Tender For Repair/Replacement Of Ro Plants, Filteration Plant, Solar Water Heating System Including Geyser And Other Connected Works At Hq Cif (Delta) And Its repair renovation Units At Dharmund Under Age (I) Bhalra
Tender Value
9.99 Lakhs
Estimated cost
Bid Submission
22 Sep 2026
12 days left
EMD
19992
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nagrota → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of Ro Plants, Filteration Plant, Solar Water Heating System Including Geyser And Other Connected Works At Hq Cif (Delta) And Its repair renovation Units At Dharmund Under Age (I) Bhalra
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling and refixing the complete unit of unserviceable Solar Water Heater Plate with new Solar Water Heater Plate of following installed at various sites complete including repairing / replacing all defective parts such as Copper tubing, taughned glass, hot water tank, nuts, bolts, washers and all other minor accessories as required at site including painting the solar water heater water tank by rubbing the old paint and applying with two coats of synthetic enameled paint by spray painting where necessary and testing the same after repair all as specified and directed by Engr-in-charge. (a) 300 LPD |
| 2 | (b) 500 LPD |
| 3 | (c) 1000/2000 LPD |
| 4 | Supply and fix the following items / spares in replacement for Solar Heaters of various capacities as mentioned in Serial No 1 here-in-before all as specified and directed by Engr-in-charge.(a) Heating element of capacity upto 2 KW (Electric rod) having rubber washer of size 1 ¼” or 1 ½” complete all as specified. |
| 5 | (b) Glycol (Anti freezing solution) for filling in copper tubes complete all as specified. |
| 6 | (c) Coupling gasket |
| 7 | (d) Hot rubber pipe of 20mm dia complete all as specified and directed |
| 8 | (e) Float valve assembly 25mm dia complete all as specified. |
| 9 | (f) Thermostat suitable for solar heater complete all as specified |
| 10 | (g) Dead flange with nut bolts and washers complete all as specified. |
| 11 | (h) Temp gauge 0 to 120 degree centrigade all as specified. |
| 12 | Taking up or down old unserviceable GI pipe medium grade galvanised with all fitting laid in trenches/on wall /floor /ceiling with clamps complete all as specified of size 15 mm dia and directed by Engr-in-charge. |
| 13 | Taking up or down old unserviceable GI pipe medium grade galvanised with all fitting laid in trenches/on wall /floor /ceiling with clamps complete all as specified of size 20 mm dia and directed by Engr-in-charge. |
| 14 | Taking up or down old unserviceable GI pipe medium grade galvanised with all fitting laid in trenches/on wall /floor /ceiling with clamps complete all as specified of size 40/50 mm dia and directed by Engr-in-charge. |
| 15 | M&L for GI pipe medium grade galvanised 15 mm dia with all fitting laid in trenches/on wall /floor /ceiling with clamps complete all as specified and directed by Engr-in-charge |
| 16 | M&L for GI pipe medium grade galvanised 20 mm dia with all fitting laid in trenches/on wall /floor /ceiling with clamps complete all as specified and directed by Engr-in-charge |
| 17 | M&L for GI pipe medium grade galvanised 40 mm dia with all fitting laid in trenches/on wall /floor /ceiling with clamps complete all as specified and directed by Engr-in-charge |
| 18 | M&L for GI pipe medium grade galvanised 50 mm dia with all fitting laid in trenches/on wall /floor /ceiling with clamps complete all as specified and directed by Engr-in-charge |
| 19 | S & F in repair sheet metal enclosure for DBs single door when MCBs to be used Single pole and neutral with 200 Amps rated bus bar 240 V 4 Way complete all as specified and as directed by Engr-in-charge. |
| 20 | S & F in repair for MCB SPN 'C' series, 32 Amp , 230 Volts complete all as specified and as directed by Engr-in-charge. |
| 21 | S & F in repair for MCB 'C' series, single pole 6-32A, 240 V complete all as specified and as directed by Engr-in-charge. |
| 22 | On-site Repair / Maintenance and Servicing of RO /filtration plants by dismantling, checking all parts i.e. Pre-filter, granular activated carbon block filter, membrane, UV disinfection / filtration system, adaptor, pressure pump set, main pump motor, solenoid valve, flow controller, all gauges, filling of anti-scalent liquid, checking functioning of all type meters, electric wiring, contactors & relay, switches, valves and replacement of old unserviceable parts, checking of leakages of any part of plants and pipe line by new parts and pipe line including re-assembling the same as original and reinstalling at same place including re-connecting with the existing water supply system and testing at full capacity discharge of filtered water complete all as specified and as directed by Engr-in-charge of the following description :-(a) RO plant 50 Lts/Hours capacity. |
| 23 | (b) RO Plant of 150 Ltrs/Hours capacity |
| 24 | (c) RO Plant of 250 Ltrs/Hours capacity |
| 25 | (d) Filtration Plant of 2500 Ltrs/Hours capacityNotes for Serial Item No 01 :- 1. Spare parts required for replacement of the defective parts to make the RO Plant fully functional shall be measured and paid separately under appropriate item of this Schedule as 'Supply only'. |
| 26 | Repair / Maintenance of Feeding Pump of 0.37 KW / 0.5 HP installed in RO plant at various locations by disconnecting of RO plant carefully for repair, rewinding with super enamelled copper winding wire of suitable size, greasing, change of capacitor, bearing etc and reassembling of pump at its original position, complete all as specified and directed by Engr-in-charge. |
| 27 | Repair / Maintenance of Pressure Pump of 1 to 2 HP installed for RO/water filtration plant at various location by disconnecting of filtration plant carefully for repair, rewinding with super enamelled copper winding wire of suitable size, greasing, change of capacitor, bearing etc and reassembling of pump at its original position, complete all as specified and directed by Engr-in-charge. |
| 28 | Supply only Feeding Pump suitable for RO filtration plant of rating 0.37/0.5 KW/HP, 230 volts, 50 Hz, Single phase, 20 mtr head and discharge rate 40 LPM, complete all as specified and directed by Engr-in-charge.Make : Crompton Greaves / Kirloskar / Siemens |
| 29 | Supply only Pressure Pump suitable for small water filtration plant of rating 0.75/1.0 KW/HP, 230 volts, 50 Hz, 3 stage & discharge rate 750 LPH, complete all as specified and directed by Engr-in-charge.Make : Crompton Greaves / Kirloskar / Siemens |
| 30 | Supply only Pressure Pump suitable for small water filtration plant of rating 1/1.50 KW/HP, 230 volts, 50 Hz, 5 stage and discharge rate 750 LPH, maximum head 47 meter, complete all as specified and directed by Engr-in-charge.. Make : Crompton Greaves / Kirloskar / Siemens |
| 31 | Maintenance and Repair of Control Unit with replacement of defective parts of RO plant of capacity 50/150/250 LPH complete all as specified and as directed by Engr-in-charge. |
| 32 | Supply only Pre-Filter (Micronic Filter) candle of following size, complete all as specified and directed by Engr-in-charge.. Make : Renuka / Kent / Eureka Forbes(a) Size 10 inch |
| 33 | (a) Size 20 inch |
| 34 | Supply only Carbon block Filter of following size, complete all as specified and directed by Engr-in-charge.. Make : Renuka / Kent / Eureka Forbes(a) Size 10 inch |
| 35 | (a) Size 20 inch |
| 36 | Supply only Membranes of following capacity, complete all as specified and directed by Engr-in-charge.Make : Renuka / Kent / Eureka Forbes(a) 150 LPH |
| 37 | (b) 250 LPH |
| 38 | (c) 50 LPH |
| 39 | Supply and fix complete ultra violet system (UV) for 50/75/100/150/ 250/500 LPH RO plant, complete all as specified and directed by Engr-in-charge.Make : Renuka / Kent / Eureka Forbes |
| 40 | Supply only Media Cylinder of following capacity, complete all as specified and directed by Engr-in-charge.Make : Renuka / Kent / Eureka Forbes(a) 150 LPH |
| 41 | (b) 250 LPH |
| 42 | Supply only flow restrictor adjuster of following capacity, complete all as specified and directed by Engr-in-charge.Make : Renuka / Kent / Eureka Forbes(a) 150 LPH |
| 43 | (b) 250 LPH |
| 44 | Supply only Chemical Dozing System (AD system for antiscalent liquid) for RO plant, complete all as specified and directed by Engr-in-charge.Make : Renuka / Kent / Eureka Forbes |
| 45 | Supply only Micronic Shell (Filter housing) of following size, complete all as specified and directed by Engr-in-charge.Make : Renuka / Kent / Eureka Forbes(a) 20 inches |
| 46 | Supply only Anti-scalant Liquid (membrane protector), complete all as specified and directed by Engr-in-charge.Make : Renuka / Kent / Eureka Forbes |
| 47 | Supply only Bib Tap, cast copper alloy, 15mm bore, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specified and directed by Engr-in-charge. |
| 48 | Supply only Stop Valve, cast copper alloy, 15mm bore, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specified and directed by Engr-in-charge. |
| 49 | Supply only CPVC pipe of outer dia 16mm size, complete all as specified and directed by Engr-in-charge.Make : Renuka / Kent / Eureka Forbes |
| 50 | Supply only CPVC pipe of outer dia 20mm size, complete all as specified and directed by Engr-in-charge.Make : Renuka / Kent / Eureka Forbes |
| 51 | Supply only Brass elbow for CPVC pipe of 16mm size, complete all as specified and directed by Engr-in-charge. Make : Renuka / Kent / Eureka Forbes |
| 52 | Supply only Brass elbow for CPVC pipe of 20mm size, complete all as specified and directed by Engr-in-charge. Make : Renuka / Kent / Eureka Forbes |
| 53 | Supply only CPVC union of 16mm size, complete all as specified and directed by Engr-in-charge.Make : Renuka / Kent / Eureka Forbes |
| 54 | Supply only CPVC union of 20mm size, complete all as specified and directed by Engr-in-charge.Make : Renuka / Kent / Eureka Forbes |
| 55 | Supply only capacitor of 10 MFD, complete all as specified and directed by Engr-in-charge.Make : L&T / ABB / Siemens / GE |
| 56 | Supply only Solenoid Valve, complete all as specified and directed by Engr-in-charge.Make : Renuka / Kent / Eureka Forbes |
| 57 | Supply only CPVC pipe Adhesive, complete all as specified and directed by Engr-in-charge. |
| 58 | Supply only Taflon Tape for RO, complete all as specified and directed by Engr-in-charge. |
| 59 | Maintenance and Repair of Control Unit of Filteration Plant of capacity 2500 LPH complete all as specified and as directed by Engr-in-charge. |
| 60 | Supply only DOL starter suitable for 1 to 2 HP capacity electric motor, complete including taking down old unserviceable starter all as specified and as directed by Engr-in-charge. |
| 61 | Supply Laying, jointing in repair with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 95 Sqmm 3.5 core , 1100 volts, grade complete all as specified and as directed. |
| 62 | Supply Laying, jointing in repair with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 50 Sqmm 3.5 core , 1100 volts, grade complete all as specified and as directed. |
| 63 | Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 16 Sqmm nominal cross section x 4 core. |
| 64 | Cutting existing road surfaces or hard standing 0.45 mtr depth and 0.3 mtr width (22 CM thick comprising bituminous topping) for laying of pipes/cables and making good to the disturbed surfaces to match with existing complete all as specified and directed. Note : Rate quoted by the contractor deemed to be inclusive of PCC 1:2:4 to be required to making good the disturbed surface to match with existing. |
| 65 | Excavation in trenches in hard/dense soil not exc. 1.5 metre wide and n'exc. 1.50m deep for pipes and getting out complete all as specified and directed. |
| 66 | Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft/ loose soil, complete all as specified and directed. |
| 67 | Removing excavated material in soft/ loose soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and directed. |
| 68 | M&L for sand cushning to U/G cable in layers of 23cm thick( 8 Cm before laying the cable and 15Cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed. |
| 69 | M & L for Old size sub class ‘B’ bricks, laid in trenches as cable covers complete all as specified and directed. |
| 70 | Taking down carefully Geyser of capacity 25 ltrs from its position for repair/servicing such as removalof dust, checking, replacing worn out parts, rubber etc, re-assembling at its position after repair,testing & commissioning & connecting to electric system with suitable size cable, complete all asspecified & directed by Engr-in-charge.Note : Rates quoted by contractor shall deemed to be inclusive all minor items and no extra paymentshall be admissible except for the items which are to be replaced which shall be measured and paidseparately under respective item of Schedule 'A'. |
| 71 | Supply & fixing in repalecement of geyser steel tank of capacity 25 ltrs, complete all as specified & directed by Engr-in-charge. |
| 72 | Supply & fixing in repalecement of heating element for geyser, 1500 watt, round type, complete all as specified & directed by Engr-in-charge. |
| 73 | Supply & fixing in repalecement of heating element for geyser, 1500 watt, triangle type, complete all as specified & directed by Engr-in-charge. |
| 74 | Supply & fixing in repalecement of thermostat suitable for geyser of any capacity, complete all as specified & directed by Engr-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender