Tender For special Repair To Roof Treatment Wk At Block No P-53 (Qtr No 10,12,14 & 16), P-54 (Qtr No 18 & 20), P-72 (Qtr No 2 & 4), P-73 (Qtr No 2 & 4), P-75 (Qtr No 2 & 4), P-76 (Qtr No-2 & 4) & P-77 (Qtr No-2 & 4) At Nalwa Fafa And Constr Of Securi
Tender Overview
Project Description
Tender for special Repair To Roof Treatment Wk At Block No P-53 (Qtr No 10,12,14 & 16), P-54 (Qtr No 18 & 20), P-72 (Qtr No 2 & 4), P-73 (Qtr No 2 & 4), P-75 (Qtr No 2 & 4), P-76 (Qtr No-2 & 4) & P-77 (Qtr No-2 & 4) At Nalwa Fafa And Constr Of Security Wall Surrounding Field Area Family Accn Thimmaya Park Under Age B/R-Ii Of Ge (East) Jalandhar Cantt (Tender Id No 2026_Mes_788134_1)
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brick tiles single layer as in roof covering, complete all as directed by Eng-in-charge. |
| 2 | Demolition of mud in roofs any thickness including plastering and leeping (whether full thickness removed or only a part thereof), complete all as directed by Eng-in-charge. |
| 3 | M&L for PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in benching, roof padding, roof kerbs or mud stops, coping etc rounded or chamfered on edges, complete all as specified and as directed. |
| 4 | M&L for 10mm thick cement plaster in cement mortar (1:3) mixed with integral water proofing compound in the proportion recommended by manufacturer, on concrete roof surfaces finished even and fair, including cleaning the roof top by scraping down with water etc, complete all as specified and as directed. (WPC shall be measured and paid separately under appropriate item of this BOQ). |
| 5 | Cleaning the surface and made free of dirt, foreign particle, laitance followed by grinding all all protrusion to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expiation contraction. Cutting the grooves with suitable cutter machine in V-groove filled with repairs mortar/ microconcrate/ general purpose grout as recommended proportionally as per recommendation of manufacture. Making of Gollas at all the corners with polymer modified mortar (1:4) cement sand with 3.5% acylic of cement weight, complete all as directed by Eng-in-charge. |
| 6 | Supply and applying high build elastomeric waterproofing coating based on pure hydrophobic polyurethane cold applied of spray/brush applied, membrane with an elongation of 280% and tensile strength of 2.7N/mm2 as per ASTM D 2370, crack bridging ability of 3mm, no leakage upto 5 bars of water pressure as per DIN 1048, min 88% solid content. The system includes final base preparation, epoxy primer 1:1 (Resin; harder) application with 100% water dilution and Pure polyurethane application in 2 coats with a total min consumption of 1.25 kg per Sqm. Application should be done with Graco sprayer by a company authorised applicator”, complete all as specified and as directed. |
| 7 | M&L for 40mm thick brick tiles laid on mud/cement surface and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement, complete all as specified and as directed. |
| 8 | Ditto all as per item no. 07 above, but except tiles, complete all as specified and as directed. |
| 9 | Demolition of brick work as in walls/parapet wall,s removing grass fungus weed, roots of trees completely, grown on roof/wall surfaces, complete all as directed by Eng-in-charge. |
| 10 | M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6 M mean radius built in CM (1:6), complete all as specified and as directed. |
| 11 | Taking down cement plaster of any description thickness including raking out joints hacking for key scrubbing down with water, complete all as directed by Eng-in-charge. |
| 12 | M&L for 15mm thick cement plaster on brick or concrete surfaces in cement mortar (1:4) mixed with integral water proofing compound in the proportion recommended by manufacturer, surfaces finished fair and even, complete all as specified and as directed. (WPC shall be measured and paid separately under appropriate item of this BOQ). |
| 13 | M&L for preparation of new cement surface and applying two coats of acrylic exterior emulsion paint over a coat of wall primer applying by mechanical spray gun including filling uneven surface with putty complete all as per manufacturer instruction, complete all as specified and as directed. |
| 14 | Supply only integral water proofing compound ISI marked, complete all as specified and as directed. |
| 15 | S&F PVC (SWR) pipes 110 mm dia with single socketed in any length with rubber ring joints fixed on brick walls or laid in trenches with PCC 1:2:4 complete houching with bedding including demolition and braking up existing pipes with fittings, complete all as specified and as directed. |
| 16 | S&F PVC (SWR) bends 110 mm with access door, complete all as specified and as directed. |
| 17 | M&L Galvanised iron water tubing 15 mm bore, medium grade with & including all fittings fixed to wall, ceilings and or laid in floors etc including taking down the existing tubing, complete all as specified and as directed. |
| 18 | Ditto all as per srl item No.17 above above, but for 20mm bore tube, complete all as specified and as directed. |
| 19 | Demolition of reinforced cement concrete in ground floors and paving n.exc 15 cm thickness (reinforcement to cut as required to facilitate demolition), complete all as directed by Eng-in-charge. |
| 20 | M&L for reinforced cement concrete (1:2:4) type B-1 (20 mm graded aggregate) slab supported on wall, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. |
| 21 | M&L for MS TMT bars 10 mm and over dia and cut to length, bent to shape required including cranking bending spirally for hooping for clos hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed. |
| 22 | Ditto all as per item no. 21 above, but 6mm dia to 8mm dia as in stirrups, complete all as specified and as directed. |
| 23 | M&L for form work to soffits of suspended slabs such roof slabs, floor slabs, shelves, landings and similar work, not exceeding 200mm thick (horizontal or slopping) rough finished surfaces of concrete flat or shelfs etc, complete all as specified and as directed. |
| 24 | S&F in repair 500 ltr UV protected antimicrobial triple layer (white) coating rotational moulded polythylene water storage tank in white colour (Cylindrical vertical with closed top) hosted and fixed in position with 20mm ball valve high pressure, PTMT with polythene float and fly nut including dismantling of existing tank of any description, complete all as specified and as directed. Make: shintex |
| 25 | Uprooting of trees,grass,bushes etc from brick wall/roof tiles or any surfaces of bldg including dismantling the requried brick work /rooftiles/mud concrete etc for uprooting the vegetation etc and make good the same to match existing surfaces with same material or concrete 1:2:4 type B-1 after pouring the chemical (which destroy the growth of vegetation to place where vegetation removed).The rate shall include for scaffolding or any other arrangment required during this process upto 10 mtr height, complete all as directed by Eng-in-charge. |
| 26 | Dismantling wrought iron or mild steel work of any description not otherwise provided, complete all as directed by Eng-in-charge. |
| 27 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and nexc 1.5 m in depth and getting out soft/loose soil, complete all as directed by Eng-in-charge. |
| 28 | M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as foundation, filling and mass concrete, complete all as specified and as directed. |
| 29 | M&L for RCC M-25 (Design Mix) as in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns, etc: basement slabs, under-reamed piles and mass concretel, complete all as specified and as directed. |
| 30 | M&L RCC M-25 (Design Mix) as in columns, pillars, piers, posts and struts , complete all as specified and as directed. |
| 31 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) and similar work vertical or to batter, complete all as specified and as directed. |
| 32 | Form work to sides of pillars, posts, struts, piers, columns and stanchions square or rectangular for rough finished surface of, complete all as specified and as directed. |
| 33 | Form work to sides and soffits of beams, chajjas and the like for rough finished surfaces, complete all as specified and as directed. |
| 34 | Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cm 1:6, complete all as specified and as directed. |
| 35 | M&L Rendering 15mm thick CM 1:6 on fair faces of brick work or concrete surfaces to be finished even and smooth, complete all as specified and as directed. |
| 36 | M&L for preparing surfaces on new surfaces and distempering on preparing surfaces of walls with 2 Coat of cement paint white or tinted over a coat of primer, complete all as specified and as directed. |
| 37 | S&F for rolled mild steel work as in joist, channel,angle, or tee sections fixed independently without connecting plates etc, of Fe-410 W (Gde e 250) quality B, complete all as specified and as directed. |
| 38 | M&L for paint over new steel surface, 2 coat of Synthetic enamel (ordinary tint) over a primer (Red oxde, zinc chrome), complete all as specified and as directed. |
| 39 | S&F Galvanised 2 strand steel barbed wire 2.24 mm dia with 2 mm barbs at 75 mm spacing and straining and fixing to posts of any type including securing or tying at crossing with and provision of GI wire staples or steel pins etc complete all as specified and directed by Engr-in-Charge. |
| 40 | Returning ,filling in including spreading, levelling,watering and ramming in layers n. exc 25 cm thick each complete all as specified |
| 41 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender