Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #57429044

Tender For Repair/Maintenance Of Lt Panel, Mccbs, Earthing, Summer Appliances, Hot Water Appliances, Hot Water Appliances, Internal Electrification And Mes Installation At Af Stn Aastha Complex & 5 Aflu Under Aor Of Ge (Af) Faridabad

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
29 Lakhs
Estimated cost
Bid Submission
30 Sep 2026
20 days left
EMD
58000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maintenance Of Lt Panel, Mccbs, Earthing, Summer Appliances, Hot Water Appliances, Hot Water Appliances, Internal Electrification And Mes Installation At Af Stn Aastha Complex & 5 Aflu Under Aor Of Ge (Af) Faridabad

BOQ

Name of Work:- REPAIR/MAINTENANCE OF LT PANEL, MCCBS, EARTHING, SUMMER APPLIANCES, HOT WATER APPLIANCES, HOT WATER APPLIANCES, INTERNAL ELECTRIFICATION AND MES INSTALLATION AT AF STN AASTHA COMPLEX & 5 AFLU UNDER AOR OF GE (AF) FARIDABAD
Sl. No. Item Description
1Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified and directed.
2M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and in existing concealed / surface PVC Conduit/ saddle medium grade, ISI marked 20 mm dia along with conduit fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet (Make: Hylam) for provision of switches/regulators complete all as specified and directed.NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls.
3All as per item No 02 above but 5 Amp socket outlet, independent.
4All as per item No 02 above but on the same board.
5All as per item No 02 above but for one bell/Buzzer point controlled by one push button on the same board with other switches or independent with 1.50 sqmm size cable.
6All as per item No 02 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 2.5 sq mm connected to common earth dolly.
7All as per item No 02 above but 15 Amps 3 pin socket outlet on independent board with 4 sq mm PVC insulated and sheathed copper conductor with 4 sq mm PVC insulated copper conductor single core for continuous earthing.
8S&F in replacement of switch piano type 5/6 amp SP one way ISI Marked complete all as specified and directed.
9S&F in replacement of switch 15/16 Amps SP one way ISI Marked complete all as specified and directed.
10S&F in replacement of socket outlet 3 pin 5 Amps flush type complete all as specified and directed.
11S&F in replacement of socket outlet 2-in-1, 3 pin 5 amps and 15 amps flush type complete all as specified and directed.
12S&F in replacement of stepped type electronic fan regulator flush type on the existing phenolic sheet etc complete all as specified and directed.
13S&F in replacement of ding dong bell electric 230 volt AC complete all as specified and directed.
14S&F bell push, in repairs, flush type 5 Amps complete all as specified and directed.
15M&L for one light/fan/exhaust fan Modular point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through PVC casing caping of ISI marked with fixing accessories and with metal flush box and cover plates for modular boards for provision of switches/regulators complete all as specified and directed. NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls.
16All as per item No 15 above but 5 Amp socket outlet, independent.
17All as per item No 15 above but on the same board.
18All as per item No 15 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 2.5 sq mm connected to common earth dolly.
19S&F in replacement for modular switches 6 amps single pole one way complete all as specified and directed.
20S&F in replacement for modular sockets out let 6 amps 6 pin 2 module with shutter complete all as specified and directed.
21S&F in replacement for modular switches 16 Amps single pole one way complete all as specified and directed.
22S&F in replacement modular socket out let 6-16 Amps 3 pin combined shuttered complete all as specified and directed.
23S&F in replacement of stepped type electronic fan regulator modular complete all as specified and directed.
24S&F in repairs,ceiling rose surface backlight, 65 x 50 mm two to to three terminals complete all as specified and directed.
25S&F in replacement of SPN enclosure with two pin and earth plug and socket complete with on SP MCB 20 Amps complete all as specified and directed.
26M&L PVC insulated FRLS single core with strandard copper cable of size 6 Sqmm in two run and 6 Sqmm one run for earth and drawing through existing concealed conduit including taking down old UNSV cable acomplete all as specified and directed. NOTE :- 2 runs of 6 Sqmm cable and one run of 6 sqmm cable will be measured as one running meter for the purpose of measurement and payment.
27All as per item No 26 above here-in-before but copper cable single core of size 4 Sqmm in two run with earth wire 4 Sqmm single run for continuity.NOTE :- 2 runs of 4 Sqmm cable and one run of 4 sqmm cable will be measured as one running meter for the purpose of measurement and payment.
28All as per item No 26 above here-in-before but copper cable single core of size 2.5 Sqmm in two run with earth wire 2.5 Sqmm single run for continuity.NOTE :- 2 runs of 2.5 Sqmm cable and one run of 2.5 sqmm cable will be measured as one running meter for the purpose of measurement and payment.
29Supply and fix in replacement post top lantern LED 40 W or next highest wattage having IP65 protction for single phase connection 50 Hz 230 Volts complete all as specified and directed.
30M&L for Recess mounted 15 Watt high efficancy recess LED slim round downlighter IP20 with high brightness LED for glare free homogenous illumination celing light complete with electronic driver complete all as specified and directed.
31S&F in replacement wall mounting box type LED tube light fitting , extruded aluminium heat sink provided for efficient heat dissipation & Integrated electronic driver 1x20 watt comprising of strong jointless CRCA body complete with all accessories and complete all as specified and directed.
32M&L for Recess mounted 36/ 40 Watt high efficancy 2x2 recess LED flat panel with high brightness LED for glare free homogenous illumination celing light complete with electronic driver complete all as specified and directed.
33Supply and Fixing LED street light fitting 60 Watt pressure die case aluminium housing LED street light luminaires suitable for existing street light pole including all fixing accessaries and complete all as specified and directed.
34Supply and fixing in replacement of old unsv GI bracket made out of 32 mm bore,light grade 1.2 m long bent to shape suitable for street light fitting including MS flat clamp 50 x 6 mm 2 Nos for each bracket with nut & bolt complete all as specified and directed.
35S&F sheet metal enclosures DB Double door Verticle distribution type, 04 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directed.Note : - MCCB shall be measured and paid separately
36S&F sheet metal enclosures DB Double door Verticle distribution type, 08 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directed.Note : - MCCB shall be measured and paid separately
37S&F in replacement MCB DB TPN 4 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed.
38S&F in replacement MCB DB SPN 4 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed.
39S&F in replacement MCB DB SPN 6 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed.
40S&F in replacement MCB DB SPN 8 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed.
41S&F in replacement MCB DB SPN 12 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed.
42S&F in replacement of MCCB TPN 63Amps 16KA complete all as specified and directed.
43S&F in replacement of MCCB TPN 125 Amps 415 Volts 16 KA as per suitable sample of size complete all as specified and directed.
44S&F in replacement of MCCB TPN 100 Amps 415 Volts 16 KA as per suitable sample of size complete all as specified and directed.
45S&F in repairs MCB SP 6 to 32 Amps 240 Volts.\\"B\\" grade complete all as specified and directed.
46S&F in repairs MCB,SP 40 Amps, 240 Volts.\\"B\\" grade complete all as specified and directed.
47S&F in repairs MCB SPN, 40 Amps, 240Volts .\\"B\\" grade complete all as specified and directed.
48S&F in repairs MCB SPN, 63 Amps, 240Volts.\\"B\\" grade complete all as specified and directed.
49S&F in repairs MCB TPN, 63 to 100 Amps,415Volts .\\"B\\" grade complete all as specified and directed.
50Supplying and fixing PVC conduit 25 MM dia along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed.
51S&F in replacement of Casing capping double lock type supper quality size 15 mm width ISI marked with fixing accessories complete all as specified and directed.
52Supply and fix modular type gang box(3 module for one socket and one switche) suitable for 5/15amp 6pin including plate cover plastic sunken box etc including suitable size of switches and sockets complete all as specified and directed.
53M&L earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc complete all as specified and directed.
54Taking down storage water heater 25 ltrs capacity from wall for repair/replacement of unserviceable parts and refixing with fasterners Nuts and washers the same after repair work complete all as specified and as directed.
55M&L for replacement of thermostate 0-60 degree as per sample in water geyser 25/50 litre capacity ISI Make as per sample complete all as specified and directed.
56M&L for replacement of heating element 1.5KW,Triangular/round type as per sample complete all as specified and directed.
57M&L for replacement of heating element 2 KW with complete assembly of any model and type as per site requirement /sample complete all as specified and directed.
58Material and Labour for disconnecting from electric and water mains and dismantling the unserviceable gyeser base assembly and replacing the new base assembly 6/9 holes with rubber gasket for 25 Ltrs capacity of any make and refixing in original place including recoonecting of electric and water supply mains including testing complete all as specified and directed.
59M&L for replacement of geyser outer body cover of 25 Ltr capacity made out of 16 SWG powder coated complete with all connected accessories suitably fitted with existing wall complete all as specified and directed.
60M&L for replacement of geyser tank stainless steel suitable for 25 Ltr capacity geyser complete all as specified and directed.
61M&L for replacement of PVC connection with brass inserts suitable for hot/cold water, 60 cm long (for hot and cold water inlet and outlet) having PTMT nuts with washer complete all as specified and directed.
62S & F in replacement of bottom cover suitable cylindrical type geyser as per existing required as per site for 25 Ltrs capacity complete all as specified and directed.
63Dismantling and opening storage tank of geyser 25 litre capacity to identify the leakage ,repair the spot by suitable welding carefully including making good insulating material, assembling and testing complete all as specified and as directed by Engr-In-Charge.
64S & F in replacement of indication lamp red and green (pilit type ISI marked) for 25 Ltrs water heater complete all as specified and directed.
65Supply and fixing in replacement of PVC insulated flexible copper conductor cable 40/0.0076 size 3 core suitable for 650 volts grade complete all as specified and directed.
66S & F in replacement of glass wool in any capacity of geyser complete all as specified and directed.
67Taking down ceiling fan complete any type size from existing location and cleaning body blades etc including servicing, greasing,oiling,replacing wornout bearing ,bush and refixing the same at site complete all as specified and directed.
68All as per item No 67 above but for Exhaust fan.
69All as per item No 67 above but for wall/floor mounted fan .
70Rewinding unserviceable ceiling fan 1200/1400 mm Sweep from site by strip opening,cutting removing the burnt winding from starter cleaning the slots and rewind the same with original guage of super enameled copper winding wire, insulation materials and all accessories & varnishing etc replacement of service wire copper twisted size 23/0.0076 including reassembling the fan complete all as specified and directed.
71All as per item No 70 above but for Exhaust fan 300 mm sweep.
72All as per item No 70 above but for wall/floor mounted fan 450 mm sweep.
73M&L Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
74Material and Labour for Replacement of old unserviceable fan blades, (ISI Marked), suitable for 1200mm sweep ceiling fan duly painted in white/brown by using spray gun method(fully furnished) complete all as specified and directed.
75Material and Labour for Repalcement of old unserviceable down rod of ceiling fan of dia 20mm bore \\"medium grade\\" complete with split pin, hanging clamp and rubber real (length of rod not less than 45cm and not more than 60cm) dully painted in white/brown by using spray gun method (fully furnished) complete all as specified and directed.
76Supply and Fix cable PVC insulated and overall sheathed with flexible copper conductor cable of size 0.5 sqmm,3 core cut to size of approx 0.30 metre from block of fan to ceiling rose complete all as specified and directed.
77Material and Labour for Replacement of old unserviceable gun metal bush of ceiling fan including neceassry laith, Grinding and welding work complete all as specified and directed.
78Material and Labour for Replacement of old unserviceable shackle assembly kit (Rubber real -01, MS split clamp two Nos, nuts and bolts washers- 2 Nos & split pin -02 Nos) suitable for ceiling fan of 1200/1400mm sweep complete all as specified and directed.
79Material and Labour for Replacement of old unserviceable steel screw of size 5mm to 8mm (to be used for fixing of fan blade) complete all as specified and directed.
80Material and labour in replacement of 1200mm sweep BEE 5 star rated, Ceiling fan with Brush Less Direct Current (BLDC) Motor, Class of insulation : B, power factor not less than 0.9, service value (CMM/W) minimum 6.85, having 4 aerodynamically designed blades from high quality metallic material painted smooth for maximum Air delivery not less than 230 CMM,350 RPM (tolerance as per IS:374-2019), THD less than 10%,including remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nuts bolts, washers, temperature rise =75 degree C (maximum), insulation resistance more than 2 mega Ohm, suitable for 230V, 50 Hz, single phase AC supply complete all as specified and directed.
81Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed.
82Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers complete all as specified and directed.
83Supply and fix Ventilation fan PVC (250 mm Sweep) with louvers and acessories complete all as specified and directed.
84Supply and fix Ventilation fan PVC (200 mm Sweep) with louvers and acessories complete all as specified and directed.
85Material and Labour for replacement of old unserviceable capacitor AC 400/415 volts 2.5 mfd (ISI marked) complete all as specified and directed.
86Material and Labour for replacement of old unserviceable capacitor AC 400/415 volts 3.15 mfd (ISI marked) complete all as specified and directed.
87Supply and installation in replacement of display boards of approx size 2000mm x 600mm x 10mm stencil-cut GI fascia normal flat letters backed with acrylic ensuring the text glows cleanly from the internal LEDs , internal structural framework using heavy-duty MS/GI hollow tubular sections (16-gauge). Includes full-seam welding, joint grinding, and application of 2 coats of anti-rust zinc-chromate primer followed by 2 coats of epoxy enamel paint. GI Fascia & Flat Luminous Letters 18-gauge (1.2mm) GI sheet, pan-formed into a seamless box. Normal flat letters to be precision laser-cut into the GI sheet and backed with 3mm UV-stabilized cast acrylic. Board and cut-outs to be painted with automotive PU paint to ensure letters glow uniformly with LED backlight. Exact text, font, and paint specifications will be directed by the Engineer-in-Charge. Internal LED Illumination of high-brightness, IP67-rated LED modules (SMD 2835 or 5050, >100 lumens/watt) with 160-degree wide-angle optical lenses. LEDs to be mounted on the internal back panel to provide uniform, shadow-free illumination through the flat acrylic-backed letters. with outdoor-rated IP67 Constant Voltage 12V DC SMPS with built-in overload protection, sized with a minimum 20% safety margin. Includes all internal FRLS multi-strand copper wiring, PVC flexible conduits, and waterproof IP68 gel connectors. Safe hoisting, alignment, and secure wall/structure mounting of the complete sign board. Includes the use of SS 304 grade fasteners, heavy-duty chemical anchors or rawl bolts, and drilling 3mm weep holes at the bottom of the GI box for moisture drainage complete all as specified and directed.
88Taking down carefully copper / aluminum two core sub main wiring of sizes 4/6 Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and directed.
89M&L in repairs,two single core PVC insulated cable with copper conductor multi stranded 4 Sqmm duly drawn through and including concealed PVC conduit suitable size as sub main with continuous earth wire 6 Sqmm size and connecting to common earth dolly complete all as specified and directed.(Flexible Copper Wire Used In FRLS)
90S&F in repairs,LED tube light batten, 20W(+) 2% LED 6000K (4 ft.), 230 volts AC,Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed.
91Supply and fix exhaust fan, heavy duty steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers complete all as specified and directed.
92S& fixing LED flood light luminarie 120 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed.Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost to height upto 25 mtr
93Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed.
94Add to item No 93 for each additional 1.5 mtr or part their of in depth beyond the first 1.5 mtr
95Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cm apart complete all as specified and directed.
96Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
97M&L for sand cushioning to XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and this then gently punned down to a thick of 10 cm above the top the upper most cable complete all as specified and directed.
98Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm complete all as specified and directed.
99Supply,Laying,Connecting and testing in repairs cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 35 Sqmm 3.5 core complete all as specified and directed.
100Supply and fix steel pole tubular swaged 9 metres long complete with cast iron base plate , finialtaper plug , bolts , nuts and screws as specified type 410 SP-22 complete all as specified and directed.
101Supply and errection in true vertical position 6 mtr long MS pole on pcc foundation suitable for 47 m/s wind speed with 4-8, 590mm PCD of foundation on j anchor bolts consctruction complete with MS base plate of 300mmx300mmx10mm at bottom and swages from base to top in such manner that 114.3mm x 3.65mm upto 3 metres, 88.9mm x 3.25mm upto 1.5 metres , 76.1mm x 3.25mm upto 1.5 metres, above base plate with arm to fix solar street light at top and final tape plug, bolts, nuts, washers and screws incl painting with black bituminous paint two coat over one coat or red oxide primer after errection complete and marking pole number on pole complete all as specified and directed.Note : (i) Earth work and PCC foundation work shall be measured and paid separately.(ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost.
102M & L cement concrete in foundation filling and mass concrete type B2 1:3:6 (40mm graded stone aggregate) complete all as specified and directed.
103M & L cement concrete in foundation filling and mass concrete type B2 1:4:8 (40mm graded stone aggregate) complete all as specified and directed.
104Supply and fixing in repair/replacement of solar street light fittings with integrated 35 Watt LED street light system with solar PV Panel 100 WP, integrated LED fitting with Li-Ion Battery 11.1 V 17 Ah , MPPT based solar charge controller,Motion Sensor and tubular pole of height 5 Mtrs complete all as specified and directed.
105Supply and fix in replacement non-metallic junction box/street light box with three phase aluminium bus bar of suilable for 415 Volt , 50 Hz electric supply conforming to IP65 wall / pedestral mounted and including MCB SPN 06 Amps complete all as specified and directed.
106S& fixing LED flood light luminarie 70 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection acomplete all as specified and directed.Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost to height upto 25 mtr
107M& L for preparation of trench for cable laying of size 300mm x 450mm x 10 m long including excavation & earth work in any type of soil brick work in CM 1:4, PCC work in 1:2:4 type B-1 using 20mm graded stone aggregate, plaster in CM 1:4 finished even & fair complete all as specified and directed.
108Supply and fix cable duct cover made of MS of size 300mm x 450mm x 1m of thickness 3.0 mm complete all as specified and directed.
109S & F rubber insulation mat of size 1.8 mtr x0.9mtr wide 2 mm thick red/blue colour ISI marked embossed for up to 33 KV as per latest IS complete all as specified and as directed by Engineer-in-Charge.
110Supply,Laying,Connecting and testing in repairs cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 120 Sqmm 3.5 core complete all as specified and directed.
111All as per item No 110 above but Size 70 sqmm 3.5 core.
112All as per item No 110 above but Size 50 sqmm 3.5 core.
113Boring of Holes under road, Pavement, hard Standing by trenchless technology using ultra Sound technique and necessary machine with HDPE Pipe, PN 10,100 mm dia complete all as specified and directed.
114Supply, laying and fixing in position in repairs galvanized iron pipe 80 mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches duly painted with two coat of black metallic paint after a primer coat of red oxide complete all as specified and directed.
115All as per item No 114 above but 50 mm dia.
116All as per item No 114 above but 40 mm dia.
117M&L for cable end termination kit out door, heat shrinkable type suitable for XLPE/ PVC cables of size 6 Sqmm to 16sqmm 4 core core with working voltage 1100 volts incl necessary excavation returning filling & removal complete all as specified and directed.
118All as per item No 117 above but Size 25-35 sqmm 4 core.
119All as per item No 117 above but Size 50-120 sqmm 3.5 core.
120M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 6 Sqmm to 16 Sqmm 4 core with working voltage 1100 volts complete all as specified and directed.
121All as per item No 120 above but Size 25-35 sqmm 4 core.
122All as per item No 120 above but Size 50-95 sqmm 3.5 core.
123S&F in repairs MCCB 4 pole 415 volts fixed type 250 Amps with braking capacity 25KA after taking out old U/S one complete all as specified and directed.
124S&F MCCB 4 pole 415 volts in repairs,fixed type 200 Amps with braking capacity 16 KA.after taking out old U/S one complete all as specified and directed.
125S&F in repairs MCCB 3 pole 415 volts fixed type 160 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed.
126S&F in repairs MCCB 3 pole 415 volts fixed type 125 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed.
127S&F MCCB 3 pole 415 volts in repairs,fixed type 63 Amps with braking capacity 16 KA after taking out old U/S one complete all as specified and directed.
128S&F sheet metal enclosures DB Double door Verticle distribution type, 06 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directed.Note : - MCCB shall be measured and paid separately
129Removing all connections from LT panel having feeders upto 04 Nos ( Total of incoming and outgoing) , any capacity, indoor or outdoor type, fpr repairs/ servicing. Cleaning properly all parts and removing dust, carbon deposits etc. Removing U/S thimbles if any of connections. Refixing serviceable items to the panel and making all connections including testing for proper functioning of the panel as per standard engineering pactice, complete all as specified and directed. Note :- Old U/S items will be provided against respective items separately.
130M&L for Painting of any size , any make LT panel after removing old dust partical,oily porytion by rubbing with sand paper with spary pump, and writing /digital printing ., Capacity Descripton, date of installation,etc complete all as specified and directed.
131Supply and fixing as in repair / replacement of UNSV Aluminum thimbles of size 10sqmm to 25sqmm as per site requirements, complete all as specified and directed.
132Supply and fixing as in repair / replacement of UNSV Aluminium thimbles of size 35Sqmm to 70sqmm as per site requirements, complete all as specified and directed.
133M&L danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT, 20x15 cm size complete all as specified and directed.
134Supplying and fixing PVC conduit 25 MM dia along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed.
135Supply, installing testing and commissioning in replacement of size 900x900x450 (Apprx)factory made and tested (Including CPRI test cetified) outdoor type floor mounted LT panel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chamber with insulated AL busbar of rating 1.5 times the incomer MCCB for phase installed on porcelin/SMC insulators. The panel shall be dust and vermin proof IP-64 class protection and made out of 3.15 mm thick CRCA MS sheet and angle iron frame 40x 40x 6mm thick frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with aproaches for cable entry with double door shutter and locking arrangements including internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size comprising of following:-INCOMING-(i) Mains MCCB 4 pole 400 Amps 50 KA with adjustable setting, 415 Volts with breaking capacity 36 KA. -01 No.(ii) Digital type voltmeter 0-500 volts and with selector switch-01 No.(iii) Digital Amp meter with CTs & built in selector switch-01 No.(iv) Indication lamp RYB-01 Set.OUTGOING-(i) MCCB 3 pole 250 Amps,, 415 Volts with breaking capacity 25 KA.-01 No.(ii) MCCB 3 pole 125 Amps, 415 Volts with breaking capacity 25 KA.-03 No. (iii) MCCB 3 pole 100 Amps, 415 Volts with breaking capacity 25 KA.-02 No. Note: Drawings for LT panel shall be got approved from GE before procurement.
136M & L for earthing with steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less tha 1.5 mtr deep below normal grund level connected to galvanized iron strip size 32 x 6 mm as earthing lead by means of nuts, bolts and washers of steel after wlding of GIstrip to earth electrode to the full length of earht plate, 40mm dia GI tubing lightgrade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover ofsize 30x30 cm made of RCC 1:3: with suitable handle, angle iron frame made of angle iron of size 40x40x4m, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetables soil to the remaining 10% removal of surplus soil and retruning filling in all as required at site including test point made outof steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and complete all as specified and directed.
137M&L for Design ,development ,supply commisiong and testing burnished metallic brown 99.99% pure copper material specially develpoed for earthing purpose T point terminal exothermic/ nut bolt/ breezing . ground tubular effective chemical earthing (CPRI tested for 25KA current capacity for LT line ) highly anticorrosive long life eletrode with and including adequate protective coating to withstand servere weather condition in the earth pit of the standard size comprising of 40 mm 3m long copper rod as primary conductor and hollow copper tube of 80 mmx 3 m long with alosing base plate of 80 mm secondary conductor to install with suitable connecting terminal cofirming of IS 3043 1987 specification highly conductive packing material to be filled in earth pits for providing uniform low resisitivity anticorrosive ,hygroscope medium around the earth system for improving the efficiency of current dissipation with cystalline conductive mixture CCM 25 kg per bag sufficient quantities required at site complete RCC earthing pit cover material and labour complete bfc compound specified and as per ic 62561 acceptance chemical test Leaching, sulphur determination, corrosion, resistivity along with CPRI and chemical compound test report complete all as specified and directed. Note :-1. Excavation / drilling hole in hard rock is included in the rate quoted incld. T&P2. Min. resistance for earthing pit shall be less than 1 ohm.3. Drilling or earth work shall be included in the overall cost quoted by the contractor.
138Supply and fix copper strip 20mm x 3.15 mm complete with insulators and fixing screws etc for roof/wall above ground level including removing u/s strips complete all as specified and directed.
139Supply and fix aluminium strip 25 mm x 4 mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground level including removing u/s strips complete all as specified and directed.
140Supply and fix single pointed air termination aluminium rod,12 mm dia, 300 mm long all as specified and directed.
141S&F porcelain strip holder on wall and roof of suitable size including removing broken u/s one complete all as specified and directed.
142M&L 32 mm GI pipe light grade of 1.3 mtr piece fixing in PCC cubical and complete connection of existing air termination rod complete all as specified and as directed,
143M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping and necessary form work, weathering slightly rounded or chamfered angles and throating etc complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57429044
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 29 Lakhs
LAST DATE 30-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maintenance Of Lt Panel, Mccbs, Earthing, Summer Appliances, Hot Water Appliances, Hot Water Appliances, Internal Electrification And Mes Installation At Af Stn Aastha Complex & 5 Aflu Under Aor Of Ge (Af) Faridabad
Basic Detail
Tender No GE (FBD)/AF-T-62/2026-2027
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 09 Sep 2026
Submission Date 30 Sep 2026
Open Date 01 Oct 2026
Finance
Tender Value 29 Lakhs
Tender Fee 500
EMD 58000
Exemption Available
Document List
97f5bc07-61e7-4c51-a405-9cec5cd4a8f4.html
BOQ_883899.xls
Tenderdocu62.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Oct 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

97f5bc07-61e7-4c51-a405-9cec5cd4a8f4.html

xls

BOQ_883899.xls

pdf

Tenderdocu62.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail