Tender For Construction Of Government Ug Higher Secondary School Building At Bhandariguda In The District Of Nabarangpur For The Year 2026-27.
Tender Value
1.48 Crore
Estimated cost
Bid Submission
22 Sep 2026
0 days left
EMD
1.49 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nabarangpur → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Government Ug Higher Secondary School Building At Bhandariguda In The District Of Nabarangpur For The Year 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation in foundation in Hard of soil including hard moorum, stoney earth mixed with boulders ( except sheet rocks and boulders requiring blasting) with all leads and lifts including rough dressing the bed and depositing the excavated earth at places away from work site with all leads and lifts including cost of all labour and T&P required for the work complete as per direction of the Engineer-in-charge. |
| 2 | GROUND FLOOR |
| 3 | APPROACH ROAD |
| 4 | Supplying, filling in foundation and plinth with sand in layers well watered and rammed including cost, conveyance, royalty of all the materials required for the work labour with T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 5 | GROUND FLOOR |
| 6 | APPROACH ROAD |
| 7 | Cement Concrete (1:3:6) in foundation and floors using 4cm size black broken granite aggregates of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceding 15cm (6\\") thick to the required level ramming, watering, curing etc. complete including cost and conveyance royalty, taxes of all materials and labour with T&P required for the work etc. complete as per direction of the Engineer in charge. |
| 8 | GROUND FLOOR |
| 9 | APPROACH ROAD |
| 10 | Cement concrete (1:2:4) with 12mm. Size hard broken granite chips (Crusher broken) including all cost, conveyance , royality etc. complete. |
| 11 | GROUND FLOOR |
| 12 | RCC work of M 25 grade with 20 mm and down grade black hard granite (Crusher broken) stone chips including hoisting and laying including all cost, conveyance , royality etc. complete. |
| 13 | GROUND FLOOR |
| 14 | Footing |
| 15 | Column up to Plinth beam Level |
| 16 | Plinth Beam |
| 17 | Column |
| 18 | Roof Beam |
| 19 | Lintel |
| 20 | Roof Slab |
| 21 | Stair Case |
| 22 | Chajjas |
| 23 | TERRACE FLOOR |
| 24 | Column |
| 25 | Roof Beam |
| 26 | Roof Slab |
| 27 | Providing HYSD bars including cutting, bending, binding and tying the grills and placing in position including cost, conveyance and royalty of all materials and cost of all labour etc. complete |
| 28 | GROUND FLOOR |
| 29 | TERRACE FLOOR |
| 30 | Fly ash Brick masonary with C.M (1:6) in Foundation including cost ,conveyance, royalty & taxex of all materials, labour, T&P etc. complete including watering and curing for required period as per the direction of the Engineer in charge. |
| 31 | GROUND FLOOR |
| 32 | Fly ash Brick masonary with C.M (1:6) in Superstructure including cost ,conveyance, royalty & taxex of all materials, labour, T&P etc. complete including watering and curing for required period as per the direction of the Engineer in charge. |
| 33 | GROUND FLOOR |
| 34 | TERRACE FLOOR |
| 35 | 20mm thick Cement plaster in C.M (1:4) including punning over walls, finished smooth including watering curing and scaffolding with cost, conveyance, royalty, taxes of all the |
| 36 | GROUND FLOOR |
| 37 | Coal taring two coats including cost of coal tar and tar paper with all cost, conveyance, labour, T&P and cess etc. complete as per specifications and direction of the Engineer-in-charge |
| 38 | GROUND FLOOR |
| 39 | 16mm thick inside Plastering with cement mortar(1:6) including all cost and conveyance, royalty, taxes of all materials etc. complete as directed by the Engineer in Charge. |
| 40 | GROUND FLOOR |
| 41 | TERRACE FLOOR |
| 42 | 12mm thick outside Plastering with cement mortar (1:6) including all cost and conveyance, royalty, taxes of all materials etc. complete as directed by the Engineer in Charge. |
| 43 | GROUND FLOOR |
| 44 | TERRACE FLOOR |
| 45 | Fixing vetrified tiles of 600 x 600mm in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing with cost carriage royalty of all materials etc. complete. |
| 46 | GROUND FLOOR |
| 47 | Supplying, fitting and fixing of Vitrified tile (In dados / skirting) of premium grade having thickness 8mm to 10mm conforming to IS 13756 of size 60cm x 60cm plain (Ivory) in floors with application of polymer modified cement based water resistance adhesive bed of required thickness of 10 mm and filling joints with epoxy grout of approved quality including cost of all materials, labour, T&P, taxes etc. complete required for the work as per direction of the Engineer-in-charge. |
| 48 | GROUND FLOOR |
| 49 | Providing and fixing Kadappa tiles (upto 0.10 Sqm.) in dados, skirtings and risers of steps on 12 mm thick cement plaster (1:3) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles as directed by the Engineer-in-charge. |
| 50 | GROUND FLOOR |
| 51 | Fixing chequred tiles in floors, treads and landings on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile. |
| 52 | GROUND FLOOR |
| 53 | Finishing walls with weather seal coat (two coats) over a coat of cement primer to outer walls surface including cost and conveyance of all materials to site, and all labour charges complete as per direction of Engineer in Charge. |
| 54 | GROUND FLOOR |
| 55 | TERRACE FLOOR |
| 56 | Wall painting 2 coats with plastic emulsion paint of approved shade on new work to give an even shade including cost of paint. |
| 57 | GROUND FLOOR |
| 58 | TERRACE FLOOR |
| 59 | Finishing wall surface of wall with Acrylic Wall Putty (Water based) of approved make and finished smooth and even surface to receive painting including cost conveyance and royalties of all materials etc complete as per direction of the Engineer in Charge. |
| 60 | GROUND FLOOR |
| 61 | Providing, fitting and fixing of 32 mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all fittings and fixtures etc. Complete. |
| 62 | GROUND FLOOR |
| 63 | Providing, fitting and fixing of WPC Door frame (100 x 75 mm) with approved quality including cost of all fittings and fixtures etc. complete. |
| 64 | GROUND FLOOR |
| 65 | Providing & Fixing of M.S. Door & Window and window Grills including cost and conveyance of all materials to site, and all labour charges etc complet as per direction of E.I.C. |
| 66 | GROUND FLOOR |
| 67 | TERRACE FLOOR |
| 68 | Supplying, fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 69 | GROUND FLOOR |
| 70 | Providing and fixing of Partly fixed, partly top hung and partly louvered windows of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6 mm thick D quality, galvanized as per IS-277 with zinc of 120 Gm/Sq.mtr) with paint specification being with primer of 5 7 microns and finished paint with polyster paint (Black /Pearl white/ Chocolate Brown) of 12 16 microns alongwith the alkyd backer at the back of 5-7 microns and the sizes of outer frame being of 46x52 mm and with all vertical and horizontal mullions are of 46x70 mm and fixed beadings are of 18x25 mm. Section for internal top and bottom frames in the louvered areas should be 18 x 40 mm.Top hung shutter should be of 46 x 46 mm. Accessories / gaskets are to be used as per the manufacturers supply and specification like handle being made of high grade aluminium powder coated and with nylon receiver and gasket will be made of EPDM. All corner brackets are to be made of CRCA with zinc phosphating. The mullion caps and louvered-clips should be of glass filled nylon. The sections are to be cut to length ,mitre joined with corner bracket and frames are fixed to the concrete/masonry walls by means of self expanding screws and glass to be used of 5 mm reflective with all taxes complete. |
| 71 | GROUND FLOOR |
| 72 | Painting two coats over wood and iron work with approved Enamel paint over a coat of priming including cost and conveyance of all materials to site and all labour charges complete as per direction of E.I.C. |
| 73 | GROUND FLOOR |
| 74 | TERRACE FLOOR |
| 75 | Supplying, fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost conveyance, taxes of all materials labour, T&P etc. required for the complete in all respect. |
| 76 | GROUND FLOOR |
| 77 | 2.5 cm. thick grading concrete (1:2:2) on roof slab with 6mm. size hard granite chips on new work. |
| 78 | GROUND FLOOR |
| 79 | TERRACE FLOOR |
| 80 | Providing and applying of pre contructional antitermite treatment by drilling 12 mm dia holes at distance of 30 cm @ junction wall & floors about 300 mm apart deep enough to reach the soil below & chemical emulsion ( PREMISE,IMIDACHLOPRIED30.5SC OF BAYER MAKE mixed with 47.5 ltrs water) pumped these holes to soak the soil @ 1 Ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials,labour,conveyance,T&P,all taxes and hire charges of machinaries as per direction of Engineer-in-charge. |
| 81 | GROUND FLOOR |
| 82 | Labour for fixing of M.S doors and windows shutters of approved design in proper position making good to the damges of walls of R.C.C or other structural etc. including mending or cutting sizes or grooves in chaukhats with cost, conveyance, taxes, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 83 | TERRACE FLOOR |
| 84 | Providing and fixing rain water down pipe with necessary bend shoes and heads including cost of 75mm dia earthen pipe, clamps and nails etc. with all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge |
| 85 | TERRACE FLOOR |
| 86 | Providing and laying of 80 mm thick factory made cement concrete interlocking paver block of M-30 grade and approved make, varity, colour and size made by Block making machine with strong vibratory compaction of approved design and shape laid in required colour and pattern over 50 mm thick compacted bed of course sand, filling the joints with fine sand etc. all complete include cost, conveyance, royality, taxes of all materials, labour T&P etc, complete as per direction of Engineer-in-Charge. |
| 87 | GROUND FLOOR |
| 88 | Labour for drilling a perfectly vertical bore hole at specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination rigs as required to suit the site condition as per the direction of the Engineer-in-charge including use of own rigs with its accessories, tools and plants and consumables etc for lowering of 125 mm dia P.V.C/G.I/MS pipes for housing fitted socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/P.V.C/M.S casing pipes if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after completion of the tubewell) Drilling of 200 mm dia bore :-00 mtr to 40.00 mtr For Rain Water Harvesting 5 nos 10mtr Each.( 50+5x10) |
| 89 | Drilling of 150 mm dia bore :- 41 mtr to 100 Mtr |
| 90 | Lowering of the following size G.I/P.V.C pipes with or without slotted pipes as per the necessary from ground level upto 30 mtrs depth and fitted and fixed up in perfectly vertical position including cutting and threading pipes and slotted pipe and supplying and fixing all jointing materials, tools and plants complete and keeping the top of the casing pipe threaded including plugging tubewell to prevent entry of foreign materials from above. Lowering of 125 mm dia PVC pipes :- 00mtr to 30.00 mtr |
| 91 | Cost of 200 mm dia PVC pipes:-00 mtr to 30 mtr |
| 92 | Supplying and fitting & fixing of I.S.I make 1.00 H.P single phase Submersible Pump set to give discharge of 3000 ltr/hour at a head of 40 mtr etc all complete as direction of EIC. |
| 93 | Supplying and fitting & fixing of D.O.L starter for 1.0 H.P single phase Submersible Pump etc all complete as per direction of E.I.C |
| 94 | Supplying and fitting & fixing of suitable cable and connecting the pump and starter etc all complete as per direction of E.I.C |
| 95 | Supplying and fitting & fixing of Plastic rope, M.S well cover, M.S clamp, etc all complete as per direction of Engineer-in-charge. |
| 96 | Supplying and fitting & fixing of HDPE pipes and pipe fittings with C.P Nippling and lowering to bore well, making connection to pumpset & testing etc all complete as per specification and the direction of the E.I.C. 32 mm dia HDPE Pipe |
| 97 | Supplying all materials, labour, T&P and Fitting and Fixing of Rotational moulded polythene cylindrical vertical water storage tank conforming to 15701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts, including hoisting upto a height of 5 mtr above G.Land placing the tank in required position including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 2000 lits capacity on the roof of GF |
| 98 | Supplying all materials, labour, T&P and construction of masonry staging with providing 1st class K.B. Brick work in C.M.(1:6) of 0.46mtr height in staging, 12 mm cement plaster in C.M (1:6), R.C.C. Beam of 0.25mx0.30mx2.60m & roof slab of 1.40mx1.40m in C.C (1:1.5:3) using 12mm size H.G.Chips including centering, shuttering, bending and binding of rod etc watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 2000 lits capacity on the roof of GF |
| 99 | Supplying all materials, labour, T&P and constructing Inspection Chamber of the following sizes with cement concrete (1:3:6) using 40 mm size HG metal on bed, 1st class KB Brick work in CM (1:6) moulding and shaping the channel inside and benching with C:C (1:1.5:3) using 12 mm size H.G chips, 12 mm thick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in C.C(1:1.5:3) using 12 mm size H.G chips with RCC man hole cover, etc. all complete as per approved specification and direction of E.I.C Inside size 760mm x 760mm x 460mm |
| 100 | Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8 cm thick precast cover slab in CC (1:2:4) mix using 12 mm size H.G chips, foundation concrete (1:4:8) using 40 mm size HG metal on bed and around trap , !st class KB Brick work in CM (1:6) in F & P and inside 12 mm thick cement plaster (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap 150mmx150mm size C.I grating etc. all completed as per approved drawing, specification and direction of E.I.C. |
| 101 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class KB brick work in CM (1:6) for the remaining height at top, 12mm thick Cement Plaster (1:4) inside and outside over masonry brick work, gravel packing in the rear of well steining, RCC cover slab in CC (1:1.5:3) using 12mm HG chips, fitted with iron lifting handles. etc all complete as per approved specification and direction of the E.I.C. 0.90 m diax 2.0 m deep soakway pit |
| 102 | 1.20 m diax 2.0 m deep soakway pit |
| 103 | Metal Packaing 40mm size Crusher broken insite the pit |
| 104 | 5Nos x 0.80m x (0.785*1.2^2) |
| 105 | Metal Packaing 12mm size Crusher broken insite the pit |
| 106 | Sand Packaing insite the pit |
| 107 | Supplying all materials, labour, T&P and laying in trenches U-PVC SWR/4Kg/cm2 soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and providing bed concrete in P:C:C (1:4:8) using 40 mm size metal and haunch top the pipe with refilling of trenches etc all complete as per P.H specification and direction of the E.I.C. |
| 108 | 110mm Hunch Top |
| 109 | 160mm PVc Pipe all round Hunch top |
| 110 | Earthwork in all kinds of soil in excavation of foundation trenches within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth etc all complete as per direction of the E.I.C. |
| 111 | Initial lift upto 1.5 mtr |
| 112 | 2Nosx 4.37 m x 3.18 m x 1.50 m |
| 113 | From 1.5 mtr to 3.0 mtr depth |
| 114 | 2 Nosx 4.37 m x 3.18 m x 0.70 m |
| 115 | Supplying all materials, labour, T&P and filling in foundation and plinth with river sand well watered and rammed including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per the direction of the E.I.C. |
| 116 | 2 Nosx 4.37 m x 3.18 m x 0.15 m |
| 117 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm H.G metal including watering, curing and conveyance of all materials to site payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 118 | 2Nosx 4.37 m x 3.18 m x 0.10 m |
| 119 | Supplying all materials, labour, T&P and providing plain cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 120 | 2 Nosx 4.37 m x 3.18 m x 0.10 m =1.389 Cum |
| 121 | 2 Nosx3.07 m x 1.88 m x 0.038 m = 0.219 Cum |
| 122 | Supplying all materials,labour, T&P and providing Brick work with K.B.Brick having crushing strength not less than 75 Kg/CM2 with dimensional tolerence of +/- 8% in C.M including watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 123 | In Foundation and Plinth in C:M (1:4) |
| 124 | 2Nosx 2 x ( 4.07 + 1.88 ) m x 0.50 m x 1.10 m |
| 125 | 2Nosx 2 x ( 3.82 + 1.88 ) m x 0.375 m x 0.80 m |
| 126 | Supplying all materials, labour, T&P and providing cement plaster on brick/stone work including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 127 | 12 mm thick C.P in C:M (1:3) |
| 128 | 2Nosx 2 x ( 3.07 + 1.88 ) m x 1.90 m |
| 129 | 2Nosx 3.07 x 1.88 m |
| 130 | Supplying all materials, labour, T&P and providing cement punning on plastered surface including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 131 | Same as above item 20mm C.P in 1:3 |
| 132 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling them after casting including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the Engineer-in-charge. |
| 133 | 2Nosx 2 x (3.82 + 2.63 ) m x 0.125 m |
| 134 | 2Nosx 3.07 m x 1.88 m |
| 135 | Supplying all materials, labour, T&P and providing M.S.reinforcements for RCC work including cutting, bending, binding, straightening and tying the grills and placing in position including cost of binding wire 18 to 20 gauge conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the Engineer-in-charge. |
| 136 | Supplying all materials, labour, T&P and providing Reinforced cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 137 | 2Nosx 3.82 m x 2.63 m x 0.125 m |
| 138 | Supplying all materials, labour, T&P and making M.S. Step Iron in 20mm Dia M.S Steel bars and fixing into walls of Manhole/ Septic Tanks duly embeded in C.C(1:2:4) etc all complete as per P.H specification and direction of the Engineer-in-charge. |
| 139 | Supplying all materials, labour, T&P and providing 50mm thick pre-cast R.C.C. baffle wall in R.C.C(1:1.5:3) including reinforcement cage using 12mm size HG chips fitted and fixed in position, finished smooth etc. complete including cutting grooves and mending good the damages etc all complete as per P.H specification and direction of the E.I.C. |
| 140 | 2Nosx 2.20 m x 0.45 m |
| 141 | Supplying all materials, labour, T&P and providing 160mm dia P.V.C Tee inside the septic tank including cutting holes and duly embeded in P.C.C(1:1.5:3) using 12mm size HG chips fitted and fixed in position and mending good the damages etc all complete as per P.H specification and direction of the E.I.C. |
| 142 | Supplying all materials, labour,T&P and providing 12mm thick cement flush pointing in C:M (1:3) to Brick Masonry works including watering curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the Engineer-in-charge. |
| 143 | 2Nosx 2 x ( 4.07 + 2.88 ) m x 1.10 m |
| 144 | 2Nosx 2 x ( 3.82 + 2.63 ) m x 0.80 m |
| 145 | Nosx 2 x ( 4.07 + 2.63 ) m x 0.125 m |
| 146 | Supplying all materials, labour,T&P and filling Foundation and Plinth with excavated earth including watering, ramming etc all complete as per direction of the E.I.C. |
| 147 | SanitaryInstalation/Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing etc all complete as per P.H specification and direction of the E.I.C. 110mm diameter U-PVC SWR pipes |
| 148 | 110mm U-PVC SWR P-trap |
| 149 | 110mm U-PVC SWR Single junction door |
| 150 | 110mm U-PVC SWR door bend |
| 151 | 110mm U-PVC SWR Offset |
| 152 | 110mm U-PVC SWR plain bend |
| 153 | 110mm U-PVC SWR vent cowl |
| 154 | 75 mm diameter U-PVC SWR pipes |
| 155 | 75 mm U-PVC SWR plain bend |
| 156 | 125 mm dia C.P Grating |
| 157 | Internal PH Works |
| 158 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling or floor G.I./PVC pipes and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling,and floor, testing all complete as per specification and the direction of the E.I.C. 20mm dia C- PVC pipes Internal |
| 159 | 25mm dia C-PVC pipes External |
| 160 | supplying all materials, labour, T&P and cutting holes through existing brick/stone masonry walls for taking GI/PVC pipes and fittings including making good the damages in cement mortar (1:4) etc. all complete as per P.H. specification and direction of E.I.C. R.C.C Roof/Chaja |
| 161 | Cutting Groove in wall or floor |
| 162 | Cutting hole(250 mm wall) |
| 163 | Cutting hole(375 mm wall) |
| 164 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in floors, on 25mm thick bed of cement mortar 1:1 joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. all complete as per specification and direction of the E.I.C. |
| 165 | Ground Floor |
| 166 | 2nosx7.0x2.4m=34.00 Sqm |
| 167 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados/skirtings on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing etc. all complete as per direction of the E.I.C. |
| 168 | Ground Floor |
| 169 | 2nos 35.00mx2.10=147.00 Sqm |
| 170 | 2nos x 2x2=8.0 Sqm |
| 171 | Supplying all materials, labour, T&P and fixing water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest etc all complete as per specification and direction of the E.I.C.580mm size Orissa pan(Hindware,Parryware) |
| 172 | Flat Back lipped wall urinal |
| 173 | Supplying all materials, labour, T&P and fixing Eoropian Watter closet and seat cover with 'P' trap plain etc all complete as per specification and direction of the E.I.C. |
| 174 | Supplying all materials, labour T&P and fitting & fixing 10 Litres capacity low level cistern with a pair of cast iron of m.s. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float, c.p. brass handle, unions and couplings for connection with inlet, outlet and overflow pipe. 32 mm C.P flush bend 15mm PVC inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting inlet pipe with supply main etc. all complete as per specification and direction of E.I.C (Cerra/ Parry ware/ Hindware) |
| 175 | Supplying all materials, labour T&P and fitting and fixing of C.P Shower(Parryware,Hindware) with 15mm or 20mm inlet with C.P Shower arm including polishing etc all complete as per specification and direction of the E.I.C 15 mm x 150mm dia C.P Shower with arm |
| 176 | Supplying all materials, labour T&P and fixing wash basins(Hindware,Parryware) with C.I. or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the E.I.C. 550mmx400mm size wash hand basin |
| 177 | Pedestal For Basin |
| 178 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the E.I.C. |
| 179 | Supplying all materials,labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the E.I.C 20mmx450mm long CP towel rail |
| 180 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the E.I.C |
| 181 | Supplying all materials, labour, T&P and fitting and fixing Brass/CP fittings(Jaquar Make) of the following nominal bore with supply of all jointing materials etc. all complete as per specification and the direction of the E.I.C. 15mm dia CP Bib Cock SB |
| 182 | 15mm dia CP Bib Cock LB |
| 183 | 15mm dia CP Pillar Cock |
| 184 | 15mm dia 2 in 1 way Bib Cock |
| 185 | 15mm dia CP Angle Stop Cock |
| 186 | 15mm dia CP Concealed Stop Cock |
| 187 | 25mm dia Brass Full Way Valve |
| 188 | Aquaguard Hot & Cold RO + UV Wall & Table Mount 11 L Storage Water Purifier |
| 189 | Factory made FRP(alternately called GRP) door frame of size 75mmx100mm fabricated using E-glass Chopped Strand Mat (CSM) U.V stabilised Inopthalic Gelcoat and impregnated with Inopthalic resin. The thickness of the GRP skins shall not be less than 2.00mm. The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The GRP frame shall be provided with wooden reinforcement on six locations for high screw holding capacity for for fixing metallic hold fast and shall be consolidated by filling with medium density foam/plaster of paris with fibre reinforcement, Six numbers of 260mm x 25mm x 5mm size 'S' shaped M.S flat hold fast shall be provided with the frame. The material and process for manufacturing the door frames shall conform to RV-TIFAC composites Design Centre's standards and specifications. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the E.I.C |
| 190 | 8x( 2.10+0.75+2.10) |
| 191 | Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 1.50mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/Light grey/ Mahogany/Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 192 | 8nos x(0.70x2.0)=11.00 Sqm |
| 193 | ELECTRICAL |
| 194 | Wiring |
| 195 | Recessed wiring to light point with 1.5 sq.mm FRLSH PVC insulatedsingle core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front Modular base & cover of suitable size , MS box with 1 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels /HPL/ V Guard ) |
| 196 | -do- Group A |
| 197 | -do- Group B |
| 198 | -do- Group C |
| 199 | Recessed wiring to Fan Point in |
| 200 | -do- Group B |
| 201 | -do- Group C |
| 202 | Recessed wiring to Exhaust Fan Point in |
| 203 | -do- Group B |
| 204 | S/F of Angle holder replacing Ceilling Rose |
| 205 | Switch Boards |
| 206 | S/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board (1.25.1+1.25.4) |
| 207 | S/F of extension board of 6 modular Metal box with modular base & cover in recess including providing and fixing of 2 nos of 3pin 5/6amp modular socket out let & 2 nos of 5/6 amp piano type modular switch, connection, painting etc as required. |
| 208 | S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 6 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required |
| 209 | S/F of Power point with 4 modular & 2 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket & Mini DP MCB, connection, painting etc as required for AC |
| 210 | S/F of computer board consisting of 3 nos of 5amp modular plug and modular switch & 1 no of Mini MCB complete with wiring on 12 modular M.S. box with modular cover. |
| 211 | S/F of 1 no of 5 pin 15/16 amp. Socket , 1 no of switch & 1 no of 15/16A top with modular mini MCB, in 6 modular box with cover with connection, painting etc as required for Inverter connection. |
| 212 | S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required. |
| 213 | 2 Modular box with base & cover |
| 214 | 6 Modular box with base & cover |
| 215 | 8 Modular box with base & cover |
| 216 | 12 Modular box with base & cover |
| 217 | Sub-Main |
| 218 | Wiring for circuit / sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire - Finolex/L&T/Anchor/Havels/V-guard) |
| 219 | 2x1.5+1x1.5 (1.8.1) |
| 220 | 2x2.5+1x1.5 (1.8.2) |
| 221 | 2x4+1x1.5 (1.8.3) |
| 222 | 4x10+2x4(1:8:11) |
| 223 | Inverter wiring (1x2.5smm) Copper wire (1.19.11A) |
| 224 | Circuit Breakers & BDB |
| 225 | S/F of 'B/C/D' series SP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP) (2.6.1) |
| 226 | S/F of 'C' series 4 Pole MCB of 63A amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box. |
| 227 | Supply, Installation testing & commissioning of Main Switches (IS13940 part 3/1993) of following coopacity on existing surface/wall mounting & complete with H.R.C fuse links, inter connections earthing etc as required as per direction of Engineer Incharge (Make-Seimens/HPL/Anchor/L&T /Havels/C&S/R. K.) |
| 228 | S/F of 4 way (4+12) TPN MCB DB double door (2.5.5) |
| 229 | Earthing |
| 230 | Supply & laying 6 SWG G.I. wire in recess for loop earthing as required (3.17) |
| 231 | Item No.4. EARTHING-Provision of maintenance free Chemical Earthing with 250 micron non corrosive copper bonded rod (CPRI Certified) of 2.4 mtr length and minimum 17.2 mm dia with provision of 25kg x 2=50kg back filling ground resistance improvement compound with ROHS certified including supply and installation of heavy duty envionmental friendly poly plastic earth pit chamber with cover as per I.E Rules .The earthing should be minimum 1.5 mtr. away from the building and the two earthings must be 10 feet apart from each other as per I.E Rules . |
| 232 | Fittings |
| 233 | Providing & fixing plain 16/0.2mm twin twisted flexible, FR PVC insulated copper cable in polythene sleeve or conduit of suitable size on the floor/wall or side of the table/door etc as required.(1.31) |
| 234 | S/F of 300 Exhaust fan with all accessoriesand connections (Make Usha-Aero Clean Plus DBB/ Polycab-Fresh on DBB/ Cropmton-Trans Air12\\" reversible/ Havells-Ventil Air DS(HS)/ Anchor-Anmol Delus R/ Orient-Power Flow DBB) |
| 235 | S/F of 18-25 wt. LED single strip tube. Light fittingwith all accessories & connection (make Havels/HPL/Crompton/Polycab/PAC) |
| 236 | S/F of 1200mm A.C. Ceiling fan (1Star) with all accessories and connections with out fan regulator (Make:Usha-Striker One/Neo/Crompton- highspeed/Havells-Samrat ES/Anchor- Turbo Speed Star/Orient-Summer Breeze Pro/ Great White-ALDOUS/Pollycab-Vital HS) |
| 237 | Fixing /I.T.C. of stepped type Modular regulator (1.25a) |
| 238 | S/F of 20mm dia down rod with all accessories (1.39+1.41) |
| 239 | Supply & fixing of superior type C.I bulk head fitting with 9W Led Bulb for general domestic use ISI marked square / oval type with premetallic glass cover provided with galvanized steel wire guard including necessary connections. ( M-5 ) |
| 240 | S/F of 60 wt. LED St. Light fitting with LED Electronic driver with all accessories & connection( Make- Crompton/Phillips/HPL/Polycab/Havells ) |
| 241 | S/F of 12w Watt LED Bulb |
| 242 | S/F of 2T ,5 Star,Inverter model, Split A.C Machine(Make- Hitachi(V522PCBISH1)/Blue star(IC524DNUR)/Carrier(CAI24CE5R35F0)/Daikin/LG/Mitsubishi/O-General) |
| 243 | S/F of Stabilizer (90-300V) 5KVA with 16A Delux plug Top(Make- V-Guard/Microtek) |
| 244 | Provision of 40mm dia HDPE pipe for laying & protection of cable |
| 245 | S/F of 2000VA/24V Invertor machine,Make-Heavy duty V-Turbo UPS-23509 (microtek)/PRIME 2250(V-GUARD)/EVO S 2300(LUMINOUS) and 180Ah tall tubular BatteryMake-Luminous /microtek/v-guard and 16A Delux plug Top with Luminous single Trolley for Inveryor Battery,2nos |
| 246 | Cables |
| 247 | Provision of Armoured cable size 3 1/2 x70sqmm (27) |
| 248 | Laying of MV cable above 25sqmm to 120 sqmm in ground (5.1.2) |
| 249 | Laying of MV cable above 25sqmm to 120 sqmm on surface (Horizontally)(5.5.2) |
| 250 | Panels |
| 251 | Supply & fixing of 100 A TPN Panel board 1. 100A MCCB (Make- Legrand/Seimens/L&T/C&S/) & 100A kitkat & bus bar2. 32 A TPN MCB (Make- Legrand/Seimens/L&T/C&S/)- 2nos 3. 32A DP MCB (Make- Legrand/Seimens/L&T/C&S/)- 5 nos 4. 100 A 4P Manual changeover (Make- Legrand/Seimens/L&T/C&S/)- 1nos5. Digital Volt meter & Ameter three phase 6. All accesories & Connection (Rating & Danger borad) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodaySep 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender