Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #57422081

Tender For Provn Of 80 X Geyser (25 Ltrs) In Jcos/Or Md Accn And Transformer Under Ge Babina

Issued by Statutory Bodies & Commissions/Committees · Jhansi, Uttar Pradesh
Tender Value
36.89 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
20 days left
EMD
74000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jhansi → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of 80 X Geyser (25 Ltrs) In Jcos/Or Md Accn And Transformer Under Ge Babina

BOQ

Name of Work:- PROVN OF 80 X GEYSER (25 LTRS) IN JCOS/OR MD ACCN AND TRANSFORMER UNDER GE BABINA
Sl. No. Item Description
1Supplying, installation, connecting, testing and commissioning of outdoor type distribution transformer of 250 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed copper wound step down enrgy efficient (Level 2) as per IS 1180 : 2014 with amended No 1, 2, 3 & 4 floor mounted complete with first filling ISI marked filtered & dehydrated transformer oil and other standard fittings / accessories and 7 position off circuit/load tap changer (tapping range +/- 7.5% in steps of 2.5% each) with vector group DYN -11 complete all as specified and as directed Note - (a) The ambient temprature shall be 48 degree Centigrade when measured by the resistance method after continuous full load run . (b) The transformer shall be complete with standard fittings all as specified and conforming to IS:335 of 1993 for oil and IS: 1180 Part -I of 2014 for transformer and comprising of followings:- (i) One No cable box on LV side (secondary side) consisting of 04 Nos of porcelain bushing with bushing rods and another cable box on HV side (primary side) consisting of 03 Nos of porcelain bushing with bushing rods etc complete with nut, washers, cable gland etc.(ii) Oil conservator tank with filter type drain valve and oil level gauge.(iii) Oil level indicator with minimum and maximum marking(iv) Dehydration silica gel breather assembly with first fill of dehydrating agent and oil seal.(v) Explosion vent with diaphragm complete.(vi) Thermometer pocket on tank cover.(vii) Dial type thermometer vapour pressure having range 0-120 degree C with max reading pointer max temp indicator and resetting device.(viii) Rating plate with terminal marking.
2(ix) 02 Nos earthing terminal on tank and cover for fixing earth strip of size 32 x 6 mm.(x) Oil level gauge and top valve for oil filtration and drain cum sampling valve.(xi) Lifting hook.(xii) Oil filler hole with cap /plug with connection complete.(xiii) Air relief valve plug.(xiv) Detachable rollers - 04 Nos(xv) Extra bushing for Neutral out side the cable box for independent earthing for neutral earth.(xvi) First fill of fresh transformer oil confirming to relevant IS and tested up to 40 KV die electric strength. (xvii) Suitable PCC foundation for mounting of tranformer.
3Supplying, laying, jointing & commissioning in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, (Earthed) cross sectional area 95 sqmm 3 core as per IS 7098 Pt-II complete all as specified and directed.
4Supply and laying or fixing or passing through HDPE pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 35 sq mm 4 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
5Supply and laying or fixing or passing through HDPE pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 50 sq mm 4 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
6Supply and laying or fixing or passing through HDPE pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 120 sq mm 4 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
7Supply and laying or fixing or passing through HDPE pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 150 sq mm 4 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
8Supply and laying or fixing or passing through HDPE pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 185 sq mm 4 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
9Supply and laying or fixing or passing through HDPE pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 240 sq mm 4 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
10Supply and laying or fixing or passing through HDPE pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 300 sq mm 4 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
11Excavation in trenches in any type of soil not exe 1.5 mtrs wide and not exe 1.5 mtr in depth for laying of pipe/cables etc and getting out incl forming bottom surface to the required level/slope etc complete all as specified and directed .
12Returning fitting in soft/loose soil, including spreading levelling watering and well ramming in layers n.exc 25 cm complete all as directed
13Removing excavated material / surplus soil to a distance not exc. 50 mtrs & deposited where directed at a level not exc.1.5 mtr above the ground level complete all as specified & directed.
14Supply laying dry clean sand free from sharp materials, unscreened filling in trenches around under ground cables for cushioning complete all as specified and directed.
15M&L for PCC cable cover class HV type 1 flat size 300 mm x 180 mm x 40 mm, ISI marked across the cable for protection of cable after sand cushioning complete all as specified & directed.
16Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm to 150mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge.
17S&F of cable jointing Kit 11 KV (earthed) grade cable for indoor type end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm complete all as specified and directed.
18S&F of cable jointing Kit 11 KV (earthed) grade cable for outdoor type end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm complete all as specified and directed.
19Supply, installation, testing and commissioning of lightening arrester polymer type SMX type complete with all fittings transmission class, discharge capacity 65 Kilo Amp suitable for system voltage 11 KV complete all as specified and directed.
20M&L for switch air break gang operated triple pole polymer type, mechanically operated mounted on HT insulators (12 insulator type) and MS steel frame with operating mechanism worked from ground level with 11 KV insulation for current rating up to 200 amps 11000 volts with locking arrangement, MS clamps, nuts, bolts and washers etc also incl drop out expulsion type fuse, single pole up to 25 Amps, 11000 volts fuse barrels, incl two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified and directed.
21S & F and replacement of cross arms, bracing, supports clamps and back plates fabricated from structural steel sections incl nuts & bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size and inclusive of one red oxide primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed
22M&L for earthing complete with galvanised steel earth plate electrode of size 600X600X6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below the ground level connected to galvanised iron strip of 32 x 6 mm as earth lead by means of bolts nuts check nuts & washers of galvanised iron or steel ,surrounded by charcoal of coke and salt, water pipe 20mm bore GI medium grade with funnel and wire mesh,and making chamber of PCC (1:4:8) type D-2 using 40 mm graded stone aggregate and coping shall be in PCC(1:3:6) type C-1 using 20 mm graded stone aggregate, 50 mm thick cover of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate, reinforced with 8 mm dia TMT bars @ 80 mm c/c boath ways including excavation and earth work and removal of surplus soil to distance n exc 50 m complete all shown in electrical plate No 3 of SSR part- 2010 complete all as specified and directed. Note :-(i) The cost of GI earth lead & G I pipe of 7.50 mtr length for protection of GI wire and excavation work for pit shall deemed to be included in this item. (ii) Earthing test will be carried out and if desired result not achieved and the earthing will be redone to achieve desired result without any extra payment. (iii) Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate.
23Supply , commissioning and testing factory made LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 50x50x5mm thick angle iron base frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following complete all as specified and directed. (a) Aluminium bus bar four strips 600 Amps ,415 volts,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set. Incoming:- (b) MCCB, 04 Pole, 500 Amps with ultimate breaking capacity Icu- 36 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) Outgoing:- (c ) MCCB, 04 Pole, 200 Amps with ultimate breaking capacity Icu- 36 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 03 Nos (Ics=Icu=100%)(Make :- Havells/L&T/schnider/ABB) (d) MCCB, 04 Pole, 125 Amps with ultimate breaking capacity Icu- 36 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 Nos (Ics=Icu=100%).(e) Spare way for MCCB 125 Amp 4 way - 01 Nos (g) Analoge type volt meter 0-500 volt - 1Set. (h) Indication lamps R,Y,B LED type with 3 Nos – 1 set:-
24(f) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's. Note :- Panel drawings & make of MCCB/SDFU will be submitted by contractor for approval from Accepting Officer before ordering the panel.
25S&F in replacement testing , commissioning of outdoor type bus bar panel padestal type weather proof CPRI aprooved MS cubical panel board made of 3 mm CRCA MS sheet outdoor type of size 100 cm x 80 cm x 40 cm, 4 Nos of aluminium bus bar of 300 Amp capacity with MCCB 4 pole of Capacity 200 Amp 25 KA (Ics =Icu=100%) including one coat of redoxide and two coat of enamel paint powder coated, mounted on mild steel channel of suitable size and PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels including stand, aluminium bus bar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. LT Panel board should be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011, Type Test certificates for Short Circuit Test, Temperature Rise Test, Di-Electric Property Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 65KA. ( The contractor should submit all Certificates before executing the job.)
26M & L for pvc surface conduit point wiring complete with PVC insulated and unsheathed flame retardant low smoke low smoke and halogen ( FRLSH ) cable of 2.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia, clip, with MS terminal boxes (not less than 1.0 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dolly with 3 mm thick plastic laminated sheet top cover of approved make and colour including 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed . Please Enable Macros to View BoQ information
27M & L for pvc surface conduit point wiring complete with PVC insulated and unsheathed flame retardant low smoke low smoke and halogen ( FRLSH ) cable of 2.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia, clip, with MS terminal boxes (not less than 1.0 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dolly with 3 mm thick plastic laminated sheet top cover of approved make and colour including 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57422081
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 36.89 Lakhs
LAST DATE 03-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of 80 X Geyser (25 Ltrs) In Jcos/Or Md Accn And Transformer Under Ge Babina
Basic Detail
Tender No CWE/JHA/BAB/TOKEN/76 OF 2026-27
Bidding Type Tender
Location
City Jhansi
State Uttar Pradesh
Key Dates
Publish Date 09 Sep 2026
Submission Date 03 Oct 2026
Open Date 06 Oct 2026
Finance
Tender Value 36.89 Lakhs
Tender Fee 500
EMD 74000
Exemption Available
Document List
a7122063-aa63-4d3d-a4d7-9c3ee458e169.html
BOQ_883823.xls
Tenderdocuments76.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Oct 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

a7122063-aa63-4d3d-a4d7-9c3ee458e169.html

xls

BOQ_883823.xls

pdf

Tenderdocuments76.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders