Tender For Construction Of 08 Jcos Married Accommodartion With Allied Infrastructure At Fad, Jindrah Under Ge (A) Dhar Road Udh Ur
Tender Value
2.38 Crore
Estimated cost
Bid Submission
15 Oct 2026
35 days left
EMD
3.13 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Udhampur → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 08 Jcos Married Accommodartion With Allied Infrastructure At Fad, Jindrah Under Ge (A) Dhar Road Udh Ur
BOQ
| Sl. No. | Item Description |
| 1 | Sch 'A' Part-I (Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 2 | Construction of double storey building block for 04 x MD accn with permanenet specifications complete all as shown on drawings and as specified. |
| 3 | Construction of building block for 06 x Car Parking Garages and 02 x Scooter Parking Garages for 08 JCOs (single way) including open platform, dwarf wall, toe wall, ramp/apron with permanent specifications, complete all as shown on drawings and as specified. |
| 4 | Total Amount of Sch 'A' Part - II (Site Clearance and Development Work) |
| 5 | Total Amount of Sch 'A' Part - III (Internal Water Supply Work) |
| 6 | Total Amount of Sch 'A' Part - IV (Sec-I) (Internal Electric Supply Work) |
| 7 | Total Amount of Sch 'A' Part - V (Area Drainage Work) |
| 8 | Total Amount of Sch 'A' Part - VI (Sec-I) (Sewage Disposal Work) |
| 9 | Total Amount of Sch 'A' Part -VII (Sec-I) (Road, Path and Culvert Work) |
| 10 | Total Amount of Sch 'A' Part -VIII (Sec-I) (External Water Supply Work) |
| 11 | Total Amount of Sch 'A' Part -IX (Sec-I) (External Electric Supply Work) |
| 12 | Sch 'A' Part-IV (Sec-II) (Internal Electric Supply Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 13 | Point wiring complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20mm dia medium grade (MMS) and all accessories are concealed in walls / roofs / floors / ceiling etc; including modular metal flush box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick including modular top cover plate as per numbers of switch modules for fixing of modular switches, sockets, fan regulators, red colour indicator, blank plates etc. as approved colours and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- Note No1: All necessary accessories such as modular steel box, top cover plate, blank plate, screws, washers and all modular electrical fixtures are to be used of same make/brand only. Note No 2: Any cutting /leaving /forming holes, chases etc., in walls, floors and ceiling as required and making good the same, shall be deemded to be included in lump sum Sch 'A' Part-I as per para 10(b) in Sch 'A' BOQ Notes.(lump sum) |
| 14 | All as per Srl item No. 10.00 but one light point/fan point controlled by one switch 5 Amp on same board |
| 15 | All as per Srl item No. 10.00 but two way switch |
| 16 | All as per Srl item No. 10.00 but one call bell point control by one bell push point. |
| 17 | All as per Srl item No. 10.00 but for one 3 pin, 5 amp socket on same board. |
| 18 | All as per Srl item No. 10.00 but for one 3 pin, 5 amp socket on independent board. |
| 19 | All as per Srl item No. 10.00 but with 4 sqmm cable copper conductor for 15 amp socket with 4sqmm earth conductor. |
| 20 | Concealed sub main wiring of two run with 06 sqmm single core PVC insulated, FRLSH, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit 25mm dia , medium grade, ISI marked and fixed, including cutting /chasing as required and its accessories including one run of 6 Sqmm single core PVC insulated, FRLSH, multi stranded copper conductor cable as earth continuity conductor in green colour, connected to common earth dolly, complete all as specified and as directed. Note No 1:Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only.Note No 2: Any cutting /leaving /forming holes, chases etc., in walls, floors and ceiling as required and making good the same, shall be deemded to be included in lump sum Sch 'A' Part-I as per para 10(b) in Sch 'A' BOQ Notes. |
| 21 | Modular white cover plate suitable for 1 module complete all as specified adndirected. |
| 22 | LED bulb 9 watts, 240 volts, 50Hz, pin type and including removing old unserviceable item complete all as specified and as directed. |
| 23 | LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including taking down unserviceable tube light fittings, complete all as specified and directed. |
| 24 | LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED tube light including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 25 | LED street light fitting 35 Watt, 230 V, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, complete all as specified and directed. |
| 26 | Fabrication of sheet metal enclosure to accommodate 04 No electric meters of size 800 x 500mm x 150mm deep and 1.6mm thick MS sheet, power coated, Bakelite sheet with side hung shutter including provision of locking arrangement and niche covered with 4mm thick plain glass including locking arrangement & open; wiring covered with flexible PVC pipe of suitable size complete all as specified and as directed. |
| 27 | Sch 'A' Part-VI (Sec-II) (Sewage Disposal Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 28 | Construction of septic tank for 50 users (Brick construction) complete all as shown on drg No. CEUZ /TD-1585/2021 sheet 1/4 to 4/4 and as specified. |
| 29 | Construction of soakage well (Brick construction) 2.4m dia and 3.0m deep below inlet pipe level (depth from inlet pipe to ground level 45cm), complete all as specified and shown on drg No. CEUZ/TD-1585/2021 sheet 1/4 to 4/4. |
| 30 | Sch 'A' Part-VII (Sec-II) (Road, Path and Culvert Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. Please Enable Macros to View BoQ information |
| 31 | Sch 'A' Part-VII (Sec-II) (Road, Path and Culvert Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 35 daysOct 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 37 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender