Tender For Deposit-Completion Work Of Ksrtc Bus Terminal Cum Shopping Complex, Malappuram-Phase 2-Composite Work
Tender Value
3.03 Crore
Estimated cost
Bid Submission
24 Sep 2026
9 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
8270
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Malappuram → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Deposit-Completion Work Of Ksrtc Bus Terminal Cum Shopping Complex, Malappuram-Phase 2-Composite Work
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 09-Sep-2026 | Electrical conditions | Other | 24-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKS(Civil work) |
| 2 | 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 3 | 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 4 | 6.47:Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry150mm/230mm/300 mm thick with Grade- I AAC blocks in super structureabove plinth level up to floor V level with RCC band at sill level and lintellevel with approved block laying polymer modified adhesive mortar allcomplete as per direction of Engineer-in-Charge. (The payment of RCC bandand reinforcement shall be made for seperately). |
| 5 | 50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 6 | 50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete |
| 7 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 8 | 13.26:Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 9 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 10 | 13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 11 | 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 12 | 9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding |
| 13 | 10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 14 | 8.10.2:Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade |
| 15 | 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 16 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 17 | 22.6:Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) |
| 18 | 11.41.3:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 800x 800 mm |
| 19 | 11.47.3:Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 800x800 mm |
| 20 | 11.48.3:Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 800x800mm |
| 21 | 21.1.2.3:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micorn) |
| 22 | 21.13:Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pair of handles ( best make of approved quality ) for aluminum doors including necessary cutting and making good etc. complete |
| 23 | 21.1.1.3:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron ) |
| 24 | 21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 25 | 21.2.1:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side |
| 26 | 21.3.3:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) |
| 27 | 9.100.1:Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm |
| 28 | 10.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 29 | 12.45.3:Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board |
| 30 | 9.101.1:Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper |
| 31 | OD295027/2025-2026:Pressed Steel door of standard pattern with frame as per profile of IS 4351 of section 105 x 60mm using 18 g (1. 2 mm thick C R C A) sheet and shutters made of section 75 x 30 cm for outerstyles and horizontal members and then adopted with enclosed and stiffned sheet 26 CR as perspecification with zinc romate primer coat measured in sequence meter totally including allcharges for fixing handle Loocks but hinges etc.complete. |
| 32 | 9.83:Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 33 | 9.97.3:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm |
| 34 | 50.9.15.2:Supplying and fixing 300 mm Aluminium aldrop |
| 35 | 10.6.2:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover |
| 36 | 10.7:Providing and fixing ball bearing for rolling shutters. |
| 37 | 25.1:Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminum extruded section shall be taken for purpose of payment |
| 38 | OD72546/2026-2027:Providing and fixing Aluminium Composite Panel (ACP) cladding to the exterior surface of walls using 4 mm thick PVDF coated ACP sheets with minimum 0.30 mm thick aluminium skin on both sides and FR grade core, of approved colour and shade, over the existing aluminium framework. The ACP panels shall be fixed horizontally and vertically using 6 mm × 6 mm spacer foam tape and self-drilling/self-tapping stainless steel screws, including all necessary accessories, ensuring proper drainage of water entering the curtain glazing system to make the system watertight, complete with all materials, labour, conveyance and incidental charges, as directed by the Engineer-in-Charge. (Data prepared with reference to CPWD Specifications No. 25.7) |
| 39 | 9.121:Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 40 | 9.122.2:Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge. |
| 41 | OD295033/2025-2026:Supplying and laying interlocking tile 100 mm or nearest size thickness, minimum strength M 40 including providing a layer of 6 mm aggregate for 5 cm thickness, then laying interlock cobbles in lines and lev |
| 42 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 43 | 2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock |
| 44 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 45 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 46 | 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 47 | 5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 48 | 13.37.1:White washing with lime to give an even shade:New work (three or more coats) |
| 49 | 15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. |
| 50 | 13.9.2:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.20 mm cement plaster |
| 51 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 52 | 15.9.1:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In Lime Mortar |
| 53 | OD295031/2025-2026:Providing and fixing V board panelling 15mm thick,to frame backing or studding with screws etc.(frames backing or studding to be paid seperately) as per the direction of sie Engineer in charge. |
| 54 | 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 55 | 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 56 | OD295029/2025-2026:DRY RUBBLE MASONRY - Dry rubble without concrete levelling course masonry with good quality blasted rubble including chips for retaining wall including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per the direction of Departmental officers at site. |
| 57 | 50.6.1.4:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete |
| 58 | 2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 59 | 7.2.1:Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 60 | 16.11:Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete. |
| 61 | 12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 62 | OD295032/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess cement used as per design mix is not payable separately as per circular number CE/BL/GL/6541/2015 Dt.30.08.17 of CE,BLDGS PWD). All work above plinth level upto floor V level |
| 63 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 64 | OD295028/2025-2026:Providing and fixing stainless steel (304) 3D letters of 18 Guage , 12 to 20mm Projection of different heights , including welding grinding , buffing , polishing and making curvature ( Where ever Required ) and fitting the same with necessary stainless steel nuts and bolts complete with suitable arrangement as per approval of engineer incharge ( for payment purpose number and height of letters shall be considered excluding fixing accessories such as nuts , bolts, fasters , etc )Consider cost for 12 Letters of 30Cm Height |
| 65 | plumbing work(Civil work) |
| 66 | 50.18.8.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2 |
| 67 | 50.18.9.8.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2 |
| 68 | 50.18.7.4.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall |
| 69 | 50.18.9.9.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 |
| 70 | 50.18.9.21:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow |
| 71 | 50.18.9.21.2:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow |
| 72 | 50.18.9.21.3:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia Door Elbow |
| 73 | 50.18.9.21.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend |
| 74 | 50.18.9.21.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x75x75 mm dia Tee |
| 75 | 50.18.9.21.6:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee |
| 76 | 50.18.9.21.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl |
| 77 | 50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow |
| 78 | 50.18.9.22.2:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow |
| 79 | 50.18.9.22.3:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow |
| 80 | 50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 81 | 50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 82 | 50.18.9.22.6:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 83 | 50.18.9.22.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x75 mm dia Door Tee |
| 84 | 50.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 85 | 17.23:Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 86 | 17.29:Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 87 | 17.1.1:Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 88 | 17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid |
| 89 | 17.10.1.1:Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm |
| 90 | 17.31:Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 91 | 50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 92 | 50.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 93 | 50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. |
| 94 | 18.15.2:Providing and fixing brass bib cock of approved quality :20 mm nominal bore |
| 95 | 18.16.2:Providing and fixing brass stop cock of approved quality :20 mm nominal bore |
| 96 | 18.18.3:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore |
| 97 | 18.22.2:Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter |
| 98 | 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 99 | 18.51.1:Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 100 | 18.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 101 | 18.77:Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 102 | 17.76.1:Providing and fixing PTMT urinal cock of approved quality and colour.15 mm nominal bore, 80 mm long 42 mm high and 30 mm wide with BSP female threads weighing not less than 48 gms . |
| 103 | 17.7.2:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap |
| 104 | Electrification(Electrical work) |
| 105 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 106 | 1.54.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 107 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 108 | 90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture |
| 109 | 90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture |
| 110 | 90.3.24.3:Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture |
| 111 | OD327554/2025-2026:Supply,Conveyance, installation, testing and commissioning of 1800 lumen round/square surface/recess fitting made of die cast aluminum, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10% directly on ceiling and giving connections with 16/0.20mm 3 core PVC insulated and sheathed round copper conductor flexible wire or extending the original wiring and giving connections as required.(Chip make Cree/Osram/lumilled/Nichea/Bridgelux) |
| 112 | OD331712/2025-2026:Supply,Conveyance, installation, testing and commissioning of 3000 lumen square LED surface/recess fitting made of die cast aluminum,having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10% directly on ceiling and giving connections with 16/0.20mm 3 core PVC insulated and sheathed round copper conductor flexible wire or extending the original wiring and giving connections as required.(Chip make Cree/Osram/lumilled/Nichea/Bridgelux) |
| 113 | OD327551/2025-2026: Supply ,installation,testing and commissioning of 700lm pressure die cast housing Bulk head with IP65 protection & IK 08 having efficacy not less than 105lm/W and giving connection with 3 core flex wire as required |
| 114 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. |
| 115 | OD53121/2026-2027:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 116 | 1.47:Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 117 | OD327556/2025-2026:Supply, conveyance, installation , testing and commissioning of 225/250 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan. |
| 118 | OD333248/2025-2026:Supply, conveyance, installation, testing commissioning of 5 watts or nearest , LED mirror lamp, Operating Voltage: 160-360 volts Crompton or equivalent make |
| 119 | 90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface |
| 120 | 1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module |
| 121 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 122 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 123 | 1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) |
| 124 | 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 125 | 1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) |
| 126 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 127 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 128 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 129 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 130 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 131 | 90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top |
| 132 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 133 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 134 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 135 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 136 | 1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm |
| 137 | 1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm |
| 138 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 139 | 1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm |
| 140 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 141 | 1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm |
| 142 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 143 | 90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) |
| 144 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 145 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 146 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 147 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 148 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 149 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 150 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 151 | 2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 152 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 153 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 154 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 155 | OD126325/2026-2027:Supply,installation,testing and commissioning of DIN Rail Surge Protection Device (4+0) Class B&C/ Type 1&2 with Total Impulse current-10 KA (10/350? sec) & Total Max Discharge current 200KA (8/20? sec), Voltage protection level <1.5 kV .The Surge Protection Devices should have TOV safefail for 120 Min : 442 V. Health Status Indication in all catridges.Total Response time <25 nano seconds. |
| 156 | OD56929/2026-2027: Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm (clamped with 25/40x3mm MS flat clamp) |
| 157 | OD58203/2026-2027: Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 .5core 120 sq mm (clamped with 25/40x3mm MS flat clamp) |
| 158 | OD57054/2026-2027:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 3.5x95 sqmm (clamped with 25x3mm MS flat clamp) |
| 159 | OD57056/2026-2027:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 3.5x35 sqmm (clamped with 1mm thick saddle) |
| 160 | OD57057/2026-2027:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 4x25 sqmm (clamped with 1mm thick saddle) |
| 161 | OD57060/2026-2027: Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm (clamped with 1mm thick saddle) |
| 162 | OD57098/2026-2027:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 2x10 sqmm (clamped with 1mm thick saddle) |
| 163 | OD57102/2026-2027:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5 C X95 sqmm |
| 164 | OD56979/2026-2027:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5 C X185 sqmm |
| 165 | 90.12.9.3:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench63/50 mm or nearest size |
| 166 | 90.12.10.3:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size |
| 167 | OD57124/2026-2027:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 650/1100 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3 core 2.50 sq mm with factory made clamp |
| 168 | OD57126/2026-2027:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 650/1100 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 2.50 sq mm with factory made clamp |
| 169 | 9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) |
| 170 | 9.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm) |
| 171 | 9.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm) |
| 172 | 9.2.24:Supplying and making outdoor end termination with cast resin compound including aluminiumlugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 185 sq. mm |
| 173 | 9.1.25:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm) |
| 174 | 9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) |
| 175 | 9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 176 | 9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 177 | OD57132/2026-2027:Providing and drawing 2.65 mm (12 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 178 | OD57133/2026-2027:Providing and drawing 3.15 mm (10 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 179 | 5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 180 | 90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) |
| 181 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 182 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) |
| 183 | 4.1.4:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 184 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 185 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 186 | OD370721/2025-2026:Supply and providing 25x3mm brass bolt |
| 187 | OD370722/2025-2026:Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate |
| 188 | OD370723/2025-2026:Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system |
| 189 | 90.16.3.3:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 6 mm GI strip |
| 190 | 90.16.4.3:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 6 mm GI strip |
| 191 | OD6103/2026-2027:Supply and providing the following sizes of strips in ordinary soil below ground level including excavation. as required .25 x 6 mm GI strip |
| 192 | OD370724/2025-2026:Supply and providing 25x6mm brass bolt |
| 193 | OD327549/2025-2026:Supply and providing 2.50 mm thick, 11 kV, Synthetic elastromeric fire retardant insulating sheet to withstand 3.3 KV dielectric strength conforming to IS |
| 194 | OD327558/2025-2026:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required. |
| 195 | OD327550/2025-2026:Supply and providing 4/5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required. |
| 196 | OD57138/2026-2027:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & shall conform to relevant IS .Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 197 | 90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. |
| 198 | 90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet |
| 199 | 90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required. |
| 200 | 90.14.7:Supply and providing copper earth bus in the panel board |
| 201 | 90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC) |
| 202 | OD370745/2025-2026:Supply, conveyance and fixing 125A, 415V 50/60Hz 4Pole Automatic Transfer Switch (ATS) with Priority source selection with Power supply module to the controller and wiring kit for auto operation (Provosion for DG start and stop auto operation) in existing panel board including giving connection (L&K, or equivalent make) |
| 203 | 90.14.10.14:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC |
| 204 | 90.14.10.12:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC |
| 205 | 90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL |
| 206 | 90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A |
| 207 | 2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N |
| 208 | OD371419/2025-2026:Supply and fixing 200/5 A, 10 VA, accuracy class 0.5, Resin Cast Metering CT including connection in existing Panel board. |
| 209 | OD371420/2025-2026:Supply and fixing 150/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT, Resin Cast Metering CT including connection in existing Panel board. |
| 210 | OD370760/2025-2026:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipments including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 1.5Sqmm single run |
| 211 | OD371538/2025-2026:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipments including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 4.00Sqmm single run |
| 212 | OD371539/2025-2026:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipments including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 6.00Sqmm single run |
| 213 | OD370761/2025-2026:Supply & fixing the LED indicators for all voltage ranges Red, Green, Black, Yellow, Orange colours LED indicator, AC/DC, 22.5 mm cut out dia and giving connection etc as required |
| 214 | OD58333/2026-2027:Supply and fixing Blue colour LED indicator, AC/DC, 22.5 mm cut out dia and giving connection etc as required |
| 215 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 216 | 2.10.5:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole and neutral |
| 217 | OD370762/2025-2026:Supplying and fixing 125A, 2 Way neutral links mounted on DMC/SMC base with connections,in existing meter board |
| 218 | OD371543/2025-2026:Supplying and fixing 63 A, 2 Way neutral links mounted on DMC/SMC base with connections,in existing meter board |
| 219 | OD6072/2026-2027:Supply and fixing 32A 2Way neutral link with connection in existing meter board |
| 220 | OD370763/2025-2026:Supplying and fixing 125A HRC Fuse with HRC Fuse link with connections, in existing meterboard |
| 221 | OD371547/2025-2026:Supplying and fixing 63, HRC Fuse with HRC Fuse link with connections, in existing meterboard |
| 222 | OD6089/2026-2027:Supply and fixing 32A Cutout Fuse with 16/20/25A HRC Link connection in existing meter board |
| 223 | OD370764/2025-2026:Supplying and fixing 2 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing Panel board complete with connections, testing and commissioning etc. as required.Single pole |
| 224 | OD6453/2026-2027:Supply and fixing 4 way rectangular type SMC pole mounting junction box having IP55 with hinged door having inside dimensions 250x200x105mm for terminal box fixing on wall using suitable screws and plugs etc as required for test joint junction (Syntex GSJB2520) or equivalent make |
| 225 | 2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 226 | OD370843/2025-2026:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision. |
| 227 | OD370726/2025-2026:Supply ,Conveyance Installation ,Testing and Commissioning of 82.5 KVA DG set(CPCB 4+) as per the technical details given below. Engine. a. Make of Engine - As specified in accepted list of material. b. Type of Engine-Diesel Engine. c .No. of cylinder- Suitable to develop the required BHP as per manufacturer's standards. Digital Multi function meter with accuracy class 1 to read parameters such as KW,KVA, PF, voltage, Current Frequency etc: c) Digital type single function KWH meter with accuracy class 1, d) Method of Cooling; Liquid cooled with radiator. e) Aspiration -Turbo charged, charge after cooled. f) Design - Suitable for generating set operating. g) Output- As per manufactures standards. 2. Standard accessories with Diesel Engine. a) Fly wheel to suit flexible coupling b) Close Coupling c) Air cleaner d)Radiator with fan provided with fan guard. e) Fuel Pump f) Electronic Governor g) Fuel filter h) Exhaust silencer i) Exhaust Muffler j) Lubricating oil filter. k) Battery Charger/Generator 3.Engine Instrument Panel with the following items a) Starting switch with key or button. b) Lubricating oil pressure gauge. c) Water temperature gauge. d) RPM Indicator with hour meter. e) Battery charging Ammeter. 4. Safety Controls for Engine. a) Trip for low lubricating oil pressure. b) Trip for high water temperature. 5.Fuel pipe: Oil resistance flexible hoses of 20mm dia or nearest size MS pipe as per manufacturers standard, 6 Brush less Alternator a) Make : as specified in accepted list of materials b) Type - Self exited and self-regulated, brush less c) Capacity; 82kVA/ 66 K W @ 0.8PF d) System of Voltage - 3 phase, 415 V, 4 wire system. e) Speed - 1500 rpm f) Voltage regulation band - +/-2.5% of rated voltage g) Frequency - 50 Hz h) Insulation - Class -F/H .The Alternator should confirm to IS 4722. Operation and service manual shall be provided.7.Fuel Tank Suitable size built in type integrated with the acoustic enclosure. Fuel connection shall be done as per standards 7. Battery. Suitable size built in type integrated battery with leads and terminals of appropriate AH capacity as per Manufactures requirement. 9. The DG shall be supplied along with specially designed company fabricated (to be fabricated in the same company from where the DG is delivered.)acoustic enclosure to meet the stingent MOEF/CPCB norms of 75 dB A @1m 75% load under free field condition 10. The standard Electric control panel integrated with acoustic enclosure comprising of the following. a) 160A,4Pole MCCB b) Digital Multi function meter with accuracy class 1 to read parameters such as KW,KVA, PF, voltage, Current Frequency etc: c) Digital type single function KWH meter with accuracy class 1, d) external source power (230V AC) battery charger e) Provision for connecting Auto start (AMF/ATS connection) 10.Exhaust Piping, Exhaust Piping shall be vent to the top of the nearest tallest building if required. If the pipe cannot be clamped/fixed to the building or any other structure of permanent nature necessary fabricated structures using channel section or angle iron sections of adequate mechanical strength, duly painted with 2 coats of Heat retardant aluminum paint shall be provided for the support of the exhaust pipe. (Additional piping will be measured excluding the standard length of pipe supplied by the manufacturer.) including arranging load test at site or company, assembly unit with presents of department staff. The DG set should be provided with 5-year comprehensive maintenance inclusive of all Services, periodic maintenance as prescribed by the OEM including all consumable items like Engine Oil, Oil Filter, Air Filter, Coolant etc. |
| 228 | OD54102/2026-2027:Supply, conveyance and filling of good grade Diesel fuel. |
| 229 | OD81916/2026-2027:cladding for 100mm dia MS exhaust pipe using 50mm thick glass wool /mineral wool /rock wool density not less than 120Kg/m3 and aluminium cladding (0.6mm thick). |
| 230 | OD81917/2026-2027:Cladding for 80mm dia MS exhaust pipe using 50mm thick glass wool /mineral wool /rock wool density not less than 120Kg/m3 and aluminium cladding (0.6mm thick). |
| 231 | OD82395/2026-2027:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of Heat resistant paints of required shades complete as required:100mm dia |
| 232 | OD82400/2026-2027:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of Heat resistant paints of required shades complete as required 80mm dia |
| 233 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). |
| 234 | OD371595/2025-2026:Supply, conveyance, installation, testing and commissioning of 3 phase 415V, 3 HP/2.2KW, Open well submersible motor pump set with a discharge rate of 10.1/3.3 LPS against the head range of 22/50 m with required accessories-Aquatex, V-guard, Kirloskar or equivalent make |
| 235 | 90.14.28.14:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,TPMCB for three phase 5 to 7.5HP submersible motor pumps (DOL) |
| 236 | 90.14.24.1:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.1 KVAr, 3 phase, 440 V, delta connected Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors. |
| 237 | 2.17:Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 238 | 90.6.6.2:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.2.50 sq mm |
| 239 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 240 | OD371608/2025-2026:Supply and providing 50mm stainless steel Hose Collar with hose clip |
| 241 | OD124008/2026-2027:Supply and laying of 20mm or nearest size Nylon rope |
| 242 | OD371610/2025-2026:Supply and providing 50 mm dia Brass iron Non return Valve( Heavy duty) |
| 243 | OD371611/2025-2026:Supply and providing 50mm G.I.Barrel nipple |
| 244 | OD123994/2026-2027:Supply and providing 50mm full way wheel valve |
| 245 | OD123964/2026-2027:Supply and providing 50mm dia PVC adaptor -Male |
| 246 | OD123965/2026-2027:Supply and providing 50mm dia 6kg/cm2 HDPE pipe (ISI marked) |
| 247 | OD327553/2025-2026: Copying charges for additional copies per A3 sheet |
| 248 | OD123903/2026-2027:Charges for preparation of Electrical/fire Drawing per A3 sheet first copy |
| 249 | OD327557/2025-2026:Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required- 2.50 cm, 4 cm or 5 cm height |
| 250 | Fire Protection System(Electrical work) |
| 251 | OD327561/2025-2026:Supply,erection,testing and commissioning of Automatic Motor control panel for the electric driven terrace pump, with 10/12.5 HP DOL starters, 40 A ,4 pole MCB isolator and contactors to ensure auto and manual operation shall rated for motor HP. The panel shall include necessary indicating lamps for the RYB phases, ammeters and volt meter with selector switch etc. The panel shall have Auto/Manual Selector switch. The panel shall be powder red colour and shall have provision for wall mounting with all accessories as required complete. |
| 252 | 18.4.1:(a) Supplying, installation, testing and commissioning of electric driven900 lpm at 35m Head |
| 253 | OD82133/2026-2027:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp |
| 254 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 255 | OD58464/2026-2027:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 4x25 sqmm (clamped with 1mm thick saddle) |
| 256 | 9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 257 | OD58461/2026-2027:Providing and drawing 3.15 mm (10 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 258 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 259 | 18.8.1:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required.25mm |
| 260 | 18.8.3:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required.40mm |
| 261 | 18.8.4:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required.50mm |
| 262 | 18.8.5:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required.65mm |
| 263 | 18.8.6:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required.80 mm |
| 264 | 18.8.7:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required.100 mm |
| 265 | 18.21.1:Providing,fixing, testing and commissioning of 15 mm dia quatzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler |
| 266 | 18.25.2:Supplying, installation, testing & commissioning of sprinkler flexiblepipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.1000 mm |
| 267 | 18.11.5:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:100 mm dia |
| 268 | 18.11.4:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:80 mm dia |
| 269 | OD9472/2026-2027:Supplying, fixing, testing and commissioning of 25mm Ball valve with bronze/gunmetal seat duly ISI marked complete with gaskets |
| 270 | 18.14.5:Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.100 mm dia |
| 271 | 18.17.1:Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a) 20 mm nominal Internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585b) 20 mm nominal internal dia gun metal globe valve &nozzlec) Drum and brackets for fixing the equipments on wall.d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m |
| 272 | OD9495/2026-2027:Supply & Fixing of Hose cabinet made of M.S Sheet with full front glass door and locking arrangements suitable to accommodate 2 Nos 15 M long Hose pipes and 1 No Branch pipe. The cabinet shall be painted to scarlet red colour out side & Offwhite inside. |
| 273 | 18.16.2:Supplying and fixing 63 m dia,15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required: Stainless steel (Grade 304) |
| 274 | 18.18.2:Supplying and fixing 63 mm dia gun etal short metal branch pipe ith 20 mm nominal interanal diameter size nozzle conforming to IS 903 suitable for Instantaneous connection to Interconnect hose pipe coupling as required:Stainless steel (Grade 304) |
| 275 | 18.10.2:Supplying and fixing single headed external yard hydrant valve with one no: 63 mm dia instantaneous FM Gun metal or stainless steel coupling and cast iron wheel, ISI marked ISI marked conforming to IS 5290(Type A) with blank Gun metal or Stainless steel cap and chain as required:Single headed stainless steel |
| 276 | 18.9.2:Supplying and fixing single headed internal hydrant valve with instantaneous Gun metal or stainless steel coupling of 63mm dia with cast iron wheel ISI marked conforming to IS 5290(Type A) with blank Gun metal or Stainless steel cap and chain as required:Single headed stainless steel |
| 277 | 18.19.1:Supplying and fixing fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia M.S. Pipe connection conforming to IS 904 as required:2 way-100 mm dia M.S.Pipe |
| 278 | OD327565/2025-2026:Supplying, fixing, testing and commissioning of 25 mm air release valve with bronze/gunmetal seat duly ISI marked complete with gaskets |
| 279 | 18.22:Providing and fixing of pressure switch in MS pipeline including connection etc as required: |
| 280 | 16.8:Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required |
| 281 | OD327568/2025-2026:Supply & erection of Fire Escape rout in each floor having size 12" x 16" made of 3mm thick acrylic sheet with glass frame |
| 282 | OD327567/2025-2026:Supply & erection of Glow Sign Board made of 3mm thick PVC foam board for Assembly Point sign board 16" x 16" |
| 283 | OD327569/2025-2026:Supply & erection of Glow Sign Boardmade of 3mm thick PVC foam board for each floor 12" x 4" (appropriate places) |
| 284 | 17.1.2:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of smoke detector with built-in LED and mounting base complete with all connections etc. as required. |
| 285 | 17.1.1:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of heat detector operating at 54ºC / 57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. |
| 286 | 17.1.4:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 287 | 17.1.7:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 288 | OD9513/2026-2027:Supplying, installation, testing & commissioning of 10 Zone fire alarm control panel as per IS: 2189 with backlit LCD Display Main control and indication panel made out of 16 SGW MS sheet to accommodate the following items duly stove anameled painted in approved colour with louvers for ventilation?s locking arrangement including audio and visual indication for fire alarm and monitoring system including suitable size battery backup providing and fixing the following connections, interconnections etc. |
| 289 | 17.5.2:CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 290 | 90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid |
| 291 | 90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap |
| 292 | OD126250/2026-2027:Supplying and fixing a "draw out connection" of 100mm which allows fire brigade personnel to connect their hoses to the system's water supply, typically from a fire hydrant or landing valve with blank Gunmetal/Stainless Steel cap and chain as required |
| 293 | OD126251/2026-2027:Supplying , fixing, testing and commissioning of BALL TYPE Cast iron body Foot valve bronze/ Gun metal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS as required.100mm |
| 294 | OD9518/2026-2027:Supply and providing 4.5Kg CO2 fire extinguisher, filled with CO2 gas as per IS 15222, control discharge mechanism fitted with minimum 1.5 meter wire braided hose & flat horn with diffuser nozzle for dispersed discharge of CO2, discharge time 37 sec, average discharge is 95%, applicable on class B, C and electrcally started fire, external coating is of enamel spray painting, valve confirm to IS 3224 ISI marked, CO2 cylinder construction: hot spinning by seamless pipes & bearing ISI mark, body confirms to IS 7285 extinguishers to ISI marked. fire rating:89B |
| 295 | OD9519/2026-2027:Supply and fixing of 2 Kg Clean agent fire Extinguisher Modular type of following sizes suitable for below ceiling built in 1 piece with body and bottom. Mild steel body with pressure gauge refillable device and safety release device, Brass valve suitable for B and C classes of fire complete with charge of HFC 236FA/FE36(it is a blend of Hydro Fluoro carbon and organic detossificant essence P 26). The extinguisher shall have pressure gauge for indicationg inside pressure with heat sensitive glass bulb 68 degree with brass forged nozzle and sheet thickness shall not less than 2mm |
| 296 | OD9520/2026-2027:Supply and providing 4Kg ABC Fire Extinguisher cap filled with mono ammonium phosphate powder 50% confirms to IS 1409, stored pressure type, with pressure gauge, the discharge time 24 sec, controllable discharge mechanism, jet range 5 meters, average discharge is 90%, appliccable on A,B & C and electrically started fire, A rating-3A, B rating 21B, construction: deep drawn & co2 mig welded, EPDM rubber hose with both end aluminium clamped, internal coating-epoxy powder coating, external coating-pure polyster powder coating(UV resistant),brass forged valves with safety pin is of ss material, sheet metal thickness ISI approved. |
| 297 | OD327570/2025-2026:Charges towards the preparation of necessary plan and other related papers for submission to Fire authority for Initial /final NOC - First A2 Sheet |
| 298 | OD327563/2025-2026:charges for copying charges for additional copies per A2 sheet |
| 299 | Passenger Lifts(Electrical work) |
| 300 | OD371630/2025-2026:Supply, Installation, Testing and Commissioning of 20 passenger goods cum passenger machine room less gearless lift conforming to IS 17900 . 1. Type of Lift: 20 Passenger capacity, Gearless 2. Load / Persons : 1360 Kg. / 20 persons 3. Rated speed :1 M/Sec. 4. Travel: 12 Mtr (Approx.) 5. No. of floor and entrance served: 4 stops and openings 6. No. of floor served: Four floors 7. Method of control: Microprocessor based V3F with ARD system. 8. Size of lift well :3050 mm X 2000 mm 9. Car entrance: As per IS or as per Barrier free rule. 10. Leveling accuracy: As per IS 11. Car door opening: As per IS 12. Drive: Variable voltage variable frequency(V3F) 13. Operation: Simplex full selective collective control with ON/OFF switch 14. Construction of design and furnishing of car body work: Vandal proof Stainless steel (SS304, make: Tata/Jindal)finish cabinet with Scratch Proof Stainless steel door (sheet minimum thickness 1mm), Stainless steel mirror finish ceiling, Aluminum 3mm minimum thickness anti-skid flooring, fan with timer cut-off, push to talk, LED display, LED light, three side hand rails and floor announcement system. All buttons in car and all landings should have Braille sign. 15. Landing entrance: Automatic center/Telescopic opening Vandal proof stainless steel sliding door as per IS with provision for mechanical opening key for emergency with full length infra-red light curtains and half framed glass door(liminated toughened glass with a minimum thickness of 8mm ) 16. Call and position indicators: Up/down direction & position Dot Matrix LED indication shall be provided at all landings 17. Electric supply: 1) Light 230/50C/s single phase 2 wire system. 2) 415V 50C/s 3 phase 4 wire system. 18. Infrared door opening system: To be provided for entire length of the door 19. Automatic Rescue Device: Provide automatic rescue device with an electronic controller powered by maintenance free batteries with capacity for minimum four successive rescue operation at full load. The rescue operation should act within 10 seconds of power failure 20. Regulation :350V 450V (SMPS based) 21. Indication in the car: a) Car position b) Call indicator c) Door close/open push button d) Emergency stop button e) Flush mounted switch for fan and light f) Nonstop button g) Battery operated emergency lamp with rechargeable batteries. h) Battery operated alarm bell i) Intercom wiring with one master unit with two slaves j) Fireman's switch at main lobby i) Auto attendant control (inside the car) 22. Winding handle Manual winding handle for use in emergency. 23. Safeties a) Bidirectional Over speed governor(OSG), Progressive type safety gear b) Buffers c) Motor over load and under voltage protection d) Phase reversal protection e) Other safeties as per IS f) Single phase preventer g) Final limit switch 24. Leveling Automatic leveling at all landing as per IS. 25. Control panel: Control panel will be dust and vermin proof of sheet metal enclosure 26. Announcement System: To provide lift announcement system 27. Tests: At site test as per IS to be carried out and approval from Electrical Inspectorate before Handing over. 28. Scope of work:- a) Supply of lift materials b)Minor civil works such as removal of temporary brick work in the lift entrance without affecting the building structure, finishing/ altering civil works in lift entrance/ pit by providing brick work & plastering if necessary including minor civil works such as construction of buffer block in the pit machine foundation in the machine room, necessary core cutting , cutting pockets and grounding brackets for the guide rails, grouting boxes for control units, correction of wall opening in the front side in plastering c) Scaffolding d) Door frames e) Supporting steel (machine and rope ending point support should extended to existing well wall side using suitable I/C section channels as per the direction of department staff) f) Temporary electric supply for installation of lift. Electric supply for testing and commissioning of lift is to be arranged by the firm on their own account. g) Intercom facilities with one master and two slaves h) Battery operated alarm i) Obtaining Scheme approval as well as energization Certificate from the electrical Inspectorate including preparation of necessary drawing for the same. inclusive of necessary fee to the Inspectorate and first year insurance as per new lift rule by the firm for which no refund will be made from the department including taking insurance for one year as per new lift rule. j) Supply of booklets with complete details of maintenance schedule and control diagram. k) Giving training to department staff for attending trouble shooting 28.Unintentional car movement protection 29. Guarantee: Company shall carry out free maintenance and service during warranty period which also includes a) Cleaning lift equipment b) Lubrication of all moving parts c) Replacing of lubricating oil when required d) Checking and adjusting contacts e) Replacing fusible item alarm etc. f) Recharging batteries in case of drain/ renewing batteries g ) Replacing /rewinding of all defective parts of the lift including motors and V3F unit. |
| 301 | Air Conditioning(Electrical work) |
| 302 | OD38389/2026-2027:Supply, installation, testing and commissioning of 2.5 TR ceiling mounted 4-way cassette type 3star inverter air conditioner, suitable for 1phase, 50 Hz AC supply, with anti-corrosive copper condenser unit each comprising an outdoor unit consisting of Inverter Rotary compressor suitable for R-32 refrigerant , air cooled condensing unit, Condenser fan etc. with outer casing and indoor ceiling mounting type , fan coil unit, consisting of centrifugal fans, fan motor, cooling coil, filter, control and power panel with remote control with hand set etc. both inter connected with using existing copper refrigerant pipe , power and control cable and drain pipe as given and leak testing , and commissioning after full charge of refrigerant gas, the outdoor unit shall be installed on existing factory made frame fixed on wall with using suitable anger bolt or nut and bolt the indoor unit shall be mounting on the ceiling with all accessories , etc as required .as per OEM standards, wireless remotes, necessary ribbed rubber pads etc. complete as required at site . |
| 303 | OD38368/2026-2027:Supply, installation, testing and commissioning of 2 TR ceiling mounted 4-way cassette type 3star inverter air conditioner, suitable for 1phase, 50 Hz AC supply, with anti-corrosive copper condenser unit each comprising an outdoor unit consisting of Inverter Rotary compressor suitable for R-32 refrigerant , air cooled condensing unit, Condenser fan etc. with outer casing and indoor ceiling mounting type , fan coil unit, consisting of centrifugal fans, fan motor, cooling coil, filter, control and power panel with remote control with hand set etc. both inter connected with using existing copper refrigerant pipe , power and control cable and drain pipe as given and leak testing , and commissioning after full charge of refrigerant gas, the outdoor unit shall be installed on existing factory made frame fixed on wall with using suitable anger bolt or nut and bolt the indoor unit shall be mounting on the ceiling with all accessories , etc as required .as per OEM standards, wireless remotes, necessary ribbed rubber pads etc. complete as required at site . |
| 304 | OD58568/2026-2027:Supply , Installation, Testing and Commissioning of 5 star rated 1.5TR Air Cooled Hi Wall Invertor split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), Copper evoporator coil and condensing coil , surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature) with comprehensive maintenance contract up to the end of 36 month form date of commissioning including periodical services, gas topping etc. |
| 305 | OD371334/2025-2026:Supply and installation of out door unit stand for single/three phase wall mounting split AC unit as required- |
| 306 | OD38750/2026-2027:Supply and Fixing of 4 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and output range of 210 - 240V (V Guard or equivalant make |
| 307 | OD371332/2025-2026:Supply and fixing of 25mm (10kg/sq.cm) PVC drain pipe along with all required accessories in surface/ recess including cutting the wall and making good the damages etc. as required- |
| 308 | OD371331/2025-2026:Supply and providing following size soft drawn Copper pipe for extending pipe between out door and indoor units including insulating pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc. 3/8"(9.52mm) and 5/8"(15.8mm) 22 gauge- |
| 309 | OD58581/2026-2027:Supply and providing following size soft drawn Copper pipe for extending pipe between out door and indoor units including insulating pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc. 1/4"(6.35mm) and 1/2"(12.7mm) 22 gauge--, |
| 310 | OD81887/2026-2027:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm |
| 311 | Ongrid Solar Plant(Electrical work) |
| 312 | OD9609/2026-2027:Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Monoperc half cut solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required. a) High Energy Efficiency Solar Photovoltaic Module of capacity 540Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 21% at STC with temperature coefficient of Pmax better than -0.30% per °C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 °C and +85 °C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate. b)Power Conditioning Unit (PCU) of 350- 800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 °C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminum/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided. Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Metal Oxide Varistors (MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc. f) Lightning, surge voltage protection, earthing protection and grid islanding. g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required. h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection interconnection, etc. as required. For the warranty of the solar grid-tie inverter and panels, the contractor shall submit a letter of warranty confirmation from the respective brands, mentioning the serial numbers of the specific products installed at the site. |
| 313 | OD81805/2026-2027:Supply and providing reverse power relay having System voltage of 110/415V ,aux supply voltage of 88-264V AC/DC and CT Secondary current of 5A and proper connection as required proper connection as required |
| 314 | OD124156/2026-2027:Supply and fixing 3Phase 4Wire , 415V Direct reading 10-60A Net Energy Meter with an accuracy class of 1.0 as per KSEB standard and giving connection etc. |
| 315 | High mast yard lighting(Electrical work) |
| 316 | 90.15.2.3:Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12 Meters |
| 317 | OD80230/2026-2027:\\"Supply, installation, testing and commissioning of 18000 lumen LED Flood light, directly on the existing pole, efficacy >=120 Lm/watt, IP 66 flood light fitting with die-cast aluminium housing, polycarbonate cover complete with THD 0.95, RoHS compliant, duly wired up for use on 230 V AC supply, IK >=7, with internal surge protection 4k above. Chip make Cree/Osram/lumilled/Nichea/Bridgelux.\\" |
| 318 | OD54122/2026-2027:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & shall conform to relevant IS .Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 319 | 90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet |
| 320 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 321 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 322 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 323 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 324 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 325 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 326 | OD35264/2026-2027:Supplying and fixing following rating, four pole, Centre off MCB Change over in the existing MCB DB complete with connections, testing and commissioning etc. as required.32 amps |
| 327 | OD35034/2026-2027:Supplying and fixing following rating, double pole, 240 volts, MCB type center OFF COS in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps |
| 328 | OD35037/2026-2027:Supplying and fixing 240/415 volts, 30A AC1/12A AC3 Power contactor 3Pole with 240V operating voltage in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 329 | OD35048/2026-2027:Supplying and fixing 24Hr Analog Timer switch with NO/NC operating voltage 230V complete with connections, testing and commissioning etc. as required. |
| 330 | OD80194/2026-2027:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required.1.5sq mm wire single run |
| 331 | OD80198/2026-2027:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required.4.00sq mm wire single run |
| 332 | 2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 333 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 334 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 335 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 336 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). |
| 337 | OD35071/2026-2027:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 338 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 339 | OD59141/2026-2027:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 2x4 sqmm |
| 340 | OD59142/2026-2027:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 341 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 342 | OD59146/2026-2027:Providing and drawing 2.65 mm (12 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 343 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) |
| 344 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 345 | OD39835/2026-2027:Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate |
| 346 | OD39836/2026-2027:Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system |
| 347 | OD39837/2026-2027:Supply and providing 25x6mm brass bolt |
| 348 | LAN(Electronics Work) |
| 349 | OD319843/2025-2026:SITC of 24-Port Gigabit PoE +Smart Switch with 2 SFP ports and cloud management system with 250 Watts minimum power budget and minimum specification of - 24 port Gigabit with PoE+ and 2 dedicated Gigabit SFP fiber uplink ports, layer 2 features, Non blocking switching with 52 Gbps, IPv6 management: IPv6 Qos, IPv6 ACL, IPv6 Multicast and static and dynamic IPv6 address assignment etc. or better specifications. Make: TP-Link/Netgear/D-Link |
| 350 | OD319853/2025-2026:SITC of fully loaded 24 port cat-6 PatchPanels conforming to relevant standards for interconnecting of servers and nodes.Preferred Make: AMP/Molex. |
| 351 | OD319854/2025-2026:"Supply and fixing Floor Mount 9U Rack for switches for NVR including , AC Distribution box(x1) and hardware mounting kit Recommended: Legrand/Rittal . " |
| 352 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 353 | OD319859/2025-2026:Supply and Fixing CAT 6 RJ 45 modular Keystone jack in the existing front plates and giving necessary connections as required (RoHS)Make: AMP/Molex |
| 354 | OD319861/2025-2026:SITC of CAT-6/Class E, 2 meter Patch code confroming to TIA/EIA-568-B.1-1, IEX 60603-7-4. For interconnecting IO and Device. Make: AMP/Molex/Commscope |
| 355 | OD319862/2025-2026:SITC of CAT-6/Class E, 1 meter Patch code confroming to TIA/EIA-568-B.1-1, IEX 60603-7-4. For interconnecting IO and Device. Make: AMP/Molex/Commscope |
| 356 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 357 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 358 | 1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 359 | OD319913/2025-2026:SITC of Dual Band PoE Access point/Router, 802.11ac, 1 or 2 RJ 45 ports, integrated 802.3af power over ethernet (PoE) support: 5 GHz band(4*4 MIMO) with 1.733Gbps throughput rate and 2.4 GHz band(2*2 MIMO) with 300Mbps throughput rate. Recommended Make: Gradstreem/ Cisco/HP |
| 360 | OD319923/2025-2026:Supply of 1000 VA UPS having minimum backup time of 30minutes, with 12V/7Ah X 2 battery inside, input voltage range of 220-240V, minimum three output sockets, LED indicators, ergonomic buttons, overload and surge protection, minimum 2 years warranty.Recommended: APC/Emerson/Numeric |
| 361 | CCTV System(Electronics Work) |
| 362 | OD319941/2025-2026:Supply and installation of project series Network Video Recorder, support 16 Channel, Should support Resolution:- greater than equal to 12 MP IP Camera, Network Bandwidth incoming 320 Mbps and outgoing 320 Mbps for access, support for H.265+/H.265/H.264 encoding format streaming access and decoding output, , Recording play back quality: 16 ch play back simultaneously, Recording resolution up to 12MP, Recording mode: support manual, Auto, Motion detection, Alarm, trigger record mode, Operation way: Mouse, local Login: Username and password, Recording storage: Local HDD, network, Video output: HDMI/VGA/TV, , Support min. 4 SATA HDDs , Each port supports min. 12TB HDD,Support dual Gigabit Ethernet ports,Supports 2 HDMI outputs with a maximum of 4K HD output,Alarm Input/out:16 in /1 out ,Audio:1 in / 1 out ,Supports intelligent analytics such as facial recognition, human detection, vehicle detection,Licence plate recognition,perimeter intrusion, and line crossing statistics , product must comply with NDAA complaince, Certification: BIS,CE,FCC,ROHS ,ISO 9001:20015 ,Replacement/Repair warranty for 24 months or morePreferred make: Honeywell/ Bosch/ Axis/Pelco. |
| 363 | OD319958/2025-2026:SITC of 16-Port Gigabit PoE Switch with 2 SFP port, PoE Budget Port 1-2-90W, Port 3-16-30W, total-190W, 10BASE-T/100BASE-TX/1000BASE-T Interface options, Switching Capacity:32 Gbps, conforming to FCC Class A, CE Class A Emission, RoHS compliant. Recommended Make: HP/TP-Link/Netgear |
| 364 | OD319966/2025-2026:SITC of 8TB SATA 6Gb/s HDD for video recording inside the existing DVR. The drive should have 24x7 reliability, Reduced power consumption, Whisper quiet, Compatible, AF Technology etc. Recommended Make: WD Purple/Seagate/Thoshiba |
| 365 | OD319967/2025-2026:Supply and Installation of 5MP IP Varifocal Bullet Camera, Image Sensor: 1/2.7” 5MP Progressive scan Motorized Lens: 2.8 ~ 12mm, Resolution: 2880(H)x1620(V) or Higher IR Distance: 50 Mtr. Angle of View: Horizontal: 107-34°, Vertical: 55-19°, Diagonal: 134-38°, Min illumination 0.004lux,Video Compression: H.265+; H.265; H.264+; H.264; H.264B; MJPEG ,Video Streaming: Mainstream 30fps, 5MP(2880x1620), 4MP(2592x1520) 3MP(2304x1296),1080P(1920x1080)720P(1280x720), Substeam @30fps 720P(1280x720),VGA(640x480),QVGA(320x240), Third stream @30fps VGA(640x480), QVGA(320x240); Motion Detection: 4 zone, Rectangle ; Major Protocols should include most of the following TCP/IP,HTTP,DHCP,DNS,DDNS,RTP/RTSP, SMTP, NTP, UPnP, SNMP,HTTPS,FTP, ONVIF (Profile S/Profile G/Profile T); CGI; Event Trigger: Motion detection, Video tampering, Scene changing, Network disconnection, IP address conflict, Smart Detection: Face Recognition, Human& Vehicle Detection, Perimeter Intrusion Detection, Line Crossing Detection, Cross Counting, Stationary Object Detection, Heat Map, Crowd Density Detection, Queue Length Detection, Rare Sound Detection, Advance features: Starlight, WDR(120dB),Micro SD Card Slot up to 256GB, Alarm I/O-1/1, Audio I/O 1/1,Privacy Mask up to 8 level, ICR auto switch Power Source: 12V DC/PoE, Casing: Metal ,Weatherproof Standard: IP67 ;product must comply with NDAA compliance, Non Black Listed Declaration , Own Mac Address Declaration , Onvif Membership Declaration, Certification: BIS,CE,FCC,ROHS ,ISO 9001:2015 Replacement/Repair warranty for 24 months or more Preferred make: Honeywell/ Bosch/ Axis/ Pelco. |
| 366 | OD319971/2025-2026:SITC pf 5MP IP Bullet Camera with inbuilt mic Image Sensor: 1/2.7” 5MP Progressive scan Lens: 3.6mm fixed lens Resolution: 2592(H)×1944(V) or Higher IR Distance: 30 Mtr. Angle of View: Horizontal: 79°, Vertical: 56°, Diagonal: 106°,Min illumination 0.003lux @ F1.6(AGC ON),Video Compression: H.265+; H.265; H.264+; H.264; H.264B; MJPEG ,Video Streaming: Mainstream @30fps5MP(2592x1944),4MP(2592x1520),3MP(2304x1296),1080P(1920x1080), 960P(1280*960) ,Substeam @30fps 1080P(1920x1080),720P(1280x720),VGA(640x480), Third stream @30fps VGA(640x480), QVGA(320x240; Motion Detection: 8 Level, Rectangle ; Major Protocols should include most of the following TCP/IP,HTTP,DHCP,DNS,DDNS,RTP/RTSP, SMTP,NTP,UPnP,SNMP,HTTPS,FTP, ONVIF (Profile S/Profile G/Profile T); Smart Detection: Face Recognition,Human&Vehicle Detection,Perimeter Intrusion Detection,Line Crossing Detection, Cross Counting,Stationary Object Detection,Heat Map,Crowd Density Detection,Queue Length Detection, Rare Sound Detection, WDR(120dB),Micro SD Card Slot up to 256GB, Privacy Mask, ICR auto switch Power Source: 12V DC/PoE Casing: Metal ,Weatherproof Standard: IP67;product must comply with NDAA complaince,Non Black Listed Declaration , Own Mac Address Declaration , Onvif Membership Declaration, Certification: BIS,CE,FCC,ROHS ,ISO:9001;Replacement/Repair warranty for 3 Years or more Preferred make: Honeywell/ Bosch/ Axis/Pelco. |
| 367 | OD319973/2025-2026:SITC of CCTV Camera Box Waterproof IP65 and IP67. Elegant design with heavy duty ABS Enclosure for outdoor applications. Easy outside wall mounting options with 2.5mm thick ABS Enclosures. |
| 368 | OD319982/2025-2026:Supply and fixing Wall Mount 9U Rack for switches, NVR including , AC Distribution box(x1) and hardware mounting kit, cooling fan (x1), cable manager(x1) etc.Recommended: Legrand/Rittal /Netrack |
| 369 | OD319991/2025-2026:SITC of full HD 32" HD ready LED TV having, Resolution: HD Ready 1366 x 768 Pixels, Sound Output: 16 W, Refresh Rate: 50 Hz, Direct LED, 3 years OEM warranty.Recommended Model : Impex/Vu/TCL |
| 370 | OD319994/2025-2026:Supply and drawn HDMI cable to connect NVR to LED TV. |
| 371 | OD319998/2025-2026:Supply of 1000 VA UPS having minimum backup time of 30minutes, with 12V/7Ah X 2 battery inside, input voltage range of 220-240V, minimum three output sockets, LED indicators, ergonomic buttons, overload and surge protection, minimum 2 years warranty.Recommended: APC/Emerson/Numeric |
| 372 | OD320000/2025-2026:SITC of Warning sign boards-Polyethylene Palstic with statutory wand and signs. |
| 373 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 374 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 375 | 1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 09, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Sep 24, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 9 daysSep 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender