Tender For Establishment Of 50 Bedded Drug De-Addiction Centre At Modern Psychiatric Hospital, Narsingarh, Agartala, West Tripura/ Sh: Building Portion (G+5 Storied) Including Internal Water Supply, Sanitary Installation, Sewage & Drainage Works/ Pro
Tender Overview
Project Description
Tender for Establishment Of 50 Bedded Drug De-Addiction Centre At Modern Psychiatric Hospital, Narsingarh, Agartala, West Tripura/ Sh: Building Portion (G+5 Storied) Including Internal Water Supply, Sanitary Installation, Sewage & Drainage Works/ Providing Ie Works (Conceal).
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light/ fan/ exhaust fan/ call bell point with 2x1.5 sq. mm PVC insulated copper conductor cable (FR) in PVC conduit (medium gauge) recessed in slab/ wall complete with 6/10 amps modular type switch, cover plate, GI box including necessary connection etc. as required. |
| 2 | Wiring for 2 way controlling light point with 3x1.5 sq. mm PVC insulated copper conductor cable (FR) in PVC conduit (medium gauge) recessed in slab/ wall complete with 6/10 amps modular type 2 way switch, cover plate, GI box including necessary connection etc. as required. |
| 3 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2 x 1.5 sq. mm PVC insulated Copper conductor cable (FR) on modular concealed switch board with cover plate earthing the 3rd pin etc. as required. |
| 4 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2 x 2.5 sq. mm PVC insulated Copper conductor cable (FR) on modular concealed switch board with cover plate earthing the 3rd pin etc. as required. |
| 5 | Wiring for Circuit/Sub-main with the following sizes PVC insulated Copper conductor cable (FR) in PVC conduit (medium gauge) recessed in slab/ wall etc. as required:- |
| 6 | 2 X 1.5 + 1 X 1.5 sq mm |
| 7 | 2 X 2.5 + 1 X 1.5 sq mm |
| 8 | 2 X 4 + 1 X 1.5 sq mm |
| 9 | 4 X 4 + 2 X 1.5 sq mm |
| 10 | 4 X 6 + 2 X 2.5 sq mm |
| 11 | 4 X 10 + 2 X 4 sq mm |
| 12 | 4 X 16 + 2 X 6 sq mm |
| 13 | 4 X 25 + 2 X 10 sq mm |
| 14 | 4 X 35 + 2 X 10 sq mm |
| 15 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 16 | Remote controlled call bell :- |
| 17 | 15 amps power top:- |
| 18 | Angle/batten holder :- |
| 19 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required. |
| 20 | 1-2 module plastic switch board:- |
| 21 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required. |
| 22 | 1-2 module :- |
| 23 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. |
| 24 | 3/6 pin 16/20 amps socket outlet (2M):- |
| 25 | Bell push SP (1M) :- |
| 26 | 4 step fan regulator (1M):- |
| 27 | Blank plate (1M):- |
| 28 | 20/25 amps single phase motor starter switch (2M):- |
| 29 | Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. |
| 30 | Supply and fixing of 32mm x 6 mm GI strip on walls/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. |
| 31 | Supply and fixing of 25mm x 3mm Copper on walls/ floor of the building for horizontal/ vertical network including necessary spacers and porcelain insulators at regular intervals. |
| 32 | Providing earthing system with maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminal size 32mmx 6mm including accessories with masonry enclosure of CI cover plate size 12\\"x 12\\" having locking arrangement including CC works etc as required:- |
| 33 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - |
| 34 | Supplying & installation of 300 mm sweep 900 rpm metalic body exhaust fan including connection etc as required (ISI marked) :- |
| 35 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 36 | Surface mounted integrated 20 watt LED batten with polycarbonate diffuser:- |
| 37 | Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):- |
| 38 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 39 | 45 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 40 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
| 41 | 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):- |
| 42 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 43 | 6 way horizontal TPN MCB DB (Double door):- |
| 44 | 6 way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door):- |
| 45 | 6 way vertical TPN MCB DB suitable for FP MCCB incomer upto 250 amps (Double door):- |
| 46 | Supplying, installation, testing & commissioning of powder coated prewired panel board suitable for 415 volts TP MCCB as incomer & outgoing including busbar & connection as required of the following ratings & sizes:- |
| 47 | 8 way TP MCCB outgoing & TP MCCB incomer upto 400 amps:- |
| 48 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required: |
| 49 | 6 to 32 amps SP MCB:- |
| 50 | 40/50/63 amps TP MCB:- |
| 51 | 40/50/63 amps FP MCB:- |
| 52 | Supplying & installation of Surge Protection Device (SPD) of following ratings in the existing Panels/MCB DBs including necessay connections etc as required:- |
| 53 | Surge Protection Device (SPD, withdrawable) (Type-2) with Imax 15 KA (3P+N) :- |
| 54 | Surge Protection Device (SPD, withdrawable) (Type-2) with Imax 40 KA (3P+N) :- |
| 55 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):- |
| 56 | 16 to 100 amps TP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):- |
| 57 | 16 to 100 amps FP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):- |
| 58 | 125 amps FP MCCB, Breaking capacity 25KA (Thermal Magnetic) :- |
| 59 | 250 amps FP MCCB, Breaking capacity 36KA (Thermal Magnetic) :- |
| 60 | 400 amps FP MCCB, Breaking capacity 36KA (Thermal Magnetic) :- |
| 61 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required |
| 62 | 3.5 core 300 sq mm |
| 63 | Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes : - |
| 64 | 300 sq mm :- |
| 65 | Supplying and fixing of following Cable tray made of hot dip galvanised iron:- |
| 66 | 30 mm x 50mm:- |
| 67 | 54 mm x 100 mm |
| 68 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.:- |
| 69 | Single pair 2-core 1.5 sqmm:- |
| 70 | Supplying & laying of UTP CAT 6, 305 meters,Core diameter: 0.565mm,OFC,CM,orange :- |
| 71 | Supplying & Installation of IP42, FLOOR MOUNTING/INDOOR TYPE Main L.T PANEL, fabricated with 14SWG CRCA sheet of 2.0mm thickness for Box & of 2.0mm thick passivated Gland Plate, dust and vermin proof complete with 800 Amps Aluminium BUSBAR, 25*6mm GI bus Earthing, Dimensions of 2000 (H)*6350 (W)*1000 (D), Powder coated along with the following design & specifications for Incoming & Outgoing sections & accessories, complete with necessary connections etc. as required. |
| 72 | MAIN INCOMER X 2 :- 800Amp 4Pole 50kA Microprocessor Based EDO ACB 2 nos, 800Amp ACB Under Voltage Coil 240V AC Coil 2 nos, 3Ph Digital LED Type Display Multifunction Meter 2 nos, Led type Phase – 1 Indication Lamp (Red) 2 nos, Led type Phase – 2 Indication Lamp (Yellow) 2 nos, Led type Phase – 3 Indication Lamp (Blue) 2 nos, Led type On Indication Lamp (Red) 2 nos, Led type Off Indication Lamp (Green) 2 nos, Led type Trip Indication Lamp (Amb) 2 nos, TNC Switch 2 nos, Selector Switch 2 nos, 2NO+2NC Auxiliary Contactors 220V AC Coil 6 nos, 6Amp 2Pole C-Curve MCB For Control Circuit 2 nos, 6Amp 1Pole C-Curve MCB For Control Circuit 6 nos, 800/5A Class -1 Tape Wound CT Coil 6 nos. DG INCOMER X 1 :- 800Amp 4Pole 50kA Microprocessor Based EDO ACB 1 nos, 800Amp ACB Under Voltage Coil 240V AC Coil 1 nos, 3Ph Digital LED Type Display Multifunction Meter 1 nos, Led type Phase – 1 Indication Lamp (Red) 1 nos, Led type Phase – 2 Indication Lamp (Yellow) 1 nos, Led type Phase – 3 Indication Lamp (Blue) 1 nos, Led type On Indication Lamp (Red) 1 nos, Led type Off Indication Lamp (Green) 1 nos, Led type Trip Indication Lamp (Amb) 1 nos , TNC Switch 1 nos, Selector Switch 1 nos, 2NO+2NC Auxiliary Contactors 220V AC Coil 3 nos, 6Amp 2Pole C-Curve MCB For Control Circuit 1 nos,6Amp 1Pole C-Curve MCB For Control Circuit 3 nos, 800/5A Class -1 Tape Wound CT Coil 3 nos. |
| 73 | BUS COUPLER X 2 :-800Amp 4Pole 50kA Microprocessor Based EDO ACB 2 nos, 800Amp ACB Under Voltage Coil 240V AC Coil 2 nos, Led type Phase – 1 Indication Lamp (Red) 2 nos, Led type Phase – 2 Indication Lamp (Yellow) 2 nos, Led type Phase – 3 Indication Lamp (Blue) 2 nos, Led type On Indication Lamp (Red) 2 nos, Led type Off Indication Lamp (Green) 2 nos, Led type Trip Indication Lamp (Amb) 2 nos, TNC Switch 2 nos, Selector Switch 2 nos, 2NO+2NC Auxiliary Contactors 220V AC Coil 6 nos, 6Amp 2Pole C-Curve MCB For Control Circuit 2 nos, 6Amp 1Pole C-Curve MCB For Control Circuit 6 nos. OUTGOING :- 320Amp 4Pole 36kA Thermal Magnetic MCCB 2 nos, 320Amp 4Pole Spreader Terminal 2 set, 320Amp 4Pole MCCB Rotary Handle 2 nos, 250Amp 4Pole 36kA Thermal Magnetic MCCB 2 nos, 250Amp 4Pole Spreader Terminal 2 set, 250Amp 4Pole MCCB Rotary Handle 2 nos, 160Amp 4Pole 25kA Thermal Magnetic MCCB 6 nos, 160Amp 4Pole Spreader Terminal 6 set, 160Amp 4Pole MCCB Rotary Handle 6 nos, 100Amp 4Pole 25kA Thermal Magnetic MCCB 4 nos, 100Amp 4Pole Spreader Terminal 4 set, 100Amp 4Pole MCCB Rotary Handle 4 nos, 63Amp 4Pole 25kA Thermal Magnetic MCCB 1 nos, 63Amp 4Pole Spreader Terminal 1 set, 63Amp 4Pole MCCB Rotary Handle 1 nos. |
| 74 | Supplying, installation, testing and commissioning of 100 KVA/100kW Double conversion online UPS with 3ph-input and 3 ph output with IGBT based Inverter and IGBT Rectifier, 50/60Hz rated frequency, P.F range 0.7 leading to 0.5 lagging, efficiency 0.99 in Eco Mode and upto .965 in Online Mode, Voltage regulation +/-1%, Pure sine wave form, total harmonic distortion < 3% with full load, Noise level 65db at 1m, LED indication for Normal mode/Load on battery/Load on bypass/System fault, Audible alarm for Mains failure, low battery, Overload, fault and Bypass mode, Inbuilt static and maintenance bypass, Input phase sequence correction, EPO-emergency power off with all other necessary accessories including connections etc. as required with Battery rack, FR interlinks and accessories for 12V-200AH, 40nos battery with 30 minutes backup :- |
| 75 | Supplying, installation, testing and commissioning of 12 Volt 200 AH SMF VRLF Battery with all accessories including necessary connections etc. as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender