Tender For Repair And Maintenenace Of Transformers And Ht/Lt Panels Of 11 Kv Substation Under Stc Bsf Kashmir.

Issued by Government Departments · Budgam, Jammu and Kashmir
Tender Value
7.75 Lakhs
Estimated cost
Bid Submission
17 Sep 2026
3 days left
EMD
15506
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Budgam → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenenace Of Transformers And Ht/Lt Panels Of 11 Kv Substation Under Stc Bsf Kashmir.

BOQ

Name of Work:- Repair and maintenenace of transformers and HT/LT Panels of 11 KV substation under STC BSF Kashmir.
Sl. No. Item Description
1Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. 100 A,30KA,FPMCCB
2250 A,36KA,FPMCCB
3400 A,50KA,FPMCCB
4200 A,36KA,FPMCCB
5Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 185 sq. mm (57mm)
6Providing and applying two or more coats of synthetic enamel paint of approved brand and manufacturer and of required shade on metal surfaces of electrical equipment (panels,Bus duct, Transformer etc.). The work includes the preparation of the surface by thoroughly cleaning oil, grease, dirt, and removing rust or scale using wire brushing or emery paper, complete as per standard specifications and the direction of the Engineer-in-Charge.\\"
7Dehydration of transformer oil in the existing transformer at site , moisture removal from transformer oil,and maintain the viscosity of oil. Necessary pump and barrel driving execution of work shall be part of contractor if oil drain out necessary. Transformer oil dehydration is based on use of synthetic adsorbents ,additionally allows moisture to diffuse out of the paper into the oil. and submit the test report of transformers after conducting of its dielectric strength, viscosity, thermal conductivity, chemical stability ,BDV value etc as required.
8Supplying and fixing joint box of size 450 X 450 X 250 MM having 250 Amps rating, 4 strips, long aluminum busbars mounted on suitable no of porcelain/SMC insulators, complete with all accessories making connections as required
9Supplying and replacement of complete Silica Gel approved make and required capacity for oil-filled electrical transformer. indicating-type (orange) silica gel with standered complies with IS: 3401-1992 complete as per standard specifications and direction of the Engineer-in-Charge.\\"
10Comprehensive overhauling, servicing, and routine testing of 11 kV Indoor Vacuum Circuit Breaker (VCB) panel. The scope of work includes racking out the breaker, thorough cleaning using vacuum cleaners and CRC/contact cleaners, checking and lubricating the mechanical operating and tripping mechanism, tightening of all power and control electrical connections, and checking pole discrepancy and replacement of parts to ensure safety and optimal performance. The item includes electrical testing: Measurement of Insulation Resistance (Megger), Contact Resistance Measurement (CRM),Testing tripping and closing mechanisms complete as per standard specifications and the direction of the Engineer-in-Charge.
11​Servicing, overhauling, and testing of LT Air Circuit Breaker (ACB), including isolation racking out, dismantling of arc chutes, cleaning of fixed and moving contacts with approved cleaning agents, lubrication of mechanical linkages and racking mechanisms. The work includes checking and calibration of all protective relays (Overload, Short Circuit, Earth Fault, Under Voltage), measurement of contact resistance and insulation resistance (Megger test), tightening of all control wiring terminations, and final testing of the breaker for smooth closing and tripping operations, complete as per standard specifications and the direction of the Engineer-in-Charge.
12Testing, calibration, and commissioning of protective relays (Numerical / Electromechanical type) installed in 11kV Vacuum Circuit Breaker (VCB) panels. The scope includes secondary injection testing for overcurrent, earth fault, master trip (86), and trip circuit supervision (95) relays to verify pickup values and IDMT timing characteristics using a calibrated computerized test kit. The work includes checking trip logic, control wiring continuity, and submission of comprehensive test reports in triplicate, complete as per standard specifications and the direction of the Engineer-in-Charge
13Design, manufacture, supply, installation, testing, and commissioning of 2000 X 2000 500 MM indoor type, free-standing, floor-mounted, totally enclosed, compartmentalized, cubicle type Main LT Panel. Fabricated from 2.0 mm thick CRCA sheet, powder-coated to approved shade. The panel shall be dust and vermin proof (IP-52/IP-54), having 600 A high-conductivity 04 nos of Aluminum busbars with color-coded and sleeved,. The work includes all internal wiring, control MCBs, CTs, digital multi-function meters, indication lamps, and accommodating specified incoming and outgoing switchgear (MCCBs), Making connection of outgoing cables. Includes provision of dual earthing terminals, and comprehensive testing (Megger, functional test) prior to commissioning, complete as per specifications and the direction of the Engineer-in-Charge
14Supplying, Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.3.5x185 SQMM
15Supplying and installation Testing comissioning of 630 A compact design on load manual handle change over switch with four pole, 415 volt complete as per standard specifications and direction of the Engineer-in-Charge.\\" Make ( Havells, HPL, L&T, Seimens, Schneider,C&S or equivalent Make) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57422044
AUTHORITY Government Departments
TENDER VALUE 7.75 Lakhs
LAST DATE 17-09-2026
Authority
Authority Name Border Security Force
Work Description Tender for Repair And Maintenenace Of Transformers And Ht/Lt Panels Of 11 Kv Substation Under Stc Bsf Kashmir.
Basic Detail
Tender No 05/DC(E)/STC/KMR/2026-27
Bidding Type Tender
Location
City Budgam
State Jammu and Kashmir
Key Dates
Publish Date 09 Sep 2026
Submission Date 17 Sep 2026
Open Date 18 Sep 2026
Finance
Tender Value 7.75 Lakhs
Tender Fee Ref. Documents
EMD 15506
Exemption Available
Document List
73e39aaa-8196-49d4-ae5a-5ea7fb7b5ac0.html
BOQ_972523.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Sep 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

73e39aaa-8196-49d4-ae5a-5ea7fb7b5ac0.html

xls

BOQ_972523.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders