Tender for Day To Day Minor Addition & Alteration Of Electrical Installation Work In West C Us For Fy 2026-27
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group-A |
| 3 | Group-B |
| 4 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 5 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 7 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 8 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 9 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 10 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 11 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel conduit/ FRPVC Trunking as required. |
| 12 | 3 x 2.5 sq. mm |
| 13 | 3 x 4 sq. mm |
| 14 | 6 x 4 sq. mm |
| 15 | 3 x 6 sq. mm |
| 16 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 17 | 20 mm |
| 18 | 25 mm |
| 19 | 32 mm |
| 20 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 21 | 20 mm |
| 22 | 25 mm |
| 23 | 32 mm |
| 24 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 25 | 75 mm X 75 mm X 60 mm deep |
| 26 | 100 mm X 100 mm X 60 mm deep |
| 27 | 150 mm X 150 mm X 60 mm deep |
| 28 | 200 mm X 150 mm X 75 mm deep |
| 29 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 30 | 5/6 A Switch |
| 31 | 15/16 A Switch |
| 32 | 3 pin 5/6 A socket outlet |
| 33 | 6 pin 15/16 A socket outlet |
| 34 | Bell Push |
| 35 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 36 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 37 | Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in surface / recess etc. as required. |
| 38 | 1 or 2 Module (75mmX75mm) |
| 39 | 3 Module (100mmX75mm) |
| 40 | 4 Module (125mmX75mm) |
| 41 | 6 Module (200mmX75mm) |
| 42 | 8 Module (125mmX125mm) |
| 43 | 12 Module (200mmX150mm) |
| 44 | Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 45 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 46 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 47 | Upto 450 mm sweep |
| 48 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 49 | 100 A,30KA, FP MCCB |
| 50 | 125 A,36KA, FP MCCB |
| 51 | Providing and fixing 100A, 16KA, TP, MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 52 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 53 | 8 way , Double door |
| 54 | 12 way , Double door |
| 55 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 56 | For 8 way, Double door SPN MCBDB |
| 57 | For 12/14 way, Double door SPN MCBDB |
| 58 | Supplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, with provision of 100 amps 4 Pole 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB's/ MCCB) including sign writing on DB (matter: AC / Normal / Emergency Power) etc. as required. |
| 59 | 8 way (4 + 24), Double door |
| 60 | 12 way (4 + 36), Double door |
| 61 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB/MCCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 62 | Supplying and fixing of following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (matter: AC / Normal / Emergency Power) etc. as required . |
| 63 | Single Pole, 5-32A |
| 64 | Double Pole, 32A |
| 65 | Triple pole and Neutral, 32A |
| 66 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 67 | Supplying and fixing TP sheet steel enclosure on surface/ recess but without MCB complete with connections, testing and commissioning etc. as required |
| 68 | Supplying and fixing 20A, 240V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. |
| 69 | Supplying and fixing 20A, 415V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 70 | Supplying and fixing 30A, 415V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 71 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 72 | LED Down lighter (SMD Type) (System lumenefficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim |
| 73 | 12 -15 watt |
| 74 | Brush Less Direct Current (BLDC) Fan with RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/ HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 75 | 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum) |
| 76 | 1400mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 242 CM/Min (Minimum) |
| 77 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 78 | 4 X 16 sq. mm |
| 79 | 4 X 25 sq. mm |
| 80 | 3½ X 35 sq. mm |
| 81 | 3½ X 50 sq. mm |
| 82 | 3½ X 70 sq. mm |
| 83 | 3½ X 120 sq. mm |
| 84 | 3½ X 150 sq. mm |
| 85 | 3½ X 240 sq. mm |
| 86 | 3½ X 300 sq. mm |
| 87 | 3½ X 400 sq. mm |
| 88 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (Make: Dowells/Commet /Gripwell/ Raychem) |
| 89 | 4 X 16 sq. mm |
| 90 | 4 X 25 sq. mm |
| 91 | 3½ X 35 sq. mm |
| 92 | 3½ X 50 sq. mm |
| 93 | 3½ X 70 sq. mm |
| 94 | 3½ X 120 sq. mm |
| 95 | 3½ X 150 sq. mm |
| 96 | 3½ X 240 sq. mm |
| 97 | 3½ X 300 sq. mm |
| 98 | 3½ X 400 sq. mm |
| 99 | Making hole for installation of exhaust fan of size upto 420 mm sweep by demolishing brick work manually/by machine means including disposal of malba and making good the wall by plastering etc. as required. |
| 100 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams, including painting the exposed portion of loop, all as per standard design complete. |
| 101 | Supplying and fixing extra down rod of 30 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 102 | Supplying and fixing following rating, double pole, 240 V, MCB 'C' Series in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 103 | Supplying and fixing following rating, four pole, 415V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 104 | Supplying and laying of one number PVC insulated and PVC sheathed XLPE armoured aluminium conductor cable of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 105 | 4 X 10 sq. mm |
| 106 | 4 X 16 sq. mm |
| 107 | 4 X 25 sq. mm |
| 108 | 4 X 35 sq. mm |
| 109 | 3½ X 50 sq. mm |
| 110 | 3½ X 70 sq. mm |
| 111 | 3½ X 120 sq. mm |
| 112 | 3½ X 150 sq. mm |
| 113 | 3½ X 240 sq. mm |
| 114 | 3½ X 300 sq. mm |
| 115 | 3½ X 400 sq. mm |
| 116 | Supplying and laying of one number PVC insulated and PVC sheathed XLPE armoured aluminium conductor cable of following size on cable tray/ open duct/ wall as required. |
| 117 | 4 X 10 sq. mm |
| 118 | 4 X 16 sq. mm |
| 119 | 4 X 25 sq. mm |
| 120 | 3½ X 35 sq. mm |
| 121 | 3½ X 50 sq. mm |
| 122 | 3½ X 70 sq. mm |
| 123 | 3½ X 120 sq. mm |
| 124 | 3½ X 150 sq. mm |
| 125 | 3½ X 240 sq. mm |
| 126 | 3½ X 300 sq. mm |
| 127 | 3½ X 400 sq. mm |
| 128 | Supplying and laying of one number PVC insulated and PVC sheathed XLPE armoured aluminium conductor cable of following size in the existing RCC / HUME/ METAL/HDPE or different pipe as required. |
| 129 | 4 X 10 sq. mm |
| 130 | 4 X 16 sq. mm |
| 131 | 4 X 25 sq. mm |
| 132 | 3½ X 35 sq. mm |
| 133 | 3½ X 50 sq. mm |
| 134 | 3½ X 70 sq. mm |
| 135 | 3½ X 120 sq. mm |
| 136 | 3½ X 150 sq. mm |
| 137 | 3½ X 240 sq. mm |
| 138 | 3½ X 300 sq. mm |
| 139 | 3½ X 400 sq. mm |
| 140 | Dismantling of old damaged DB/TPN Switches/ loose wire boxes along with all accessories as required. |
| 141 | Supplying and laying of following size HDPE Pe63 PN6 pipe conforming to IS 14930, Part-II (IS 4984:2016) inclouding jointing, etc. laying in the existing trench or trenchless complete as required. |
| 142 | 110mm |
| 143 | 140mm |
| 144 | Supplying and fixing 240mm X 130mm X 95mm size weather proof PVC/Polymar box with side hinged door, PVC/Polymar box comprising four way 25A bolted type connector terminal including connections, testing etc. complete as required |
| 145 | Supplying and fixing 450mm X 375mm X 220mm size weather proof rectangular shape PVC/ Polymar box with side hinged door, PVC/Polymar box comprising four way bolted type connector terminal for three phase connections, including testing and commissioning etc. complete as required. |
| 146 | Supplying and fixing 600mm X 500mm X 250mm size weather proof rectangular shape PVC/ Polymar box with side hinged door, PVC/Polymar box comprising four way bolted type connector terminal for three phase connections including testing and commissioning etc. complete as required. |
| 147 | Making the corecut out with boki of upto 150mm dia inside the soil including making good the same etc. as required. |
| 148 | Fault Locating of LT cable with the help of fault locating machine, including identification and making of fault complete as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysSep 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender