Tender For Repair / Maintenance Of External Water Supply System And Allied Works At Rv And Technical Area At Af Stn Palam Under Ge Af Palam, Delhi Cantt-10
Tender Overview
Project Description
Tender for Repair / Maintenance Of External Water Supply System And Allied Works At Rv And Technical Area At Af Stn Palam Under Ge Af Palam, Delhi Cantt-10
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-Sep-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 06-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth in loose/soft soil, getting out and leveling the bottom surface to required gradient for laying of water supply mains complete all as specified and directed by Engineer-in-Charge. |
| 2 | Returning, filling in, including levelling watering and well ramming in layers not exc 25cm thick complete all as specified and directed by Engineer-in-Charge. |
| 3 | Removal of surplus excavated soil to a distance not exc 50mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 4 | Taking up or down steel tubing and connections of size 15 mm bore dia including fittings complete all as specified and directed by Engineer-in-Charge. |
| 5 | All as per srl item No 4 here-in-before but of size 20mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 6 | All as per srl item No 4 here-in-before but of size 25mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 7 | All as per srl item No 4 here-in-before but of size 40mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 8 | All as per srl item No 4 here-in-before but of size 50mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 9 | All as per srl item No 4 here-in-before but of size 80mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 10 | All as per srl item No 4 here-in-before but of size 150mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 11 | Supply, laying & testing steel water tubing, medium grade, galvanised of size 15 mm bore dia, ISI marked with and including ISI marked GI fittings such as tees, bends, elbow, reducer, unions, clamps etc fixed on wall / laid in trench /roof (with proper clamping arrangements) complete all as specified and as directed by Engineer-in-Charge. |
| 12 | All as per srl item No 11 here-in-before but size 20mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 13 | All as per srl item No 11 here-in-before but size 25mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 14 | All as per srl item No 11 here-in-before but size 40mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 15 | All as per srl item No 11 here-in-before but size 50mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 16 | All as per srl item No 11 here-in-before but size 80mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 17 | All as per srl item No 11 here-in-before but size 150mm bore dia and heavy grade complete all as specified and directed by Engineer-in-Charge. |
| 18 | Taking up or down cast iron/ ductile iron water mains, with spigot and socket ends including burning out lead joints and recovering lead of size 80mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 19 | All as per item No 18 here-in-before but of size 100mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 20 | All as per item No 18 here-in-before but of size 150mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 21 | Supplying, laying, jointing, testing cast iron pipe with spigot and socketed ends centrifugally cast, class LA, including rubber gasket/ tyton/ lead joints conforming to IS-1536-1976 laid in trenches of the 80mm bore pipe complete all as specified and directed by Engineer-in-Charge. |
| 22 | All as per srl item No 21 here-in-before but of size 100mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 23 | All as per srl item No 21 here-in-before but of size 150mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 24 | M&L for 80 mm ductile iron pipe with spigot and socketed ends, centrifugally cast, class k-9 (IS-8329-2000) with tyton joints in any length laid in trenches or fixed on pillars etc complete all as specified and directed by Engineer-in-Charge. |
| 25 | M&L for 100 mm ductile iron pipe with spigot and socketed ends, centrifugally cast, class k-9 (IS-8329-2000) with tyton joints in any length laid in trenches or fixed on pillars etc complete all as specified and directed by Engineer-in-Charge. |
| 26 | M&L for 150 mm ductile iron pipe with spigot and socket ends, centrifugally cast, class k-9 (IS-8329-2000) with tyton joints in any length laid in trenches or fixed on pillars etc complete all as specified and directed by Engineer-in-Charge. |
| 27 | Material & labour for CI special fittings of any size, any type ISI marked as required at site such as bends (any type, radius and angle), Taper any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch, \\"Y\\" junction, double branch, cross (all socket or socket and spigot), collar, caps and plugs upto 150mm bore etc. complete all as specified and directed by Engineer-in-Charge. |
| 28 | M&L for DI specials such as tees, bends, collars of any sizes and radius, tapers, tail pieces caps and plug upto 200 mm bore dia complete all as specified and as directed by Engr-in-Charge. |
| 29 | Supply and fixing in replacement of unserviceable GI fittings such as reducers, tee, elbow, socket, nipple, plug, reducer elbow, reducer socket, union and other connected accessories of size 15 mm to 80 mm bore dia complete all as specified and as directed by Engineer-in-charge. |
| 30 | M&L for replacement for run lead joints for CI/DI pipe 80mm bore dia spigot & soketed/CI fittings including all jointing material required at site complete all as specified and directed by Engineer-in-Charge. |
| 31 | All as per srl item No 30 here-in-before but of size 100mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 32 | All as per srl item No 30 here-in-before but of size 150mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 33 | All as per srl item No 30 here-in-before but of size 300mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 34 | S&F in replacement gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for iron pipe or for union and fixed complete for size 50mm bore dia complete including taking up or down old unserviceable gate valve of 50mm bore dia complete all as specified and as directed by Engineer-in-Charge. |
| 35 | All as per item No 34 here-in-before but of size 40mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 36 | All as per item No 34 here-in-before but of size 25mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 37 | All as per item No 34 here-in-before but of size 20mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 38 | All as per item No 34 here-in-before but of size 15 mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 39 | S&F in replacement including jointing and testing of cast iron sluice valve, 80mm bore class PN-1.6, ISI marked, flanged ends drilled having stainless steel /brass spindle with cast iron wheel at top complete with nuts, bolts,washers and gaskets including taking out old unserviceable sluice valve for the 80mm bore size complete all as specified and directed by Engr-in-charge. |
| 40 | All as per srl item No 39 here-in-before but of size 100mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 41 | All as per srl item No 39 here-in-before but of size 150mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 42 | All as per srl item No 39 here-in-before but of size 200mm bore dia complete all as specified and directed by Engineer-in-Charge. |
| 43 | Material and labour for construction of valve pit chamber having internal dimension 120 cm x 120 cm x 120 cm (internal height) using 15cm thick PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) for foundation, 15mm thick rendering with CM (1:4), all around, brick work in CM (1:6) and PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 8mm thick MS sheet cover with locking arrangement with and including 50 mm pad lock with double key arrangement, MS frame made out of 40mm x 40mm x 6 mm thick angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of metal primer including necessary excavation in any type of soil, returning/ filling in and removal of surplus soil to a distance not exc 50 mtr away and depositing where directed at level not exc 1.5 m above the starting point including demolition / dismantling of existing valve chamber complete all as specified and directed by Engineer-in-Charge. |
| 44 | Material and labour for construction of valve pit chamber having internal dimension 90 cm x 90 cm x 90 cm (internal height) using 15cm thick PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) for foundation, 15mm thick rendering with CM (1:4), all around, brick work in CM (1:6) and PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 8mm thick MS sheet cover with locking arrangement with and including 50 mm pad lock with double key arrangement, MS frame made out of 40mm x 40mm x 6 mm thick angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of metal primer including necessary excavation in any type of soil, returning/ filling in and removal of surplus soil to a distance not exc 50 mtr away and depositing where directed at level not exc 1.5 m above the starting point including demolition / dismantling of existing valve chamber complete all as specified and directed by Engineer-in-Charge. |
| 45 | M&L for augering of holes in true horizontal position under road (by trench less method) by means of mechanical rig covering in route up to 1.5 mtr deep and not exceeding 30mtr long for passing the water pipe lines of up to 150mm bore complete all as specified and directed by Engineer-in-Charge. |
| 46 | M&L for well cap in replacement with housing clamp for upto 300 mm dia bore pipe in two pieces having 80 mm dia hole in centre with external bracket of flat iron of size 100mm x 6mm thick complete with nuts, bolts and washers etc including welding and painting etc including taking down old unserviceable well cap and depositing to MES store yard complete all as specified and directed by Engineer-in-Charge. |
| 47 | Material & Labour for cleaning internal portion of stone masonry/RCC underground/ Semi Underground water storage sump of capacity upto 01 lakh gallons including following process:-(a) Mechanised removal of all remaining dirty water by high capacity submersible pump set(b) Removal of sludge by Vacuum operated German pump(c) Cleaning of walls, ceiling and bottom of tank by German made high pressure rotary jet 120 bar pressure(d) Removal of all dirty particles by industrial wet vacuum cleaner leaving the tank 99.9 % physically cleaned(e) Sterlization of tank by Eco-friendly bio-degradable and highly effective against all pathogens(f) Sterlization of tank atmosphere by industrial UV radiator leaving the tank completely sterlized by specilized method complete all as specified and as directed by Engr-in-Charge.Note:- The item rate includes the cost of weather proof painting of details on tank such as (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank. |
| 48 | All as per srl item No 47 above here-in-before but for Over Head Tank upto 45 mtr staging (Height of OH Tank) of capacity 01 Lakh Gallons complete all as specified and as directed by Engr-in-charge.Note :- Rates for providing the scaffolding and necessary pumping equipment shall be deemed to be included in the unit item rate. |
| 49 | All as per srl item No 47 above here-in-before but for Over Head Tank upto 45 mtr staging (Height of OH Tank) of capacity upto 50,000 Gallons complete all as specified and as directed by Engr-in-charge.Note :- Rates for providing the scaffolding and necessary pumping equipment shall be deemed to be included the unit item rate. |
| 50 | All as per srl item No 47 above here-in-before but for Static water tank of capacity upto 20,000 Gallons complete all as specified and as directed by Engr-in-charge. Note:- The cleaning of static water tank shall be carried out quarterly. |
| 51 | Material and labour in replacement of insulated rubber chequered sheet of size 2.00 mtr x 1.00 mtr not less than 19mm thick complete all as specified and directed by Engr-in-charge. |
| 52 | Supply and fixing in replacement of CI NRV of 80mm bore both end flanged with necessary packing materials nut, bolt & washer of suitable size PN 1.6 complete all as specified and directed by Engr-in-charge. Make:- Kartar/Kirloskar or equivalent as per list of makes. |
| 53 | Supply and fixing in replacement of CI NRV of 100mm bore both end flanged with necessary packing materials nut, bolt & washer of suitable size PN 1.6 complete all as specified and directed by Engr-in-charge Make:- Kartar/Kirloskar or equivalent as per list of makes. |
| 54 | Supply and fixing in replacement of CI NRV of 150 mm bore both end flanged with necessary packing materials nut, bolt & washer of suitable size PN 1.6 complete all as specified and directed by Engr-in-charge Make:- Kartar/Kirloskar or equivalent as per list of makes. |
| 55 | Supply & fixing in replacement of valve pit cover/ Sump manhole cover/ pressure pump shade etc made out of MS frame 40mm x 40mm x 6mm thick angle iron with and including 6/8 mm thick MS top cover with locking arrangement and painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge. |
| 56 | Supply only CDD 5000 (two components chlorine dioxide powder) (CAS No 10049-04-4 conforming to ISO9001-2015) white in colour highly soluble in water, 99.9% effective against water borne micro organisms disinfectant for chlorination of water complete all as specified and directed by Engr-in-Charge. Note:- Receipt Voucher of material shall be produced during the submission of RAR. |
| 57 | Disconnecting existing defective electric motor of any make upto 30 to 50 HP from electric mains by isolating the naked connections, removing from foundation by unscrewing the nuts, bolts etc, dis-couple from pump etc opening of motor for inspection in presence of Engr-in-Charge & carry out minor repairs at site re-assembling the motor and pump after repair, refixing in position re-connecting same as prior to removing from foundation including replacement of nuts, bolts, washers if necessiates of suitable size, testing and commissioning complete all as specified and directed. Note :- (a) Replacement of all parts of motor (minor and major) shall be deemed to be included in this item rate. (b) In case of repairs not possible at site, the motor and pump shall be shifted to workshop of authorised service centre and cost of shifting to wksp and back to site included in the item rates. (c) The cost of replacement of motor winding shall be measured and paid separately under respective item. |
| 58 | All as per item No. 57 above but capacity 15 to 25HP of any type & size complete all as specified and directed by Engr-in-Charge. |
| 59 | All as per item No. 57 above but capacity upto 10HP of any type & size complete all as specified and directed by Engr-in-Charge. |
| 60 | All as per item No. 57 above but for monoblock of capacity upto 5HP of any type & size complete all as specified and directed by Engr-in-Charge. |
| 61 | Taking out old unserviceable/burnt copper winding of motors capacity up to 30 to 50 HP and material and labour for rewinding of electric motor of capacity up to 30 to 50 HP, 3 Phase with super enameled copper winding wire of suitable gauge as per existing including cleaning of rotor slots, all winding/ insulation material, varnishing etc. complete and testing at site on full load after reinstallation to the full satisfaction of Engr-in-Charge complete all as specified and as directed by Engr-in-Charge. Note:- Defective motor shall be obtained from ser item No. 57 here in above. |
| 62 | All as per item No 61 here in before but capacity 15 to 25 HP , three phase, of any type & size complete all as specified and directed by Engr-in-Charge. Note:- Defective motor shall be obtained from ser item No. 58 here in above. |
| 63 | All as per item No 61 here in before but cap upto 10 HP, three phase, of any type & size complete all as specified and directed by Engr-in-Charge. Note:- Defective motor shall be obtained from ser item No. 59 here in above. |
| 64 | All as per item No.61 above but for monoblock of capacity upto 5HP of any type & size complete all as specified and directed by Engr-in-Charge. Note:- Defective motor shall be obtained from ser item No. 59 here in above. |
| 65 | M&L for dismantling and taking out defective parts of centrifugal pump set coupled with motor of capacity 30 to 50 HP any type any stage and taken to authorised workshop and refixing the same to its original position after repair and making it serviceable completely by repairing/ replacement of unserviceable parts (major and minor) complete all as specified and as directed by Engineer-in-Charge.Note: (i) Cost of transport to civil workshop and back to site shall be included in the item rate.(ii) Cost for repair/ replacement of spare parts (minor and major) shall be included in the item rate. |
| 66 | All as per item No 65 here in before but capacity of motor 15 to 25 HP, three phase, of any type & size complete all as specified and as directed by Engineer-in-Charge. |
| 67 | All as per item No 65 here in before but cap upto 10 HP, three phase, of any type & size complete all as specified and as directed by Engineer-in-Charge. |
| 68 | All as per item No. 65 above but for monoblock of capacity upto 5HP of any type & size complete all as specified and as directed by Engineer-in-Charge. |
| 69 | Disconnecting electric connections from starter, disconnecting the water connections carefully by unscrewing the nuts, bolts and taking out the submersible pump set upto 10 HP (including motor) from the borewell including column pipes, and submersible cable, disconnecting the pump and motor opening the pump and motor to locate the faults in presence of Engineer-in-Charge, and carry out necessary repairs as directed including transporting to authorised workshop, re-assembling the same after repair, taking down to the well, including column pipe of any dia, 10 ft long, and submersible cable, which have been taken out, re-connecting all electrical and water connections as per existing complete testing and commissioning including new packing materials, nuts, bolts, washers of suitable size complete all as specified and as directed. Note :- (a) Replacement of all unserviceable parts of pump and motor shall be deemed to be included this item rate. (b) In case of repairs not possible at site, the motor and pump shall be shifted to authorised workshop and cost of shifting to workshop and back to site included in the item rates. (c) replacement of motor winding shall be measured and paid separately under respective item. |
| 70 | Taking out old unserviceable/burnt winding from the submersible 3 phase motors up to 10 HP capacity and M& L for rewindinig with insulated winding wire as per existing gauge complete including transportation to and fro and as approved by Engr-in Charge and testing after repair complete all as specified and as directed. |
| 71 | Supply and fixing in replacement column pipe 50mm dia bore made of meduim grade GI pipe, 10 feet length both ends flanged & drilled including cutting of grooves for submersible cable and fabrication etc. complete all as specified and as directed by Engineer-in-Charge. |
| 72 | Supply and fixing in replacement column pipe 80mm dia bore made of meduim grade GI pipe, 10 feet length both ends flanged & drilled including cutting of grooves for submersible cable and fabrication etc. complete all as specified and as directed by Engineer-in-Charge. |
| 73 | Supply and fixing Digital Auto timer clock suitable for borewells complete all as specified and directed by Engr-in-charge. |
| 74 | Supply and fixing of single phase preventor VSP-2 / VSP-1 complete all as specified and directed by Engr-in-Charge. Make : Minilac/ L &T/ Lagrand |
| 75 | Disconnecting electrically on load change over switch of any type as per site requirement and supply & fixing and connecting change over switch 4 pole 200 Amp 440 volts conforming to relevant IS including all connecting and jointing material complere all as specified and directed. Make:- Havells/Standard. |
| 76 | Disconnecting electrically,isolating the existing unserviceable MCCB of any make and capacity and Supply, fixing, connecting, testing and commissioning MCCB, 440 volts fixed in existinig panel including necessary modification for new MCCB, 400 amp capacity 4 pole breaking capacity 36 KA conferminig to relevant IS including all joining and connecting material all as specified. Make:- Schnider//L&T/Havells. |
| 77 | All as per item No. 76 here in before but 250 Amps breaking capacity 36 KA, 4 pole complete all as specified and as directed by Engineer-in-Charge. |
| 78 | All as per item No. 76 here in before but 200 Amps breaking capacity 36 KA, 4 pole complete all as specified and as directed by Engineer-in-Charge. |
| 79 | All as per item No. 76 here in before but 125 Amps breaking capacity 25 KA, 3 pole complete all as specified and as directed by Engineer-in-Charge. |
| 80 | All as per item No. 76 here in before but 125 Amps breaking capacity 16 KA, 4 pole complete all as specified and as directed by Engineer-in-Charge. |
| 81 | All as per item No. 76 here in before but 100 Amps breaking capacity 25 KA, 3 pole complete all as specified and as directed by Engineer-in-Charge. |
| 82 | All as per item No. 76 here in before but 25 to 100 Amps breaking capacity 16 KA, 3 pole complete all as specified and as directed by Engineer-in-Charge. |
| 83 | Supply, connecting, testing and commissioning submersible cable with copper conductor, stranded of size 4 sqmm 3 core complete including taking out old unserviceable cable complete all as specified and as directed. |
| 84 | All as per item No 83 here in before but 6 sqmm, 3 core complete all as specified and as directed by Engineer-in-Charge. |
| 85 | Supply and fixing PVC copper conductor wire unsheathed FRLSH of size 4.00 sqmm single core multistranded complete all as specified and as directed by Engineer-in-Charge. |
| 86 | Supply and fixing PVC copper conductor wire unsheathed FRLSH of size 1.50 sqmm single core multistranded complete all as specified and as directed by Engineer-in-Charge. |
| 87 | Disconnecting and lifting out of existing submersible pump set from borewell capacity upto 7.5 HP alongwith their column pipe and submersible cable from bore well from any depth and lowering after repair complete all as specified and directed by Engineer-in-charge. |
| 88 | Material & Labour for painting to existing centrifugal motor & pumping set complete including base frame with super enameled paint of existing colour coat by spray painting and writing of SM/MES No with white paint, 30 to 50 HP capacity complete all as specified and as directed by Engineer-in-Charge. |
| 89 | All as per item No 88 above but 15 to 25 HP capacity complete all as specified and directed. |
| 90 | All as per item No 88 above but upto 10 HP capacity complete all as specified and directed. |
| 91 | All as per item No 88 above but for monoblock of cap upto 5 HP complete all as specified and directed. |
| 92 | M&L for repairs, servicing of liquid chlorine dosing system, any make, any type/capacity complete including replacement of chlorine dosing pipe upto 2.5 mtr length for each plant including servicing of motor, washing of chlorine tank with descaling agent and re-commissioning testing of plant complete all as specified and directed. |
| 93 | Supply & fixing in replacement lead acid battery 12 volts 180 AH of existing type & size suitable for Gen sets 15 to 125 KVA including initial charging and copper connector complete all as specified and directed by Engineer-in-charge. Make: Exide/ Amron |
| 94 | Material & Labour for painting to existing LT panels, indoor type installed at various pump houses with super enameled paint of approved colour on exposed surface including preparation of surfaces and applying primer coat complete all as specified and directed by Engineer-in-charge. |
| 95 | All as per item No 94 above but borewell panels (out door type) complete all as specified and directed by Engineer-in-charge. |
| 96 | Supply and fixing in replacement BI metallic over load relay, range 45-75 amp rating for automatic starters complete all as specified and directed by Engineer-in-charge. Make: Legrand/LT |
| 97 | All as per item No 96 above but 24-42 Amps complete all as specified and directed by Engineer-in-charge. |
| 98 | All as per item No 96 above but 9-23 Amps complete all as specified and directed by Engineer-in-charge. |
| 99 | Supply and fixing for Amps meters 0 to 200 Amps, Digital type with selector switches, CTs etc complete all as specified and directed by Engineer-in-charge. |
| 100 | Supply and fixing for volt meters 0 to 500 Volt, Digital type 415 volts with selector switches, CTs etc complete all as specified and directed by Engineer-in-charge. |
| 101 | S&F in replacement of Pressure switch suitable for pressure pump of capacity upto 1.0 HP and testing complete all as specified and as directed by Engineer-in-charge. Make:- crompton/Denfosis/Orin |
| 102 | M&L for disconnecting electric supply and dismantling from foundation electric driven pressure pumpset of capacity 0.5 to 1.5 HP and taking to authorised workshop for rewinding / over hauling of mono block pump set and taking back and refixing the same after rewinding to its original position making electric connection and testing. Note:- Cost of rewinding / overhauling, replacement of all unserviceable parts such as impeller, cooling fan, Air Tank etc are deemed to be included in the item rates. |
| 103 | Supply and fixing air tank suitable for 0.5 to 1.5 HP presuure pump set complete all as specified and as directed by Engineer-in-charge. |
| 104 | Supply and fixing pressure gauge 0-10 Kg/ SqCm suitable for pressure pump complete all as specified and as directed by Engineer-in-charge. Make:- Danfos |
| 105 | Supply and fixing Automatic pressure kit suitable for 0.5 to 1.0 HP pressure pump set complete all as specified and as directed by Engineer-in-charge. |
| 106 | M&L for painting of water supply header of size 100/150/200/250/300mm dia with two coats of synthetic enamel paint with a suiatble colour complete all as specified and as directed by Engineer-in-charge. |
| 107 | M&L for chemical and bacteriological analysis and potability of water obtained from Delhi Jal Board & borewells from Sriram Test House/ MCD approved/ NABL approved micro engineering and testing lab and submitting the report in duplicate complete all as specified and as directed by Engineer-in-charge. Note:- The testing of water shall be carried out quarterly. |
| 108 | S&F in replacement wire netting of stainless steel wire 1.4 mm dia size of mesh 12mm fixed to bend pipe dia100mm to 200mm fixed with GI clamp including nuts and bolts etc complete all as specified and as directed by Engr-in-Charge. |
| 109 | M&L for cutting of road for laying of UG CI/DI/GI pipe after laying pipe making good damaged surfaces of road to match the adjoing existing surfaces using paste premix bituminous 50mm thick polymer based material over WBM 75mm thick including rolling work etc complete all as specified and as directed by Engineer-in-charge. |
| 110 | Supply and fixing in replacement of unserviceable display board for showing details of pump houses with location as provided by Engineer -in-charge made out of PVC sheet Box of size 1.5mtr x 1mtr x 0.20 mtr including GI angle frame and GI sheet cover to the frame and fixing of 2 nos LED tube light fittings 20 watts, connecting electrical supply to the frame with copper wire two core 1.5 Sqmm from nearby electric source including round steel pole minimum 12 feet long of suitable dia for erection on ground with PCC complete all as specified and as directed by Engineer-in-charge. |
| 111 | M&L for cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in foundation, filling in mass concrete etc including necessary use and waste of form work and finishing the exposed surfaces fair and even complete all as specified and as directed by Engineer-in-charge. |
| 112 | Supply and fixing for power contactor 32 Amps, 415 V AC Operated 3 phase ML-1.5 or as per existing complete including taking down the existing complete all as specified and as directed by Engr-in-Charge. |
| 113 | All as per item no 112 above but 70 Amps, ML-4 complete all as specified and as directed by Engr-in-Charge. |
| 114 | All as per item no 112 above but 40 Amps, ML-3 complete all as specified and as directed by Engr-in-Charge. |
| 115 | Supply and fixing in replacement of unserviceable power contactor MNX 50-70 Amps suitable for 30 to 50 HP pumping set complete all as specified and as directed by Engr-in-Charge. |
| 116 | Supply and fixing in replacement of unserviceable power contactor HGS 50-65 Amps suitable for 30 to 50 HP pumping set complete all as specified and as directed by Engr-in-Charge. |
| 117 | Taking down unserviceable pressure pump set & supply, installation, testing and commissioning of pressure pumpset 1 HP with automatic pressure switch which switches the pump on and off based on turning on and off of the Tap, air tank of suitable capacity, pressure gauge etc complete all as specified and as directed by Engineer-in-Charge |
| 118 | S&F in replacement cast iron butterfly valve, ISI mark, flanged ends drilled, with cast iron handle at top complete with nuts, bolts, washers and gaskets including taking out old unserviceable butterfly valve for the 50mm bore size complete all as specified and directed by Engr-in-charge. |
| 119 | All as per item No 118 here-in-before but of size 80mm bore dia complete all as specified and as directed by Engr-in-Charge. |
| 120 | All as per item No 118 here-in-before but of size 100mm bore dia complete all as specified and as directed by Engr-in-Charge. |
| 121 | All as per item No 118 here-in-before but of size 150mm bore dia complete all as specified and as directed by Engr-in-Charge. |
| 122 | Material and Labour for in replacement CI foot valve flanged type including nuts, bolts, washers and rubber upto 150 mm dia conforming to IS-4038 complete all as directed by Engineer-in-Charge. |
| 123 | M&L for taking out UPVC pipe of size 25mm bore dia complete all as specified and as directed by Engr-in-Charge. |
| 124 | M&L for taking out UPVC pipe of size 50mm bore dia complete all as specified and as directed by Engr-in-Charge. |
| 125 | Supply, laying, jointing incl jointing material and testing for leakage UPVC Pipe (SCH-80) of size 25mm bore dia incl all necessary fittings such as bend, tee, elbow, socket etc any type ISI marked complete all as specified and directed by Engr-in-Charge. |
| 126 | Supply, laying, jointing including jointing material and testing for leakage UPVC Pipe (SCH-80) of size 50mm bore dia including all necessary fittings such as bend, tee, elbow, socket etc any type ISI marked complete all as specified and directed by Engr-in-Charge. |
| 127 | Supply and fixing in replacement UPVC Ball valve of size 25 mm bore dia complete including connected items complete all as specified and directed by Engr-in-Charge. |
| 128 | Supply and fixing in replacement UPVC Ball valve of size 50 mm bore dia complete including connected items complete all as specified and directed by Engr-in-Charge. |
| 129 | Supply and fixing in replacement fully automatic starter, 415 Volts 3 Phase, 50 HZ, relay range 13 to 21 Amp having facility for single phase protection, over load, short circuit and phase reversal, suitable for borewell complete all as specified and directed by Engr-in-Charge. |
| 130 | M&L for flushing of existing borewells of size upto 300mm dia, depth upto 200 mtr with drilling compressor including surging and flushing the bore at a pressure of 7 kg/ sqcm minimum 10 hrs, complete with compressed air and flushing the sand, mud etc from the bore well complete all as specified and directed by Engr-in-Charge. Note:- Disconnecting and lifting out of existing submersible pump set from borewell upto 10 HP capacity along with their column pipe and submerssible cable from borewell from any depth and lowering after flushing existing borewell shall be deemed to be included in the item rate. Note:- Log Book shall be maintained with location and machine number. Log Book shall be attached with RAR. |
| 131 | S&F of TP isolator 60 Amp complete all as specified and directed by Engr-in-Charge. |
| 132 | S&F of TPN isolator 40 Amp complete all as specified and directed by Engr-in-Charge. |
| 133 | S&F MCB SPN 32 Amp complete all as specified and directed by Engr-in-Charge. |
| 134 | Supply and fixing in replacement column pipe 100mm dia bore made of meduim grade GI pipe, 10 feet length both ends flanged & drilled including cutting of grooves for submersible cable and fabrication etc complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender