Tender For Repairs To Hangar Doors, Sheets, Cladding, Rolling Shutter And Gates At Hansa Tech Area And Nay (Goa) Under Ge (Nw) Vasco (Tender Id No. 2026_Mes_788462_1)
Tender Value
44.98 Lakhs
Estimated cost
Bid Submission
30 Sep 2026
20 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs To Hangar Doors, Sheets, Cladding, Rolling Shutter And Gates At Hansa Tech Area And Nay (Goa) Under Ge (Nw) Vasco (Tender Id No. 2026_Mes_788462_1)
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed |
| 2 | S & F framed work a s in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete confirming to Fe 410 - W (Gde- E- 250) quality - A complete all as specified and as directed |
| 3 | Dismantling mild steel work of any description not otherwise provided for complete all as specified and as directed |
| 4 | S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails and fastenings and heavy bracket framings (Beam,tee, angle, channel or flat sections) confrming to Fe 410-W( Gde - E-250) quality - B including cleats,distance pieces etc complete all as specified and as directed |
| 5 | M & L for running welding in repairs thickness of metal to be welded exceding 6 mm but not exceeding 9mm complete all as specified and as directed |
| 6 | Welding in repairs thickness of metal to be welded exceding 9 mm but not exceeding 20 mm and exc 2.5cm but n exc 5cm in length complete all as specified and as directed |
| 7 | Overhauling the bottom wheel and existing gear system of bottom wheel of hanger steel door incl dismantling from the steel door and refixing in the same position incl derusting cleaning and greasing of wheel & bearings without taking down door complete all as directed to make in serviceable condition complete all as specified and as directed |
| 8 | All as per item No 7 above but incl replacement of two bearings complete all as specified and as directed |
| 9 | Overhauling the top wheel incl derusting , cleaning and greasing incl. dismantling and opening of bearing and making serviceable for smooth functioning of door complete all as directed without taking down shutter complete all as specified and as directed |
| 10 | S&F bottom wheel of hangar in cast iron including bush bearing axle and all other necesssary items as per the existing design after taking down the shutter incl replacement of existing wheel with new wheels. |
| 11 | S&F for sealing holes around 'J'/'L' bolts in CGI sheets roofing of hangers/building with using silicon solusion doctor fixit or wilson 10 all as per manufacturer instructions complete all as specified and as directed |
| 12 | M&L for taking out old bolts from any type of roof and sealing with one bitumen and one curved GI washer on either side and provision of new J/L hooks/6mm dia GI bolts and nuts all set in stiff white lead all as directed by Engr-in-Charge |
| 13 | M&L for taking out old bolts from any type of wall cladding and sealing with one bitumen and one curved GI washer on either side and provision of new J/L hooks/6mm dia GI bolts and nuts all set in stiff white lead complete all as specified and as directed |
| 14 | M&L to bottom wheel of hanger steel door with replacement of bush bearing axle and tighting to crank and chain greasing to wheel cranke and chaine to make it serviceable for smooth run incl replacement of existing wheel with new wheels complete all as specified and as directed. |
| 15 | M&L for Preparing new surfaces of iron and steel and applying one coat of redoxide zinc chrome primer and two coats of Epoxy anti- corrosive paint over 10 cm width or girth complete all as specified and as directed |
| 16 | M&L for preparation of old steel surface and applying one coat of Epoxy anticorrosive paint over 10 cm width or girth complete all as specified and as directed |
| 17 | Taking down eves, gutters and rain water pipe (any size or pattern) incl all fittings,heads, shoes,bends and swan neck etc incl cleaning for refixing or removal complete all as specified and as directed |
| 18 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed |
| 19 | S&F PVC (SWR) bends of 110mm radius complete all as specified and as directed. |
| 20 | Supply & fixed PVC 1/2 rounded gutters of 180mm with union sockets to jointes set in approved jointing compound complete all as specified and as directed |
| 21 | S&F 200mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed |
| 22 | S&F for PVC plain bends 200mm bore complete all as specified and as directed |
| 23 | Dismantling water tanks and removing to store any capacity exc 250 and n.exc 500 Ltrs complete all as specified and as directed |
| 24 | Dismantling water tanks and removing to store any capacity exc 500 and n.exc 1000 Ltrs complete all as specified and as directed |
| 25 | Rotational moulded polyethylene water storage tanks 500L capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed |
| 26 | Rotational moulded polyethylene water storage tanks 1000L capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed |
| 27 | Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia complete all as specified and as directed. |
| 28 | Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 25 mm dia complete all as specified and as directed. |
| 29 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 20 mm complete all as specified and as directed. |
| 30 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 25 mm complete all as specified and as directed. |
| 31 | Stop valve 20mm dia of PTMT any colour high pressure screwed for iron pipe and fixed in repairs. (Minimum weight 15mm-90gms complete all as specified and as directed. |
| 32 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 33 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding/roof gutter/wall, made to shape as required, fixed with self tapping screws complete all as specified and as directed. NOTE : (i) The GI sheets shall be fixed in a such way to match the existing sheets profile , so that there is no leakage /seepage issued occured.(ii) The framed truss shall be sealed in such way to restrict any kind of bird menace through truss strcuture. |
| 34 | Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 35 | Fixing only Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 36 | S&F in repairs embossed translucent polycarbonate skylight corrugated sheet of 2 mm thickness as in roof covering, fixed with self tapping screws all as specified and directed by Engr-in-charge. |
| 37 | S&F in repair, 3 layer UPVC roof sheet (any colour ) of required thickness(2.5 mm to 3.00 mm as in roof covering, fixed with self tapping screws and to match with existing cladding and roof sheet all as specified and directed by Engr-in-charge. |
| 38 | Dismantling of stone slabs and tiles laid dry or laid dry and pointed of any description or thickness in floors or aprons complete all as specified and as directed. |
| 39 | Dermolition of cement concrete unreinforced in ground floor and pavings n exc 15cm thickness below or above GL complete all as specified and as directed. |
| 40 | Taking down cement plastering at any description on brick or stone wall etc including raking out joints hacking for key scrubbing down with water etc and removal of debries and depositing where directed. complete all as specified and as directed. |
| 41 | M&L for rendering 5 mm thick in CM 1:3 in ceiling finished even and smooth (without using extra cement) complete all as specified and as directed. |
| 42 | M&L for Preparing new plastered ceiling surfaces and applying two coat of oil bound distemper over alkali resistant primer on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling complete all as specified and as directed. |
| 43 | M&L for Rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & smooth w/o using extra cement complete all as specified and as directed.Note :- Integral water proofing liquid will be measured and paid seperately. |
| 44 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 45 | M&L for rendering 15 mm thick in CM 1:6 on concrete solid block wall internal surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 46 | M&L for Preparing new plastered wall surfaces and applying two coat of oil bound distemper over alkali resistant primer on plastered surfaces, preparatory to distempering, after applying 1-2mm thick wall care putty on wall complete all as specified and as directed. |
| 47 | M & L for preparation of new plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm all as specified and as directed. |
| 48 | M&L for complete removal of existing treatment and Preparing old plastered ceiling surfaces and applying two coat of oil bound distemper over alkali resistant primer on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling complete all as specified and as directed. |
| 49 | M&L for complete removal of existing treatment and Preparing old plastered wall surfaces and applying two coat of oil bound distemper over alkali resistant primer, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall complete all as specified and as directed. |
| 50 | M & L for preparation by complete removal of existing treatment of painted walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm all as specified and as directed. |
| 51 | M&L Cement concrete type C- 2, 1:3:6 (40mm graded aggregate) 75mm thick as in sub base of flooring/plinth protection all as specified |
| 52 | M&L sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 53 | S&F machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 60mm thickness M-40 grade with grey cement and pigment complete all as specified and as directed. |
| 54 | Dismantling of existing steel rolling shutters including top covers for repairs & refixing in the same opening after repairs including greasing the spring, guide channel shafts, bearing, bolts, washers, including repairing defective laths spring bearing , hood cover, guide channel suspension shafts etc complete as directed by Engr-in-Charge for rolling shutter of clear area upto 7 Sqm each.Note :- Necessary spares will be measured & paid seperately. |
| 55 | Dismantling of existing steel rolling shutters including top covers for repairs & refixing in the same opening after repairs including greasing the spring, guide channel shafts, bearing, bolts, washers, including repairing defective laths spring bearing , hood cover, guide channel suspension shafts etc complete as directed by Engr-in-Charge for rolling shutersof clear area exc 7.00 sqm but not exc 10 sqmNote :- Necessary spares will be measured & paid seperately. |
| 56 | Dismantling of existing steel rolling shutters including top covers for repairs & refixing in the same opening after repairs including greasing the spring, guide channel shafts, bearing, bolts, washers, including repairing defective laths spring bearing , hood cover, guide channel suspension shafts etc complete as directed by Engr-in-Charge for rolling shuters of clear area exc 10 sqm but not exc 20 sqm.Note :- Necessary spares will be measured & paid seperately. |
| 57 | S & F Ball bearing for rolling shutter complete all as specified and as directed. |
| 58 | S & F Steel rolling shutters of 1.25 mm thickness laths without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated complete push & pull or manual type complete all as specified and directed. |
| 59 | S & F Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: with bevel gear box and crank handle 1.25mm thick complete all as specified and directed. |
| 60 | M&Lfor preparation of new steel surfaces of any description over 10cm width or girth and applying two coat of aluminium paint First quality over a coat of aluminium red oxide primer all as directed and specifried |
| 61 | Providing and applying in repairs 5.3mm ESD-Epoxy antiskid floor coating system including surface preparation by cleaning surface from dust, dirt, muck,moisture and all foreign material and cleaned by mechanical means using mechanical scrubber/grinder, chemical treatment for cleaning oil if required followed by application of primer Nitoprime 25 of Fosroc or equivalent in Sika/Bostik which shall be a two component, epoxy based system. The pre packed and factory weighed two components shall be mixed for 3 mins using a low speed drill and applied at 5.5 - 6.5 m2/ltr @ 200 microns thick. Then providing and applying the screed layer with Nitoflor EU5 of Fosroc or equivalent in Sika/Bostik at minimum thickness of 3000 [email protected] m2/pack @ 2mm thickness. The self levelling screed shall consist of a low viscous epoxy system and graded aggregate ( special silica/Filler). The pre packed components shall be mixed as per the packing ratio and applied. |
| 62 | The epoxy underlay shall achieve a minimum compressive strength of 60 N/mm2, Flexural strength of 20 N/mm2 and Tensile strength of 10N/mm2 @ 7 days. The underlay shall have nil water absorption when tested as per BS1881 Part 122-1983. Then over the screed apply copper tape of 100microns thick and 25mm width, connected to existing earth pit having spacing 10m both directions, then conductive primer coat Nitoflor SL of Fosroc or equivalent in Sika/Bostik Conductive Basecoat shall be applied at a thickness of 100 microns and then top coat of 2000microns - Nitoflor SL conductive of Fosroc or equivalent in Sika/Bostik shall be applied to provide Approx approx. 3x103 - 9 x103 Ohm Surface resistance . Which shall be supplied in pre-weighed packs and ready to mix and use which will consist of resin, hardner, EPI (colour concentrate) formulated aggregate and carbon fibre + special anti skid silica sand/Filler. |
| 63 | All these to be mixed in the pre weighed ratio, add EPI colour (colour concentrate) and formulated aggregates + special antiskid silica sand/Filler to agitate the mixture by an elecrically driven motor and lay the mixture to the thickness of 2000 microns then deaerate by using spike rollers and to allow to cure for a minimum period of 48 hours before trafficking is commenced. Over top coat demarcation paint with flourescent will be applied. |
| 64 | M & L for providing & applying white or yellow (Aisle) band Marking with 2 component polyeurathane resin + Hardner with flourescent (FK 666) on applied EPU flooring complete all as specified and directed |
| 65 | S&F in repair PVC bird proofing net in green colourt of size 28mm x 28 mm x 4mm thick wt not less than 650gms/sqm and MS flat size 40mm x 3mm fixing with MS angle 50x50x6 mm etc all as specified and directed by Engr-in-charge. Note: MS flats and MS angles will be measured separately complete all as specified and directed |
| 66 | Demolition of stone /boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles. complete all as specified and directed |
| 67 | M & L for Pre - cast cement concrete masonry with Grade C-5.0, (20mm graded stone aggregate) with solid blocks wall built in cement mortar 1:6 complete all as specified and directed |
| 68 | M & L for cutting and racking out joints with cutter and cleanng with blower and making sides of joints bitumen free for all joints and sealing the joints with single component poluurethene based sealent seal N Flex FC of M/s Bosik/ Fosroc/ Cip/ Sika, or equivalent approved by E-in-C's Branch, over a coat of N49 primer of M/s M/s Bosik/ Fosroc/ Cip/ Sika, or equivalent approved by E-in-C's Branch, including bond breaker caulked tightly into the following size of joints.Make - Bostik/ Fosroc/ Cipy/ Sika, approved by E-in-C's branch complete all as specified and as directed. |
| 69 | 10mm x 15mm |
| 70 | 15mm x 15mm |
| 71 | 20mm x 15mm |
| 72 | 25mm x 15mm |
| 73 | 30mm x 15mm |
| 74 | S & F Polyoefin all weatherproof Co-polymer anti bird net in UV any colour of mesh size 25mm X 25mm X (+/- 2mm with Mesh breaking strength 12Kgf) having twine dia 1.00mm (Twine breaking strenth 16Kgf) as in verticle to be fitted in hanger door top rails assembly using rope (wire) and pully system hanging from a height of upto 28 meters etc all as specified and directed by Engr-in-Charge.Note :- Rates are inclusive of material, fixing, scaffolding/ ladder, pully arrangement to work at height upto 28 mtr complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysOct 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender