Public Administrative Department Local Bodies Closing in 8 days TDR #57418123

Tender For Internal Electrification Of Town Hall At Sora Municipality, Baleshwar,Odisha.

Issued by Local Bodies · Baleshwar, Odisha
Tender Value
16.92 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
8 days left
EMD
16924
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Baleshwar → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Internal Electrification Of Town Hall At Sora Municipality, Baleshwar,Odisha.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 11-Sep-2026 Slight correction in DTCN Other 21-Sep-2026

BOQ

Name of Work:- INTERNAL ELECTRIFICATION OF TOWN HALL AT SORA MUNICIPALITY, BALESHWAR,ODISHA.
Sl. No. Item Description
1Kalyan Mandap / MPH / Open Air theatre Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R & B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work.Group C
2Recessed wiring to secondary light point looped from primary light point with 1.5sqmm FRLS PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia HMS FRLS PVC conduit ISI marked with 1.5sqmm FRLS PVC insulated single core multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge.(Make of Wires- Finolex / Anchor / Polycab / HAVELLS / RR KABEL / KEI) or equivalent) (Make of Conduit-AKG / BEC / Precision / Norpak / Anchor / Kinjal or equivalent reputed make A catagory ISI marked as approved) (Make of switch/socket- Schneider(Zencelo) / legrand( Myrius-NEXT GEN) / Panasonic (vision) or equivalent) (Make of accessories- Anchor/Havells) (Make of G.I box, face plate & cover-Schneider(Zencelo) / legrand( Myrius-NEXT GEN) / Panasonic (vision) or equivalent reputed make & model A catagory ISI marked as approved). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Average Length: 3 mtr.
3Recessed wiring to ceiling fan point with 1.5sqmm FRLS PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia HMS FRLS PVC conduit ISI marked with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FRLS PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of Wires- Finolex / Anchor / Polycab / HAVELLS / RR KABEL / KEI) or equivalent) (Make of Conduit-AKG / BEC / Precision / Norpak / Anchor / Kinjal or equivalent reputed make A catagory ISI marked as approved) (Make of switch/socket- Schneider(Zencelo) / legrand( Myrius-NEXT GEN) / Panasonic (vision) or equivalent) (Make of accessories- Anchor/Havells) (Make of G.I box, face plate & cover-Schneider(Zencelo) / legrand( Myrius-NEXT GEN) / Panasonic (vision) or equivalent reputed make & model A catagory ISI marked as approved). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
4Supplying, fixing of 5 pin 6A socket outlet in the existing switch board with complete fitting by 01 no of 6A switch (modular type) (anti bactorial & flame retradant type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
5Supplying, fixing of 5 pin 6A socket outlet & 6A clip in type switch (modular type) (anti bactorial & flame retradant type) in separate board with complete fitting & suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make- Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision). (Maximum 03 nos point in one circuit). All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
6Recessed wiring for 2 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer in Charge. (Make of switch/socket- Schneider(Zencelo)/Legrand( myrius) /Panasonic (Europa)/Havells(Equivalent model) or equivalent)
7Supplying, fixing of 6 pin 16 amp modular socket outlet with 16Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision). (Maximum 02 nos point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
8Supplying, fixing of 6 pin 16 amp modular socket outlet (for Projector/ Geyser / 1.5 TR A.C point) ISI marked mounted on separate G.I moular box and 16A clip in type modular switch ISI marked mounted on separate G.I moular box at nearest location with modular face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision). (Only 01 no point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
9Supplying, fixing of 20A SPN Industrial type socket outlet with plug top and metal chained cover in sheet steel enclosure including all accesories and connection as per direction of Engineer in Charge. Make- Legrand / Schneider / Siemens / L&T. (Only 01 no point in one circuit). All the equipments should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
10Recessed wiring to submain in 4 x 16sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 50 mm dia non-metalic heavy duty PVC conduit along with 2 x 10 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) (POWER DB)
11Recessed wiring to submain in 4 x 10 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 40 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) (For LPDB)
12Recessed wiring to submain in 4 x 6sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) (For LIGHT DB)
13Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant) (For POWER CKT / 1.5 TR AC)
14Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant)
15Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire- Finolex/Anchor/Polycab/ HAVELLS/RR KABEL or equivalent) (Make of conduit-AKG/Anchor/Kinjal or equievalant)
16Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ Isolator) (Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalent model) /ABB(Equivalant model) or equievalant. 6 way (4 + 18 ), TPN , MCB DB double door horizontal type
17Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ Isolator) (Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalent model) /ABB(Equivalant model) or equievalant. 8way (4 + 24 ), TPN , MCB DB double door horizontal type
18Supply and fixing of following rating 240 V Minature Circuit Breaker (MCB) having a sensitivity current up to 10kA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. (Make-LEGRAND- DX3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant. 6 amp to 32 amp rating SP MCB , \\"c\\" series, 10KA breaking capacity
19Supply and fixing of following rating 240 V Residual Current Circuit Breaker (RCCB) having a sensitivity current up to 300mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. (Make-LEGRAND- DX3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant. 25 amp rating FP RCCB, 30mA
20Supply and fixing of following rating 240 V Residual Current Circuit Breaker (RCCB) having a sensitivity current up to 300mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. (Make-LEGRAND- DX3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant. 40 amp rating FP RCCB, 100/300 mA
21Supply and fixing of following rating 240 V Residual Current Circuit Breaker (RCCB) having a sensitivity current up to 300mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. (Make-LEGRAND- DX3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant. 63 amp rating FP RCCB, 100/300 mA
22Earthing with G.I. earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required.
23Extra for using salt and charcoal for G.I or copper plate earth as required
24Supplying and laying 25 mm x 6 mm G.I earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required.
25Supplying and laying 25 mm x 5 mm G.I earth strip ISI marked on surface or in recess for connection etc as required.
26Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required. Recess mounted indoor type IRIS NEO 15W ROUND LED Luminaire with LED Lamp & driver Similar to WIPRO Cat No. LD95-171-XXX-65-G1 / JAQUAR / Philips / Halonix / Panasonic or equivalent.
27Surface mounted indoor type Iris Slim 12W ROUND LED Luminaire with LED Lamp & driver Similar to WIPRO Cat No. LD80-101-XXX-60-SM / JAQUAR / Philips / Halonix / Panasonic or equivalent.
28Recess mounted indoor type Elate 36W 2'x2' Square LED Luminaire with LED Lamp & driver Similar to WIPRO Cat No. CRCO10R038HP57G1L1 / JAQUAR / Philips / Halonix / Panasonic or equivalent.
29Wall mounted 5W DECORATIVE WALL LIGHT frosted glass with antique brass finish & LED driver Similar to JAQUAR Cat No. DWL-ABR-WL5010W / Wipro / Philips / Halonix / Panasonic or equivalent.
30Surface mounted indoor type Trim Neo 10W SINGLE LED TUBE for Mirror Light polycarbonate housing Luminaire with LED Lamp & driver Similar to WIPRO Cat No. LL20-111-XXX-65NE3 / JAQUAR / Philips / Halonix / Panasonic or equivalent.
31Indoor type 40W LED COB TRACK luminaire with extruded aluminium housing Similar to WIPRO Cat No. LD57-501-60-57-WG1 / JAQUAR / Philips / Halonix / Panasonic or equivalent.
322 meter LED COB TRACK housing for Track Light with straight connector and 1 meter suspension for track Similar to WIPRO Cat No. XTS5200WG2 / JAQUAR / Philips / Halonix / Panasonic or equivalent.
33Surface mounted indoor type 20W PROFILE LED Luminaire with LED Lamp Similar to WIPRO Cat No. LM37S-201-XX-57-G2 / JAQUAR / Philips / Halonix / Panasonic or equivalent.
34Indoor / Outtdoor type 25W IP65 Strip LED light 5W per meter with LED driver Similar to JAQUAR Cat No. STI-WHT-LSTP04X005XW / WIPRO / Philips / Halonix / Panasonic or equivalent.
35Supply, Installation, Testing and Commissioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.
36Supply, Installation, testing and commissioning of heavy duty Exhaust Fan of 300 mm sweep 1400 rpm with louvers similar to Havells (Ventil Air DS) (Make- Havells / Crompton / Usha / Orient / Bajaj or equivalent) of exhaust fan in the existing wall, existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
37Providing and fixing extra down rod of 50 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored
38Recessed wiring to telephone point with clip in type modular telephone socket (RJ 11) ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.
39Recessed wiring to LAN point with clip in type modular lan socket (RJ45) ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.
40Supplying and fixing of 25mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.
41Supplying and drawing one pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessed PVC conduit as required.
42Supplying and drawing UTP 4 pair LAN cat-6 cable in the existing surface / recessed PVC conduit as required.
43Supply and installation of Rubber Mats 12mm thick of size 2000mm x 1000mm x 12 mm thick Electrical tested with test certificate.
44Supply and fixing of fire buckets with angular fabricated stand to fix 4 buckets in each stand for Electrical fire protection as per standards of Electrical Inspectorate.
45Supply and fixing of Co2 fire extinguisher with mounting clamps with pressure test certificate .
46Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room.
47Supply and handing over 11KV Tested Rubber hand gloves to be used on LT supply with Test certificate.
48Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57418123
AUTHORITY Local Bodies
TENDER VALUE 16.92 Lakhs
LAST DATE 21-09-2026
Authority
Authority Name Municipal Bodies
Work Description Tender for Internal Electrification Of Town Hall At Sora Municipality, Baleshwar,Odisha.
Basic Detail
Tender No SOROM_05_2026-27
Bidding Type Tender
Location
City Baleshwar
State Odisha
Key Dates
Publish Date 11 Sep 2026
Submission Date 21 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value 16.92 Lakhs
Tender Fee 6000
EMD 16924
Exemption Available
Document List
7b26f577-bdb9-4cac-9727-b93b8a863fa2.html
BOQ_608735.xls
Tendernotice_1 (19).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 8 days
Sep 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

7b26f577-bdb9-4cac-9727-b93b8a863fa2.html

xls

BOQ_608735.xls

pdf

Tendernotice_1 (19).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders