Tender For Civil Work Of Center Of Excellence For Dragon Fruit Mirzapur
Tender Value
3.46 Crore
Estimated cost
Bid Submission
14 Sep 2026
1 days left
EMD
7 Lakhs
Bank guarantee accepted
Document Fee
6164
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mirzapur → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Civil Work Of Center Of Excellence For Dragon Fruit Mirzapur
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. DSR- 2.8.1 |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil. From 0.00 mt to 1.50 mt. DSR-2.6.1 |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil. 1.50mt to 3.0 mt. DSR- 2.6.1 +2.26.1 |
| 4 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. DSR- 2.25 (a) |
| 5 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. DSR- 2.27 |
| 6 | Providing and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment and creating a chemical barrier under and around the column pits, wall trenche basement excavation top surface if plinth filling junction of wall and floor along the external per meter of binding expension joints surrounding of pipes and conduit etc. Complete (Plinth area of building at ground floor only shall be measured as per I.S. 6313 part II 1981). Aldrine emulsificable concentrate of any other approved material such as Hepthachlor or Chlordance will be used. The rate of application of chemical emulsion shall be as follows: I. Treatment for masonry and foundation 5 liters/sqm., II. Back fill in immediate contact with foundation 7.5 liters/sqm., III. Treatment of top surface of plinth filling 5 liters/sqm., IV. Treatment juction of soil along external per meter building 7.50 liters/sqm., V. Treatment of soil under apron along external perimeter 5 liters/sqm. as per PWD Deoria SOR, Page no. 17, New Item SI.No. 1 |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-lll) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) DSR-4.1.6 |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) DSR-4.1.3 |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) DSR-4.1.8 |
| 10 | Providing and laying in position cement concrete of 1:5:10 (1 cement : 5 coarse sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level . DSR- 4.1.10 |
| 11 | Brick work with common burnt clay (non modular) bricks of class -150 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) DSR- 6.1.1 |
| 12 | Brick work with common burnt clay (non modular) bricks of class -150 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) DSR- 6.1.2 |
| 13 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:All works upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum. DSR-5.33.1.1 |
| 14 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works above Plinth Lvl. Concrete of M25 grade with minimum cement content of 330 kg /cum. DSR-5.33.2.1 |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR- 5.22.6 |
| 16 | Add for using extra cement in the items of design mix over and above the specified cement content therein. DSR- 5.35 |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Foundations, footings, bases of columns etc for mass concrete._DSR-5.9.1 |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Suspended floors, roofs, landings, balconies and access platform_DSR-5.9.3 |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Lintels, beams, plinth beams, girders, bressumers and cantilevers._DSR-5.9.5 |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Columns,Pillars, Piers, Abutments, Posts and Struts._DSR-5.9.6 |
| 21 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. DSR-4.13 |
| 22 | Brick work with common burnt clay bricks of Class-150 in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:4 (1 cement : 4 coarse sand ) (Half Brick Wall) DSR-6.13.2 |
| 23 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand)_DSR-6.4.1 |
| 24 | Brick work with common burnt clay bricks of Class-150 in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 ( 1 cement : 6 coarse sand ) DSR- 6.4.2 |
| 25 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B- Fixing with adjustable lugs with split end tail to each jamb. DSR-10.14.1.1 |
| 26 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. DSR- 9.48.1 |
| 27 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in- harge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (70 mm & above) x (40 mm & above) & both glazed and fly screen sash (256 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre). DSR- 9.147.A4.1 |
| 28 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary. Extra for cutting rebate in flush door shutters. DSR- 9.20.1 |
| 29 | Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory, all complete with 4.0 mm thick glass panes. DSR-10.30.1 |
| 30 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. DSR-10.31 |
| 31 | Steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. In grantings, frames, guard bar, ladder, railing, brackets, gates and similar works. DSR-10.25.2 |
| 32 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. DSR-13.10 |
| 33 | 12 mm cement plaster in single coat on rough side of single or half brick wall finished with a floating coat of neat cement. (1) 1 cement : 3 Coarse sand. DSR-13.9.1 |
| 34 | 12 mm thick cement plaster of mix 1:6 ( 1 cement & 6 course sand ) DSR- 13.4.2 |
| 35 | 15 mm thick cement plaster of mix 1:6 ( 1 cement & 6 course sand ) DSR-13.5.2 |
| 36 | 15 mm thick cement plaster of mix 1:4 ( 1 cement & 4 coarse sand ) DSR-13.5.1 |
| 37 | Making Grooves cutting 10 to 12 mm wide and 8 mm deep a in plaster. DSR- 5.30 |
| 38 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone ) finished with floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. 40 mm thick floor 20 mm nominal size stone aggregate. DSR-11.3.1 |
| 39 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (25 mm thick). DSR-11.26.1 |
| 40 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing omplete. DSR-11.27 |
| 41 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. DSR- 11.41.2 |
| 42 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to 1.8. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc complete. Size of Tile 600x600 mm. DSR- 11.46.2 |
| 43 | Providing and fixing 18 mm thick Granite (gang saw cut) mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red. (Slab area above 0.50 Sq.M.) DSR- 8.2.2.2 |
| 44 | Providing and laying Ceramic glazed floor tiles of size 300 x 300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. DSR-11.37 |
| 45 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to 1S: 16622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. DSR- 8.31 |
| 46 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement DSR-11.20.1 |
| 47 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plasterd wall surface even and smooth surface. DSR-13.80 |
| 48 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. DSR -13.62.1 |
| 49 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. DSR-13.41.1 |
| 50 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) DSR -13.47.1 |
| 51 | White washing with lime to give an even shade : Old work (two or more coats)_DSR-13.87.1 |
| 52 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc.,by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.This layer will be allowed to air cure for 4 hours. (b) Second layer of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonary with polymer mixed slurry. DSR-22.5 |
| 53 | Supply & filling of Cinder in sunken portion of building including breaking into required sizes including supply of all material , labour, T&P required for proper completion of work. As per PWD Jhansi- Chap-11, New Item-3 |
| 54 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: With average thickness of 120 mm and minimum thickness at khurra as 65 mm. DSR -22.7.1 |
| 55 | Providing & fixing oxidized M.S. sliding door bolts ISI marked with nuts and screws etc complete (300mm x 16mm). DSR-9.62.1 |
| 56 | Providing & fixing oxidized M.S. tower bolts ISI marked with nuts and screws etc complete (250mm x 10mm). DSR-9.63.1 |
| 57 | Providing & fixing oxidized M.S. Door Handle ISI marked with nuts and screws etc complete (125mm). DSR-9.66.1 |
| 58 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter. (Weep Holes)_DSR-12.41.1 |
| 59 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter. DSR- 12.41.2 |
| 60 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110 mm bend. DSR-12.42.5.2 |
| 61 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm. DSR-12.43.2 |
| 62 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. DSR-12.22 |
| 63 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. DSR-10.16.1 |
| 64 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m². DSR-12.1.1 |
| 65 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) DSR- 10.28 |
| 66 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately. Casement door single panel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides. Using R3 series with frame (55 mm & above) x (50mm & above) & sash (55 mm & above) x (85mm & above) (Height upto 2.5 meter). DSR-9.147.F1.1 |
| 67 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. DSR- 9.121 |
| 68 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. DSR- 9.122.1 |
| 69 | Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. DSR-12.54.2 |
| 70 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineerin-charge. DSR-23.6 |
| 71 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade. DSR-16.70.2 |
| 72 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of E-i-c. With material conforming to Grade-II (Size range 53 mm to 0.075 mm) having CBR Value-25. DSR- 16.78.2 |
| 73 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. DSR- 16.79 |
| 74 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. DSR-16.91.2 |
| 75 | Supply & Laying of 40 mm gauge over burnt brick ballast including all materials, labour and T&P etc. for proper completion of the work. DSR-0287 |
| 76 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (a) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests_DSR-17.1.1 |
| 77 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid _DSR-17.2.1 |
| 78 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550 x 400 mm with single 15 mm C.P. brass pillar tap._DSR-17.7.4 |
| 79 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board 510x1040 mm bowl depth 250 mm_DSR-17.10.1.1 |
| 80 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe 32mm dia_DSR-17.28.1.1 |
| 81 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe 40mm dia_DSR-17.28.1.2 |
| 82 | Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements. Weighing not less than 106 gms. _DSR-18.65 |
| 83 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge._DSR-17.16a |
| 84 | Providing, fixing, jointing and testing in position of ISI marked PVC pipes for soil, waste, and vent including all neccessary specials and fittings i.e. bends, tees, junctions (with or without doors), reducers, WC connectors, couplers, cowels, clamps, hangers, rubber rings, clean outs etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc. inside duct / suspended from floor under false ceiling for proper completion of the work. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) (Pipe support : Intellotech / Easyflex / Chilly) The Pipes will be supported by either rubber lined G.I. U strap clamps on 50x50x5 mm MS slotted angle duly painted (for a group of pipes) or G.I. rubber lined split clamp (for independent pipes). The The cost will include all support arrangements. The work includes cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site.110mm dia_Ch-23 Item-43, Kannauj |
| 85 | Providing, fixing, jointing and testing in position of ISI marked PVC pipes for soil, waste, and vent including all neccessary specials and fittings i.e. bends, tees, junctions (with or without doors), reducers, WC connectors, couplers, cowels, clamps, hangers, rubber rings, clean outs etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc. inside duct / suspended from floor under false ceiling for proper completion of the work. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) (Pipe support : Intellotech / Easyflex / Chilly) The Pipes will be supported by either rubber lined G.I. U strap clamps on 50x50x5 mm MS slotted angle duly painted (for a group of pipes) or G.I. rubber lined split clamp (for independent pipes). The The cost will include all support arrangements. The work includes cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 75mm dia_Ch-23 Item-43, Kannauj |
| 86 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work) Exposed on wall 25mm dia nominal dia pipes_DSR-18.7.3 |
| 87 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work) Exposed on wall 32mm dia nominal dia pipes_DSR-18.7.4 |
| 88 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work) Exposed on wall 40mm dia nominal dia pipes_DSR-18.7.5 |
| 89 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. 15mm dia nominal dia pipes_DSR-18.8.1 |
| 90 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. 20mm dia nominal dia pipes_DSR-18.8.2 |
| 91 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 15mm nominal bore_DSR-18.21.2.1 |
| 92 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 15mm nominal bore_DSR-18.49.1 |
| 93 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore_DSR-18.50.1 |
| 94 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931. 15mm nominal bore_DSR-18.53.1 |
| 95 | Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore_DSR-18.17.1 |
| 96 | Providing and fixing gun metal gate valve with wheel of approved quality. 32mm dia nominal bore_DSR-18.17.2 |
| 97 | Providing and fixing gun metal gate valve with wheel of approved quality. 40mm dia nominal bore_DSR-18.17.3 |
| 98 | Providing and fixing brass stop cock of approved quality. 15 mm nominal bore_DSR-18.16.1 |
| 99 | Providing and fixing brass stop cock of approved quality. 20 mm nominal bore_DSR-18.16.2 |
| 100 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes 80mm to 300mm diameter._DSR-2.10.1.2 |
| 101 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 100mm diameter_DSR-19.1.1 |
| 102 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150mm diameter_DSR-19.1.2 |
| 103 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 100mm diameter S.W. Pipe_DSR-19.2.1 |
| 104 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 150mm diameter S.W. Pipe_DSR-19.2.2 |
| 105 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of .class designation 7.5_DSR-18.33.1 |
| 106 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 For Sewer Line_DSR-19.7.1.1 |
| 107 | Providing and fixing soil, waste and vent pipes : 75mm diameter : Centrifugally cast (spun) iron socketed pipe as per IS: 3989. _DSR-17.35.2.2 |
| 108 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar)_DSR-19.15.1 |
| 109 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 450 mm internal diameter_DSR-19.19.1.3 |
| 110 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 500 mm internal diameter_DSR-19.19.2.2 |
| 111 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks Class-150 _DSR-19.32.1 |
| 112 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries equired for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Drilling of 300mm dia bore hole manually._DSR-23.2.1.1 |
| 113 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia_DSR-23.4.2 |
| 114 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge._DSR-23.8 |
| 115 | Providing and laying Non pressure NP2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc. complete. 150 mm. dia. RCC Pipes_DSR-19.6.2 |
| 116 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe _DSR-19.3.2 |
| 117 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia_DSR-23.1.1.1 |
| 118 | Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia_DSR-23.3.1 |
| 119 | Supplying, assembling, lowering and fixing in vertical position in bore wellunplasticized PVC medium well screen (RMS) pipes with ribs, conformingto IS: 12818, including hire & labour charges, fittings & accessories etc.all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia_DSR-23.4.1 |
| 120 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge._DSR-23.7 |
| 121 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge._DSR-23.12 |
| 122 | Providing and fixing suitable size threaded mild steel cap or spot weldedplate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 100 mm nominal size dia_DSR-23.13.1 |
| 123 | Providing and fixing M.S. clamp of required dia to the top of casing/housingpipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts required size complete. 100 mm nominal size dia_DSR-23.14.1 |
| 124 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottomof pipe assembly of tubewell as per IS:2800 (part I). 100 mm nominal size dia_DSR-23.15.1 |
| 125 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 65 mm dia nominal bore_DSR-18.12.7 |
| 126 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C_DSR (E&M)-1.10.3 |
| 127 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required_DSR (E&M)-1.11 |
| 128 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire_DSR (E&M)-1.14.2 |
| 129 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire_DSR (E&M)-1.14.3 |
| 130 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire_DSR (E&M)-1.14.9 |
| 131 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire_DSR (E&M)-1.14.10 |
| 132 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required._DSR (E&M)-1.31 |
| 133 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required._DSR (E&M)-1.32 |
| 134 | Supply & fixing of tubelight with metal heavy duty box type batten light fitting 1x22 Watt suitable for upto 1x22 Watt LED polycorbonate complete including tube suitable for both surface & suspended complete in all respects. CAT-AAA2620 system lumens> 120Lm/W, PF>0.95, 10% at full load CRI>80, sheet thickness min 0.8 mm, tube with aluminium heat sink> 300, V over volatge protection 2.5 KV internal Surge Protection with (5 year warrenty) (1175 * 0.8475)_(PWD S.O.R. 2024) - 23.07 |
| 135 | Supply & fixing of IP 20 front Lit mid power SDM type LED light surface mounting round 6 to 9 Watt cutout min. 150mm Ht. min. 40mm/ LED down lighter having powder coated die cast aluminium housing with heat sink, high purity transmisivity UV stablized non yellowish diffuser/ reflector for uniform light distribution detachable driver set suitable for 24 hrs continuous operation complete in all respects. CAT-AAA220-1080 system lumens> 120Lm/W, PF>0.95, 10% at full load CRI>80, sheet thickness min 0.8 mm, tube with aluminium heat sink> 300, V over volatge protection 2.5 KV internal Surge Protection with (5 year warrenty) (955 * 0.8475)_(PWD S.O.R. 2024)- 23.01 |
| 136 | Supply & fixing of IP 20 front Lit mid power SDM type LED light 2'x2' 36 to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated CRCA housing body high purity transmisivity UV stablized non yellowish diffuser/ reflector for uniform light distribution detachable driver set suitable for 24 hrs continuous operation complete in all respects. CAT-AAA4320-5520 system lumens> 120Lm/W, PF>0.95, 10% at full load CRI>80, sheet thickness min 0.8 mm, tube with aluminium heat sink> 300, V over volatge protection 4 KV internal Surge Protection with (5 year warrenty) (5506 * 0.8475)_(PWD S.O.R. 2024)- 23.05 |
| 137 | Supply & fixing of Call Bell Of Approved Make on matching polished MDFEG board brass including connection etc. as required. _PWD-1101 |
| 138 | Supply & fixing of buzzer on polished MDFEG/Teak ply board including making connections etc. complete in all respect._PWD-1103 |
| 139 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)_DSR (E&M)-9.1.3 |
| 140 | Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work._10.18 (DSR Civil) |
| 141 | Supplying and fixing 3pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. as required._DSR (E&M)-1.33 |
| 142 | Supplying and fixing brass batten/ angle holder including connection etc. as required._DSR (E&M)-1.34 |
| 143 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required._DSR (E&M)-1.35 |
| 144 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes._DSR (E&M)-1.51 |
| 145 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required_DSR (E&M)-1.57 |
| 146 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 4 way (4 + 12), Double door_DSR (E&M)-2.4.1 |
| 147 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 6 way (4 + 18), Double door_DSR (E&M)-2.4.2 |
| 148 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole_DSR (E&M)-2.10.1 |
| 149 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral_DSR (E&M)-2.10.2 |
| 150 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole_DSR (E&M)-2.10.3 |
| 151 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole_DSR (E&M)-2.10.4 |
| 152 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc as required._DSR (E&M)-2.11 |
| 153 | Supplying and fixing of 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. MCB 63 Amp. TP MCB(10 KA) C Curv -CAT A_PWD-1017 |
| 154 | Supplying and fixing of 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. MCB 40 Amp. TP MCB(10 KA) C Curv -CAT A_PWD-1016 |
| 155 | Supplying and fixing of 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. MCB 63 Amp. 4 P MCB(10 KA) -CAT A_PWD-1020(A) |
| 156 | Supplying and fixing of 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. MCB 40 Amp. 4 P MCB(10 KA) C Curv -CAT A_PWD-1020 |
| 157 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelover a cushionof 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge,complete in allrespect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 35 sq. mm 3-1/2 core (724 x 0.8475)_(PWD S.O.R. 2024) 20a.1.11 |
| 158 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelover a cushionof 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge,complete in allrespect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 50 sq. mm 3-1/2 core (861 x 0.8475)_(PWD S.O.R. 2024) 20a.1.12 |
| 159 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelover a cushionof 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge,complete in allrespect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 95 sq. mm 3-1/2 core (1187 x 0.8475)_(PWD S.O.R. 2024) 20a.1.14 |
| 160 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm_DSR (E&M)-10.1.1 |
| 161 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq. mm and upto 95 sq. mm_DSR (E&M)-10.1.2 |
| 162 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm (32mm) _DSR (E&M)-11.1.21 |
| 163 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 50 sq. mm (35mm) _DSR (E&M)-11.1.22 |
| 164 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 95 sq. mm (45mm)_DSR (E&M)-11.1.24 |
| 165 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required._DSR (E&M)-5.6 |
| 166 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)_DSR (E&M)-5.9 |
| 167 | Providing and fixing 4.0 mm dia copper wire on surface or in recess for loop earthing as required._DSR (E&M)-5.17 |
| 168 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required._DSR (E&M)-2.22 |
| 169 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electricalcontrol panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA, P.F, KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrinks leeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extensionon the sides.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. The MCCB's shall be complete with suitablecable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shallbe fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. Incoming : one (1) No.200Amp. MCCB-1No. Outgoing :63 Amp. MCCB-3 Nos. Cat B Pannel Cubicle Type OR outgoing as per site requirment(AS/SLD)_(PWD S.O.R. 2024) - 20.1.2b |
| 170 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electricalcontrol panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA, P.F, KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrinks leeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extensionon the sides.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. The MCCB's shall be complete with suitablecable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shallbe fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. Incoming : one (1) No.100Amp. MCCB-1No. Outgoing : 63 Amp. MCCB- 2 Nos. Cat B Pannel Cubicle Type OR outgoing as per site requirment(AS/SLD)_(PWD S.O.R. 2024) - 20.1.1a |
| 171 | Supplying and fixing following size/modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mm x 75mm)_DSR (E&M)-1.27.1 |
| 172 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required._DSR (E&M)-1.26 |
| 173 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required. 1 run of cable_DSR (E&M)-39.17.1 |
| 174 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25 mm_DSR (E&M)-1.21.2 |
| 175 | Providing, laying, testing & Commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes, tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 80 mm dia_DSR (E&M)-27.7.6 |
| 176 | Providing, laying, testing & Commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes, tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 100 mm dia_DSR (E&M)-27.7.7 |
| 177 | Supplying fixing of Cast iron body 63 mm dia male instantaneous intel coupling with housing cabinet (500X400X400 for 2 way and 600X400 for 4 way) cap and chain for fire brigade correction conforming to IS:904 and making connection with fire fighting pipe or underground water tank completing the work in all respect as per the directions of the Engineer-in-charge. 2 way-100 mm dia M.S. Pipe_DSR (E&M)-27.19.1 |
| 178 | Supplying & fixing single headed internal / yard hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel, ISI marked, confirming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required: Single headed Gunmetal_DSR (E&M)-27.9.1 |
| 179 | Supplying & fixing First-aid hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type-2 as per IS:12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipments on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m_DSR (E&M)-27.17.1 |
| 180 | Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: Gun Metal_DSR (E&M)-27.16.1 |
| 181 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. Gun Metal_DSR (E&M)-27.18.1 |
| 182 | Supplying, Installation, Testing & Commissioning of Electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal confirming to IS 1520. (b) Suitable HP Squirrel cage indution motor, TEFC type synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, confirming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 450 lpm at 35 m head_DSR (E&M)-27.4.2 |
| 183 | Supplying, installation, testing & commissioning of addressable manual call point complete as required._DSR (E&M)-41698 |
| 184 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required._DSR (E&M)-42063 |
| 185 | Supplying, installation, testing & commissioning of addressable fire control module complete as required._DSR (E&M)-40237 |
| 186 | Supplying & laying of 2x1.5 sgmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required._DSR (E&M)-28.5.2 |
| 187 | Supplying, fixing, testing & commission of butterfly valve of PN 1.6 rating with bronze / gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 100 mm dia_DSR (E&M)-27.11.5 |
| 188 | Providing, installation, testing and commission of non-return valve of following sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 100 mm dia_DSR (E&M)-27.14.5 |
| 189 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100 mm dia_DSR (E&M)-27.15.2 |
| 190 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.._DSR (E&M)-27.20 |
| 191 | Providing and fixing pressure switch in M.S. pipe line including connection as required._DSR (E&M)-27.22 |
| 192 | Supply and laying of alluminium conductor PVC insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on side and on top on surface the cable run shall be fied on M.S. clamps etc. of suitable size or as directed by the Engineer-in-charge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sqmm 4 core = (618*0.8475)_PWD SOR 2024- 20a.1.9 |
| 193 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 + 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel_DSR (E&M)-28.2.1.2 |
| 194 | Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS :15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work._PWD Elec 2018- 1131(A) |
| 195 | Supply & fixing of fire extinguisher, CO2 Type 6.50 kg. capacity(ISI Marked IS :15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work._PWD Elec 2018- 1132 |
| 196 | Providing corrugated Rain water Gutter including bolts and nuts flat, washers & fittings etc excluding the cost of rain water pipes and including cutting to size and shape wherever required. (M.R.) |
| 197 | Providing and laying in position Polycorbonate sheet 100 micron._ M.R. |
| 198 | Pumping set KSB make submersible pumpset suitable for installation in bore well of min 100 mm inner dia preferablt more and having under noted specificaton (1.5 HP) (E/P Only)_MR |
| 199 | Supply and fixing of finolex of copper cable ISI marked submersible cable of size 4 sq mm 3 core (E/P Only) _MR |
| 200 | Supply of 300mm sweep Exhaust Fan._M.R. |
| 201 | Supplying and fixing following modular switch/ socket (RJ 45) UTP cat 6 tooless with shutter 1M White) on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Lan Point_M.R. |
| 202 | Supply, installation, testing and commissioning of 1 meter long Patch Cord complete in all respect._M.R. |
| 203 | Supply, Installation, testing and commissioning of 802.11ax Wi-Fi Indoor Aps with 4x4 MIMO and inbuilt Controller_M.R. |
| 204 | Providing / Fixing of Fire Hose cabinet box made out of 18 gauge MS sheet including two coats of post office red paint over one coat of primer with 4 mm, thick glass door in front painted “FIRE” in red luminous paint. The size of the box should be 750 mm X 600 mm X 250 mm size capable of accommodating a pair of hose with coupling and nozzle. The box should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complete. (E/P Only)_MR |
| 205 | P&F of Fire man axe made of carbon steel handle insulated with rubber tested to 20,000 Volts. Manufactured as per Indian standard IS:926. (E/P Only)_MR |
| 206 | Supply, Installation, Testing & commissioning of Single/Double sided Signage with 20 mtr. viewing distance with built in LED, High efficiency L80 LED with 50,000 hour life, Usage: Exit Signage cum Emergency light with Function Use either as an emergency luminaire or exit sign, with standalone Testing system, Housing of Polycarbonate, Glow wire test : 850°C, RAL9003, Type of mounting: Wall or ceiling, Operation Mode Non -Maintained or Maintained mode selectable, Connection voltage 230V +/- 5% [220V-240V], compliant with EN standards, with IEC CB test certificate LED, Built in Battery: Ni-Cd, Duration 3 hours, Viewing distance 2+A300m, Dimensions in mm: 270 x 119 x 49. (E/P Only)_MR |
| 207 | Supplying Installation testing & Commissioning of Public Address System complete in all respects. (E/P Only)_M.R. |
| 208 | Supplying Installation testing & Commissioning of 25 mm Air Release valve gunmental having rubber ball and with 25 mm BSP threaded male inlet including necessary accessories and connections complete in all respect. (E/P Only)_M.R. |
| 209 | Supplying Installation testing & Commissioning of 25 mm Ball valve PN-1 gunmental as per IS:778 including necessary accessories and connections. (E/P Only)_M.R. |
| 210 | Providing & fixing of pressure gauge in ranging from 0 to 14 kg per sqmm ISI marked from approved manufacturers complete in all respects. (E/P Only)_M.R. |
| 211 | Providing/Fixing of Cubical type floor mounted Fire pump Control panel fabricated from 16 G M.S. sheet duly powder coated finish of aproved shade and comprising of:a) One 63 amp. TP+NL M.C.C.B. with rotary handle of beacking capacity 35 KA.b) One Volt meter (0-500V) with selector switch.c) One set including lamps (E/P Only)_M.R. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 daySep 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender