Tender For Special Repairs To Sailors Married Accomodation (P-84) Building At installation Dronacharya
Tender Overview
Project Description
Tender for Special Repairs To Sailors Married Accomodation (P-84) Building At installation Dronacharya
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-Sep-2026 | amendment01 | Date | 12-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed. |
| 2 | Demollition of Cement concrete (unreinforced) n exc 15 cm thickness (below or above ground floors) complete all as specified and directed . |
| 3 | M&L PCC 25 mm thick, type B-1, 1:2:4, using 20 mm graded stone aggreage as in levelling the undulated floor area etc. complete all as specified and directed. |
| 4 | M&L 15 mm thick screed bedding layers in cement mortar 1:6 for laying floor finishes tiles etc. complete all as specified and directed. |
| 5 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.09 sqm but not exceeding 0.11 sqm, as in floors installation with spacer and fixed with neat cement slurry and joints filled with epoxy grout of matching colour cement to match with tile colour complete all as specified and directed |
| 6 | M&L for Non-skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade etc. complete all as specified and directed. |
| 7 | M&L for Non-skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in skirting incl necessary cutting etc. and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade etc. complete all as specified and directed. |
| 8 | M&L for Rendering 10 mm thick in CM 1:4 on brick or concrete surfaces, finished fair and even for receiving wall tiles etc. complete all as specified and directed. |
| 9 | M&L for glazed ceramic tiles, coloured of size 7 mm thick area of each tile exceeding 0.12 sqm but not exceeding 0.18 sqm as in dado/skirting and riser to steps and jointed in neat cement slurry and pointed in white or coloured cement to match complete etc. complete all as specified and directed. |
| 10 | Demolition of Stone slabs and tiles of any description or thickness in platforms, floors, aprons laid in cement mortor etc and rubbish off the premises etc. complete all as specified and directed. |
| 11 | M&L 20 mm thick screed bedding layers in cement mortar 1:6 for laying topping layer etc. complete all as specified and directed. |
| 12 | M&L Granite (of any type) work(table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to matchwith shade of granite 18 mm thick complete all as specified and directed. |
| 13 | M & L 20 to 25 mm thick machine cut polished kota stone slab as in flooring/ landings over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing complete all as specified and directed. |
| 14 | M & L 18 to 19 mm thick machine cut polished kota stone slab as in staircase treads & risers and providing 03 Nos full length anti slip groves to each tread complete all as specified and directed. Note: Each tread and riser provided in one single piece. |
| 15 | M&L machine cut polished kota stone 12 to 16 mm thick over cement screed as in skirting/dado laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 16 | M&L for rounding to edges of stone slab one edge , such as in steps treads, cooking paltforms, and similar situations etc. complete all as specified and directed. |
| 17 | M&L for chippping and removing all damaged and de bonded concrete and plaster from the soffit of RCC slabs by manually or mechanically so as to expose the corroded reinforcement bars, removing the debris with in a lead of 100 meters etc. complete all as specified and directed. |
| 18 | M&L for supply and application of Nitobond EP (Manufactured by M/s Fosroc chemicals India Ltd) epoxy bonding agent over the old concrete surface complete all as specified and all as directed by Engineer-in-charge. |
| 19 | M&L for application Rust Remover/converter (Fosroc Reebaklens RR or Amandur of GK technocom) over the corroded reinforcement bar where ever micro concreting is required and cleaning the same after application complete all as specified and directed by Engineer-in-charge. |
| 20 | M&L for plastering with Nitobond SBR (Styrene butadin polymer bonding agent cum cement mortar/concrete modifier Manufactured by M/s Fosroc Chemicals India Ltd) modified cement mortar (1:4) under the slab to an average thickness of 40 mm (applied in two layers not exceeding 20mm each) , including the cost of all materials rent of tools and labour charges etc complete all as directed by Engr-in-charge. |
| 21 | M&L for rendering 15 mm thick in two coats (5 mm thick in cement mortar 1:4 with water proofing compound over 10 mm thick plaster in CM 1:4) on fair faces of brick work or concrete blocks surfaces finished even and smooth without using extra cement including Taking down cement plaster of any description on walls including raking out joints, hacking for key scrubbing down with water etc.complete all as specified and directed by Engineer-in-charge.(Note- water proofing compound shall be measured and paid seperately) . |
| 22 | M&L for Finishing walls with Acrylic Smooth exterior weather proof paint of required shade work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) new prepared plastered external surfaces and including scafoldings and cradles including hoisting and lowering as required with bracing , support complete all as specified. Note : Height of the Bldg is approx 18.00 mtrs etc. |
| 23 | M&L for 10 mm thick plastering in CM 1:6, on internal walls finished even and smooth w/o using extra cement etc including Taking down cement plaster of any description on walls including raking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed by Engineer-in-charge. |
| 24 | Taking down chowkats or frames not exc. 1.5 Sqm each with shutters (without taking off shutters from the frame) etc.of any description, complete all as specified and directed. |
| 25 | Taking down chowkats or frames exc. 1.5 Sqm and not exc 4.00 sqm each with shutters (without taking off shutters from the frame) etc. of any description,complete all as specified and directed. |
| 26 | Dismantling wrought iron or mid steel work of any description not otherwise provided for etc. all as specified and as directed. |
| 27 | S&F Stainless steel plate rack of size 780x750mm complete all as specified and directed. |
| 28 | S&F in repairs drapery curtain rods stainless steel of dia 25 mm and thickness not less than 1.00 mm including ornamental brackets & designer dooms complete as specified and as directed. |
| 29 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. |
| 30 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size withnecessary full body threaded star headed counter sunk S.S screws, complete all as per direction of Engineer-In-Charge. |
| 31 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door Chowkhat of size 65x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. |
| 32 | S&F 35mm thick Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid decorative type flush door shutter comprising of virginpolymer of K value 58-60 (Suspension Grade), calciumcarbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicityindex of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face)& 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 andresistance to spread of flame of Class A category withproperty of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVCfoil of minimum 14 microns thick of approved designpasted with hot melt adhesive on both faces of shutterand fixing with stainless steel butt hinges of requiredsize with necessary full body threaded star headedcounter sunk S.S screws, all as per direction of EngineerIn- Charge. (Note: stainless steel butt hinges andnecessary S.S screws shall be paid separately) |
| 33 | S&F 35 mm thick WPC skelton door panel with top panel and both vertical panels(left &right side) with a stiles 100 mm wide,top rail 150 mm.middle rail and bottom rail 200 mm wide and including fixing of stainless steel(Grade 304 ) wire cloth of 0.36mm nominal dia and width of apperature 1.40mm incuding WPC beeding to fix the wire mesh inside the door panel and fixing ,all as specified and directed by Engineer In Charge. |
| 34 | S&F Providing and fixing factory made uPVC white colour Sliding window /ventilator Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame(88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (Onevertical length in each shutters) (45.5mm x 28mm),Glazing bead (24.5mm x 16mm) will be miterd cutand fusion welded at all corners, including drillingof holes for fixing hardware and drainage of wateretc., making arrangement for fixing of hardware.EPDM gasket, 1.2+ -0.2mm thick galvanised steelFrame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile tobe inserted in required profile, frame will be fixed tothe wall with 8mm x 100mm long fasteners, Hardware[Touch Lock of zinc alloyed (white powder coated),steel roller system. Stainless steel wire cloth 0.36mmnominal dia of wire and average width of aperture1.40mm and required accessories.(Note: The unit rate quoted by contractor excludescost of glass and includes all other connectedaccessories. Net Opening will be measured lorpayment purpose.)(A) Area not exceeding 2.00 sqm each |
| 35 | S&F mild steel hold fasts conforming to Fe-290 Gde-E-165 for fixing chowkats etc. complete all as specified and directed. |
| 36 | M&L for PCC 1:2:4 type B1 (using 20mm graded aggregate) as in bed blocks for fixing hold fasts etc. complete all as specified and directed. |
| 37 | M&L preparing surfaces of treating small articles such as hold fasts ends of post ,etc area n.exc 0.10 sqm each and treated with tar or coal tar black paint etc. complete all as specified. |
| 38 | M&L for preparation of old treated wooden surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed. |
| 39 | S/F stainless steel butt hinges 100mm size medium weight etc. complete all as specified and directed. |
| 40 | S&F anodised aluminium extruded handles 150 mm size etc. complete all as specified and directed. |
| 41 | S&F aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc. complete all as specified and directed. |
| 42 | S&F staineless steel (Grade 304) wire cloth, 0.36 mm, nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples etc. complete all as specified and directed. |
| 43 | M&L for powder coated aluminium coated deco grill of approved colour, design & pattern, with approved standard section fixed to window frame with 'F' channels & stainless steel screws @ 200 mm centre to centre complete all as specified and directed. |
| 44 | M/L for 18mm thick solid WPC(wood polymer composite)boards one side prelaminated with wood grains having density not less than 650 Kg/cum ,fixed with Stainelss screws as in cup boar& kitchen cabinets complete all as specified and directed. |
| 45 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 46 | M&L for RCC 1:2:4 nominal mix, type B1 (using 20mm graded stone aggregates) for Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, chajja, kitchen platforms & shelves etc complete all as specified and directed. |
| 47 | Formwork to sides and soffits of shelves, kitchen platforms, chajja, including supports, overhangs, etc. also etc. complete all as specified and directed. |
| 48 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, slab, shelves etc, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 49 | S&F SS clip-on soft close concealed cabinet hinges fixed with SS screws Make: Hettich, Godrej or equivalent in approved make etc. complete all as specified. |
| 50 | S&F anodised aluminium extruded handles 100 mm size etc. complete all as specified and directed. |
| 51 | S&F stainless steel magnetic door catcher for cupboards shutters fixed with ss screws. complete all as specified and directed. |
| 52 | S&F 100mm size Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed. |
| 53 | S&F in repairs 140mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 54 | S&F in repairs 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 55 | S&F in 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square but exc 0.5 sq. m each pane etc. complete all as specified and directed. |
| 56 | Demolition of brick masonry built in cement mortar or cement lime mortar etc. complete all as specified and directed. |
| 57 | M&L precast cement concrete 1:3:6, type C1 (20 mm graded stone aggragate) block masonary with solid blocks, exc. 10 cm in width and setting in CM 1:6 etc. complete all as specified and directed. |
| 58 | M&L providing and injecting chemical emulsion for post constructional Anti-termite treatment along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 ltr per linear meter including drilling and plugging holes etc in apron etc complete all as specified and directed. |
| 59 | M&L for treating points of contact of wood work with masonary / concrete by chemical emulsion (in oil or kerosene based solution) @ 0.50 litre/hole by drilling 6 mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same all as specified and directed. |
| 60 | M&L for treating soil under existing floor at internal junctions with wall using chemical emulsion @ 1.00 ltr per hole, 300 mm apart including drilling and plugging 12 mm dia holes with CM 1:2 to match the existing floors , all as specified and directed. |
| 61 | Removing vegeitation/plants from buildings near chajjas, water tanks etc and removing roots complete all as specified and directed. |
| 62 | S&F in repairs vitreous china wash down water closet (Pedestal pattern) white with 'P' trap complete including plastic seat cover white closed pattern with flat bottom, and cover with plastic hinges complete all as specified. |
| 63 | S&F in repairs PVC low level flushing cistern 10 Ltr capacity incl float valve and flush pipe etc complete all as specified and directed. |
| 64 | S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook, fixed in position complete all as specified and directed. |
| 65 | S&F in repairs vitreous china wash basin, white flat back, size 550 X 400 mm excluding taps, fixed to wall by anchor bolts , including brass CP waste coupling, waste pipe etc complete all as specified and directed. |
| 66 | S&F 450mm long Shelf of PTMT with SS screws and PVC rawal plugs complete all as specified and directed. |
| 67 | S&F in repair fancy type 15mm bore pillar taps cast copper alloy, with capstan head, chromium plated, screwed down , high pressure, with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 68 | S&F in repairs 2 way bib cock, fancy type, Brass CP 15mm bore cast copper alloy with crutch or butterfly handle, screwed down complete all as specified and directed. |
| 69 | S&F in repairs long body bib cock, fancy type, Brass CP 15mm bore cast copper alloy with crutch or butterfly handle, screwed down complete all as specified and directed. |
| 70 | S&F in repairs angle stop valve, fancy type, Brass CP 15mm bore cast copper alloy with crutch or butterfly handle, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed. |
| 71 | S&F in repairs 125 mm dia Brass CP shower roses with or without swivel joints, including fixing with shower arm 15 mm size, 195 mm long withbend of 45 degree with flange complete all as specified and directed. |
| 72 | S&F Brass CP wall mixer (three-in-one) for mixing hot & cold water screwed down for iron pipe , dia of tube in 15mm complete all as specified and directed. |
| 73 | S&F in repairs PVC inlet connections 450 mm long, 15 mm bore with PTMT nuts etc complete all as specified and directed. |
| 74 | S&F in repairs 600mm x 600mm bevelled edge mirror of selected quality glass (frameless) with stainless steel bracket and screws complete all as specified and directed |
| 75 | S&F in repairs 600mm long tubular towel rail 20 mm dia, brass chromium plated, complete all as specified and directed |
| 76 | S&F in repairs Stainless steel soap dish fixed with SS screws etc. complete all as specified and directed. |
| 77 | S&F in repairs sink with drainage boards made of stainless steel 1 mm thick kitchen with plugs, washers and waste; including bedding in cement mortar to dwarf wall/Granite or including fixing and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete (sink counter sunk into granite platform) etc. complete all as specified and directed. |
| 78 | Demolition of concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 79 | M&L PCC 75 mm thick, PCC 1:3:6, Type C1 (using 20mm graded crushed stone aggregate) as in plinth protection etc. complete all as specified and directed. |
| 80 | M&L PCC 1:3:6 (Type C2) using 40mm graded crushed stone aggregate as in surface channels and drain etc. complete all as specified and directed. |
| 81 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and directed. |
| 82 | S&F in repairs for PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to wall GI brackets /clamps all as specified and directed (the portion of pipe inserted to the masonery /slab shall be fixed with water proofing bathseal tape two way to the entire width of masonry/slab.) . Note:- Pipe are to be fixed away from the wall using suitable clamps and bolts etc. complete all as specified and directed. |
| 83 | S&F in repairs for PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to wall GI brackets /clamps all as specified and directed (the portion of pipe inserted to the masonery /slab shall be fixed with water proofing bathseal tape two way to the entire width of masonry/slab.) . Note:- Pipe are to be fixed away from the wall using suitable clamps and bolts etc. complete all as specified and directed. |
| 84 | S&F Unplasticised PVC pipes preassure rating 10 Kg/sqcm fixed complete to walls,ceiling or laid in floors,bore of pipe in 50mm complete all as specified and directed. |
| 85 | S&F PVC SWR bends 110 mm dia of any radius with access door etc. complete all as specified and directed. |
| 86 | S&F 110 mm dia PVC SWR junction single, (Single T) equal or unequal of any radius with access door etc. complete all as specified and directed. |
| 87 | S&F 75 mm dia PVC SWR junction single, (Single T) equal or unequal of any radius with access door etc. complete all as specified and directed. |
| 88 | S&F PVC (SWR) bends 75 mm dia of any radius with access door etc. complete all as specified and directed. |
| 89 | S&F 75 mm dia PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed. |
| 90 | S&F PVC vent cowl 110 mm dia etc. complete all as specified and directed. |
| 91 | S&F PVC vent cowl 75 mm dia etc. complete all as specified and directed. |
| 92 | S&F 75 mm PVC (SWR) floor trap with grating including jointing with solvent cement complete all as specified and directed. |
| 93 | M&L for sealing and grouting the mouth of all pipes using Fosrocs non shrink grout Conbextra GP2 or equivalent for dia of pipe 110 mm etc complete all as specified and directed. |
| 94 | M&L for sealing and grouting the mouth of all pipes using Fosrocs non shrink grout Conbextra GP2 or equivalent for dia of pipe 75 mm etc complete all as specified and directed. |
| 95 | Taking up or down 20mm dia steel / UPVC pipe tubing and connections, including cleaning for refixing complete all as specified and directed. |
| 96 | Supplying and laying 20 mm (Outer dia) of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 97 | Taking up or down 25 mm dia steel/UPVC pipe tubing and connections, including cleaning for refixing complete all as specified and directed. |
| 98 | Supplying and laying 25mm (Outer dia) of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 99 | Demolition of concrete of any description and in any position (sunken floor) not otherwise specifically provided etc. complete all as specified and directed. |
| 100 | M&L chipping off the disintegrated concrete of sunken slabs and sides and clean the area with wire brush and coir brush. Seal the disturbed area with polymer modified mortar using Fosrocs admixture nitobond SBR latex or equilant. Coving has to be done at all the corners with polymer modified mortar using Fosrocs Nitobond SBR latex or equilant. Seal all the plumbing lines sand holes with Fosrocs non shrink grout Conbextra GP2 or equilant. keep the water on sunken tanks and floors for 24 hrs for observing the leakages and to ensure water tightness. Pressure grouting has to be done at all the damaged areas/ joints with Fosrocs admixture Cabex 100 or equilant. Water proof the area with Fosrocs Acryalic polymer modified water proofing coating, Brush bond RFX or equivalnt in two coats etc. complete all as specified and directed. |
| 101 | M&L plastering (10 mm thick in cm 1:3 mixed with water proofing Compound) the surface and providing a spout with sufficient slope, applying a coat of bituminious primer on the surface @ .20 kg/Sqm, laying 4mm thick, APP modified membrane water proofing membrane weighing not less than 4.0 kg/Sqm reinforced with non woven polyester mat weighing not less than 160 g/sqm having softening point not less than 140 degree centigrade longitudinal tensile strength not less than 800 N/5 cm, tearing strength of 180 N on the surface with 10 cm minium overlap ,Sealing the joints of the membrane using LPG torch complete all as specified and directed.(spout will be measured and paid seperately). |
| 102 | M&L cement concrete in sunken floor, filling and mass concrete 1:4:8 D2 (using 40mm thick stone aggregate) etc. complete all as specified and directed. |
| 103 | S& F Un plasticised PVC Pipes of pressure rating 10 Kg/sqcm fixed complete to walls,ceiling or laid in floors etc bore of pipe in 50mm complete all as specified and directed. |
| 104 | Material & Labour for providing and fixing stainlesssteel (Grade 316) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where everrequired) and fitting the same with necessarystainless steel nuts and bolts complete, includingfixing the railing with necessary accessories &stainless steel dash fasteners, stainless steel boltsetc., of required size, on the top of floor orthe side of waist slab with suitable arrangement complete all as specified and directed. |
| 105 | S&F 4mm thick figured glass,pin head type and glazing with necessary beading area n.exc 0.50 Sqm each pane square/rectangular complete all as specified and directed. |
| 106 | M&L for preparation of new plastered surface of wall and applying two coats acrylic emulsion distemper over a coat of primer over two layers of wall care putty etc. complete all as specified and directed. |
| 107 | M&L for complete removal of existing treatment by scrapping with watering and cleaning old plastered wall surfaces and finishing with two coats of Acrylic emulsion distemper over alkali resistant primer all as specified and as directed. |
| 108 | M&L Prepration of surfaces of ceiling by complete removal of existing treatement and applying two coats of distemper oil emulsion on ceiling over a coat of primer etc. complete all as specified and directed. |
| 109 | Complete removal of existing treatment by scrapping external wall surfaces and Finishing walls with Acrylic Smooth exterior paint of required shade work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) old prepared plastered external surfaces and including scafoldings and cradles including hoisting and lowering as required with bracing , support complete all as specified. Note : Height of the Bldg is approx 10.00 mtrs |
| 110 | Taking down existing water proofing treatment of any thickness from the roof /parapet including cement mortar bedding , PCC tiles, padding concrete if any, upto the RCC slab, removing debris out of the premises and cleaning the roof complete all as specified & directed. |
| 111 | Cutting the V grooves on the terrace slab /wallwhere ever cracks are observed and fill the grooves with Fosrocs heavy duty non shrink grout Convextra GP2 , coving all the 90 degree angles , slab/wall junctions with Conbextra GP2 all as per manufacturer's instruction complete all as specified & directed. |
| 112 | M&L providing a levelling course of cement concrete type B-0, 1:2:4, using 12.50 mm stone aggregate, 40 mm thick maintains a slope towards the drain water pipes by adding a water proof admixture @ 250 ml per bag of cement complete all as specified & directed.Note :-Admixture shall be measured and paid seperately. |
| 113 | M&L for rendering with CM 1:3, 10 mm thick mixed with water proofing admixture of Fosroc/Pidilite or equivalent complete all as specified and directed.Note :-Admixture shall be measured and paid seperately. |
| 114 | M&L for application of water proofing treatement as per the following specification complete all as specified and as directed by Engineer In Charge.(a) Through cleaning work: removal of loose screed,sealing junction of rain water pipe and slab alround and filling with Fosroc Nitofseal PU 40N/PU50N or Bostic PU seal or equivalent mixed as per the ratio recommended by the manufacturer.(b) Providing and laying coving at the junction of slab and vertical parapete wall with cement mortar 1:4 and admixed with Fosroc Nitobond SBR or Bostik Boscocem SBR as per dosage as recommended by the manufacturer.(c) Providing and applying one coat of primer Fosroc Nitop proof WB(water based at ratio 1:2) Bostic Boscocem SBR @ 0.25-0.30 kg/sqm or equvalent on well prepared surface.(d) Once the primer is fully dry,applying a coat of one component Acrylic based modified polyeurothene elastometric solar reflective cum water proof coating Fosroc brush bond Roof guard premium/Bostic Block P 530 BOSCOSEAL PU-D or equvelent by brush or roller(e) Alayer of fiber mesh reinforcement of 45 gms embeded over first coat.(f) Over fibre mesh,applying second coat water proofing coating of Fosroc brush bond roof guard/Bostic Block P530 BOSCOSEAL PU-D or equvalent by brush or roller to fully cover the fibre mesh and make the surface.(g) Water proofing membrane system continued to be applied on the parapet wall up to 300 mm height or as per manufactrer instructions |
| 115 | Dismantling water tanks and removing to store capacity in litrs exc 500 & n.exc 1000 ltrs complete all as specified and directed. |
| 116 | S&F Rotational moulded polyethylene water storage tanks 1000 ltres capacity (cylindrical vertical with closed top) hoisted and fixed in position all asspecified in SSR Part complete all as specified and directed. |
| 117 | S&F Ball brass valves, high pressure,with polythene float and flynut complete,screwed for ironpipe or brass ferrule and fixed bore of tube in 25 m complete all as specified and directed. |
| 118 | S&F Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed Bore of pipe in 25 mm dia complete all as specified and directed. |
| 119 | Taking down aluminium window/ventilator any size any type complete all as specified and directed. |
| 120 | ROAD/ PATH/ HARDSTANDING |
| 121 | Demollition of Cement concrete (unreinforced) n exc 15 cm thickness (below or above ground floors) complete all as specified and directed .. |
| 122 | M&L 60mm thick Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 , M-35 Grade complete all as specified and directed . Note : Colour and pattern and size to be approved by GE. |
| 123 | M&L 50 mm thick cushion of coarse aggregate of size 6.3 mm and below, spread, rammed and levelled to receive paver blocks complete all as specified and as directed. |
| 124 | M&L for PCC 75mm thick 1:4:8 type D2 (usng 40 mm graded crushed stone aggregate) as in sub base lean concrete complete all as specified and as directed. |
| 125 | M&L for PCC 1:2:4 type B0 (usng 12.50 mm graded crushed stone aggregate) as in kerbs, coving, coping mud stops ,rounded or chamfered on edges complete all as specified and as directed. |
| 126 | EXTERNAL WATER SUPPLY |
| 127 | Excavation in trenches n. exc. 1.5 M wide and n. exc. 1.5M in depth and getting out in soft and loose soil for laying of pipes complete all as specified and as directed |
| 128 | Returning, filling in including spreading,levelling watering and well ramming in layers not excluding 25 cms in any type of soil complete all as specified and as directed |
| 129 | Removing excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and as directed |
| 130 | Taking up or down steel tubing/CI/DI/CPVC any type of pipes and connections of size 25 mm dia ,including cleaning for re fixing,removal to store or credit to contractor complete all as specified and as directed. |
| 131 | Taking up or down steel tubing/CI/DI/CPVC any type of pipes and connections of size 50 mm dia ,including cleaning for re fixing,removal to store or credit to contractor complete all as specified and as directed. |
| 132 | S&F CPVC pipes, SDR 11, 50 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow ,Tee, bends, unions ,sockets ,Threaded Adoptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and as directed. Note:- Excavation and earth work,PCC for road crossing shall be measured and paid separately |
| 133 | S&F CPVC pipes, SDR 11, 25 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow ,Tee, bends, unions ,sockets ,Threaded Adoptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and as directed. Note:- Excavation and earth work,PCC for road crossing shall be measured and paid separately |
| 134 | M&L for cutting/dismantling of bitumin road/RCC floor etc for laying / passing under ground pipes up to 30cm depth complete all as specified and as directed. |
| 135 | M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregate 100mm thick in cutted/dismantled portion of road and making good after laying/passing the pipes complete all as specified & directed. |
| 136 | Dismantling existing unserviceable gate / globe valves fitted with iron pipes for replacement of size 25 mm dia complete all as specified & directed. |
| 137 | Dismantling existing unserviceable gate / globe valves fitted with iron pipes for replacement of size 50 mm dia complete all as specified & directed. |
| 138 | supply and fix in repair gun metal gate valve 25 mm dia with iron wheel head screwed both ends for iron pipe fixed complete all as specified & directed. |
| 139 | supply and fix in repair gun metal gate valve 50 mm dia with iron wheel head screwed both ends for iron pipe fixed complete all as specified & directed. |
| 140 | Dismantling the damage valve pit chamber of the internal size 60cmx60cmx60cm and reconstruction the same with sub class ‘B’ bricks in cement mortar 1:6, brick masonry , rendering 10mm thick on brick and 3.15 mm thick mild steel sheet cover with MS angle iron frame of size 40mmx40mmx6mm thick with locking arrangement and open able handle, Incl painting of two coats of synthetic enamel paint over one coat of red oxide primer.for valve pit cover complete all as specified and directed by Eng -in-charge. |
| 141 | EXTERNAL ELECTRIC SUPPLY |
| 142 | Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and making good Bottom surface for laying /removing of cable, erection of poles in Soft loose soil all as specified and directed by engr in charge |
| 143 | M & L Removing excavated soil to a distance not exceeding 50 meter and not exceeding 1.5 meter above the starting point, and depositing where directed complete all as specified. |
| 144 | M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and Above sand shall be obtained through digging at site 500 mtrs distance and transporting to site for punned use to sand cushioning upto 18Cm thickness, complete all as specified and as directed |
| 145 | Material and labour for burnt bricks subclass B laid in trenches for cable protection all as specified and directed |
| 146 | Returning filling in excavated soil in trenches, watering and well ramming in layers n exc 25 cm complete all as specified. |
| 147 | Taking out UNSV UG cables of any sizes from trenches/walls incl all mounting accessories and GI tubing and Issued under schedule of credit including making good to disturbed areas complete all as specified and as directed |
| 148 | Taking down unserviceable LT panel of any type from existing position after disconnection of electric connection & temporary restoration of normal electric supply till final installation of LT panel including making good disturbed surfaces if floor/walls etc complete as directed by Eng-in-Charge. |
| 149 | M&L XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 70 sqmm 3.5 core , 1100 volt grade ,Heavy grade conforming to IS :7098 (Part 1) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed with stranded aluminium conductor of size laid in trenches,ducts etc all as specified.and directed. |
| 150 | M&L XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 95 sqmm 3.5 core , 1100 volt grade ,Heavy grade conforming to IS :7098 (Part 1) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed. with stranded aluminium conductor of size laid in trenches,ducts etc all as specified and directed. |
| 151 | M&L XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 10 sqmm 4.0 core , 1100 volt grade ,Heavy grade conforming to IS :7098 (Part 2) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed. with stranded aluminium conductor of size laid in trenches,ducts etc all as specified.and directed. |
| 152 | M&L for scrabbing and cleaning the existing electric meter panel board complete and applying two coats of Enamal painting incl one coat of primer painting by using spray paint incl taking down existing energy meters of 10/12 Nos and refixing complete incl necessary wiring circuit between meter and MCB DB VTPN with 06 Sqmm copper conductor PVC insulated and unsheathed FRLS cable , attend any minor repairs like hinges welding etc compler all as per direction of Engr in charge |
| 153 | Material & labour for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in Set ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6mm mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel Gl protection pipe 15mm bore light grade all as shown in electrical plate No 3 on serial page No 497 of SSR part 2009 and connected to main switch board / Main DB's including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, Gl pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed. |
| 154 | Supply, installation, commissioning and testing LT Panel Board of minimum size 2.0 m (height) x 2.0 m (breath) x 0.40m (depth) ,3.0 mm thick, factory made CPRI approved panel, weather, dust & vermin proof OUTdoor, double door, front openable, and made Lt panel through Stainless steel sheet compartmentalized design including stainless steel channel frame, and ISMC 75 at the base of panel only for grouted wiht PCC using 20 mm graded stone aggregate, duly providing rubber/ PVC gasket of suitable size all sides of door, with alluminium busbar 800 AMPscapacity wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB output of suitable length including aluminium bus bar of suitable size for neutral for connection of cable from main busbar, made out of 3.00 mm thick stainless steel steel with suitable size angle iron supporting frame including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 6 sqmm copper wire and connections of all outgoing / incoming electrical cable connecetions with new lugs, glands to be provided at cable entries, including angle iron support 50x50x6 mm angering with 75 CM height from ground level at the base of panel . The panel shall be comprising of following accessories,complete all as directed by Engineer-in-Charge. |
| 155 | INCOMMING(a) MCCB, 4 Pole 415 Volts, 50Hz 400 Amps, 36 kA, thermal magnetic release, Ics =100% Icu, front face isolation with positive break indication with double break contacts with spreader and phase barrier - 01 No(b) Multi function digital energy meter with RS 485 communication port with CTs(c) Phase Indicator lamp assy RYB - 01 Set.(d) CT Coils of suitable ratio-01 Set.OUTGOING:- (a) MCCB, 4 Pole 415 Volts, 50Hz, 125 Amps, 26 kA, thermal magnetic release, Ics =100% Icu, front face isolation with positive break indication with double break contacts with spreader and phase barrier - 04 Each(b) MCCB, 4 Pole 415 Volts, 50Hz, 63 Amps, 26 kA, thermal magnetic release, Ics =100% Icu, front face isolation with positive break indication with double break contacts with spreader and phase barrier - 02 Each(c) MCB, single pole & neutral, up to 32 Amps, with DBs, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed -0 2 Nos (d) Automatic single dial time switch panel mounted flush to panel door, 230V AC quartz time base,with one selector switch for auto/manual selection Part No 15336,Type IH24h Make- Schneider/L&T/Legrand – 01 No.(bldg Security light) |
| 156 | LIGHTNING ARRESTOR |
| 157 | Taking down aluminium/GI/copper strip of upto 32 x 6 mm from the inspection box to the earth pit//roof conductors/down conductors and disconnecting insulators from the multi stories buildings/structures/over head tanks etc including porcelain insulators, complete all as specified and as directed |
| 158 | Taking down the inspection box of any size, jointing togather copper/aluminium /GI strip with all accessories complete all as specified and as directed |
| 159 | Taking down earth with electrode/plate complete all as specified and as directed |
| 160 | Taking down air termination aluminium single pointed rod 12mm dia, 300 mm long.complete all as specified and as dircted |
| 161 | Taking down GI tubing medium grade 40 mm including dismantling PCC base/clamps complete all as specified and as directed |
| 162 | Supply and fix air termination, single pointed, Aluminium rod 12 mm dia and 300 mm long complete all as specified and as directed. |
| 163 | M/L for test point terminal block made of gun metal or phosphorus bronze size 75 x75 x 25 mm drilled & screwed including 3 Nos 8mm dia 25 mm long hex. Head screw complete all as specified and as directed |
| 164 | M/L for Aluminium strip 25 x 3.15 mm fixed on wall by using porcelain insulated clamps with connecting to roof conductor/slove conductor/test point etc complete all as specified. |
| 165 | M/L for GI strip 32 X 6 mm mm fixed on wall/floor by using porcelain insulated clamps with connecting to wall conductor/slove conductor/test point.etc complete all as specified |
| 166 | S&F junction box made of HDPE material having IP 65 protection heavy duty water proof ,weather proof for outdoor installation of size 205mm x255mm x112mm fixed with Test point terminal block made of gun metal or phosphorus bronze size 75 x75 x 25 mm with holes ,nuts bolts,washers all specified and as directed by Engr- in -charge. |
| 167 | M&L in repair for earthing complete with galvanized steel earth plate 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanized iron strip size 32x6mm as earthing lead by means of bolt ,nuts, check nuts and washer of galvanized iron or steel besides welding of all joints as shown in drawing and including excavation and earth work, G.I.pipe light grade 40 mm bore for protection of G.I.strip from earth electrode to and including the earth test point of galvanised iron /steel of size 75 x75x 25 mm , supplying and laying charcoal dust, common salt PCC 1:2:4 type B-I using 20 mm stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round ,PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed . Note :- Cost of earthing strip & GI pipe 40mm up to 7.5 m shall be included in cost of above item. |
| 168 | Supplying and laying in repairs incl taking down old GI tubing light grade of size 40 mm dia incl all accessories for encasing cables for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works all as specified and directed:- (MS works will be measured under seperate item in Schedule) |
| 169 | AVIATION LIGHT |
| 170 | Supply and fix replacement of integral LED Aviation Obstruction light comprising of aluminium housing with polycarbonate enclosure along with programmable digital time switch and one MCB SP AC 240 VOLTS OF 06 Amps fixed in a wall bracket enclosures complete all as specified and directed . |
| 171 | M&L and replacement of XLPE Insulated, PVC Sheathed, Armoured with Multi-stranded Aluminium Conductor Cable having Cross-sectional area 6 Sqmm, 2 Core, 1100 Volt grade, Heavy Duty, conforming to IS:7098 (Part-1), laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, walls etc., complete all as specified and as directed. |
| 172 | INTERNAL ELECTRIC SUPPLY |
| 173 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete fittings such as switches, ceiling roses, pendants regulators sockets lights and complete fitting removing materials from site taken as credit and making good the disturbed surfaces complete all as specified and as directed |
| 174 | Taking down of submain wiring of any size along with conduit and its accessories complete all as specified and as directed |
| 175 | Taking down of DB of any size with MCB all as specified and as directed |
| 176 | M & L for point wiring in and including rigid non metallic PVC casing and caping using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded coppper conductor 1.5 Sqmm nominal cross sectional area, single core, PVC insulated unsheathed stranded copper conductor cable, 1100 volts grade with concealed metal boxes and modular white cover plate and frame of suitable size(same make of approved switch and socket) including PVC insulated & unsheathed multi stranded copper condutor of 1.5 Sqmm nominal cross sectional area, single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly wire complete for the following :- |
| 177 | One light point controlled by one switch. |
| 178 | One Exh. Fan controlled by one switch |
| 179 | One Ceiling fan point by one switch and regulator |
| 180 | One 5 Amps socket outlet point on same board alongwith other switch. |
| 181 | One 5 Amps socket outlet point on independent board controlled by one switch. |
| 182 | One light point controlled by two way switch |
| 183 | One bell point controlled by one switch |
| 184 | M & L for point wiring in and including rigid non metallic PVC casing and caping using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded coppper conductor 4 Sqmm nominal cross sectional area, single core, PVC insulated unsheathed stranded copper conductor cable, 1100 volts grade with concealed metal boxes and modular white cover plateand frame of suitable size (same make of approved switch and socket) including PVC insulated & unsheathed multi stranded copper condutor of 4 Sqmm nominal cross sectional area, single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly wire complete for 15 A socket independent. |
| 185 | S & F in repair for Modular Switch piano flush type, single pole, 1 way, 6 Amp, 1 module complete all as specified. . |
| 186 | S & F in repair for Modular Switch piano flush type, single pole, 2 way, 6 Amp,1 module complete all as specified. |
| 187 | Supply and fix in repair modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified |
| 188 | S & F in repair for Modular Switch piano flush type, single pole, 1 way, 16 Amp, 1 module complete all as specified. |
| 189 | Supply and fix in repair modular Socket, 6A/16A - 2/3 pin combined 2 module, complete all as specified |
| 190 | S&F in repair Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed. |
| 191 | Supply and fix in repair modular Bell push, flush type, 6 Amps complete all as specified and directed |
| 192 | Supply and fix in repair ceiling rose PVC , isolated body with two to three terminals 230 V (ISI marked) surface bakelite complete all as specified and directed. |
| 193 | S & F in repair Modular fan regulator step type AC, 120 W two module complete all as specified & directed |
| 194 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed |
| 195 | Supply and fixing LED lights 2 feet fitting 1x 10W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible Copper conductor cable of suitable size from ceiling rose complete all as specified & directed |
| 196 | Supply and fixing LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket of suitable dia upto 1.5 m length & necessary arrangements to fix it on wall/building with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed |
| 197 | M&L Sub main wiring with 2 runs of 6 sq mm single core, multistranded PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn in and including PVC Casing and caping of suitable size and accessories fixed on the wall/roof/floor with one run of 6sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dully all as specified. (Two single cable run, earth wire and casing will be measured as one unit length). |
| 198 | M&L Sub main wiring with 2 runs of 4 sq mm single core, multistranded PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn in and including PVC Casing and caping of suitable size and accessories fixed on the wall/roof/floor with one run of 4 sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dully all as specified. (Two single cable run, earth wire and casing will be measured as one unit length). |
| 199 | Disconnection of electrical wire from ceiling fan any type / size and make, dismantling the ceiling fan, wahsing and removing of old lubricating substance from bearing/bush using Kerosine oil, painting ,carrying out fresh lubrication using grease and to make free for smooth functioning, including replacement of worn out/unserviceable spares as required, replacement of PVC insulated, unsheathed stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 1.0 M long, assembling the repaired ceiling fan and testing to the entire satisfication of engineer in charge and hanging at position with nut , bolts washers etc, connection with point wiring & testing complete. (Replacement of Spares flexible wire etc/rewinding of Ceiling fan/shall be measured and paid seperately under respective item for material and labour cost .) |
| 200 | Material and labour for rewinding of ceiling fan 1200/1400 MM sweep by dismantling of fan motor, cutting and removing of burnt windings, cleaning the motor slots, rewinding the motor with supper enameled copper wire of appropriate gauge, provision of insulation paper, applying of varnish, heating / baking the motor to acheive the proper insulation resistance and reassembling and refixing the fan in original location complete all as directed. |
| 201 | Disconnection of electrical wire from exhaust fan and taking down exhaust fan of any type/size, make moreover dismantling the exhaust Fan for removing of old lubricating substatance from bearing/bush & applying fresh lubrication using grease to avoid noise free smooth functioning, including replacement of worn out/unserviceable spares as required and replacement of PVC insulated, unsheathed multi stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 0.5 M long incl testing the repaird exhaust fan to the entire satisfication of engineer in charge and refixing the fan in own position with provision of hanging bush, cotter pins, nut , bolts washers etc complete all as directed.. (Note : rewinding of exhaust fan and PVC wire fro making connection shall be measured and paid seperately under respective item .) |
| 202 | Rewinding of exhaust fan 300/380 mm sweep 230 volts , of any make/type a with super enamelled copper wire of appropriate gauge and number of turns as existing to obtain the specified and satisfactory RPM as per menufactures specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stater/rotor, connection & testing complete. Note : exhaust fan before fix at site RPM should be checked and match as per manufactures specification till entire satification of Engr in charge |
| 203 | Supply and fix in repair of sheet metal enclosure distribution board, triple pole and neutral, vertical type, AC, 415 volt, 04 way with 200 Amp rated copper bus bar and double door complete all as specified & directed and comprising of the following : (a) MCCB 63 Amp 04 pole AC 415 V of 16 KA breaking capacity -01 No(b) MCB SP AC 240 volt of upto 40 Amp capacity complete - 12 No |
| 204 | S&F in repairs 240V SPN distribution board factory made double door flush type all as per IS 8623 made from sheet metal duly powder coated 12 way to be fixed flush with wall complete with all accessories all as specified and directed by Engineer-in-Charge. |
| 205 | S&F in repairs MCB SP 6 to 32 Amp, 240 volts of 10 KA rupturing capacity, B-curve type including taking down of existing unserviceable complete all as specified. |
| 206 | S&F in repairs MCB SP 40 Amp, 240 volts of 10 KA rupturing capacity, C-curve type including taking down of existing unserviceable complete all as specified. |
| 207 | M&L for painting on old surfaces LT panels/iron structure by spray paint after cleaning strains and grease/oil spots with sand paper & thinner and painting the cleaned surface with synthetic enamel paint of existing colour to achieve good finish by applying two coats of paints complete all as specified and as directed |
| 208 | Material & labour for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in Set ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel Gl protection pipe 15mm bore light grade all as shown in electrical plate No 3 on serial page No 497 of SSR part 2009 and connected to main switch board / Main DB's including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, Gl pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender