Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #57415659

Tender For Repair /Maint Of Lt Feeder Pillar Boxes, Lt Ug Cables And Connected Works Of Lt Distribution System Including Attending Fuse Of Call At Map Naraina, 5 Sikh Li, Dgbr, Narainabaugh, Sanjevani Enclave, Me Line, Dental Offr Mess, 505 Jco Encla

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
49.50 Lakhs
Estimated cost
Bid Submission
29 Sep 2026
19 days left
EMD
99000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair /Maint Of Lt Feeder Pillar Boxes, Lt Ug Cables And Connected Works Of Lt Distribution System Including Attending Fuse Of Call At Map Naraina, 5 Sikh Li, Dgbr, Narainabaugh, Sanjevani Enclave, Me Line, Dental Offr Mess, 505 Jco Enclave, 505 Unit Line Area, Cod Area, 1811 Pnr Coy, 226 Supply Depot, Fol Depot, Kirby Map Accn, Kirby Offr Accn, Lao, Esd, Cicg, Subramaniyam Line & Bor Under Age E/M No-I Of Ge (U) Elect Supply Delhi Cantt-10

BOQ

Name of Work:- REPAIR /MAINT OF LT FEEDER PILLAR BOXES, LT UG CABLES AND CONNECTED WORKS OF LT DISTRIBUTION SYSTEM INCLUDING ATTENDING FUSE OF CALL AT MAP NARAINA, 5 SIKH LI, DGBR, NARAINABAUGH, SANJEVANI ENCLAVE, ME LINE, DENTAL OFFR MESS, 505 JCO ENCLAVE, 505 UNIT LINE AREA, COD AREA, 1811 PNR COY, 226 SUPPLY DEPOT, FOL DEPOT, KIRBY MAP ACCN, KIRBY OFFR ACCN, LAO, ESD, CICG, SUBRAMANIYAM LINE & BOR UNDER AGE E/M NO-I OF GE (U) ELECT SUPPLY DELHI CANTT-10
Sl. No. Item Description
1Material and labour for excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and leveling of bottom surface to required level complete all as specified and directed by Engineer- in- Charge.
2Material and labour for returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engineer- in- Charge.
3Material and labour for removing excavated material (i.e. soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
4Material and labour for Sand cushioning/sand covering for underground cable protection complete all as specified and directed by Engineer- in- Charge. Note: Note : Measurement shall be taken after punning down.
5Supply and laying for sub class 'B' bricks of old size (approved size locally available) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer- in- Charge.
6Material and labour for GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection complete all as specified and directed by Engineer- in- Charge.
7Material and labour for GI pipe light grade 80 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection complete all as specified and directed by Engineer- in- Charge.
8Material and labour for Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable complete all as specified and directed by Engineer- in- Charge.
9Material and labour for PCC 1:3:6 type C-2 (using 40 mm graded aggregate) for foundation, filling and mass concrete or similar works complete all as specified and directed by Engineer- in- Charge.
10Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade 3.5/4 core XLPE , armoured, electric power cables (heavy duty) with aluminium conductor of the following size including dismantling old one complete all as specified and directed by Engineer- in- Charge. Make : Havells/KEI/Polycab/Paragon
1110 Sqmm 4 Core
1216 Sqmm 4 Core
1325 Sqmm 4 core
1435 Sqmm 3.5 core
1550 Sqmm 3.5 core
1670 Sqmm 3.5 core
1795 Sqmm 3.5 core
18120 Sqmm 3.5 core
19150 Sqmm 3.5 core
20185 Sqmm 3.5 core
21240 Sqmm 3.5 core
22300 Sqmm 3.5 core
23Supply and fix in repairs ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Amps complete all as specified and directed by Engineer- in- Charge.
24Supply and fix in repairs MCCBs of following current carrying capacity complete all as specified and directed by Engineer- in- Charge.
253 Pole MCCB 630 Amps, Adjustable type,415V, 50KA rating
263 Pole MCCB 400 Amps, Adjustable type,415V, 36KA rating
273 Pole MCCB 315 Amps, Adjustable type,415V, 3KA rating
283 Pole MCCB 250 Amps, Thermal release type, 415 V, 25KA rating
293 Pole MCCB 200 Amps, Thermal release type, 415 V, 25KA rating
303 Pole MCCB 160 Amps, Thermal release type, 415 V, 16KA rating
313 Pole MCCB 125 Amps, Thermal release type, 415 V, 16KA rating
323 Pole MCCB 100 Amps, Thermal release type, 415 V, 16KA rating
334 Pole MCCB 630 Amps, 415 V, Adjustable type with breaking capacity 50 KA
344 Pole MCCB 400 Amps, 415 V, Adjustable type with breaking capacity 36 KA
354 Pole MCCB 315 Amps, 415 V, Adjustable type with breaking capacity 36 KA
364 Pole MCCB 250 Amps, 415 V, Thermal release type with breaking capacity 25 KA
374 Pole MCCB 200Amps, 415 V, Thermal release type with breaking capacity 25 KA
384 Pole MCCB 160 Amps, 415 V, Thermal release type with breaking capacity 16 KA
394 Pole MCCB 100 Amps , 415 V, Thermal release type with breaking capacity 16 KA
40Supply and fix in repairs Isolator 415 Volts of following current carrying capacity complete all as specified and directed by Engineer- in- Charge.
414 Pole 63 Amps
424 Pole 100 Amps
433 Pole 63 Amps
443 Pole 100 Amps
454 Pole 40 Amps
46Material and labour for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 25 to 50 sq.mm complete all as specified and directed by Engineer- in- Charge.
47All as per Item No.14 herein before but for cable of size 3.5 core 95 to 120 sq.mm complete all as specified and directed by Engineer- in- Charge.
48All as per Item No. 14 herein before but for cable of size 3.5 core 150 to 185 sq.mm complete all as specified and directed by Engineer- in- Charge.
49All as per Item No. 14 herein before but for cable of size 3.5 core 240 to 300 sq.mm complete all as specified and directed by Engineer- in- Charge.
50Disconnecting, dismantling of existing feeder panel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size, out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on suitable size foundation with 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including horizental busbar of aluminium strip of size 1.5 times of incoming MCCB for three phase 4 wire including the following accessories and fitted in complete all as specified and directed by Engineer- in- Charge. : -(a) Incoming: MCCB high breaking capacity 4 pole 415 volt 36 KA breaking cap adjustable thermal release range 630 amp -01 No(b) Outgoing: (i) MCCB 3 pole 415 volt 25 KA breaking cap thermal release range 160 amp – 06 No (iv) Multifunnction Meter, Phase Indicator (R, Y & B) with selector switch
51Disconnecting, dismantling of existing feeder panel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size, out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on suitable size foundation with 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including horizental busbar of aluminium strip of size 1.5 times of incoming MCCB for three phase 4 wire including the following accessories and fitted in complete all as specified and directed by Engineer- in- Charge. : -(a) Incoming: MCCB 4 pole 415 volt 25 KA breaking cap adjustable thermal release range 250 amp -01 No(b) Outgoing: (i) MCCB 3 pole 415 volt 16 KA breaking cap thermal release range 63 amp – 04 No (ii) MCCB 3 pole 415 volt 16 KA breaking cap thermal release range 40 amp – 02 No(iii) Multifunnction Meter, Phase Indicator (R, Y & B) with selector switch
52Supply, installing, testing and commissioning in replacement of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement of size not less than 400mm x 400mm x 300mm with 4 Nos 630 Amps aluminum bus bar and with 400 Amp MCCB, 4 pole, 36 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with suitable size of foundation complete all as specified and directed by the Engg-in-Charge. Please Enable Macros to View BoQ information
53Supply, installing, testing and commissioning in replacement of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement of size not less than 400mm x 400mm x 300mm with 4 Nos 630 Amps aluminum bus bar and with 400 Amp MCCB, 4 pole, 36 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with suitable size of foundation complete all as specified and directed by the Engg-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57415659
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49.50 Lakhs
LAST DATE 29-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair /Maint Of Lt Feeder Pillar Boxes, Lt Ug Cables And Connected Works Of Lt Distribution System Including Attending Fuse Of Call At Map Naraina, 5 Sikh Li, Dgbr, Narainabaugh, Sanjevani Enclave, Me Line, Dental Offr Mess, 505 Jco Enclave, 505 Unit Line Area, Cod Area, 1811 Pnr Coy, 226 Supply Depot, Fol Depot, Kirby Map Accn, Kirby Offr Accn, Lao, Esd, Cicg, Subramaniyam Line & Bor Under Age E/M No-I Of Ge (U) Elect Supply Delhi Cantt-10
Basic Detail
Tender No GE ELECT/TOKEN-41/2026-2027
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 08 Sep 2026
Submission Date 29 Sep 2026
Open Date 01 Oct 2026
Finance
Tender Value 49.50 Lakhs
Tender Fee 500
EMD 99000
Exemption Not Available
Document List
2f13e238-cedf-46bb-9a8e-73f13a86f288.html
BOQ_883714.xls
TD41.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

2f13e238-cedf-46bb-9a8e-73f13a86f288.html

xls

BOQ_883714.xls

pdf

TD41.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender