Health and Family Welfare Boards / Undertakings / PSU Closing in 19 days TDR #57426435

Bids Are invited for Cpm Machine (Lower Limb Continuous Passive Mobiliser) - The System Shall Support Therapeutic Movement Of The Knee And Hip, And Ankle Where Applicable, Without Requiring Active Effort From The Patient , Type: Electrically Operated

Issued by Boards / Undertakings / PSU · Muzaffarpur, Bihar
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Sep 2026
19 days left
EMD
35000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Muzaffarpur → Bihar
EMD Exemption
Available
Quantity
1

Project Description

Bids Are invited for Cpm Machine (Lower Limb Continuous Passive Mobiliser) - The System Shall Support Therapeutic Movement Of The Knee And Hip, And Ankle Where Applicable, Without Requiring Active Effort From The Patient , Type: Electrically Operated, Motorized Cpm System For Lower-Limb Rehabilitation. , Movement: Continuous Passive Flexion/Extension With Controlled, Smooth And Repeatable Movement. , Joint Rehabilitation: Knee And Hip Mobilization; Ankle Mobilization Shall Also Be Available. , Knee Range Of Motion: At Least Approximately -10° To 120° Or Wider, With Programmable Limits. , Hip Range Of Motion: At Least Approximately -7° To 115° Or Wider, With Programmable Limits. , Ankle Range Of Motion: At Least Approximately 20° To 0° To 40° Or Equivalent Clinically Suitable Range. , Speed Control: Programmable Speed Control, Preferably Adjustable Over A Range Of Approximately 0°–120°/Min Or Better. , Flexion/Extension Control: Independent Programmable Control Of Flexion And Extension Limits. , Force Control: Adjustable Force/Load Control With Force Reversal Or Safety Response In Case Of Excessive Resistance. , Pause Function: Adjustable Pause At Extension And Flexion Endpoints. , Progressive Movement: Progressive Automatic Increase Of Range Of Motion During Treatment, With Clinician-Set Limits. , Warm-Up: Warm-Up Cycles/Program Shall Be Available Before Or At The Beginning Of Treatment. , Working/Treatment Time: Programmable Treatment Duration; Preferably Up To 24 Hours Or Continuous/Repetitive Operation As Clinically Required. , Memory/Programs: Memory Function For Storing Multiple Treatment Programs/Settings; Minimum 10 Programmable Memory Locations Preferred. , Repetitions: Programmable Repetition Limits For Flexion And Extension. , Patient Comfort: Adjustable/Supportive Leg, Calf, Thigh And Foot Supports With Suitable Straps/Padding For Secure Positioning. , Adjustability: Device Shall Accommodate Different Patient Leg Lengths And Allow Ergonomic Adjustment Of Limb Supports. , Control Interface: User-Friendly Digital/Led/Lcd Control Interface For Setting And Displaying Treatment Parameters. , Remote Control: Handheld/Corded Patient Or Operator Control Shall Be Provided For Essential Functions Such As Start/Stop And Return/Comfort Position. , Safety: Emergency Stop/Quick Stop Function And Suitable Protection Against Excessive Movement/Force Shall Be Provided. , Power Supply: Suitable For Indian Mains Supply, 230 V Ac, 50 Hz, Or 100–240 V Ac, 50/60 Hz. , Construction: Robust, Durable, Easy-To-Clean Construction Suitable For Hospital/Clinical Use. , Maximum Patient Weight: Minimum 140 Kg; Higher Capacity Shall Be Acceptable. , Accessories: Necessary Straps, Limb/Foot Supports, Remote/Control Unit, And All Standard Accessories Required For Safe Operation Shall Be Supplied. , Electrical Safety: Electrical Safety Compliance As Applicable To Medical Electrical Equipment, Including Iec 60601-1 Or Latest Applicable Edition/Standard. , Quoted Model Should Comply With Ce/Us Fda & Iso 13485 Approved Certificates.

BOQ

Sl. No. Item TitleItem Description
1The system shall support therapeutic movement of the knee and hip, and ankle where applicable, without requiring active effort from the patientThe system shall support therapeutic movement of the knee and hip, and ankle where applicable, without requiring active effort from the patient
2Type: Electrically operated, motorized CPM system for lower-limb rehabilitation.Type: Electrically operated, motorized CPM system for lower-limb rehabilitation.
3Movement: Continuous passive flexion/extension with controlled, smooth and repeatable movement.Movement: Continuous passive flexion/extension with controlled, smooth and repeatable movement.
4Joint rehabilitation: Knee and hip mobilization; ankle mobilization shall also be available.Joint rehabilitation: Knee and hip mobilization; ankle mobilization shall also be available.
5Knee range of motion: At least approximately -10° to 120° or wider, with programmable limits.Knee range of motion: At least approximately -10° to 120° or wider, with programmable limits.
6Hip range of motion: At least approximately -7° to 115° or wider, with programmable limits.Hip range of motion: At least approximately -7° to 115° or wider, with programmable limits.
7Ankle range of motion: At least approximately 20° to 0° to 40° or equivalent clinically suitable range.Ankle range of motion: At least approximately 20° to 0° to 40° or equivalent clinically suitable range.
8Speed control: Programmable speed control, preferably adjustable over a range of approximately 0°–120°/min or better.Speed control: Programmable speed control, preferably adjustable over a range of approximately 0°–120°/min or better.
9Flexion/extension control: Independent programmable control of flexion and extension limits.Flexion/extension control: Independent programmable control of flexion and extension limits.
10Force control: Adjustable force/load control with force reversal or safety response in case of excessive resistance.Force control: Adjustable force/load control with force reversal or safety response in case of excessive resistance.
11Pause function: Adjustable pause at extension and flexion endpoints.Pause function: Adjustable pause at extension and flexion endpoints.
12Progressive movement: Progressive automatic increase of range of motion during treatment, with clinician-set limits.Progressive movement: Progressive automatic increase of range of motion during treatment, with clinician-set limits.
13Warm-up: Warm-up cycles/program shall be available before or at the beginning of treatment.Warm-up: Warm-up cycles/program shall be available before or at the beginning of treatment.
14Working/treatment time: Programmable treatment duration; preferably up to 24 hours or continuous/repetitive operation as clinically required.Working/treatment time: Programmable treatment duration; preferably up to 24 hours or continuous/repetitive operation as clinically required.
15Memory/programs: Memory function for storing multiple treatment programs/settings; minimum 10 programmable memory locations preferred.Memory/programs: Memory function for storing multiple treatment programs/settings; minimum 10 programmable memory locations preferred.
16Repetitions: Programmable repetition limits for flexion and extension.Repetitions: Programmable repetition limits for flexion and extension.
17Patient comfort: Adjustable/supportive leg, calf, thigh and foot supports with suitable straps/padding for secure positioning.Patient comfort: Adjustable/supportive leg, calf, thigh and foot supports with suitable straps/padding for secure positioning.
18Adjustability: Device shall accommodate different patient leg lengths and allow ergonomic adjustment of limb supports.Adjustability: Device shall accommodate different patient leg lengths and allow ergonomic adjustment of limb supports.
19Control interface: User-friendly digital/LED/LCD control interface for setting and displaying treatment parameters.Control interface: User-friendly digital/LED/LCD control interface for setting and displaying treatment parameters.
20Remote control: Handheld/corded patient or operator control shall be provided for essential functions such as start/stop and return/comfort position.Remote control: Handheld/corded patient or operator control shall be provided for essential functions such as start/stop and return/comfort position.
21Safety: Emergency stop/quick stop function and suitable protection against excessive movement/force shall be provided.Safety: Emergency stop/quick stop function and suitable protection against excessive movement/force shall be provided.
22Power supply: Suitable for Indian mains supply, 230 V AC, 50 Hz, or 100–240 V AC, 50/60 Hz.Power supply: Suitable for Indian mains supply, 230 V AC, 50 Hz, or 100–240 V AC, 50/60 Hz.
23Construction: Robust, durable, easy-to-clean construction suitable for hospital/clinical use.Construction: Robust, durable, easy-to-clean construction suitable for hospital/clinical use.
24Maximum patient weight: Minimum 140 kg; higher capacity shall be acceptable.Maximum patient weight: Minimum 140 kg; higher capacity shall be acceptable.
25Accessories: Necessary straps, limb/foot supports, remote/control unit, and all standard accessories required for safe operation shall be supplied.Accessories: Necessary straps, limb/foot supports, remote/control unit, and all standard accessories required for safe operation shall be supplied.
26Electrical safety: Electrical safety compliance as applicable to medical electrical equipment, including IEC 60601-1 or latest applicable edition/standard.Electrical safety: Electrical safety compliance as applicable to medical electrical equipment, including IEC 60601-1 or latest applicable edition/standard.
27Quoted model should comply with CE/US FDA & ISO 13485 approved certificates.Quoted model should comply with CE/US FDA & ISO 13485 approved certificates.

AI Tender Summary

OUR REF NO 57426435
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 30-09-2026
Authority
Authority Name Tata Memorial Centre
Work Description Bids Are invited for Cpm Machine (Lower Limb Continuous Passive Mobiliser) - The System Shall Support Therapeutic Movement Of The Knee And Hip, And Ankle Where Applicable, Without Requiring Active Effort From The Patient , Type: Electrically Operated, Motorized Cpm System For Lower-Limb Rehabilitation. , Movement: Continuous Passive Flexion/Extension With Controlled, Smooth And Repeatable Movement. , Joint Rehabilitation: Knee And Hip Mobilization; Ankle Mobilization Shall Also Be Available. , Knee Range Of Motion: At Least Approximately -10° To 120° Or Wider, With Programmable Limits. , Hip Range Of Motion: At Least Approximately -7° To 115° Or Wider, With Programmable Limits. , Ankle Range Of Motion: At Least Approximately 20° To 0° To 40° Or Equivalent Clinically Suitable Range. , Speed Control: Programmable Speed Control, Preferably Adjustable Over A Range Of Approximately 0°–120°/Min Or Better. , Flexion/Extension Control: Independent Programmable Control Of Flexion And Extension Limits. , Force Control: Adjustable Force/Load Control With Force Reversal Or Safety Response In Case Of Excessive Resistance. , Pause Function: Adjustable Pause At Extension And Flexion Endpoints. , Progressive Movement: Progressive Automatic Increase Of Range Of Motion During Treatment, With Clinician-Set Limits. , Warm-Up: Warm-Up Cycles/Program Shall Be Available Before Or At The Beginning Of Treatment. , Working/Treatment Time: Programmable Treatment Duration; Preferably Up To 24 Hours Or Continuous/Repetitive Operation As Clinically Required. , Memory/Programs: Memory Function For Storing Multiple Treatment Programs/Settings; Minimum 10 Programmable Memory Locations Preferred. , Repetitions: Programmable Repetition Limits For Flexion And Extension. , Patient Comfort: Adjustable/Supportive Leg, Calf, Thigh And Foot Supports With Suitable Straps/Padding For Secure Positioning. , Adjustability: Device Shall Accommodate Different Patient Leg Lengths And Allow Ergonomic Adjustment Of Limb Supports. , Control Interface: User-Friendly Digital/Led/Lcd Control Interface For Setting And Displaying Treatment Parameters. , Remote Control: Handheld/Corded Patient Or Operator Control Shall Be Provided For Essential Functions Such As Start/Stop And Return/Comfort Position. , Safety: Emergency Stop/Quick Stop Function And Suitable Protection Against Excessive Movement/Force Shall Be Provided. , Power Supply: Suitable For Indian Mains Supply, 230 V Ac, 50 Hz, Or 100–240 V Ac, 50/60 Hz. , Construction: Robust, Durable, Easy-To-Clean Construction Suitable For Hospital/Clinical Use. , Maximum Patient Weight: Minimum 140 Kg; Higher Capacity Shall Be Acceptable. , Accessories: Necessary Straps, Limb/Foot Supports, Remote/Control Unit, And All Standard Accessories Required For Safe Operation Shall Be Supplied. , Electrical Safety: Electrical Safety Compliance As Applicable To Medical Electrical Equipment, Including Iec 60601-1 Or Latest Applicable Edition/Standard. , Quoted Model Should Comply With Ce/Us Fda & Iso 13485 Approved Certificates.
Basic Detail
Tender No GEM/2026/B/8015522
Bidding Type Tender
Location
City Muzaffarpur
State Bihar
Key Dates
Publish Date 09 Sep 2026
Submission Date 30 Sep 2026
Open Date 01 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 35000
Exemption Available
Document List
bc635fb3-dadb-42c9-bb09-13e1195500d2.pdf
cpm_theraphy_technical_specification_-2_2026-09-09-12-48-12_0a58c3648486ea5afdacdb7f0f1bf3e6.xlsx

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
pdf

bc635fb3-dadb-42c9-bb09-13e1195500d2.pdf

xlsx

cpm_theraphy_technical_specification_-2_2026-09-09-12-48-12_0a58c3648486ea5afdacdb7f0f1bf3e6.xlsx

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders