Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #57422096

Tender For Repair / Replacement Of Security Lights Of Entire Khumbathang Garrisson In The Aor Of Age E/M Under Ge Khumbathang.

Issued by Statutory Bodies & Commissions/Committees · Kargil, Jammu And Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
22 Sep 2026
8 days left
EMD
76000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kargil → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair / Replacement Of Security Lights Of Entire Khumbathang Garrisson In The Aor Of Age E/M Under Ge Khumbathang.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 10-Sep-2026 Revised BOQ BOQ 22-Sep-2026

BOQ

Name of Work:- REPAIR / REPLACEMENT OF SECURITY LIGHTS OF ENTIRE KHUMBATHANG GARRISSON IN THE AOR OF AGE E/M UNDER GE KHUMBATHANG.
Sl. No. Item Description
1S&F in repair for Driver for 60/70 Watts LED street light, High mast light and tower light complete all as specified and directed by Engr in charge.
2S&F in repair for Driver for 40/45 Watts LED street light, High mast light and tower light complete all as specified and directed by Engr in charge.
3S&F in repair for Driver for 25/30 Watts LED street light, High mast light and tower light complete all as specified and directed by Engr in charge.
4Excavation in trenches not exceeding 1.5m in depth deep for laying of pipe, cable, foundation of electric pole etc and getting out in hard soil, complete all as specified and directed by Engr-in-Charge.
5Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed by Engr-in-Charge. (Surplus soil if any shall not be removed but left over the trench)
6Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
7Supplying and laying in replacement of double walled corrugated HDPE Pipes of size 40 mm dia as per IS 16205 Anti termite, Anti Rodency and Non flame propagation propety etc for protection of cables complete all as specified and directed
8S&F in repair Junction box made out of FRP sheet of size 300x200x115mm , ready made type having aluminium bus bar of capacity 100 Amps 4 Nos with necessary connector , MCB 6 Amps and entry of gland and fixing arrangement to fix the box on plinth/wall by providing MS clamp and nut bolt . Complete all as specified and directed by Engineer-in-Charge.
9Supply, fixing, connecting and testing in replacement for integral LED flood light luminaries, 100 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting frame, all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories for fixing the light fitting to walls/ ceiling etc. complete all as specified and directed by Engr-in-Charge.
10Supply, fixing, connecting and testing in replacement for integral LED flood light luminaries, 70 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting frame, all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories for fixing the light fitting to walls/ ceiling etc complete all as specified and directed by Engr-in-Charge.
11Supply, fixing, connecting and testing in replacement for integral LED Street light fitting, 35 watts with pressure die cast aluminium housing IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories for fixing the light fitting to walls/ ceiling etc complete all as specified and directed.
12M&L for steel tubular swaged pole complete with cast iron/MS iron base plate welded to the bottom of pole finial taper plug bolts, nuts, screws etc as specified type 410 SP-31(9.0 Mtr long) including two coats of bituminous paint internally and externally for the portion embedded in concrete and two coats of silver paint over one coat of red oxide primer to external/exposed surfaces including excavation and earth work in any type of soil, PCC (1:4:8 ) type D-2 for foundation, PCC (1:2:4) type B-1 for pedestal and coping etc complete all as specified and directed.
13Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 60 watts with pressure die cast aluminium housing IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable , including all accessories for fixing the light fitting to pole complete all as specified and directed.
14Supply and fixing in repair PVC insulated and PVC sheathed three core Copper conductor of size 1.5 Sqmm for connecting from bus bar box to street light fittings/ OH line to street light fitting complete all as specified and directed by Engr-in-Charge.
15Supply and fixing in replacment GI pipe light grade bracket 40mm dia, 1.5m long bent to shape as required for fixing of street lights on poles/walls including nuts, bolts, washers , Clamps (02 sets) of suitable size complete all as specified and directed by Engr-in-Charge.
16S&F in repairs MCB (SPN) 240 volt C curve 10 KA 32/40 Amps capacity IP 20 complete all as specified and directed incl taking down old one.
17Supply and fixing in replacement of Automatic Street Light Switch for 3-phase Load of 08 KW using Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS) for automatic switching of Street Lights. Nature Switch operation should be based on Natural Light Lux level. Required Illuminance Level for Switching ON is ≤ 30 Lux and for Switching OFF ≥ 10 Lux. The Sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs. The Sensor along with suitable Power Contactors with 3 nos. Contactors, 3 nos. Incoming MCBs & 3 nos. Outgoing MCBs of 20-32 Amps each. Circuit wiring (Copper) of min.10 sq.mm and Auto-Manual selection option (Sensor By-Pass) should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP-66 complete all as specified and directed by Engr-in-Charge. Make : SUDEEP, HANSEL, C&S, SINTEX and L&T
18Supply and laying in replacement XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size 16 Sq mm 4 core complete all as specified and directed by Engr-in-Charge.
19Supply and laying in replacement XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size 10 Sq mm 4 core complete all as specified and directed by Engr-in-Charge.
20Supply and laying in replacement XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of size 16 Sq mm 2 core complete all as specified and directed by Engr-in-Charge.
21M & L for in replacement of GI tubing light grade 40 mm bore for passing through cables under the floor incl cutting the road and making good afterlaying of GI pipe same as previous surface ,complete all as specified and directed by Engr-in-Charge.
22M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0 mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I complete all as specified and directed by Engr-in-Charge.
23Deduct Credit for Demolished/Dismantled material Rs (-) 1,19,240.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule)Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57422096
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 22-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Replacement Of Security Lights Of Entire Khumbathang Garrisson In The Aor Of Age E/M Under Ge Khumbathang.
Basic Detail
Tender No GE/KHU-95/2025-26
Bidding Type Tender
Location
City Kargil
State Jammu And Kashmir
Key Dates
Publish Date 10 Sep 2026
Submission Date 22 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 76000
Exemption Not Available
Document List
BOQ_883851.xls
ea847a26-3207-4eed-b9ed-e9054f1d8abd.html
Tendernotice_1 (10).pdf
TenderRE.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 22, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 8 days
Sep 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_883851.xls

html

ea847a26-3207-4eed-b9ed-e9054f1d8abd.html

pdf

Tendernotice_1 (10).pdf

pdf

TenderRE.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders