Tender For Provison Of Solar Rooftop Panels At Admin Block, Cgdhq-10, C Bell Bay
Tender Value
43.63 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
16 days left
EMD
87300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nicobars → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provison Of Solar Rooftop Panels At Admin Block, Cgdhq-10, C Bell Bay
BOQ
| Sl. No. | Item Description |
| 1 | Supply, delivery, installation of Solar Mono Crystalline Bifacial PV: >= 605Wp IEC 61215 : 2016, IEC 61730 : 2016, IEC 61701, IEC 62716, IEC 60068-2- 68, IEC 62804 including supply of all necessary accessories, etc complete in all Respect as per specification laid down else where in the tender and as per direction and satisfaction of Engineer In - Charge. |
| 2 | Supplying, fiting & fixing of 25 KVa ( 10 + 10+ 5) Semi Hybrid connected String Inverter for Solar use along with all accessories.Max. input voltage:180-440 V No. of MPPTs: 6 (2 per Inverter)Max. number of PV strings per MPPT: 1, AC voltage range: 127V/220VNominal grid frequency: 50 Hz / 60 HzPower factor: > 0.99 @default value at nominal power, (adj. 0.8 leading - 0.8lagging)Over Voltage Category: OVC II(DC),OVC III(AC) |
| 3 | Supplying, fiting & fixing of 12 volt 200 AH battery for Solar use (As per Inverter Capacity) along with all accessories. |
| 4 | Supplying, fiting & fixing of conventional type Lightening Arrestors along with all accessories. |
| 5 | Supplying, fitting & fixing of PV Module Mounting Hot Dip Galvanized Module Mounting Structures with 80 micron Galvanization Thickness GI Structure (Sheet Metal) consisting of mainly Angle material and accessories, capable of withstanding 180 km / hr. wind speed, Design Factor for safety 1.5 as recommended by PV manufacturer & as directed by Engineer In - Charge. |
| 6 | Supplying, fitting & fixing of Array Junction Boxes, DC Junction Box with Glass fuse and DC SPD, complete in all respect as per specification laid down else where in the tender and as per direction and satisfaction of Engineer In - Charge. |
| 7 | Supplying, fitting & fixing of Inverter / ACDB canopy/kisok with stand & fitting accessories complete in all Respect as per specification laid down and as per direction and satisfaction of Engineer In - Charge. |
| 8 | Supplying & Installation of IIP/MCCB box with suitable rating, MCCB indicators, required for development of existing feeder as per site requirement complete in all Respect as per specification laid down and as per direction and satisfaction of Engineer In - Charge. |
| 9 | Supplying, fitting - fixing of ACDB/GIP as per specification & approved SLD ,IP 65 suitable for outdoor installation complete in all Respect as per specification laid down else where in the tender and as per direction and satisfaction of Engineer In - Charge. |
| 10 | Suppling & Installation of LT Solar Energy Generation meter complete in all Respect as per specification laid down else where in the tender and as per direction and satisfaction of Engineer In - Charge. |
| 11 | Supplying, Laying of Single core 6 Sq. mm (Black) , (Black with red strip) Unarmoured copper Solar Grade DC Cables & AC Cable 4 core 10 sq. mm. Aluminium, Armoured, complete in all Respect as per specification laid down else where in the tender and as per direction and satisfaction of Engineer In -Charge. |
| 12 | Supplying, Laying of 1.1KV, Flexible Copper Conductor FR PVC - 1C X 10 sqmm. insulated Unarmoured and Unsheathed Cable as per IS 694/695 complete in all Respect as per specification laid down else where in the tender and as per direction and satisfaction of Engineer In - Charge. |
| 13 | Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt.long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts.below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode |
| 14 | Supplying & Laying of HDPE DWC Pipe PE-63, PN- 4KG DN 32 MM Black for DC cable,communication cable. |
| 15 | Supplying, Fitting-Fixing of Hot Dip Galvanised Perforated Cable Tray With Cover - DC Cable Routing & ACDB Cable Dressing HDG with 80 micron. |
| 16 | Supplying, Fitting-Fixing of Hot Dip Galvanised Perforated Cable Tray With Cover - AC cable HDG. |
| 17 | Supplying, Fitting -Fixing of Nylon Cable Tie, UV Resistant - 250mm. |
| 18 | Supplying, fitting - fixing of 15A, 1000 Vdc - 4 sqmm,UV resistant (male & female). |
| 19 | Supplying, fitting - fixing of Cu, Al & Bimetallic - Ring Type Lugs, appropriate size of cable. |
| 20 | Supplying, fitting-fixing of Cable Glands As per SLD & Supplied Cable. |
| 21 | Supplying, fitting - fixing of Pre Printed - 1 To 9 & A to Z Ferrules. |
| 22 | Supplying, Fitting- fixing of Danger boards should be provided as and where necessary as per IE Act./IE rules as amended up to date and as per instruction of EIC. |
| 23 | Supplying Fitting - Fixing of Fire Extinguishers 9kg DCP type nearby power evacuation panel with Sand Bucket including supply of all necessary accessories, etc complete in all Respect as per direction and satisfaction of Engineer In - Charge. |
| 24 | Supplying, fitting - fixing of Pressure Controlled HDPE Water Piping network for Module cleaning with joints and valves and booster pump, High Pressure Air jet system and including supply of all necessary accessories, etc complete in all Respect as per direction and satisfaction of Engineer In - Charge. |
| 25 | M& L for Crimping Paste, Bitumin Paint, Silver paint, Electrical Tap, heat sleevee, Lugs, Glands, Saddles, Nut Bolt & Washer Set, rubber mat as per IS etc complete in all Respect as per direction and satisfaction of Engineer In -Charge. Confirming 25 kWp. |
| 26 | Supplying, Fitting- Fixing of Remote Monitoring System and Data Loger as following parameters should be accessible via the operating interface display in real time separately for Project:a) AC Voltage,b) AC Output current,c) Output Power,d) Power factor,e) DC Input Voltage,f) DC Input Current,g) Time Active,h) Time disabled,i) Time Idle,j) Power produced,k) Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault, PV starting voltage, PV stopping voltage including GPRS/Internet + SMPS with Antenna with Accessories complete in all Respect as per specification laid down else where in the tender and as per direction and satisfaction of Engineer In - Charge. Confirming 90 kWp. alongwith following items Supplying Fitting- fixing of Weather Sensor for -i) Irradiation sensor - 1No.ii) Ambient temp sensor - 1No.iii) Module Temp Sensor - 1No.The system must be compatible with the Inverter for remotely monitoring of the data. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysOct 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender