Housing Urban and Rular Development Government Departments Closing in 21 days TDR #57424559

Tender For 1.Construction Of 2500 Mts Of Grain Storage At Mirhama,Kulgam.(Supply, Installation, Testing & Commissioning Of Fire Fighting With Fire Alarm System For 2500 Mts Grain Storage At Mirhama, Kulgam.)Advertised Cost=₹ 49.21 Lacs (Amount Withou

Issued by Government Departments · Kulgam, Jammu and Kashmir
Tender Value
49.21 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
21 days left
EMD
98420
Bank guarantee accepted
Document Fee
1100
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kulgam → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for 1.Construction Of 2500 Mts Of Grain Storage At Mirhama,Kulgam.(Supply, Installation, Testing & Commissioning Of Fire Fighting With Fire Alarm System For 2500 Mts Grain Storage At Mirhama, Kulgam.)Advertised Cost=₹ 49.21 Lacs (Amount Without Gst=₹ 41.70 Lacs, Gst Amount=₹ 07.51 Lacs)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 10-Sep-2026 Corrigendum Other 01-Oct-2026
2 10-Sep-2026 Addendum Other 01-Oct-2026

BOQ

Name of Work:- 1.Construction of 2500 MTs of Grain storage at Mirhama,Kulgam.(Supply, Installation, Testing & commissioning of Fire Fighting with Fire Alarm System for 2500 MTs Grain Storage at Mirhama, Kulgam.)Advertised cost=₹ 49.21 lacs (Amount without GST=₹ 41.70 lacs, GST Amount=₹ 07.51 lacs)
Sl. No. Item Description
1Fire Protection worksProviding, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Diameter 25 mm pipe
2Diameter 32 mm pipe
3Diameter 40 mm pipe
4Diameter 50 mm pipe
5Diameter 65 mm pipe
6Diameter 80 mm pipe
7Diameter 100 mm pipe
8Diameter 150 mm pipe
9200 mm. dia (wall thickness= 6.3 mm)
10Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221 of following sizes complete as required.Diameter 150 mm pipe
11Providing and fitting of Rock wool insulation of thickness 50 mm for external piping and internal (exposed) held by chicken mesh along with aluminium cladding of 24 Gauge Min density 48 kg/cubic metre.
12Providing and laying cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate of nominal size 20 mm in thrust blocks at bends, tees etc and also as support to vertical pipes (wherever required) centering and shuttering etc complete in all respects.
13FIRE PUMPS & RELATED EQUIPMENT / ACCESSORIESSTANDBY DIESEL ENGINE PUMP(a) Supplying, installation, testing and commissioning of diesel engine driven main fire pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)(b) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as perstandard specification, stop solenoid for auto stop in the event offault with audio indications, painted with post office red colour etc. as required.(d) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plastered and with ant vibration pads.2280 lpm at 88 m Head
14FUEL TANK: Daily service fuel tank of suitable 200 liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.
15JOCKEY PUMP(a) Supplying, installation, testing and commissioning of electric driven pressurisation pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Jockey Pump) (b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required. (c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018.(d) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plastered with anti-vibration pads.180 lpm at 88 m Head
16MAIN HYDRANT / SPRINKLER PUMP(a) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in allrespects, as required :(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018.(d) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e)Suitable cement concrete foundation duly plastered with anti vibration pads.2280 lpm at 88 m Head
17Terrace Booster Pump(a) Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018.(d) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(e) Suitable cement concrete foundation duly plastered and with anti-vibration pads.450 lpm at 35 m Head
18Recirculation pumpSupplying, installation, testing and commissioning of electric driven centrifugal type circulation pump for fire fighting water tank recirculation system having discharge 634 LPM at 4 m head complete with 1.5 HP TEFC squirrel cage induction motor suitable for 415 V, 3 phase, 50 Hz supply, MS base frame, flexible coupling with guard, foundation bolts, alignment, testing and commissioning etc. complete as required.
19Control Pnel Fabrication, supplying, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internalwiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :Incomings400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500AOutgoings(Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Diesel Engine ControlControl for diesel engine comprising – Automatic/Manual selctor switch & 3 attempt starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine.Terrace Pump32 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.
20Providing, laying, testing and commissioning of 1.1 kV grade, 4 core × 120 sq.mm Aluminium conductor, XLPE insulated, PVC sheathed, armoured cable, conforming to IS:7098 (Part-I), laid on cable tray / clamped to wall surface, including supply and fixing of suitable size heavy duty double compression cable glands, aluminium lugs, ferruling, dressing, clamping, and all necessary accessories complete as required.From Sub-Station to Control Panel
21Providing, laying, testing and commissioning of XLPE insulated, PVC sheathed, armoured copper conductor power cable from fire pump control panel to respective pump motors, complete with glands, lugs, termination, dressing and connections as required.(i) Main Electric Fire Pump (75 HP):4 Core x 70 sq.mm Aluminium XLPE Armoured Cable
22(ii) Jockey Pump (7–10 HP):4 Core x 10 sq.mm Aluminium XLPE Armoured Cable
23(iii) Terrace pump (1.5-3 HP):4 Core x 6 sq.mm Copper XLPE Armoured Cable.
24Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
25Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 Each of G.I. nut bolt & spring washer spaced at 50mm)
26Supplying and installation following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.100 mm width X 50 mm depth X 1.6 mm thicknessFor 10 Sq.mm
27200 mm width X 50 mm depth X 1.6 mm thicknessFor 70 Sq.mm
28300 mm width X 50 mm depth X 1.6 mm thicknessFor 120 Sq.mm
29Providing and fixing Resilient rubber neoprene lined single arch vibration eliminators suitable for raw water upto 450C temperature working pressure 7 kg/cm2 and test pressure 16.0 kg/cm2 with unit control including nuts, bolts matching flanges (screwed or welded) complete with 1.5mm thick compressed asbestos gasket of same rating.150/125 mm dia (or as per nominal bore of outlet & inlet of 2250 LPM Fire Pumps)
3080 mm dia (or as per nominal bore of outlet & inlet of Jockey Pump 180 lpm)
31Nominal bore suitable for trerrace pump (450 lpm)
32Inverter/UPS with batteryOnline UPS - Input supply: Single Phase, Output Supply: Single Phase. Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 °C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc3KVA
33Supply, installation, testing and commissioning of 15 W LED Internal Emergency Light fitting for Pump Room, suitable for operation on UPS-backed emergency power supply, complete with all mounting accessories, wiring connections and associated components, complete as required.Internal Emergency Lighting (Pump Room)
34Supply, installation, testing and commissioning of 25 W LED Weatherproof External Emergency Light fitting, suitable for operation on UPS-backed emergency power supply, complete with all mounting accessories, wiring connections and associated components, complete as required.External Emergency Lighting
35Providing and laying FRLSH copper conductor wiring of suitable size in PVC/GI conduit, including all accessories, terminations, junction boxes, saddles, clamps and connections required for complete installation of the emergency lighting system from the UPS-backed power supply.Internal Emergency Lights: 2 × 1.5 sq.mm + 1 × 1.5 sq.mm Cu FRLSH
36External Emergency Lights: 2 × 2.5 sq.mm + 1 × 2.5 sq.mm Cu FRLSH
37Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded
38Supplying, fixing of double flanged Accentric reducer of rating PN 1.6, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 150 mm dia
39Providing, supplying, installing, testing and commissioning approved make Cast Iron / Ductile Iron Foot Valve conforming to IS: 4038, complete with stainless steel strainer, gunmetal/bronze seating, nuts, bolts, rubber gaskets and all accessories, fitted at the suction end of pump suction pipe inside underground fire water tank, including fixing, testing and commissioning complete as required.Dia 200 mm
40Gate ValveSupplying, fixing, testing & commissioning of double flanged Gate valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat,ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :150mm dia (On Main Suction & Dischage Header)
4180mm dia (On Main Suction & Dischage Header)
42Y-STRAINERProviding, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150 mm Dia (On Suction haeder For Electric pump & Diesel Pump)
4380 mm Dia (On Suction haeder Jockey)
44NON RETURN VALVEProviding, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia( Discharge Header Electric & Diesel Pump)
4580mm dia ( Discharge Header Jockey)
4680mm dia ( Discharge Header Terrace Pump)
47PRESSURE SWITCHSupplying, Installation, Testing and Commissioning of pressure switch in M.S. pipe line including connection etc. as required.(For Each Pump Discharge Line)
48For Terrace pump Discharge Line
49Flow SwitchProviding & fixing flow switch in following sizes M.S. pipe including connection etc. as required.150 mm Dia
5080 mm Dia
51For Terrace pump Discharge Line80 mm Dia
52PRESSURE GAUGESSupplying, fixing of Pressure Guage with control Valve of rating PN 1.6, ISI marked complete and conforming to IS 780 of following sizes as required.
53AIR VESSELSupplying and fixing air vessel made of 250 mm Dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm Dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.For I) main common discharge header Pump Room& II) For terrace pump discharge
54Supply, install, test and commission UL/FM approved Pressure Relief Valve (PRV) complete with inlet and outlet piping connections, isolation valve, discharge piping to drain, supports, fittings and all accessories, installed on the fire pump discharge header for protection against excessive pressure, in accordance with NFPA 20, approved shop drawings and project specifications.
55Providing and fixing of Electromagnetic Type Flow Meter, 150 mm dia, SS-304 construction, suitable for pressure withstand capacity of 25 kg/cm², complete with flanged end connections, to be installed on the test run pipe, including all accessories, fittings, mounting hardware, testing and commissioning as required.
56INSTALLATION CONTROL VALVEProviding, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of requiredsize, flanges, orifice plate, gasket etc of follwing sizes as required:150mm dia
57Mechanical sprinkler alarm check valve Supply, Install, test and commission mechanical sprinkler alarm check valve assembly including alarm check valve, gong, drain and test valves, retard chamber, pressure gauges at inlet/outlet, alarm stop valve, pressure switch, isolating OS&Y valves and interconnection with fire alarm control panel complete as per drawings & specifications.150 mm diameter Alarm check valve
58“Providing and fixing multi-level float type level switch for fire water tank including floats, control cable, mounting arrangement and connection to control panel complete.”
59Supply, installation, testing and commissioning of drain valve of approved make, complete with fittings, nipples, unions and accessories, for draining and flushing of fire fighting pipeline system, including connection to drain line, complete as required.25 mm
60Providing and fixing 150 mm dia butterfly valve conforming to relevant standards for use as main drain valve in fire fighting system, complete with flanged connections, nuts, bolts, gaskets, testing and commissioning as required.150 mm
61INTERNAL & EXTERNAL HYDRANT SYSTEMSupplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required:2 way-100 mm dia M.S. Pipe
62Supply, installation, testing & commissioning of Gun Metal Fire brigade suction hose coupling 2 Way (Draw-out Connection) with nut for female coupling as per IS:902-1974 complete with 100 mm dia. GI suction pipe and 100/150 mm dia. 1 No. CI foot valve flanged (to be connected to static water tank).
63Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel
64Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :150mm dia ( For External & internal )
65Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required:Single headed Stainless steel
66Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.(a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585(b) 20 mm nominal internal dia gun metal globe valve & nozzle.(c) Drum and brackets for fixing the equipmets on wall.(d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m
67Providing, fixing testing and commissioning of Weather proof standard fire hose cabinet (750 mm x 600 mm x 250 mm deep) for yard hydrants made of 16 SWG powder coated M.S. sheet having single or double opening glazed (4.0 mm thick glass) shutter including necessary locking arrangement by allan key, stove enamelled Fire red finish (as per IS : 5, shade no. 536) with \\" Fire Hose\\" marked on front, suitable for housing 2 nos. Hose pipe, 1 No. branch pipe & nozzle spanner. (Location : For External Hydrant)
68Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required: 2 RRL hoses per hydrant cabinetStainless Steel (Grade 304)
69Supplying & fixing 63 mm Dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required:Stainless Steel (Grade 304)
70Installation of standard fire Hose Cabinet (7 00 x 600x 250 mm) Indoor Type suitable for accomodating internal hydrant, hose reel made of not less than 16 SWG MS sheet having full fronted glass hinged door (5 mm thick glass) including necessary locking arrangement with handle for housing two nos. 15 meter long fire hose pipes, 30 meter long hose reel, branch pipe and hydrant valve as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coat of fire red colour). The cabinet shall be mounted on suitable raised platform. The words \\"FIRE HOSE\\" to be painted on the box.Location :( internal Fire Hose Cabinet ( FHC)
71Installation & fixing of standard carbon steel Fireman Axe with rubber insulated handle tested up to 20,000 Volts, complete with wall mounting arrangement inside fire hydrant cabinet, as required.
72Supplying and fixing orifice plate (Pressure Reducing Valve) made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 - 7 kg/cm2 complete as required.
73Providing, fixing and commissioning of spring loaded air release valve: 25mm diasuitable for pressure of 15Kg/sq.cm including flanges, nuts, bolts, washers etc.complete as required. (For Vertical Riser Line,External Hydrant Ring & Terrace Level Ring)
74Fire SprinklersProviding, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 °C with required accessories : Upright SprinklerUpright Sprinkler
75Fire Extinguisher IS : 13849 & Other AccessoriesProviding and fixing ABC stored pressure dry chemical powder (monoammonium phosphate) Fire Extinguisher IS : 13849 latest revision manufacturer and of CRCA sheet in welded construction, finish with epoxy polyster powder coated complete with brass forged ball valve, gun metal cap and nozzel, including initial filled and wall suspension bracket (suitable for fighting in class 'A', B & 'C' that is wood, textile, flammable liquid, electric and gases.Capacity 4kg
76Providing and fixing ISI marked (IS:15683:2018 CO2 type fire extinguisher o f 4.5Kgs. Capacity, with initial filling in brand new PESE approved cylinder with powder coated finish, fitted with Castor wheel trolley. EPDM discharge hose, wall mounting bracket, used unused incator and Fire rating Class B:55B complete, confirming to IS
77Supply, installation, testing and commissioning of 9-litre capacity Water Type Portable Fire Extinguisher, stored pressure type, conforming to IS 15683, suitable for Class-A fires, complete with MS cylinder with internal anti-corrosive coating, squeeze grip control valve, discharge hose, nozzle, pressure gauge, safety pin, wall mounting bracket, and refilling arrangement, including painting, marking, installation at required locations, and testing as per NBC and relevant IS standards, complete in all respects.
78\\"Providing and fixing Fire Exit Sign Board of size min 300 mm × 150 mm, manufactured from 3 mm thick rigid PVC sheet, having photoluminescent/reflective white legend 'FIRE EXIT' with directional arrow on green background, complete with all fixing arrangements and accessories as directed by the Engineer-in-Charge.\\"
79Providing and fixing of Fire bucket stands for Buckets With Canopy at designated locations.MOC; MS
80Providing and fixing of Fire buckets with clean sand of 9 Litre capacity to the stands..MOC ; Al
81Intelligent Fire Alarm SystemSupplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.COST FOR 1 POINT
82Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.COST FOR 1 POINT
83Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events historylog in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.Two Loop Panel.
84Supplying, installation, testing & commissioning of addressable manual call point complete as required.Details of cost for one each
85Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required.Details of cost for one each
86Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, Two core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
87Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
88Civil WorksEarth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil
89Providing and laying of stone soling including ramming, consolidating & levelling all complete.
90Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.Sand Bedding Below & Above Pipes
91Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
92Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)In concrete chamber
93CARRIAGE OF MATERIALSBy Mechanical Transport including loading, unloading and stacking Soling stone
94Sand, stone aggregate below 40 mm nominal size
95Cement, stone blocks, G.I. C.I., A.C., Stainless Steel & C.C. pipes below 100 mm dia and other heavy materials Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57424559
AUTHORITY Government Departments
TENDER VALUE 49.21 Lakhs
LAST DATE 01-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for 1.Construction Of 2500 Mts Of Grain Storage At Mirhama,Kulgam.(Supply, Installation, Testing & Commissioning Of Fire Fighting With Fire Alarm System For 2500 Mts Grain Storage At Mirhama, Kulgam.)Advertised Cost=₹ 49.21 Lacs (Amount Without Gst=₹ 41.70 Lacs, Gst Amount=₹ 07.51 Lacs)
Basic Detail
Tender No e-NIT No 15 of RandB/MDSK /2026-27 Dated 09-09-2026
Bidding Type Tender
Location
City Kulgam
State Jammu and Kashmir
Key Dates
Publish Date 10 Sep 2026
Submission Date 01 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value 49.21 Lakhs
Tender Fee 1100
EMD 98420
Exemption Not Available
Document List
a8166094-d771-4fa6-a7d1-87ffe28fcc31.html
BOQ_1092430.xls
Tendernotice_1 (19).pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Oct 01, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 21 days
Oct 01, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 21 days
Oct 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

a8166094-d771-4fa6-a7d1-87ffe28fcc31.html

xls

BOQ_1092430.xls

pdf

Tendernotice_1 (19).pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders