90cm height by nut/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters min 6cm height i.e; earth Pit No. location, earthinc test value and date and other letters complete all as specified and directed by Engr- in-Charge.
55Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size (25x4)mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) reinforced with TMT steel bars 8mm dia @150mm c/c both ways with suitable handle and angle iron (40x40x5)mm frame, GI medium grade watering pipe 15mm dia and funnel with wire mesh, GI light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed. Note:- (i) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction.(ii) Supply and fix of the earth Pit chamber board for all earthing fixe in this project of 3.15mm thick mild steel sheet of size min 45cm x 30cm fixed with 12mm thick MS rod two Nos up to 90cm height by nut/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters min 6cm height i.e; earth Pit No. location, earthinc test value and date and other letters complete all as specified and directed by Engr- in-Charge.
56Supply , installation, testing & commissioning of transformer of capacity 100 KVA step down outdoor type level - III, copper wounded, 11/0.433 KV (at no load) AC 3 phase, vector group Dyn 11, 50HZ on secondary side double wound oil immersed naturally air cooled with external cooling tubes /radiator , delta connected as on primary and star connected with netural brought out on secondary side and having tapping at -2.5% to +7.5% in steps of 2.5% to be changed by external hand operated self position off load tap change switch. Also provision shall be made for locking the taping switch handle in position. The maximum temperature rise shoud not exceed 35 degree centigrade on top of oil when measured on thermometer and 40 degree centigrade in HV/ LV winding when measured by the resistance method after continuous full load run in ambient temperature the transformer shall confirming to IS 1180-2014 transformer lossess shall be as per latest ammendment No IV as per IS 1180 part - I 2014 and comprising of following accessories complete all as specified and as directed. (Contd.../)
57a) 03 No porcelains HV bushing with arching horns on HV side suitable for 11 KV complete with bushing rods nuts.b) 01 No cable end box on LV secondry side consisting of 05 No porcelain bushing (One No neutral earth, One No Neutral and 3 No for phase connected bushing) with bushing rods and nuts washers and cable glands suitable for reception of out 3.5 core 400 Sqmm cable 3 runs, LT 1100 V grade XLPE insulated heavy duty including gland joint complete. c) Oil conservator with filter type drain valve and oil level guage.d) Dehydrating breather with first filling of dehydrating agent e) Explosive vent.f) THERMOMETER pocket including temperature gaugeg) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI strips.h) One No thermometer dail type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature gauge : Max reading painted terminal.i) Rating plate with terminal plate.j) Oil level guage.k) Oil drain filter valve.l) Oil filling hole on top cover with plug.m) Air release valve/plug.n) 4 Nos plain solid cast steel detachable rollers. o) First fill of tranformer oil conforming to relevent ISI and tested upto 60 KV dielectric strength.p) Two No lifting hook at side of transformerNote : Transformer must be as per Energy efficiency Level-3 of IS: 1180:2014 with amendment No. 4.
58LED street light fitting 70 Watt, 230 V, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, complete all as specified and directed.
59Junction box of size 250mm x 250mm x 115mm with aluminium busbar 4 No including connection and comprising of MCB, SP 6 amps for controlling & providing GI clamps, nuts, bolts etc; suitable for fixing on PCC pole/wall/steel tubular pole etc; complete all as specified and directed.
60Sch 'A' Part - XIII (Special items & Misc Items of work) Note: This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only.
61Ceiling fan complete with blades, down rods with modular fan step regulator, 120W, 2 module and accessories, 230V, 1200mm sweep, min air delivery 210CFM, with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC), complete all as specified and directed.
62Supply, installation, commissioning and testing of inverter type split air conditioner of 2.0 TR (6000) Kcal/Hr) capacity, complete with cordless remote control unit and with minimum 5 Star rating. Indoor unit Hi wall mounted type, suitable for 230 Volt, 50 Hz, single phase AC supply and capable for performing the function as cooling/heating, dehumidifying, air circulating and filtering. The air conditioners shall be complete with automatic temperature control, cut-in, cut-out for variable temperature range 16 to 30 degree C, complete all as specified and directed.
63Supply, installation, commissioning and testing of inverter type split air conditioner of 1.5 TR (6000) Kcal/Hr) capacity, complete with cordless remote control unit and with minimum 5 Star rating. Indoor unit Hi wall mounted type, suitable for 230 Volt, 50 Hz, single phase AC supply and capable for performing the function as cooling/heating, dehumidifying, air circulating and filtering. The air conditioners shall be complete with automatic temperature control, cut-in, cut-out for variable temperature range 16 to 30 degree C, complete all as specified and directed.
64Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type, wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 20 volts with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed.
65Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 20 volts with accuracy of ± 2.5% and of capacity 4 KVA, complete all as specified and directed.
66Supply, installation and comminssioning of refrigerator, (single phase) Single door BEE 5 star rated frost free, digital inverter with hermetically sealed compressor of min capacity 195 litres suitable to use on 230 volt, AC supply complete all as specified and directed.
67Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 20 volts with accuracy of ± 2.5% and of capacity 0.5 KVA, complete all as specified and directed.
68Supply, installation, testing and commissioning of water cooler partially stainless steel, electric driven single phase having approx storage and nominal cooling capacity of 40 litres and storage capacity 80 litres, complete all as specified and directed.
69Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type, wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 20 volts with accuracy of ± 2.5% and of capacity 2 KVA, complete all as specified and directed.
70Street light bracket made out of 40mm dia, medium grade GI pipe of 1.5m length, both end hole for fixing street light/security light fitting on Steel tubular pole including MS clamps, back plates fabricated from structural steel section 50mmx4mm, including nuts, bolts, washers, welding cold or hot, drilling of holes for bolts, in any shape or size including two coats of aluminium paint over a coat of red oxide primer after preperation of steel surfaces, complete all as specified and directed.
71Deduction to be made from BOQ for Sch 'A' Part -XIV (Schedule of credit) during AOC.Note: Tenderers shall not quote for this schedule. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57429074
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 4.98 Crore
LAST DATE 28-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Construction Of Adm Block For Weu At Rajouri Under Ge 862 Ews
Basic Detail
Tender No 87955-A/E8
Bidding Type Tender
Location
City Rajouri
State Jammu and Kashmir
Key Dates
Publish Date 10 Oct 2026
Submission Date 28 Oct 2026
Open Date 30 Oct 2026
Finance
Tender Value 4.98 Crore
Tender Fee 2000
EMD 5.73 Lakhs
Exemption Available
Document List
119_merged_compressed.pdf
b43e5ce9-2619-451a-a5fb-11b558672870.html
BOQ_883557.xls
Drg1_compressed.pdf
Drg2_compressed.pdf
Drg3_compressed.pdf
Drg4_compressed.pdf
TD-septic.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 28, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 12 days
Oct 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Oct 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
pdf

119_merged_compressed.pdf

html

b43e5ce9-2619-451a-a5fb-11b558672870.html

xls

BOQ_883557.xls

pdf

Drg1_compressed.pdf

pdf

Drg2_compressed.pdf

pdf

Drg3_compressed.pdf

pdf

Drg4_compressed.pdf

pdf

TD-septic.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender