Tender For Retrofitting (Tactile Flooring, Railings, Signage For Disabled Persons & Parking) In Judicial Court Complex Jalalabad, District Fazilka Under Head 4059-Col-80-51-Construction-63-02-53 Creation/ Up-Gradation Of Infrastructure Of Judicial Co
Tender Overview
Project Description
Tender for Retrofitting (Tactile Flooring, Railings, Signage For Disabled Persons & Parking) In Judicial Court Complex Jalalabad, District Fazilka Under Head 4059-Col-80-51-Construction-63-02-53 Creation/ Up-Gradation Of Infrastructure Of Judicial Court (14Th Fc)
BOQ
| Sl. No. | Item Description |
| 1 | Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority: EXECUTIVE ENGINEER, CONSTRUCTION DIVISION, PWD B&R BRANCH FEROZEPUR Name of Work: Retrofitting (Tactile Flooring, Railings, Signage for Disabled Persons & Parking) in Judicial Court Complex Jalalabad, District Fazilka under Head 4059-COL-80-51-Construction-63-02-53 Creation/ Up-gradation of Infrastructure of Judicial Court (14th FC) Contract No: Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Work Name Item Code / Make Quantity Unit RateRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Upgradation of Tactile Flooring/ Guide Path, door hardware, resting facility etc inside Building etc for PwDCutting of floor topping of concrete / Kota Stone / any kind of marble/ tile floor depth up to 50mm with the help of mechanical cutter and chisel (with due care so that surrounding floor should not be damage) to lay the tactile flooring 300mm wide including cost of providing and laying 25mm to 28mm thick cement concrete 1:2:4 as per requirement complete as per specification, Harmonised guidelines for PwD and as desired by Engineer-in-charge. |
| 3 | Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability) |
| 4 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 5 | Malwa shifting |
| 6 | Upgradation of MS Railing on Existing Staircases and Ramps for PwDProviding & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect. |
| 7 | Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 8 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 9 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 10 | Providing and fixing acrylic Braille indicators for handrails of the approved design and make having Braille dots raised 0.5mm above base plate, to be installed at the specified locations as per the directions of the engineer in charge complete as per design/specifications and guidelines as per the entire satisfaction of the the Engineer-in-charge (N5) |
| 11 | Providing and fixing of high intensity reflective conspicuity tape 25 to 50mm width, on edges of treads in staircase including, cutting, pasting etc. of make 3M or equivalent brand complete in all respect to the entire satisfaction of Engineer- in-charge (NS) |
| 12 | Upgradation of Informatory Signage, Safety Signage etc for PwDProviding and Installation of Safety signage as per guideline for person with disability made of retro reflective sheeting as per colour specified and writing matter will be of same material in white fixed / pasted over 4mm thick aluminum composite sheet, including cost of writing matter with braille also firmly fixed on wall with nylon fastener, brass screw and washer complete as per specification and as desired by engineer in charge. |
| 13 | Providing and Fixing Acrylic Hanging Board 4.5'X3' (Both side as per sample |
| 14 | Providing and fixing of acrylic, non-glare, tactile Each audi pictorial building layout as per the approved size, design and make, having 6mm thick acrylic non plare base plate of the approved colour and non- glare acrylic cut out symbols and upper case Sans Serif letters of 12mm height, raised 3mm above base plate and Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. The map to be installed at the specified location as per accessibility standards, shall be oriented to the position of the viewer and to be installed at a height of 800 mm from the finished ground/ floor level and using the necessary hardware specified by the manufacturer and to be installed up to the height of 800 mm from the finished ground/ floor level and using the necessary hardware specified by the manufacturer and to be installed complete as per design/specifications and guidelines as per the entire satisfaction of the the Engineer-in-charge (NS) |
| 15 | Providing and fixing Multilingual and tactile Emergency evacuation map of each floor indicating the current position of the viewer saying \\"YOU ARE HERE\\" of 15mm height letters in red with white background, indicating the emergency exits, locations of fire extinguishers etc. Signs shall have a solid header with the text \\"EVACUATION PLAN\\" in contrasting uppercase letters no less than 3/4\\" in height. The size of the board shall be 2ft x 2ft and shall be installed at a height of 1200mm from FFL and shall be oriented to the position of the viewer as per the direction of the site engineer complete as per design/specifications and guidelines as per the entire satisfaction of the the Engineer-in-charge (NS) |
| 16 | Providing & Fixing of Pictorial layout plan of size 900mmx600mm as approved design, made of 3mm thick acrylic non glare base plate and non glare cut out symbols with grade One Braille on which individual facility points, like inquiry, reception, restrooms, medical room/ first aid, cafeteria or breakout area, lounge, meeting room, conference room etc. present the respective floors with pictograph wherever needed all in tactile raised by minimum of 1to2 mm in various colours to make it legible for seniors, partial vision impaired etc. All the facility names should be in Braille, along with English or Hindi. The entire block of tactile signs should be mounted on wall or on a slant/ inclined frame for easy. reading. The map to be installed at specified locations and installed at a height of 800mm from ground level complete in all respect as per Harmonized guideline & satisfaction of Engineer-in-charges. (N.S) |
| 17 | Upgradation of Parking Facility and Tactile Flooring/ Guide Path outside the buildingStructural steel work in angles, tees and flats, riveted or welded including cutting fixing all gusset plates, bolts, nuts, rivets, welding rod, etc. with hoisting and erecting in position :-For roof trusses, well curbs, plates and trussed girders, etc. of any span for buildings and bridges up to 15 m span. |
| 18 | Providing and fixing polycarbonate sheet sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws with EPDM seal, and the joints shall be provided with aluminium strips at top and bottom as a seal complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Pollycarbonate sheet Multiwalled 10mm thick |
| 19 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 20 | Cement Concrete 1:6:12 with 40mm gauge stone agreegate.using concrete mixture volumetric type |
| 21 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 22 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 23 | Cold twisted detormed (Ribbed/Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works,where not including in the complete rate of RCC including bending and binding placing in position complete |
| 24 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 25 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade |
| 26 | Road marking with hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads @ 0.25 kg per sqm area as per IRC:35 1997 complete as per technical clause 803 of MORT&H specifications |
| 27 | Upgradation of Accessible Toilet BlockRemoving Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled.Doors of area 3 sqm and below. |
| 28 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. |
| 29 | Factory manufactured Solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : 2202 (1999) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-30mm thick |
| 30 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect Glazing area above 0.09 sqm5.0mm thick Plate glass (INDIAN) |
| 31 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 32 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concretesurface to give an even shade Total in Figures 3324160.0 3324160.0 INR Thirty Three Lakh Twenty Four Thousand One Hundred & Sixty Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Total Cost of Routine Maintenance Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents