Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #57415686

Tender For Provn Of B/R Works Services In Certain Otm Bldgs At Rva Area, Provn Of Galvalume Sheet Shed In Omq And Provn Of Interlocking Tiles In Certain Omq At Af Stn Palam Under Ge Af Palam, Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
33.94 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
0 days left
EMD
67900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of B/R Works Services In Certain Otm Bldgs At Rva Area, Provn Of Galvalume Sheet Shed In Omq And Provn Of Interlocking Tiles In Certain Omq At Af Stn Palam Under Ge Af Palam, Delhi Cantt-10

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 19-Sep-2026 CORRIGENDUM NO 1 BOQ 01-Oct-2026
2 19-Sep-2026 CORRIGENDUM NO 1 Date 01-Oct-2026

BOQ

Name of Work:- PROVN OF B/R WORKS SERVICES IN CERTAIN OTM BLDGS AT RVA AREA, PROVN OF GALVALUME SHEET SHED IN OMQ AND PROVN OF INTERLOCKING TILES IN CERTAIN OMQ AT AF STN PALAM UNDER GE AF PALAM, DELHI CANTT-10
Sl. No. Item Description
1Surface excavation n. exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
2Removing excavated material soils n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. Note:- The Contractor shall remove debris /soil and to drop outside the MoD land.
3Demolition of cement concrete (un reinforced) in ground floors and pavings n. exc 15cm thickness (below or above ground level) complete all as specified and as directed. Note:- The Contractor shall remove debris /soil and to drop outside the MoD land.
4Taking down cement plaster on brick or concrete wall surfaces etc including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and as directed.
5M&L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete complete all as specified and as directed.
6M&L for 10mm thick rendering of Ready mix plaster of approved make on brick/ concrete surfaces on internal walls, surfaces even and fair as per manufacturer's instructions, including necessary scaffolding complete all as specified and as directed.
7M&L for 15 mm thick rendering of Ready mix plaster of approved make on brick/ concrete surfaces on external walls, fascia, parapet and chajjas finished the surfaces even and fair including water proofing compound by weight as per manufacturer's instructions, including necessary scaffolding up to (G+3 storey) complete all as specified and as directed.
8M&L for 25mm thick cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in floor etc complete all as specified and as directed.
9M&L for vitrified tiles light shade 8 to 10mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
10Description all as per ser item no 9 above but as in vertical surface of wall, skirting with and including 10mm thick rendering of CM (1:4) complete all as specified and as directed.
11M&L for vitrified tiles light shade 8 to 10 mm thick (square/ rectangular) polished, area of each tile exceeding 0.42 sqm and not exc 1.00sqm each as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
12M&L for machine cut Kota stone slab 20 to 25 mm thick laid and jointed with grey cement slurry and pointed with coloured cement to match the shade of the slab including rubbing and mirror polishing complete over and including 20mm thick screed bed in CM (1:4) complete all as specified and as directed.
13M&L for machine cut Kota stone slab 20 to 25 mm thick as in steps, skirting, dado and piller laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete and including 15mm thick rendering CM 1:4 all as specified & directed.
14M&L Matte/ ceramic glazed tiles 8 to 10mm thick in vertical surface of any shape, area of each tile not exc 0.18 sqm each set and jointed in neat cement slurry and pointed in white or colour cement to match and including 10 mm thick rendering CM 1: 4 as on vertical surfaces complete all as specified and directed.
15M&L Matte/ ceramic glazed tiles in vertical surface area of each tile exceeding 0.42 sqm and not exc 1.00sqm each 8 to 10mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and including 10 mm thick rendering CM 1: 4 as on vertical surfaces complete all as specified and directed.
16M&L 18 to 20mm thick Granite (jet black) work (table rubbed and polished) as in steps, jambs, pillars, window cills, cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. Note:- The cost of exposed edges to make half round shall be deemed to be included in unit rate.
17Excavation in post holes each not exceeding 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with around earth in layers not exceeding 25 cm thick, watering and removing surplus spoil to a distance not exceeding 50 m and making good surface all as specified and as directed.
18M&L PCC in foundations, filling and mass-concrete type C2 (1:3:6) using 40 mm graded stone aggregate
19S&F steel work in tubular/square/rectangular hollow section/angle iron, tee etc. for trusses/ purlins & rafter including special shaped washer etc. complete using ERW or induction butt welded tubes using Fe as per IS 4923, Grade YST 310 including necessary machinery for upto 10m height structure complete in all respect as specified and directed.
20M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars.
21S & F 35/40 mm thick puf panel typically features a core of rigid polyurethane form with an average density of approximate 40 kg/m and a thermal conductivity of about 0.023 to 0.03 W/mk. The panel is enclosed by outer and inner skins, often made of 0.50mm thick pre-painted galvanised iron ( PPGI) sheet of any colour and fixed in roof covering/cladding to wall, fixed with self tapping screws complte all as specified.
22S & F 0.50mm thick Pre-painted galvalume aluminium Zinc coating steel GI based corrugated sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall , fixed with self taping screws as specified.
23M & L for 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in floor etc complete all as specified
24M&L coloured Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set jointed and pointed in neat cement slurry in floor over 20mm scread bed in cement mortar 1:6 all as specified.
25M&L heavy duty digital parking tiles 30cm x 30cm x 8 to 10mm /400 cm x 400 cm x 8 to 10 mm thick ,set jointed and pointed in neat cement slurry in floor over 20mm scread bed in cement mortar 1:6 all as specified.
26M&L for PCC 1:2:4 type B1 (20mm graded aggregate) as in kerbs or mud stops, rounded or chamfered edges, etc
27S&F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
28M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior emulsion paint over one coat of primer over 2mm thick (avg thickness) wall care putty complete all as specified.
29M&L for complete removal of existing treatment of old decorated external surface of walls by electrically operated grinder including necessary scaffolding complete and applying two coats of exterior emulsion paint over a coat of primer of same brand over 2mm thick (avg thickness) wall care putty to obtain even and smooth surfaces including preparation of surfaces.
30M&L for preparing New plastered surfaces and applying two coats of distemper oil emulsion on wall surfaces including primer complete all as specified and as directed.
31M&L for complete removal of existing treatment of old plastered surfaces on walls including brooming down or steel wire brushing, scraping down and applying two coats of distemper oil emulsion over one coat of alkalic resistent primer complete all as specified .
32Preparation of new steel and iron surface of any description over 10cm in width or girth and applying 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
33M&L for factory made precast cement concrete kerbs stone of PCC 1:2:4 type B-0 using 12.5MM graded crushed stone aggregate of any shape and size including chamfered angles, weathering or singly round throating etc including setting and jointing in cement mortar 1:4, including necessary formwork complete all as specified and directed.
34M&L for Machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment, confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade glossy finish Iincluding 25mm thick sand cusioning as per the direction of Engineer-in-Charge.
35M&L for applying two coat of synthetic enamel paint on concrete surfaces of any description over 10cm girth or width over a coat of primer including necessary preparation, all as directed by Engr in Charge.
36Taking down Chowkats or frames with shutters not exceeding 1.5 Sqm each (Without taking off shutters from the frames)
37Taking down Chowkats or frames with shutters exceeding 1.5 Sq. M but not exceeding 4 Sq. M each (Without taking off shutters from the frame)
38S&F for Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
39S & F of power coated aluminium window and ventlator shutters side hings, aluminium section weighing 0.55 kg/m including necessary joining cleats,gauge/ glazing cips rubber packing anodised aluminium snap beading screws anodised aluminium fittings all as specified and directed.
40S&F aluminium powder coated three track sliding window with mosquito net two track for glass leaf sliding and one track for mesh leaf sliding outer frame weighing 0.699 Kg/m,75x26 mm size equvalent Jindal model 20671, shutter plain of size 37.5x15mm weighing 0.366 Kg/m, Section No 20690 Jindal), with powder coating of min thickness 50 micron with one or more rebates, sliding type without sash bars, 5mm thickness double tampered clear glass , rubber packing, snap beading screws,with horizontal sliding type with stainless steel mesh, frame, powder coated aluminium grill type AL 925 or equvalent grill, cutting in suitable size and fitting with screws and suitable beedings to aluminum window frame complete etc. complete all as specified.
41S&F anodised aluminium powder coated door shutter, aluminium section wt 0.55 Kg/m including neccesary joining cleats, glazing clips,rubber neoprene packing, handle 2 nos in each door, hinges, anodised aluminium snap beading screw etc. complete all as specified.
42S&F 5.50mm thick tinted , sheet glass of selected quality fixed to aluminium frame work complete.
43Supply and fixing of 12mm thick Gypsum board suspended Ceiling system of any shape and size (India gypsum make) with ISI grade GI framing of intermediate channel 15X45X15X0.9mm, perimeter channel and ceiling angle 25X10mm section with connecting clip 2.64mm dia including all hardware i.e soffit cleat,rawl plug,edge bead,angle bead,nut &bolt drywall screws, hangers etc with all hanging accessories, cut out to made for lighting, fixture and AC grills, including POP/ putty and two coat of oil bound distemper complete all as specified and directed.
44S&F 'E' board ceiling 4mm thick with GI framed work with main tee of size 24mm x 28.5mm made out of PGI sheet 0.3mm thick doubled at web and single at flange. Flanage covered with powder coated sheet 0.35mm thick and wail angles 24mm x 24mm x 0.3mm powder coated for ceiling, ceiling board 60cmx60cmx4.00mm thick, suspended with GI wire 2.24 mm dias and length as required @ 600mm C/C with adjustable device complete including plugging in brick/concrete work with steel raw plug @ 600 mm C/C and applying two coats of OBD over a coat of primer on ceiling board. Ceiling board shall be pressed to the ceiling tee with staple clips at all four sides all as specifed and directed including making good all the disturbed portion complete all as specified and directed.
45S&F in replacement of AMF Controller Module suitable for existing DG Set AMF Panel of DG set upto 630 KVA complete with programming, testing and commissioning complete all as specified nd as directed.
46S&F in replacement of Timer Module/Engine Start-Stop Timer suitable for existing AMF Panel of DG set upto 630 KVA, complete with testing and commissioning.
47S&F in replacement of Digital Metering Package comprising voltmeter, ammeter, frequency meter, selector switch and associated wiring, suitable for existing DG Set AMF Panel of DG set upto 630 KVA complete with testing and commissioning complete all as specified nd as directed.
48S&F in replacement of complete Internal Control Wiring Harness including FRLS copper multistrand wiring, ferrules, lugs, cable ties, PVC channels and terminations, suitable for existing DG Set AMF Panel of DG set upto 630 KVA complete with testing and commissioning complete all as specified nd as directed.
49S&F in replacement of Indication Lamp and Push Button Set, suitable for existing DG Set AMF Panel of DG set upto 630 KVA, complete with testing and commissioning complete all as specified nd as directed.
50S&F in replacement of Relay and Protection Module Set, suitable for existing DG Set AMF Panel of DG set upto 630 KVA complete with testing and commissioning complete all as specified nd as directed.
51S&F in replacement of Terminal Block Assembly, suitable for existing DG Set AMF Panel of DG set upto 630 KVA complete with ferruling, numbering, testing and commissioning complete all as specified nd as directed.
52Repair/servicing of APFC Panel of capacity upto 350 KVAR installed at Tech Power House for maintaining Power factor including connecting to existing control wiring system and testing for functioning the capacitor panel as per load complete including by replacing the existing unserviceable connected items like indicator/ampmeter/voltmeter/PF meter etc complete without any extra cost complete all as specified nd as directed. Note:- Capacitor shall be measured and paid separately.
53S&F in replacement of matalised poly propylene heavy duty capacitor cell for 3 phase 440/415 volts 50Hz system of capacity of 5 KVAR. Make:- Neptune, L&T, Epcos
54S&F in replacement of matalised poly propylene heavy duty capacitor cell for 3 phase 440/415 volts 50Hz system of capacity of 10 KVAR. Make- Neptune, L&T, Epcos
55S&F in replacement of matalised poly propylene heavy duty capacitor cell for 3 phase 440/415 volts 50Hz system of capacity of 15 KVAR complete all as specified nd as directed. Make:- Neptune, L&T, Epcos
56S&F in replacement of matalised poly propylene heavy duty capacitor cell for 3 phase 440/415 volts 50Hz system of capacity of 25 KVAR complete all as specified nd as directed. Make:- Neptune, L&T, Epcos
57Supply and fixing ceiling fans complete with blades, down rods, modular electronic regulator and accessories, 230 V, 1200mm sweep or 48\\". Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), including connecting up with three core flexible copper conductor cable of suitable size from ceiling, complete all as specified as directed. Make:- Havells/Usha/Cromption/Bajaj or equivalent as per list of makes.
58M&L for Submain wiring alongwith earth wire of size 4x2.50 sq. mm + 2x2.50 sq. mm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor, single core cable drawn in and including PVC concealed conduit ISI marked, medium grade of adequate size with all conduit accessories medium grade ISI marked as required as specified and as directed. Note :- (i) Four run of PVC wire and two run of earth wire, 1 run of conduit shall be measured as one length.
59M&L for Submain wiring alongwith earth wire of size 4x4.00 sq. mm + 2x4.00 sq. mm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor, single core cable drawn in and including PVC concealed conduit ISI marked, medium grade of adequate size with all conduit accessories medium grade ISI marked as required as specified and as directed. Note :- (i) Four run of PVC wire and two run of earth wire, 1 run of conduit shall be measured as one length.
60M&L for Submain wiring alongwith earth wire of size 4x6.00 sq. mm + 2x6.00 sq. mm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor, single core cable drawn in and including PVC concealed conduit ISI marked, medium grade of adequate size with all conduit accessories medium grade ISI marked as required as specified and as directed. Note :- (i) Four run of PVC wire and two run of earth wire, 1 run of conduit shall be measured as one length.
61M&L for Submain wiring alongwith earth wire of size 4x10.00 sq. mm + 2x10.0 sq. mm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor, single core cable drawn in and including PVC concealed conduit ISI marked, medium grade of adequate size with all conduit accessories medium grade ISI marked as required as specified and as directed. Note :- (i) Four run of PVC wire and two run of earth wire, 1 run of conduit shall be measured as one length.
62M&L for Submain wiring alongwith earth wire of size 4x16.00 sq. mm + 2x16.0 sq. mm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor, single core cable drawn in and including PVC concealed conduit ISI marked, medium grade of adequate size with all conduit accessories medium grade ISI marked as required as specified and as directed. Note :- (i) Four run of PVC wire and two run of earth wire, 1 run of conduit shall be measured as one length.
63S&F TPN DB 6 way, IP43 with acrylic door as per IEC 61439-3 sitable for flush/surface mounting with 100Amp fully insulated copper busbar for each phase with 2 shrouded neutral bar, 2 earth bar and cable ties, prefitted masking sheet, reversible Door with provision for FP MCB/RCBO as incommer and FP/TP/SP/SPN MCB's as outgoing without MCBs complete all as specified and directed.
64S&F TPN DB 8 way, IP43 with acrylic door as per IEC 61439-3 sitable for flush/surface mounting with 100Amp fully insulated copper busbar for each phase with 2 shrouded neutral bar, 2 earthbar and cable ties, prefitted masking sheet, reversible Door with provision for FP MCB/RCBO as incommer and FP/TP/SP/SPN MCB's as outgoing without MCBs complete all as specified and directed.
65S&F TPN DB 12 way, IP43 with acrylic door as per IEC 61439-3 sitable for flush/surface mounting with 100 Amp fully insulated Copper Busbar for each phase with 2 shrouded Neutral bar, 2 Earth bar and cable ties, prefitted masking sheet, reversible Door with provision for FP MCB/RCBO as incommer and FP/TP/SP/SPN MCB's as outgoing without MCBs complete all as specified and directed.
66S&F DB with sheet metal enclosure 240 volts, 12 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete all as specified and directed.
67S&F Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts 8 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed.
68S & F DB with sheet metal enclosure 240 volts, 6 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete all as specified and directed.
69Supply and fixing TPN, upto 32A, 415V 10 kA 'C' curve miniature circuit breaker (MCB) and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
70Supply and fixing TPN, upto 63A, 415V 10 kA 'C' curve miniature circuit breaker (MCB) and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
71Supply and fixing amp rating 240V, 10 kA 'C' curve miniature circuit breaker (MCB) of SPN upto 32 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
72Supply and fixing amp rating 240V, 10 kA 'C' curve miniature circuit breaker (MCB) of SPN upto 63 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
73Supply and fixing amp rating 240V, 10 kA 'C' curve miniature circuit breaker (MCB) SP upto 32 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
74Supply and fixing in replacement of existing damaged copper link connecting cable thimble/lug upto 100 Amp to MCCB terminal, fabricated from electrolytic grade copper strip upto 630 Amp rating, including drilling, bending, necessary hardware, cleaning of contact surfaces, tightening, testing and commissioning complete all as specified and directed by the Engineer-in-Charge.
75Description all as per ser item No. 74.00 but copper link connecting cable thimble/lug of 125 to 250 Amp complete all as specified and as directed.
76Description all as per ser item No. 74.00 but copper link connecting cable thimble/lug of 315 to 400 Amp complete all as specified and as directed.
77Description all as per ser item No. 74.00 but copper link connecting cable thimble/lug upto 630 Amp complete all as specified and as directed.
78Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and as directed by Engr-in-Charge.
79Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed by Engineer-in-Charge.
80Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-charge.
81M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm complete all as specified and as directed.
82M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat complete all as specified and as directed.
83Taking out old unserviceable LT under ground cable any type from trenches,pipes & poles complete all as specified and as directed.
84Supply and laying in replacement of XLPE LT 1100 Volt grade, armoured under ground cable of size 16 Sqmm 4core with stranded aluminium conductor in trenches /passing through pipes/ on poles etc complele all as specified and as directed.
85All as per srl item No 84 above but cable of size 25 Sqmm 3.5 core complete all as specified and as directed.
86All as per srl item No 84 above but cable of size 35 Sqmm 3.5 core complete all as specified and as directed.
87All as per srl item No 84 above but cable of size 50 Sqmm 3.5 core complete all as specified and as directed.
88All as per srl item No 84 above but cable of size 70 Sqmm 3.5 core complete all as specified and as directed.
89All as per srl item No 84 above but cable of size 95 Sqmm 3.5 core complete all as specified and as directed. Note for ser item No. 84 to 89:- Excavation, earthwork and protection of cable shall be measured and paid seperately.
90Supply and fixing MCCB 630 Amps 4 pole 50 kA 415 Volts 50 Hz with thermal adjustable magnetic settings including taking out old existing unserviceable MCCB from panels etc complete all as specified and as directed.
91All as per srl item No. 90 here in before but 400 Amps 50 kA all as speicifed and as directed.
92All as per srl item No. 90 here in before but 350 Amps 36 kA complete all as speicifed and as directed.
93All as per srl item No. 90 here in before but 250 Amps 36 kA complete all as speicifed and as directed.
94All as per srl item No. 90 here in before but 200 Amps 36 kA all as speicifed and as directed.
95All as per srl item No. 90 here in before but 160 Amps 36 kA all as speicifed and as directed.
96All as per srl item No. 90 here in before but 125 Amps 3 pole 25 kA all as speicifed and as directed.
97S & F in replacement of maintenance free battery 12 volt 180 AH complete as directed by Engr-in-Charge. Make:- Exide/Amron/Sucam
98S & F in replacement of maintenance free battery 12 volt 100/150 AH complete as directed by Engr-in-Charge. Make:- Exide/Amron/Sucam
99S&F in replacement of sealed maintenance free fully charged Nickle cadmium battery 65Ah, 12 volts complete all as specified and as directed by Engineer-in-Charge. Make: Sucam/ EXIDE/Amron
100S&F in replacement of sealed maintenance free fully charged Nickle cadmium battery 42Ah, 12 volts complete all as specified and as directed by Engineer-in-Charge. Make: Sucam/ EXIDE/Amron
101M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-31 (09 Mtr long) including two coats of bituminous paint internally and externally for the portion embedded in concrete and two coats of aluminium paint over one coat of red oxide primer to external/exposed surfaces complete all as specified and directed. Note:- Excavation/PCC shall be measured and paid separately under relevant items.
102M&L in replacement of lugs/thimbles at termination of LT cable by cutting the end portion and removing insulation and fixing new aluminium lugs /thimble properly with crimbing tool of size 185 -400 sq mm complete. complete all as specified and as directed.
103All as per srl item No. 102 here in before but for cable size 50-150 sq mm complete all as specified and as directed.
104All as per srl item No. 102 here in before but for cable size upto 35 sq mm complete all as specified and as directed.
105M&L for defect rectification LT cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal alluvial strata required for exposing the cable fault removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 400 Sq mm 3.5 core. The fault locating equipments will be brought to site within the hours of instruction from Engr-in-Charge and fault shall be rectified within 90 min overall.Note : Recovery at the rate of Rs. 2000/- per hour shall be levied for non rectification of faults.
106Supply & jointing heat shrinkable straight through joint kit suitable for LT 1100 Volt grade XLPE cable of size 400/500 Sqmm 3.5 core complete with treating of cable to make ready for jointing etc complete all as specified and as directed by Engr-in-Charge.
107All as per item No. 106 here in before but suitable for cable size 240-300 sq mm complete all as specified and as directed.
108All as per item No. 106 here in before but suitable for cable size 150-185 sq mm complete all as specified and as directed.
109All as per item No. 106 here in before but suitable for cable size 70-120 sq mm complete all as specified and as directed.
110Description all as per Srl item No.106 here in before but suitable for cable size 25-50 sq mm complete all as specified and as directed.
111Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57415686
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 33.94 Lakhs
LAST DATE 01-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of B/R Works Services In Certain Otm Bldgs At Rva Area, Provn Of Galvalume Sheet Shed In Omq And Provn Of Interlocking Tiles In Certain Omq At Af Stn Palam Under Ge Af Palam, Delhi Cantt-10
Basic Detail
Tender No 8026/A/T-65/E8
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 19 Sep 2026
Submission Date 01 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value 33.94 Lakhs
Tender Fee 500
EMD 67900
Exemption Available
Document List
72357686-ae8a-4623-867f-0685d2ba15d0.html
BOQ_883578.xls
tender65.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 01, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Oct 01, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Today
Oct 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today

Tender Documents

Download All (ZIP) ↓
html

72357686-ae8a-4623-867f-0685d2ba15d0.html

xls

BOQ_883578.xls

pdf

tender65.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders