Public Administrative Department Local Bodies Closing in 7 days TDR #57422117

Tender For Provision Of Cable And Panel For Etp/Stp Plant At Kasturba Hospital.

Issued by Local Bodies · Delhi, Delhi
Tender Value
5.89 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
7 days left
EMD
12372
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of Cable And Panel For Etp/Stp Plant At Kasturba Hospital.

BOQ

Name of Work:- Provision of cable and panel for ETP/STP Plant at Kasturba Hospital.
Sl. No. Item Description
1Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
2Above 95 sq. mm and upto 185 sq. mm
3Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
4Upto 35 sq.mm.(Clamped with 1 mm thick saddle)
5Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
6Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
7Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
8Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.
9150 mm width X 50 mm depth X 1.6 mm thickness
10Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
11Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
12Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
13Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
143½ X 150 sq. mm (50mm)
15Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
16200 A,16KA,TPMCCB
17400 A,50KA,FPMCCB
18LED Flood Lifgt,powder coated pressure die cast aluminium (System lumen efficacy=105<120 lm/Watt.S/I/T/C of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.=0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumens efficacy≥105<120 lm/watt.LM79 & LM80 Test Report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management heat sink of aluminium housing such that LED junction temperature shall not rise above 90 degree C.
19150 Watt
20Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*150 sqmm
21Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2 C*10 Sq.mm
22Supplying, Installation, testing and commissioning of earth pit of minimum dia. 100 mm size 3 mtr. Deep in hard rock soil, through machine or by any suitable means. Earth electrode consisting of 3 mtr. Long and 50 mm Dia. Size G.I electrode surrounded by highly conductive black fill compound chemical 2 bags (25 kg each) with necessary masonry encloser for 300 mm x 300 mm size GI earth pit cover complete as required.
23S/I/T/C of MCCB Sheet Metal Enclosure, 4P, 100-125A
24P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57422117
AUTHORITY Local Bodies
TENDER VALUE 5.89 Lakhs
LAST DATE 21-09-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Provision Of Cable And Panel For Etp/Stp Plant At Kasturba Hospital.
Basic Detail
Tender No 32/MWEEE-I/2026-27/TC
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 09 Sep 2026
Submission Date 21 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value 5.89 Lakhs
Tender Fee 590
EMD 12372
Exemption Not Available
Document List
5fa792c0-604d-4ea4-ad99-1a62ac55e34c.html
BOQ_338575.xls
DNIT03.pdf
Tendernotice_1 (10).pdf
Tendernotice_2 (2).pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

5fa792c0-604d-4ea4-ad99-1a62ac55e34c.html

xls

BOQ_338575.xls

pdf

DNIT03.pdf

pdf

Tendernotice_1 (10).pdf

pdf

Tendernotice_2 (2).pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders