Tender For Internal Electrification Of Town Hall At Sora Municipality, Baleshwar,Odisha.
Tender Value
16.92 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
8 days left
EMD
16924
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baleshwar → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Internal Electrification Of Town Hall At Sora Municipality, Baleshwar,Odisha.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-Sep-2026 | Slight correction in DTCN | Other | 21-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Kalyan Mandap / MPH / Open Air theatre Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R & B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work.Group C |
| 2 | Recessed wiring to secondary light point looped from primary light point with 1.5sqmm FRLS PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia HMS FRLS PVC conduit ISI marked with 1.5sqmm FRLS PVC insulated single core multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge.(Make of Wires- Finolex / Anchor / Polycab / HAVELLS / RR KABEL / KEI) or equivalent) (Make of Conduit-AKG / BEC / Precision / Norpak / Anchor / Kinjal or equivalent reputed make A catagory ISI marked as approved) (Make of switch/socket- Schneider(Zencelo) / legrand( Myrius-NEXT GEN) / Panasonic (vision) or equivalent) (Make of accessories- Anchor/Havells) (Make of G.I box, face plate & cover-Schneider(Zencelo) / legrand( Myrius-NEXT GEN) / Panasonic (vision) or equivalent reputed make & model A catagory ISI marked as approved). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Average Length: 3 mtr. |
| 3 | Recessed wiring to ceiling fan point with 1.5sqmm FRLS PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia HMS FRLS PVC conduit ISI marked with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FRLS PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of Wires- Finolex / Anchor / Polycab / HAVELLS / RR KABEL / KEI) or equivalent) (Make of Conduit-AKG / BEC / Precision / Norpak / Anchor / Kinjal or equivalent reputed make A catagory ISI marked as approved) (Make of switch/socket- Schneider(Zencelo) / legrand( Myrius-NEXT GEN) / Panasonic (vision) or equivalent) (Make of accessories- Anchor/Havells) (Make of G.I box, face plate & cover-Schneider(Zencelo) / legrand( Myrius-NEXT GEN) / Panasonic (vision) or equivalent reputed make & model A catagory ISI marked as approved). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 4 | Supplying, fixing of 5 pin 6A socket outlet in the existing switch board with complete fitting by 01 no of 6A switch (modular type) (anti bactorial & flame retradant type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 5 | Supplying, fixing of 5 pin 6A socket outlet & 6A clip in type switch (modular type) (anti bactorial & flame retradant type) in separate board with complete fitting & suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make- Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision). (Maximum 03 nos point in one circuit). All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 6 | Recessed wiring for 2 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer in Charge. (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent) |
| 7 | Supplying, fixing of 6 pin 16 amp modular socket outlet with 16Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision). (Maximum 02 nos point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 8 | Supplying, fixing of 6 pin 16 amp modular socket outlet (for Projector/ Geyser / 1.5 TR A.C point) ISI marked mounted on separate G.I moular box and 16A clip in type modular switch ISI marked mounted on separate G.I moular box at nearest location with modular face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision). (Only 01 no point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 9 | Supplying, fixing of 20A SPN Industrial type socket outlet with plug top and metal chained cover in sheet steel enclosure including all accesories and connection as per direction of Engineer in Charge. Make- Legrand / Schneider / Siemens / L&T. (Only 01 no point in one circuit). All the equipments should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 10 | Recessed wiring to submain in 4 x 16sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 50 mm dia non-metalic heavy duty PVC conduit along with 2 x 10 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) (POWER DB) |
| 11 | Recessed wiring to submain in 4 x 10 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 40 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) (For LPDB) |
| 12 | Recessed wiring to submain in 4 x 6sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) (For LIGHT DB) |
| 13 | Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) (For POWER CKT / 1.5 TR AC) |
| 14 | Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) |
| 15 | Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) |
| 16 | Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ Isolator) (Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalent model) /ABB(Equivalant model) or equievalant. 6 way (4 + 18 ), TPN , MCB DB double door horizontal type |
| 17 | Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ Isolator) (Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalent model) /ABB(Equivalant model) or equievalant. 8way (4 + 24 ), TPN , MCB DB double door horizontal type |
| 18 | Supply and fixing of following rating 240 V Minature Circuit Breaker (MCB) having a sensitivity current up to 10kA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. (Make-LEGRAND- DX3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant. 6 amp to 32 amp rating SP MCB , \\"c\\" series, 10KA breaking capacity |
| 19 | Supply and fixing of following rating 240 V Residual Current Circuit Breaker (RCCB) having a sensitivity current up to 300mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. (Make-LEGRAND- DX3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant. 25 amp rating FP RCCB, 30mA |
| 20 | Supply and fixing of following rating 240 V Residual Current Circuit Breaker (RCCB) having a sensitivity current up to 300mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. (Make-LEGRAND- DX3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant. 40 amp rating FP RCCB, 100/300 mA |
| 21 | Supply and fixing of following rating 240 V Residual Current Circuit Breaker (RCCB) having a sensitivity current up to 300mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. (Make-LEGRAND- DX3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant. 63 amp rating FP RCCB, 100/300 mA |
| 22 | Earthing with G.I. earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required. |
| 23 | Extra for using salt and charcoal for G.I or copper plate earth as required |
| 24 | Supplying and laying 25 mm x 6 mm G.I earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required. |
| 25 | Supplying and laying 25 mm x 5 mm G.I earth strip ISI marked on surface or in recess for connection etc as required. |
| 26 | Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required. Recess mounted indoor type IRIS NEO 15W ROUND LED Luminaire with LED Lamp & driver Similar to WIPRO Cat No. LD95-171-XXX-65-G1 / JAQUAR / Philips / Halonix / Panasonic or equivalent. |
| 27 | Surface mounted indoor type Iris Slim 12W ROUND LED Luminaire with LED Lamp & driver Similar to WIPRO Cat No. LD80-101-XXX-60-SM / JAQUAR / Philips / Halonix / Panasonic or equivalent. |
| 28 | Recess mounted indoor type Elate 36W 2'x2' Square LED Luminaire with LED Lamp & driver Similar to WIPRO Cat No. CRCO10R038HP57G1L1 / JAQUAR / Philips / Halonix / Panasonic or equivalent. |
| 29 | Wall mounted 5W DECORATIVE WALL LIGHT frosted glass with antique brass finish & LED driver Similar to JAQUAR Cat No. DWL-ABR-WL5010W / Wipro / Philips / Halonix / Panasonic or equivalent. |
| 30 | Surface mounted indoor type Trim Neo 10W SINGLE LED TUBE for Mirror Light polycarbonate housing Luminaire with LED Lamp & driver Similar to WIPRO Cat No. LL20-111-XXX-65NE3 / JAQUAR / Philips / Halonix / Panasonic or equivalent. |
| 31 | Indoor type 40W LED COB TRACK luminaire with extruded aluminium housing Similar to WIPRO Cat No. LD57-501-60-57-WG1 / JAQUAR / Philips / Halonix / Panasonic or equivalent. |
| 32 | 2 meter LED COB TRACK housing for Track Light with straight connector and 1 meter suspension for track Similar to WIPRO Cat No. XTS5200WG2 / JAQUAR / Philips / Halonix / Panasonic or equivalent. |
| 33 | Surface mounted indoor type 20W PROFILE LED Luminaire with LED Lamp Similar to WIPRO Cat No. LM37S-201-XX-57-G2 / JAQUAR / Philips / Halonix / Panasonic or equivalent. |
| 34 | Indoor / Outtdoor type 25W IP65 Strip LED light 5W per meter with LED driver Similar to JAQUAR Cat No. STI-WHT-LSTP04X005XW / WIPRO / Philips / Halonix / Panasonic or equivalent. |
| 35 | Supply, Installation, Testing and Commissioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years. |
| 36 | Supply, Installation, testing and commissioning of heavy duty Exhaust Fan of 300 mm sweep 1400 rpm with louvers similar to Havells (Ventil Air DS) (Make- Havells / Crompton / Usha / Orient / Bajaj or equivalent) of exhaust fan in the existing wall, existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 37 | Providing and fixing extra down rod of 50 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored |
| 38 | Recessed wiring to telephone point with clip in type modular telephone socket (RJ 11) ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge. |
| 39 | Recessed wiring to LAN point with clip in type modular lan socket (RJ45) ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge. |
| 40 | Supplying and fixing of 25mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required. |
| 41 | Supplying and drawing one pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessed PVC conduit as required. |
| 42 | Supplying and drawing UTP 4 pair LAN cat-6 cable in the existing surface / recessed PVC conduit as required. |
| 43 | Supply and installation of Rubber Mats 12mm thick of size 2000mm x 1000mm x 12 mm thick Electrical tested with test certificate. |
| 44 | Supply and fixing of fire buckets with angular fabricated stand to fix 4 buckets in each stand for Electrical fire protection as per standards of Electrical Inspectorate. |
| 45 | Supply and fixing of Co2 fire extinguisher with mounting clamps with pressure test certificate . |
| 46 | Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room. |
| 47 | Supply and handing over 11KV Tested Rubber hand gloves to be used on LT supply with Test certificate. |
| 48 | Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 11, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Sep 21, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysSep 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender