Water Resources and Irrigation Local Bodies Closing in 4 days TDR #57421153

Tender For O&M - Water Supply Schemes-Electrical Maintenance-Twss - Urgent Maintenance Of Electrical Wiring And Lighting Equipment At Filter House -General Civil Work

Issued by Local Bodies · Thiruvananthapuram, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
15 Sep 2026
4 days left
EMD
8981
Bank guarantee accepted
Document Fee
795
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for O&M - Water Supply Schemes-Electrical Maintenance-Twss - Urgent Maintenance Of Electrical Wiring And Lighting Equipment At Filter House -General Civil Work

BOQ

Name of Work:- O&M - Water Supply Schemes-Electrical maintenance-TWSS - Urgent Maintenance of Electrical wiring and Lighting equipment at Filter House -General Civil Work
Sl. No. Item Description
1Bed 1 to 7,compressor area, lab, flow alert area,operators room
2OD344519/2025-2026:Supply and installation of sheet steel, phosphatised and painted, dustand vermin proof enclosure of MCB DB including copper /brass busbar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed inrecess including cutting hole on the wall , making good the damages,colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
3OD344518/2025-2026:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA \\"C\\" curve,miniature circuit breaker suitable for inductive load of following poles inthe existing MCB DB complete with connections, testing andcommissioning etc. as required.TPN MCB
4OD344517/2025-2026:Supplying and fixing following rating, double pole, (single phase andneutral), 240 volts, residual current circuit breaker (RCCB), having asensitivity current upto 300 milliamperes in the existing MCB DBcomplete with connections, testing and commissioning etc. as required.25 amps,30mA
5OD337711/2025-2026:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve,miniature circuit breaker suitable for inductive load of following poles inthe existing MCB DB complete with connections, testing andcommissioning etc. as required.Single pole
6OD344516/2025-2026:Supply, laying and clamping of 1 no. PVC insulated and PVCsheathed armoured aluminium power cable, 1.1 KV grade of thefollowing sizes using clamps noted along with the cables, spacing ofclamps not exceeding 60cms, making good the damages , colourwashing etc. as required.4 core 10 sq mm with factory made clamp
7OD337709/2025-2026:Supply and drawing 650/1100 V grade FRLS PVC insulatedstranded single core copper conductor cables conforming to IS 694part I 1990 in the existing surface / recess conduit as requiredincluding giving necessary connections of the following sizes.1.00 sq.mm 3 Run( for light & fan points)
8OD337708/2025-2026:Supplying and drawing following sizes of FRLS PVC insulated copperconductor, single core cable in the existing surface / recessed steel/ PVCconduit as required.3 X 1.5 sq.mm( DB to Lighting switch board & 6A sockets)
9OD337707/2025-2026:Supplying and drawing following sizes of FRLS PVC insulated copperconductor, single core cable in the existing surface / recessed steel/ PVCconduit as required.3 x 2.5 sq. mm( DB to 6/16A sockets, flood lights,HD exhaust fans)
10OD337706/2025-2026:Supplying and fixing of following sizes of medium class PVC conduit alongwith accessories in surface/ recess including cutting the wall and makinggood the same in case of recessed conduit as required.20 mm
11OD337704/2025-2026:Supplying and fixing following Modular base & cover plate on existingmodular metal boxes etc. as required.12 Module
12OD337703/2025-2026:Supply & Fixing the following types/ sizes of boxes suitable formodular accessories in surface/ recess including making good thedamages, colour washing etc as required (RoHS compliant )9 module moulded plastic box on surface
13OD337702/2025-2026:Supply & Fixing the following types/ sizes of boxes suitable formodular accessories in surface/ recess including making good thedamages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
14OD337701/2025-2026:Supplying and fixing following Modular base & cover plate on existingmodular metal boxes etc. as required.8 Module/9 module
15OD337700/2025-2026:Supply & Fixing the following types/ sizes of boxes suitable formodular accessories in surface/ recess including making good thedamages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
16OD337699/2025-2026:Supplying and fixing following Modular base & cover plate on existingmodular metal boxes etc. as required.6 Module
17OD337698/2025-2026:Supply & Fixing the following types/ sizes of boxes suitable formodular accessories in surface/ recess including making good thedamages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
18OD337697/2025-2026:Supplying and fixing following Modular base & cover plate on existingmodular metal boxes etc. as required.3 Module
19OD337696/2025-2026:Supply & Fixing the following types/ sizes of boxes suitable formodular accessories in surface/ recess including making good thedamages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
20OD337695/2025-2026:Supplying and fixing following Modular base & cover plate on existingmodular metal boxes etc. as required.1 or 2 Module
21OD337694/2025-2026:Supplying and fixing following modular switch/ socket on the existingmodular plate & switch box including connections but excluding modularplate etc. as required.3 pin 5/6 amp socket outlet
22OD337693/2025-2026:Supplying and fixing following modular switch/ socket on the existingmodular plate & switch box including connections but excluding modularplate etc. as required.5/6 amps switch
23OD337692/2025-2026:Supplying and fixing following modular switch/ socket on the existingmodular plate & switch box including connections but excluding modularplate etc. as required.6 pin 15/16 amp socket outlet
24OD337691/2025-2026:Supplying and fixing following modular switch/ socket on the existingmodular plate & switch box including connections but excluding modularplate etc. as required. 15/16 amp switch
25OD337690/2025-2026:Supplying and fixing two module stepped type electronic fan regulator onthe existing modular plate switch box including connections but excludingmodular plate etc. as required
26OD337689/2025-2026:Supplying and fixing modular blanking plate on the existing modular plate& switch box excluding modular plate as required.
27OD337688/2025-2026:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/wooden block including connection etc as required
28OD337687/2025-2026:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required 1200 mm ,1X20W LED Lamp with heat sink and with box type fixture.
29OD337686/2025-2026:Supply, Installation, testing and commissioning of 30W LED High Wattage fitting(Dome Bulb), Cool White (6500K), B22 Base, 230V AC, BIS Certified Make : CROMPTON -LED30WECOCDL or Equivalent apprived from Luker/Havells
30OD337685/2025-2026:Supplying and fixing PVC batten/ angle holder including connection etc. asrequired.
31OD337684/2025-2026:Supply, conveyance, installation, testing and commissioning ofceiling fans of the following sizes using standard accessoriesexcluding resistance type regulator, wiring the down rod with16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3core round copper conductor flex wire or with extended originalwiring etc. as requiredCrompton High speed 1200mm sweep -5star rated ceiling fan or equivalent complete with 300mm down rod , canopies, shackeles and blades
32OD337683/2025-2026:Supply and installation of suitable size MS rod type fan clamp in theRCC slab as per IS 732 as required.
33OD344513/2025-2026:Supply of superior quality copper earth socket for the following sizeof earth conductor including crimping etc. as required.3.15 mm (10 SWG)
34OD344514/2025-2026:Supply and drawing bare earthing conductors of the following sizesalong with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
35OD344515/2025-2026:Supplying and making end termination with brass compression gland andaluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
36OD344520/2025-2026:Supply & Fixing the following types/ sizes of boxes suitable formodular accessories in surface/ recess including making good thedamages, colour washing etc as required (RoHS compliant )12 module moulded plastic box on surface
37OD344521/2025-2026:Supplying and fixing of following sizes of medium class PVC conduit alongwith accessories in surface/ recess including cutting the wall and makinggood the same in case of recessed conduit as required.25 mm
38OD344522/2025-2026:Supplying and drawing following sizes of FRLS PVC insulated copperconductor, single core cable in the existing surface / recessed steel/ PVCconduit as required.3 x 4 sq. mm
39OD35099/2026-2027:Supply Conveyance, installation, testing and commissioning of 30W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea or equivalent with power factor greater than 0.95 at full load, internal surge protection up to 6 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover/toughened glass complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)Approved make: Crompton/luker/havells or equivalent
40100.98.1008:Engaging Coolie.
41OD35456/2026-2027:Wireman
42CHLORINE ROOM
43OD343286/2025-2026:Supplying and fixing following way, single pole and neutral, sheet steel,MCB distribution board, 240 V, on surface/ recess, complete with tinnedcopper bus bar, neutral bus bar, earth bar, din bar, interconnections,powder painted including earthing etc. as required. (But withoutMCBIRCCB/Isolator8 way, Double door
44OD343285/2025-2026:Supplying and fixing 5 amps to 40 amps rating, 240/415 volts, \\"C\\" curve,miniature circuit breaker suitable for inductive load of following poles inthe existing MCB DB complete with connections, testing andcommissioning etc. as required.Double pole 40A
45OD343284/2025-2026:Supplying and fixing following rating, double pole, (single phase andneutral), 240 volts, residual current circuit breaker (RCCB), having asensitivity current upto 300 milliamperes in the existing MCB DBcomplete with connections, testing and commissioning etc. as required.40 amps, 30 mA
46OD343283/2025-2026:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve,miniature circuit breaker suitable for inductive load of following poles inthe existing MCB DB complete with connections, testing andcommissioning etc. as required.Single pole C6-2 nos, C16-2nos
47OD343282/2025-2026:Supply, laying and clamping of 1 no. PVC insulated and PVCsheathed armoured aluminium power cable, 1.1 KV grade of thefollowing sizes using clamps noted along with the cables, spacing ofclamps not exceeding 60cms, making good the damages , colourwashing etc. as required.3 core 10 sq mm with factory made clamp
48OD343281/2025-2026:Supply & laying of one number PVC insulated and PVC sheathedarmoured aluminium power cable of 1.1KV grade of the followingsizes in ground including excavation of trench of size 35 x 75 cm,refilling the trenchetc. as requiredbut excluding sand cushioning andprotectivecovering (in ordinary soil).3 core 10 sq mm
49OD343280/2025-2026:Supplying and making end termination with brass compression gland andaluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)
50OD343279/2025-2026:Supply and drawing 650/1100 V grade FRLS PVC insulatedstranded single core copper conductor cables conforming to IS 694part I 1990 in the existing surface / recess conduit as requiredincluding giving necessary connections of the following sizes.1.00 sq.mm 3 Run( for light & fan points)
51OD343278/2025-2026:Supplying and drawing following sizes of FRLS PVC insulated copperconductor, single core cable in the existing surface / recessed steel/ PVCconduit as required.3 X 1.5 sq.mm( DB to Lighting switch board & 6A sockets)
52OD343277/2025-2026:Supplying and drawing following sizes of FRLS PVC insulated copperconductor, single core cable in the existing surface / recessed steel/ PVCconduit as required.3 x 2.5 sq. mm( DB to 6/16A sockets,HD exhaust fans)
53OD343276/2025-2026:Supplying and fixing of following sizes of medium class PVC conduit alongwith accessories in surface/ recess including cutting the wall and makinggood the same in case of recessed conduit as required.20 mm
54OD343275/2025-2026:Supply & Fixing the following types/ sizes of boxes suitable formodular accessories in surface/ recess including making good thedamages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
55OD343274/2025-2026:Supplying and fixing following Modular base & cover plate on existingmodular metal boxes etc. as required.8 Module
56OD343273/2025-2026:Supply & Fixing the following types/ sizes of boxes suitable formodular accessories in surface/ recess including making good thedamages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
57OD343272/2025-2026:Supplying and fixing following Modular base & cover plate on existingmodular metal boxes etc. as required.6 Module
58OD343271/2025-2026:Supply & Fixing the following types/ sizes of boxes suitable formodular accessories in surface/ recess including making good thedamages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
59OD343270/2025-2026:Supplying and fixing following Modular base & cover plate on existingmodular metal boxes etc. as required.3 Module
60OD343269/2025-2026:Supplying and fixing following modular switch/ socket on the existingmodular plate & switch box including connections but excluding modularplate etc. as required.3 pin 5/6 amp socket outle
61OD343268/2025-2026:Supplying and fixing following modular switch/ socket on the existingmodular plate & switch box including connections but excluding modularplate etc. as required.5/6 amps switch
62OD343267/2025-2026:Supplying and fixing following modular switch/ socket on the existingmodular plate & switch box including connections but excluding modularplate etc. as required.6 pin 15/16 amp socket outlet
63OD343266/2025-2026:Supplying and fixing following modular switch/ socket on the existingmodular plate & switch box including connections but excluding modularplate etc. as required. 15/16 amp switch
64OD343265/2025-2026:Supplying and fixing modular blanking plate on the existing modular plate& switch box excluding modular plate as required.
65OD343264/2025-2026: Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/wooden block including connection etc as required
66OD343263/2025-2026:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required 1200 mm ,1X20W LED Lamp with heat sink and with box type fixture.
67OD343262/2025-2026:Supply,installation , testing and commissioning of exhaust fansof size up to 600mm in the existing opening, fixing necessary anchorbolts / bolt and nuts etc., as required including giving connectionswith the supplied wire along with the exhaust fanHeavy Duty exhaust fan 600mm , 230V Make: Crompton, bajaj, havells or equivalent
68OD343261/2025-2026:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia includingaccessories, and providing masonry enclosure with cover plate havinglocking arrangement and watering pipe etc. with charcoal/ coke and salt asrequired
69OD343260/2025-2026:Supply and drawing bare earthing conductors of the following sizesalong with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
70OD343259/2025-2026:Supply of superior quality copper earth socket for the following sizeof earth conductor including crimping etc. as required.3.15 mm (10 SWG)
71OD343258/2025-2026:Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea or equivalent with power factor greater than 0.95 at full load, internal surge protection up to 6 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover/toughened glass complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)Approved make: Crompton/luker/havells or equivalent
72OD343257/2025-2026:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea or equivalent with power factor greater than 0.95 at full load, internal surge protection up to 6 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover/toughened glass complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)Approved make: Crompton/luker/havells or equivalent
73OD343256/2025-2026:Supply and installation of outdoor rated SMC/FRP IP55 junction box of approximate size 140x 140 x 95 , with neoprene gasket, stainless steel latches, cable glands and terminal blocks, mounted with anchor fastner or using suitable steel tie / clamp with necessary nuts, bolts and hardware as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57421153
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 15-09-2026
Authority
Authority Name Kerala Water Authority
Work Description Tender for O&M - Water Supply Schemes-Electrical Maintenance-Twss - Urgent Maintenance Of Electrical Wiring And Lighting Equipment At Filter House -General Civil Work
Basic Detail
Tender No 19463/2025
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 09 Sep 2026
Submission Date 15 Sep 2026
Open Date 16 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 795
EMD 8981
Exemption Available
Document List
b1958e11-b4f6-4f4b-872b-5adfdbe11c83.html
BOQ_1471066.xls
KWAGeneralConditionsforeT_1.pdf
Tendernotice_1 (19).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Sep 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

b1958e11-b4f6-4f4b-872b-5adfdbe11c83.html

xls

BOQ_1471066.xls

pdf

KWAGeneralConditionsforeT_1.pdf

pdf

Tendernotice_1 (19).pdf

Disclaimer