Tender For Provn Of Heat Retardent Paint And Addn/ Altn To Passage, Guard Room Of Ncs And Provn Of Wall Panelling, False Ceiling, Tiling And Internal Wiring Of Exam Room And Maths Lab And Provn Of Awning To Certain Locations Of Ncs At Chanakyapuri Un
Tender Overview
Project Description
Tender for Provn Of Heat Retardent Paint And Addn/ Altn To Passage, Guard Room Of Ncs And Provn Of Wall Panelling, False Ceiling, Tiling And Internal Wiring Of Exam Room And Maths Lab And Provn Of Awning To Certain Locations Of Ncs At Chanakyapuri Under Ge New Delhi
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GE NEW DELHI Name of Work: PROVN OF HEAT RETARDENT PAINT AND ADDN/ ALTN TO PASSAGE, GUARD ROOM OF NCS AND PROVN OF WALL PANELLING, FALSE CEILING, TILING AND INTERNAL WIRING OF EXAM ROOM AND MATHS LAB AND PROVN OF AWNING TO CERTAIN LOCATIONS OF NCS AT CHANAKYAPURI UNDER GE NEW DELHI Contract No: GE/ND-52/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | B&R PORTION:Taking up or down 15mm dia bore of galvanised Iron steel tubing and connections including cleaning for refixing or removing from site complete all as specified and directed. |
| 3 | Taking up or down 20 mm dia bore of galvanised Iron steel tubing and connections including cleaning for refixing or removing from site complete all as specified and directed. |
| 4 | Supplying and laying of 20 mm dia CPVC pipes SDR 11 fittings on walls / ceiling or laying in floors including cement solvent and all fitting complete all as specified and directed. |
| 5 | Supplying and laying of 25 mm dia CPVC pipes SDR 11 fittings on walls / ceiling or laying in floors including cement solvent and all fitting complete all as specified and directed. |
| 6 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 7 | M&L for Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 8 | Taking down cement plaster on brick walls, raking out joints locking for key, scrubbing down with water etc complete all as specified and directed. |
| 9 | M&L for 15 mm thick cement plaster in CM (1:6) on fair face of brick or concrete surfaces of walls finished even and smooth without using extra cement complete all as specified and directed. |
| 10 | M&L for Preparation of new plastered or un-plastered surface of walls and applying two coats of oil bound distemper using roller brush on walls over a coat of primer and over incl one coat of 1.50mm thick putty complete all as specified and directed. |
| 11 | M&L for complete removal of existing treatment from old surfaces of wall scrapping by mechanical means and applying two coats of oil bound distemper using roller brush over a coat of primer and over incl one coat of Birla putty complete all as specified and directed. |
| 12 | M&L for complete removal of existing treatment from old surfaces of ceiling scrapping by mechanical means and applying two coats of oil bound distemper using roller brush, over a coat of primer and over incl one coat of 1.50mm thick putty complete all as specified and directed. |
| 13 | M&L for prepration of brick or concrete surface clean and free of dust,oil,paint,loose particals,dimoldimg agents,organic products etc and applying 15mm thick exter surface treatement as in 2 layer [10mm base layer and 5mm final layer] as under:- [A]base coat [10mm thick]:-Apply in 1 or more coat to achieve average 10mm thick of water vapour per meable mortar,unofin classic base coats render or equivalent brand of make sikka,fosroc for weather resistant and high performance facades with csiv commpressive strength,flexural strength > 2.5 N/mm2 and water vapour permibility < 15micron as per EN 998-1 and finished even and rough marks to anchore with final layer it should be includes the rain forcement of weaker points / areas [change in the subtract material,slab,pillars/rollar blind boxes around the opening/ windows,doors etc] with fibre glass mess to avoide cracks as per manufacturers recomndation or as per direction of engr-in-charge [B] Final layer [5mm thick]:-Finishing with rainwater resistantand water vapour permeable rendring mortar,UNOFIN PRIME COARSE render or equivalent brand of make sikka,fosroc for weather resistant and decorative facades with CSII commpressive strength,flexural strength > 2.5 N/mm2 and water absoptionas W2 (C<0.2Kg/m2.min 0.5) water vapour permibility < 15micron as per EN 998-1 all as per manufacturers recomndation or as per direction of engr-in-charge Note: 1. Size and specification of fibreglass mesh shall be as per manufacturersrecommendations. 2. Contractor shall be provide authorised applicatore and no exter cost shall be provide in this account. |
| 14 | M&L for 1 to 1.5mm thick of one coat of Texture JK Maxx Rustic tex finish or equivalent brand make of Asian paints or Berger on level surface of internal staircase walls, landings, beams, columns, etc. as per design or pattern directed including necessary scaffolding/ladders with all safety accessories complete all as specified as directed by Engineer in charge. |
| 15 | S&F in repair angle valve (one way) 15 mm bore cast copper alloy fancy type, cromium plated with cupcomplete all as specified and directed.Make- Jaquar CAT Part No OPP-CHR-15053PM/ Cera Cat Part No F2002201 or Equivelant in kohler |
| 16 | S&F in repair chromium plated brass two way bib tap fancy type screwed down , screwed for iron pipe or for brass ferrule 15 mm bore complete all as specified and directed.Make: Jaquar CAT Part No CON-CHR-041KN , Cera Cat Part No F2002163 or Equivelant in kohler/ Cera |
| 17 | S&F in repair 15mm bore dia Stainless steel finish quarter turn central hole basin mixer round spout with popup Waste assemly with 10mm dia , 450 mm long copper pipes complete all as specified and directed by Engr-in-Charge. Make : Jaquar CAT Part No CQT-CHR-23167B, Cera Cat Part No F2002461 or Equivelant in kohler/ Cera |
| 18 | S&F in repair Robe Hook CP finish complete in all respect as specified and directed by Engr-in-Charge. Make : Asian paints or equivalent in Jaquar / Kohler |
| 19 | S&F in repair brass chromium plated Health Faucet including flexible pipe of 15 mm bore and 1.20M long with and including 15 mm bore complete all as specified and directed.Make: Jaguar Cat Part No ALD-573/ Hindware cat Part No SI-13081 SI-14001 and CERA Cat Part No. : F8030105AB |
| 20 | S&F in repair brass chromium plated toilet paper holder, complete all as specified and directed.Make: Jaguar Cat Part No CAN-1151N/ CERA Cat Part No F5007110/ Hindware cat Part No F880003CP |
| 21 | S&F in repair fancy type stainless steel towel rack size 600mm X 300mm including a pair of brass bracket complete all as specified and directed.Make: CERA cat part No F5003101/ Prayag Cat Part No BA12/ Somany Cat Part No 272130330101 |
| 22 | S&F in repair Vitreous China wash down water closet pan single piece syphonic action , white fixed in repair, including soft close sheet cover of closed pattern with flat bottom complete all as specified and directed.Make: Hindware Cat part No/ Cera Cat Part No S1013178VS/ Jaguar Cat Part No SLS-WHT-6851S110PP |
| 23 | S&F in repairs vitreous china wash hand basin counter/table top type of size 495mmX395mmx150mm (Jaquar CAT Part No JDS-WHT-25909/ Cera CAT Part No S2020163 or Equivelant in Kohler) in 18 mm thick granite (of any type) machine cut as in platforms, bedded and jointed with grey cement slurry and pointed with white cement with admixture of of pigment to match the shade of granite stone, including 32mm bore dia CP waste coupling, bottle trap (Jaguar CAT Part No ALD-SSF-769L250X190/ CERA Cat Part No F8060301 or equivalent) and all required fittings complete all as specified and directed. |
| 24 | S&F in repair fancy type brass chromium plated soap dish, complete all as specified and directed.Make: CERA cat part No F5004106/ Prayag Cat Part No BA15/ Somany Cat Part No 27213033051 |
| 25 | S&F in repair PVC connections 15mm size with PTMT steel nuts of length 450 mm complete all as specified and directed. |
| 26 | S&F in repair 6 mm thick looking mirror bevelled edge of selected quality glass of required shape and size with French Gold finish 1st class hard wood desiner beading frame made around, mounted on 6 mm thick commercial ply or AC building board fitted to wooden plug with Gold finish brass screws complete all as specified and directed. |
| 27 | S&F in repairs Glass Shelf assembly Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed. |
| 28 | S&F in repairs corner shelf 304 x 304 mm size with 5mm thick toughened glass complete all as specified and directed.Make : Jaquar / Kohler/ Hindware/ Cera |
| 29 | S&F in repairs Drappery curtain rods decorative type stainless steel 304 Grade, 25mm nominal dia and having wall thickness 1.40 mm of approved quality/make including provision of two number decorative brackets fixed in brick/concrete wall, Two number knob on both ends of curtain rods ( The length of each curtain rod will be 1.00m to 2.50m long) complete all as specified and directed. |
| 30 | S&F in repair Ceramic Hindware Rhine - 96008 Italian collection urinals with fixing accessories set of size (69 x 34.5 x 28 Cm) Pedestal Basin (Star white) bowl type, of make complete including providing and fixing plugs, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; incl S&F of electric operated urinal sensor flushing part code 500963 and incl required accessories for making connection with urinal, brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed.MAKE : Hindware Cat Part No Rhine - 96008, part code 500963 or equivalent in Jaquar / Kohler |
| 31 | Dismantling floor, hearth or wall tiles including cement mortar bedding(but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 32 | M&L for Non skid joint less coloured ceramic tiles 7-8mm thick (Square / Rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.Make : Johnson / Kajaria / Somany |
| 33 | M&L for Double Charged full body vitrified any shade and matt finish/ glossy finish tiles 10 mm thick (rectangular) tile of size 1200mmx600mm in floors set and jointed in neat cement slurry and pointed with white or coloured cement laid over 15 mm thick Screed bed or bedding layer of cement mortar 1:4 (Size,Colour and pattern of tile as approved by EIC and work to be execute through skilled labour) complete all as specified and directed.Make : Johnson / Kajaria / Somany |
| 34 | All as per item No 32.00 above but in skirting only over and including 10mm thick rendering in CM 1:3 complete all as specified and directed. |
| 35 | M&L for joint free glazed ceramic coloured tiles in vertical surface 350 x 250 x 7 mm or 450 x 350 x 7 mm thick with matching highlighter over and including 10 mm thick rendering in cement mortar 1:4 set and jointed in neat cement slurry and pointed in white or colour cement to match coloured tiles (Design/colour of tiles will be approved by GE) complete all as specified and directed.Make : Johnson / Kajaria / Somany |
| 36 | Demolition of stone slabs and tiles of any description or thickness in floors/walls, aprons etc laid bedded and pointed in any mortar complete all as specified and directed. |
| 37 | M&L for 10-12 mm thick heavy duty parking tiles 400 x 400 mm of any colour and pattern decided by Engr-In-Chargeas in pavings laid over 20 mm thick screed bed 1:4 set jointed with cement slurry mixed with pigments to match the shade of tiles complete all as specified and directed.Make : Johnson / Kajaria / Somany |
| 38 | M&L for Granite (of any type) tiles 20mm thick (approved colour) machine cut, bedded with 20mm screed bed in cement mortar 1:4 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding, and polishing complete all as specified and directed. |
| 39 | M&L for 20 mm thick granite (of any type) (approved colour) machine cut as in vertical surfaces and like, jointed with grey cement slurry and pointed with white cement with admixture of of pigment to match the shade of granite stone incl grinding, polishing laid over and including 15 mm thick backing layer in CM 1:4 complete all as specified and directed. |
| 40 | M&L for Providing edge moulding to 18 - 20 mm thick stone of any description of counters vanities etc incl machine polishing to edge to give high gloss finish etc complete all as specified and directed. |
| 41 | M&L for 25mm thick cement concrete type B-0,1:2:4 (12.5mm graded aggregate) as in sub bsae floor complete all as specified and directed. |
| 42 | M&L for machine pressed precast concrete inter locking pavers block of any shape, colour and pattern (as aprroved by engr in charge) conforming to IS-15658-2006 of 80 mm thickness, M-40 Grade with grey cement and no pigment laid over 40mm thick sand cushioning (Sand shall be measured supply only) complete all as specified and directed |
| 43 | Supply only sand for laying of pavers complete all as specified and directed. |
| 44 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 45 | Excavation of post holes (or similar holes) in Soft/loose soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good final finished surface complete all as specified and directed. |
| 46 | M&L for Cement concrete type B2 1:2:4 (40 mm graded aggregates) in foundations, filling and mass-concrete incl required Form work complete all as specified and directed. |
| 47 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 48 | S&F Steel work in tubular tru-sses of required shape including special shaped washer etc, complete using ERW or induction butt welded tubes conforming to grade St.-240, complete all as specified and directed. |
| 49 | S&F 10 mm thick new polycarbonate sheet in roof covering to cover the connecting passage steel structure between B-11 and B-12 both side UV coated for 50 micron thick , Weight of polycorbonate sheet 1.75 kg. per Sqm, colour as approved and fixed with self -taping screws as required at site and sealing the joints with liquid sealent complete all as specified and directed by Engr in charge.Make : Duratuff, Lexan, VMT Paste Ltd, M/s Coxwell Domes Engg Pvt. Ltd. |
| 50 | M&L for Providing and fixing Factory made single extruded WPC (Wood Polymer Composite) for WPC jali & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and lengthincl M.S. hold fast/ lugs or SS dash fasteners and all cpmplete necessary fixing arrangement complete all as specified and directed by Engineer-in-Charge.Note: For WPC solid Jali frames and other frame , minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 51 | M&L for Providing and fixing at site Factory Made 24 mm thick 100% Solid WPC (Wood polymer Composite ) Plain Jali cut on CNC machine of approved design & measured size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural Fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with density not less than 650 kg/cbm manufactured by an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Strength of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof, Fire Retardant and fixing with stainless Steel butt full body threaded star headed counter sunk SS Screws incl dismantling old RCC jali All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company complete all as specified and directed.Make :Make : Rajshri / Fenesta / Ecocell Note :- Staircase arrangement for fixing wpc jali up to fourth floor will be made by contractor |
| 52 | S&F Framed work Fe-410-W (Gde-E-250 quality-A) as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 53 | S&F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 making good of dismantled portion by plastered work and match with existing surface complete all as specified and directed. |
| 54 | M&L for preparation of new or previously untreated surfaces, of steel and iron work of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of Red oxide complete all as specified and directed. |
| 55 | Dismantling of wall and ceiling boards of any type or any size (fibre, pulp, insulation, etc) or insulation boards / slabs/ blankets, any thickness, incl cover fillet complete all as specified and directed. |
| 56 | M&L for powder coated GI T Grid system in 600 x 600 mm module which includes providing and fixing wall angle along the perimeter of the room with nylon sleeves and wooden screws at 300 mm centre to center. Suspendeding the main tee of size from the soffit, soffit cleat, rawl plugs and wire rod & leveling spring clip at 1200mm center to center cross tee, interlockined into the pre-cut slots in the main tees at 600 mm centre to center in direction perpendicular to the main tee to make a grid of 600x 1200mm. 600 mm cross tees are interlocked in the pre cut slots in the 1200mm tees at 1200 mm center to center in direction parallel to the main tee. Cross Tees having length more than 600 mm are to be supported independently. 4.5 mm thick E board or perforated type ceiling tiles with square Edge of size 595x595 mm be placed in the grid of 600x600mm.Size of grid as speicfied by Manufacturers, complete all as specified and directed. |
| 57 | Taking down chowkats or frames not exceeding 1.5 Sqm each with shutters (without taking off the shutter from the frame) complete all as specified and directed. |
| 58 | Taking down chowkats or frames exc 1.5 sq. m but n exc 4 sqm including shutter and after replacing chowkats the old shutter shall be refixed in same opening complete all as specified and directed. |
| 59 | S&F factory made uPVC brown colour Three track jointless three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. comprising of uPVC multi- chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and incl provn of guard bars of 10 mm square MS bar as safety grill, necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, incl all required hardware fitments complete all as specified and directed by Engineer-in-Charge. Note: Rate of Glass or wiremesh shall not be paid separately rate is included in the quoted rate and no seperate payment will be given for glass and wiremesh) (Rate of 10 mm square MS bar will be included in the quoted rate and no seperate payment will be given for guard bar) Make : Rajshri / Fenesta / EcocellNote: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 60 | S&F Aluminium powder coated/UPVC coloured decorative grill with 6.3mm thick upvc section and 100X100mm openings , weighing not less than 1.75Kg/Sqm and anodized upvc 'U' shape channel frame work allaround the grill incl necessary fixing arrangements with Aluminium/UPVC window upto G+1 building (if required opening for handle or AC as complete) complete all as specified and directed by Engr in Charge. |
| 61 | S&F uPVC ventilator with exhaust fan, for ventilation in toilet with (openable type window / Fixed glass as per requirement) of frosted glass with uPVC frame of approved colour, thickness 60 mm, Length 750mm and height 600 mm complete all as specified and directed. |
| 62 | S&F factory made single extruded WPC (wood polymer composite) solid door/window/Ceosetory windows and other frames/chowkat of size 100mmx50 mm comprising of virgin PVC polymer of K value 50-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame dencity of 750kg/cum, screw withdrawl strength of 200N (Face and 1100N edge), minimum compressive strength of 58N/Sqmm and resistance to flame of class A category and property of being termite/borer proof, water/moiture proof and fire retardant and fixed with MS hold fasts/lugs/SS Dash fastener of required dia and length of complete as per direction of Engr in charge.Note : For WPC solid door /windows frames, minus5mm tolerance in dimension ie depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made. Make- Rajshree/ Yashpoly/ Century |
| 63 | S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge. Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)complete all as spd and directed. Make- Alstone/ Yashpoly/ Century |
| 64 | M&L for 12mm thick toughned glass door end seal and fixed with stainless steel floor springs, 2nos of stainless steel handle 600mm long fancy type in each shutter fixed to glass door, heatching/flim of approved design on the glass complete all as specified and directed.Note: Floor spring and handles measured and paid separately |
| 65 | S&F 32 mm dia 600 mm long handle suitable for glass door complete all as specified and directed. |
| 66 | S&F Stainless steel body and internal machanism heavy duty concealed floor spring suitable for 12mm thick glass door 1.1 mtr span fixed on tiles or granite surface complete all as specified and directed. |
| 67 | Supply and fix stainless steel body centre locking arragement suitable for glass door complete all as specified and directed |
| 68 | supply only Sheet glass of 4.8 mm thick plain glass sheet selected quality, exc 0.5 sq. m in each pane complete all as specified and directed. |
| 69 | S&F 150 mm Extruded aluminium alloy handles, fabricated type., anodised complete all as specified and directed. |
| 70 | S&F Butt hinges in 100 mm Size, medium weight, cold rolled mild steel, and fixed complete all as specified and directed. |
| 71 | S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 72 | M&L for preparation of old steel and iron surfacesof any description, not otherwise descri-bed, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 73 | S&F in repair 110 mm dia PVC (SWR) pipes (6 kg/ cm2) pressure pipe, single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. Make:- Finolex / Supreme/ Vectus |
| 74 | S&F in repair 110 mm PVC (SWR) bends any radius complete all as specified and directed. |
| 75 | M&L for uprooting of plants (girth n.exc 15 cm of trunk to any height of plants) grown along the pipes or walls, chajjas, parapets and roof of bldgs and making good the surfaces as per existing surfaces and pouring acid not less than 100 ml for each plant in the root to avoid further growth as directed. Any other grass plants etc below 45 cm height shall be deemed to be removed from the premises complete all as specified and directed. |
| 76 | S&F Awning with a metal frame (aluminum or steel) of any approved colour fabric cover, as per the following specifications and drawings. The frame structure shall be made of 6063T5 aluminum extrusions or galvanized MS (Mild Steel) pipes/tubes (e.g., IS 1161/IS 1239 YST 240/IS 4923 YST 310 grade), with all exposed steelwork hot-dip galvanized or powder coated for corrosion resistance. The cover shall be a PVC-coated fabric or 100% solution-dyed acrylic fabric (in any approved pattern) that is UV and weather-resistant, fire retardant, and resistant to atmospheric contamination. The fabric shall be stretched tightly over the frame using the staple-in method with PVC trim or screws, ensuring no wrinkles or sagging. The awning shall be designed to meet regional code restrictions for wind, snow, and live loads (typically 5 psf live load) and securely connected to structural supports of the building using appropriate mounting hardware. Installation must be structurally sound, level, plumb, and leak-free, with dimensions (width, projection, clear height) as per approved shop drawings. The work includes all fasteners, fittings, hardware, installation accessories, shop drawings, testing documentation, and making good any damaged portions, complete all as specified and directed. |
| 77 | Demolition cement concrete (reinforced) in ground floors and upto 4 storey of any description and in any position (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 78 | M&L for reinforced cement concrete type B-1 1:2:4 using 20 mm graded aggregates (Nominal Mix) as in slab supported on walls, beams and columns in floors, roofs, landings,balconies, canopies, deck slab and in shelves and the like. complete all as specified and directed. |
| 79 | Form work to soffits of suspended slabs as roof slabs, floor slabs, landings and similar work n.exc 200mm thick for fair finished surfaces (Horizontal or sloping) complete all as specified and directed. |
| 80 | Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide for rough finished surfaces complete all as specified and directed. |
| 81 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required,including cranking, bending, spirally for hooping for columns, hooking ends and binding with with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 82 | Dismantling water tanks exc 250 ltr and n.exc 500 ltr and removal from site to store complete all as specified and directed. |
| 83 | S&F Rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 1000 Ltrs Including making connection for inlet & outlet with connection piece complete all as specified and directed. Make : Prayag/ Sintex/Vectus |
| 84 | S&F in repair ball brass valves high pressure with polythene float & flynut complete screwed for Iron pipe or brass ferrule of 20 mm dia and fixed complete all as specified and directed. |
| 85 | S&F in repair 20 mm bore gun matel globe or gate valves with iron wheel, screwed both ends for iron pipes fixed complete all as specified and directed. |
| 86 | S&F in repairs CP grating 125 mm dia round fixed on floor/Nahani trap fixed withcement mortar including necessary cutting etc complete all as specified and directed. |
| 87 | Demolition of existing treatment like PCC padding Cement Concrete/ roof tiles (unreinforced)/brick tiles of any description incl. plastering and leeping complete all as specified and directed. |
| 88 | M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed. |
| 89 | M&L for brushing neat cement slurry with 3.0 kg of cement per sq. metre complete all as specified and directed. |
| 90 | M&L for 25mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregates) as in roof padding,roof kerb or mud stop, rounded or chamfered on edge complete all as specified and as directed. |
| 91 | M&L for 10 mm thick rendering of CM 1:4 on cement concrete, mixed with integral water proofing compound as per manufacturere's instructions . (water proofing compound shall be measured and paid seperately) complete all as specified and directed. |
| 92 | Supply only water proofing compound liquid @ 200 ml / per bag of cement complete all as specified and directed. |
| 93 | M&L for heat reducing water proofing treatment of roof with reinforced elastomeric liquid waterproofing membrane of 400-micron thickness in four layer(100 micron each layer) having SRI of 130, tested as per ASTM E 1980 (with Solar Reflectance and Thermal emittance tested as per ASTM C 1549 and ASTM C 1371 , respectively). The coating should have water absorption less than 1% as per IS: 101 (P-7/Sec-1) 1989, with the ability to resist heat upto 120 degree celcius as per IS: 101 (P-7/Sec-3) 1990 having VOC less than 1.00 g/ltr as per ASTM D 3960 and should have excellent resistance to transmission of ponded water up to 2.5 bars of pressure for 7days. It should also be resistant to Ammonia solution, Sodium nitrate, Sodium hydroxide, along WIth water and soap solution as per IS: 101 (P-7/Sec-2)1990. The waterproofing heat reducing membrane will be laminated with 25 - 40-micron thick transparent Nano modified composite crosslinking polymeric coating with a minimum of 40% solid content as per IS: 101 (P -8/Sec6)1993 and also should pass Impact test as per IS: 101 (P-5/Sec-3) 1988 along with having dust and water repellent & anti-graffiti property passing Scratch hardness test of 500g as per IS: 101 (P-5/Sec-2) 1988. It should also pass Cross Cut Adhesion test as per IS: 101 (P-5/Sec-2) 1988. The Polymeric coating should have a self-cleaning and easy-to-clean property with excellent weather stability and DPR (Dirt pickup ratio). Surface preparation includes cleaning the surface with wire brush and washing cleaning to remove all dust, fungus, etc.The work will be done under the supervision of the Engineer-in-charge.The coating thickness and the methodology of application shall strictly be carried out by the authorised vender/ manufacturers with all specifications and as approved by the Engineer-incharge. The manufacturer / authorised vender shall give a warranty for the peformance& durability for 7years.the work includes dismantling of existing roof tiles as well complete all as specified and directed.Make : Starshield,Berger,Home Shield, Asian Apcotherm,JK profix) |
| 94 | M&L for Machine cut Pre polished kota stone slab/tiles flooring 20-25mm thick in any size over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and incl 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 95 | M&L for Kota stone Pre polished kota stone slab/tiles 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed over and incl 10mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 96 | M&L Providing PVC SHEET WALL PANELLING of thickness 5mm ( ±0.25 ) consisting of panels of desired size stuck on inner frame work of 50mm wide strips of 5mm ( ±0.25 ) thick PVC sheet. The panel & strips shall be Density of 600 Kg /Cum Manufactured by an ISO-9001-2015 certified Company. The strips should have in their center a grove of 6mm width and 1mm depth for sinking the head of the screw used to fix the strips to the wall vertically at an equal interval of 10” between two PVC strips. The PVC strips shall be fixed to the wall using 65mm long M.S. screws through the groove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200mm. A groove of 2mm may be left at the joint of two panels for aesthetic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. Optionally a strips of 5mm ( ±0.25 ) thick PVC sheet of width 75mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cement complete all as specified and directed. |
| 97 | M&L for PVC 'L' angles fixed at where direction changed portion with adhessive or as per manufacture instruction complete all as specified and directed.Note :- The work described in these items shall be executed in bldgs up to (G+3 floor) hence the contractor shall make scaffolding arrangements, trestles, ladders etc and hessian clothes for protection & all other safety precautions up to 04 storeys of buildings and the cost for the same is deemed to be included in the quoted unit rates.Note :- Removing building materials /old waste unwanted existing material of any description or any type etc.on alternate day to a distance of 5km or beyond out side MOD Land and the cost for the same is deemed to be included in the quoted unit rates. |
| 98 | E&M PORTION:Taking down carefully old point wiring with aluminium/ copper conductor (Light / Fan/ Socket/ power Point ) complete including fittings such as ceiling rose, pendent holders, regulators and socket point etc and making good the disturbed surface & wall/ floor complete all as specified and directed by Engr in charge. |
| 99 | M&L for point wiring with PVC insulated unsheathed multi stranded FRLS type copper conductor cable of size 1.5 Sqmm 1100 V grade including one run of PVC insulated unsheathed multi stranded FRLS type copper conductor cable of size 1.5 sqmm as earth continuity conductor connected to common earth dolly in and including PVC concealed conduit 20 mm dia medium grade ISI marked and its accessories including provn of new factory made pressed steel modular switch/terminal box of suitable size and new modular front & back plates of approved colour/model of suitable size for housing the modular switches, sockets, fan regulators for one light/ fan/ exhaust fan point controlled by one no, one way 5 Amp switch complete all as specified and directed.Note: (i) Cutting chases for concealed conduit and making good in cement mortar is deemed included in unit rate.(ii) No cutting shall be done in the roof for laying PVC conduit for ceiling point wiring. In this specified portion wire shall run through the existing conduit or surface new conduit shall be provided as required.(iii) In case the wiring is encountered with any beam/column, then the wiring will run on surface to avoid any damage to the RCC portion.Make: Polycab/ RR Kabel/ KEI/ Finolex/ Havells |
| 100 | All as per item No 98.00 above but for One three pin 5 Amp socket outlet point controlled by one no, one way switch on same board complete all as specified and directed. |
| 101 | All as per item No 98.00 above but for One three pin 5 Amp socket outlet point controlled by one no, one way switch on independent board complete all as specified and directed. |
| 102 | All as per item No 98.00 above but with 2.5 sqmm (for phase, neutral) and 2.5 sqmm (for continuous earth wire) cable for one 15/16 Amp socket outlet point on independent board complete all as specified and directed. |
| 103 | S&F in replacement of modular Switch 6 amps, 230 volts, single pole, one way (ISI marked) complete all as specified and directed Make: Legrand CAT Part No.573400, Havells (Murano) CAT Part No. ACUSXXW101, Schneider cat part No -X1101WH |
| 104 | S&F in replacement of 16 Amp rating modular switch one way one module complete all as specified and directed.Make: Legrand CAT Part No. 573410, Havells CAT Part No. ACUSXXW161, Schneider Cat Part No -X1101WH |
| 105 | S&F in replacement of modular socket out let 230 volts grade (as catered in point wiring above) 6 Amp - 2/3 pin combined 2 module complete all as specified and directed.Make: Legrand CAT Part No. 573470, Havells CAT Part No. ACUKXXW063, Schneider Cat Part No -X2005WH |
| 106 | S&F in replacement of modular socket out let 230 volts grade (as catered in point wiring above) 16 Amp - 2/3 pin combined 2 module complete all as specified and directed.Make: Legrand CAT Part No.573471, Havells CAT Part No. ACUKCXW163, Schneider Cat Part No -X2106WH |
| 107 | S&F in repair Modular MCB SP 16 Amps 240V 3 KA, C Curve, fitted in main switch board, including 2.5 sqmm wire connecting power socket & modular MCB complete all as secified and directed by Engr-In-Charge. Make: Havells Cat Part No DHFNCSPA016, LK (L&T) Cat Part No CB93101KW16, Schneider Cat Part No P8016-N. |
| 108 | S&F in replacement of factory made SPN DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 12 way SPN 220 Volts, with suitable busbar, neutral link & earth link suitable for complete all as specified and directed.Make : Legrand Cat Part No 507612, L&T Cat Part No BH112DDB, Schneider Cat Part No A9HSND12. |
| 109 | S&F in replacment MCB, SP 6 to 32 Amp, 10 KA rupturing capacity, IS-8828 marked, and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed.Note : Make of the MCB should be the same as that of DB |
| 110 | All as per item No 108.00 above but MCB SPN 32 Amps complete all as specified and directed. |
| 111 | S&F in replacement remote controlled BLDC ceiling fan 1200 mm sweep, with remote, having minimum CMM 215 and RPM 340, operating at 230 volts, 50Hz, having full copper motor & powder coated ribbed aluminium blades for higher air delivery, longer life complete with all the accessories including making arrangements to hanging of fan to ceiling with proper hook, nut,bolts & remote stand complete all as specified and directed.Make : Havells Cat Part No Ambrose slim star 1200, Orient Cat Part No Ecotech Prime, Bajaj Cat Part No Bajaj Ethora Plus. Note:- The ceiling fan with complete accessories to be safely deposited to MES store yard. |
| 112 | S&F in replacement of LED lights fitting 16-20W, 220V, (approx size 4 ft) PF> 0.95, min efficiency mini 100 lumen/watt, IP 20 rating, AC with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.Make: Bajaj /Crompton /Phillips |
| 113 | S&F in repair LED Bldg security light fitting 35 Watt 230 V PF>0.95 AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.Make: Crompton/Philips/Havells. |
| 114 | S&F in replacement aesthetically designed muziris decorative warm white LED picture light/mirror light of 8-10 watt, PF>0.95, min efficiency 100 lumen/watt, IP 20 rating CCT-3000K fixture with bronze finish for superior feel including suitable LED lamp of 10-12 W complete all as specified and directed.Make: Philips/Bajaj/Crompton |
| 115 | S&F in repair submain wiring with PVC insulated unsheathed copper conductor multi stranded FRLSH type 1100V grade 2 x 4 sqmm complete drawn in new PVC concealed conduit of 25 mm dia and its accessories along with 1x 4 sqmm PVC insulated unsheathed copper conductor multi stranded FRLSH type cable for continuous earth wire and duly connected to common earth dolly complete all as specified and directed.Make- Polycab, Finolex, RR KABEL |
| 116 | S&F in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V,PF>0.95, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.Make : Havells Cat Part No VENUSNEO2X2PLR36WLED865PO /Philips Cat Part No RC370B LED36S-6500 G6 L60W60 PSU OD S6/ Crompton Cat Part No- LCTLRP-36-FO-CDL.Note: (a) Srl Item No 32.00, 41.00, 47.00 to 53.00, 55.00, 58.00, 61.00, 63.00, 75.00, 89.00 to 93.00, 95.00, 110.00, 112.00, 114.00 & 115.00 of BOQ and all bathroom fittings and sanitary items are major items for the subject tender and material in respect of these items shall be procured within one month after placing of work order and produced before Engg in Charge alongwith original purchase vouchers as per direction of Garrison Engineer and shall obtain a certificate from Engg in charge that material in respect of above mentioned items have been submitted in the office of Engg in charge in their safe custody.(b) Materials in respect of Freakishly low declared items if any at the time of acceptance of contract shall be procured within one month after placing of work order and submit the same in the office of Engg in charge alongwith original purchase vouchers in their safe custody and shall obtain a certificate from Engg in charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender