Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #57429047

Tender For special Repair To Roof Of Bldg No P-110, P-111 And T-112A Off 201 Engr Regt And Other Sanctioned Works Under Age B/R-Ii Of Ge (East) Jalandhar Cantt (Tender Id No 2026_Mes_788135_1)

Issued by Statutory Bodies & Commissions/Committees · Jalandhar, Punjab
Tender Value
48.37 Lakhs
Estimated cost
Bid Submission
30 Sep 2026
20 days left
EMD
96740
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Roof Of Bldg No P-110, P-111 And T-112A Off 201 Engr Regt And Other Sanctioned Works Under Age B/R-Ii Of Ge (East) Jalandhar Cantt (Tender Id No 2026_Mes_788135_1)

BOQ

Name of Work:- Spl repair to roof of bldg no P-110, P-111 and T-112A off 201 Engr Regt and other sanctioned works under AGE B/R-II of GE (East) Jalandhar Cantt (Tender ID No 2026_MES_788135_1)
Sl. No. Item Description
1Demolition of brick tiles single layer as in roof covering, complete all as directed by Eng-in-charge.
2Demolition of mud in roofs any thickness including plastering and leeping (whether full thickness removed or only a part thereof), complete all as directed by Eng-in-charge.
3M&L for PCC (1:2:4) type B-0 (using 20mm graded crushed stone aggregate) as in benching, roof padding, roof kerbs or mud stops, coping etc rounded or chamfered on edges, complete all as specified and as directed.
4M&L for 10mm thick cement plaster in cement mortar (1:3) mixed with integral water proofing compound in the proportion recommended by manufacturer, on concrete roof surfaces finished even and fair, including cleaning the roof top by scraping down with water etc, complete all as specified and as directed. (WPC shall be measured and paid separately under appropriate item of this BOQ).
5Cleaning the surface and made free of dirt, foreign particle, laitance followed by grinding all all protrusion to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expiation contraction. Cutting the grooves with suitable cutter machine in V-groove filled with repairs mortar/ microconcrate/ general purpose grout as recommended proportionally as per recommendation of manufacture. Making of Gollas at all the corners with polymer modified mortar (1:4) cement sand with 3.5% acylic of cement weight, complete all as directed by Eng-in-charge.
6Supply and applying high build elastomeric waterproofing coating based on pure hydrophobic polyurethane cold applied of spray/brush applied, membrane with an elongation of 280% and tensile strength of 2.7N/mm2 as per ASTM D 2370, crack bridging ability of 3mm, no leakage upto 5 bars of water pressure as per DIN 1048, min 88% solid content. The system includes final base preparation, epoxy primer 1:1 (Resin; harder) application with 100% water dilution and Pure polyurethane application in 2 coats with a total min consumption of 1.25 kg per Sqm. Application should be done with Graco sprayer by a company authorised applicator”, complete all as specified and as directed.
7Demolition of brick work as in walls/parapet wall,s removing grass fungus weed, roots of trees completely, grown on roof/wall surfaces, complete all as directed by Eng-in-charge.
8M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6 M mean radius built in CM (1:6), complete all as specified and as directed.
9Taking down cement plaster of any description thickness including raking out joints hacking for key scrubbing down with water, complete all as directed by Eng-in-charge.
10M&L for 15mm thick cement plaster on brick or concrete surfaces in cement mortar (1:4) mixed with integral water proofing compound in the proportion recommended by manufacturer, surfaces finished fair and even, complete all as directed by Eng-in-charge. (WPC shall be measured and paid separately under appropriate item of this BOQ).
11M&L for preparation of new cement surface and applying two coats of acrylic exterior emulsion paint over a coat of wall primer applying by mechanical spray gun including filling uneven surface with putty complete all as per manufacturer instruction and as specifited and directed by Engr-in-charge.
12M&L for preparation and scrapping of old cement surface and applying two coats of acrylic exterior emulsion paint over a coat of wall primer applying by mechanical spray gun including filling uneven surface with putty complete all as per manufacturer instruction, complete all as directed by Eng-in-charge.
13Supply only integral water proofing compound all as specified and directed, complete all as directed by Eng-in-charge.
14S&F PVC (SWR) pipes 110 mm dia with single socketed in any length with rubber ring joints fixed on brick walls or laid in trenches with PCC 1:2:4 complete houching with bedding including demolition and braking up existing pipes with fittings, complete all as directed by Eng-in-charge.
15S&F PVC (SWR) bends 110 mm with access door, complete all as directed by Eng-in-charge.
16M&L Galvanised iron water tubing 15 mm bore, medium grade with & including all fittings fixed to wall, ceilings and or laid in floors etc including taking down the existing tubing, complete all as directed by Eng-in-charge.
17Ditto all as per srl item no. 16 above here-in-before but for 20mm bore tube, complete all as directed by Eng-in-charge.
18Demolition of reinforced cement concrete in ground floors and paving n.exc 15 cm thickness (reinforcement to cut as required to facilitate demolition), complete all as directed by Eng-in-charge.
19M&L for reinforced cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) slab supported on wall, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves, complete all as directed by Eng-in-charge.
20M&L for MS TMT bars 10 mm and over dia and cut to length, bent to shape required including cranking bending spirally for hooping for clos hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed
21M&L for formwork to soffits of suspended slabs such roof slabs, floor slabs, shelves, landings and similar work, not exceeding 200mm thick (horizontal or slopping) rough finished surfaces of concrete flat or shelfs etc. complete all as specified and directed.
22S&F in repair 1000 ltr anti mircobial triple layer UV coating rotational moulded polythylene water storage tank in white colour (Cylindrical vertical with closed top) hosted and fixed in position with 20mm ball valve high pressure, PTMT with polythene float and fly nut including dismantling of existing tank of any description, complete all as specified and as directed. Make: sintex
23M&L for 40 mm thick brick tiles with 15 mm thick bedded layer of 1:3 CM laid on 2nd bitumen coated surface and joints grouted flush mortar 1:3 mixed with 5% of crude oil by weight of cement, complete all as specified .
24Ditto all as per item no.23 above, but except tile, complete all as directed by Eng-in-charge.
25Flush pointing in cement mortar 1:3 on brick tiles laid flat on roof and wall surfaces complete all as spd, complete all as directed by Eng-in-charge.
26S&F 500 ltr rotational anti mircobial triple layer moulded polythylene water storage tank in white colour (Cylindrical vertical with closed top) hosted and fixed in position incl dismantling of existing tank of any description complete all as specified, complete all as directed by Eng-in-charge. Make: sintex
27M&L for 40mm thick brick tiles laid on mud/cement surface and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement, complete all as directed by Eng-in-charge.
28Ditto all as per inem no.27 above, but except tiles, complete all as directed by Eng-in-charge.
29Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil, complete all as directed by Eng-in-charge, complete all as directed by Eng-in-charge.
30Excavating over areas, exc 1.5 m and n. exc 3.00m deep and getting out in soft/loose soil, complete all as directed by Eng-in-charge, complete all as directed by Eng-in-charge.
31Excavating over areas, exc. 3.0 m and exc. 4.50m deep in soft/loose soil, complete all as directed by Eng-in-charge.
32Excavating over areas, exc. 4.50 m and exc. 6.00m deep in soft/loose soil , complete all as directed by Eng-in-charge.
33Excavating over areas, exc. 6.00 m and exc. 7.50m deep in soft/loose soil, complete all as directed by Eng-in-charge.
34Excavating over areas, exc. 7.50 m and exc. 9.00m deep in soft/loose soil, complete all as directed by Eng-in-charge.
35M&L PCC 1:4:8 type D-2 (using 20mm graded crushed stone aggregate) in foundation/mass concrete, complete all as specified and as directed.
36M&L Brickwork with subclass ‘B’ bricks in one brick thick honeycomb walling, complete all as specified and as directed.
37Returning, filling, spreading, levelling, watering, ramming in layers 25 cm, complete all as directed by Eng-in-charge.
38Removing excavated material exc. 250m and n.exc. 500m, complete all as directed by Eng-in-charge.
39M&L RCC (Nominal mix) Type B-O (1:2:4) (using 12.50mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed.
40M&L RCC (Nominal mix) Type B-O (1:2:4) ( using 12.50mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves, complete all as specified and as directed.
41S&F MS TMT bars 6 to 10 mm dia, cut to length, bent to shape required including cranking and bending and binding with MS wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed.
42Rendering 15mm thick on fair faces of brickwork or Sqm concrete surfaces finshed fair and even in CM 1:4, complete all as specified and as directed.
43Supply and filling of 63mm of nominal size Brick bats coarseaggregate, complete all as specified and as directed.
44M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in foundation, filling and mass concrete, complete all as specified and as directed.
45M&L for PCC 1:2:4,type B-1 (using 20mm graded crushed stone aggregate)as in coping and benching, complete all as specified and as directed.
46M& L for 200 mm dia. Reinforced concrete pipe, class NP -3 laid and jointed compete with collars, complete all as specified and as directed.
47M&L For concrete bed to 200 mm dia. Pipe,PCC 1:3:6, type D-2 (using 20mm graded crushed stone aggregate), Including packing under and hancuching against the sides of pipes after they are laid and tested, complete all as specified and as directed.
48S&F for 110 mm PVC (SWR) Rain water pipes single RM 20.00 195.00 3900.00 socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57429047
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.37 Lakhs
LAST DATE 30-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Roof Of Bldg No P-110, P-111 And T-112A Off 201 Engr Regt And Other Sanctioned Works Under Age B/R-Ii Of Ge (East) Jalandhar Cantt (Tender Id No 2026_Mes_788135_1)
Basic Detail
Tender No GE/JULL/ET-65/2026-27
Bidding Type Tender
Location
City Jalandhar
State Punjab
Key Dates
Publish Date 09 Sep 2026
Submission Date 30 Sep 2026
Open Date 05 Oct 2026
Finance
Tender Value 48.37 Lakhs
Tender Fee 500
EMD 96740
Exemption Available
Document List
953a4df8-b21b-4d39-98c0-5bf608e88ba5.html
BOQ_883881.xls
Tender65.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Oct 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

953a4df8-b21b-4d39-98c0-5bf608e88ba5.html

xls

BOQ_883881.xls

pdf

Tender65.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail