Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #57415618

Tender For Special Repair To Convert Old Overhead Acsr Line Into Lt Underground Cable Alongwith Panels At Certain Locations/Units At Hattigor Under Ge Rangia

Issued by Statutory Bodies & Commissions/Committees · Baksa, Assam
Tender Value
42.36 Lakhs
Estimated cost
Bid Submission
29 Sep 2026
16 days left
EMD
84720
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Baksa → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Convert Old Overhead Acsr Line Into Lt Underground Cable Alongwith Panels At Certain Locations/Units At Hattigor Under Ge Rangia

BOQ

Name of Work:- SPECIAL REPAIR TO CONVERT OLD OVERHEAD ACSR LINE INTO LT UNDERGROUND CABLE ALONGWITH PANELS AT CERTAIN LOCATIONS/UNITS AT HATTIGOR UNDER GE RANGIA
Sl. No. Item Description
1Dismantling of LT over head ACSR conductor of any size removing conductor from site complete all as specified and as directed.
2Dismantling of LT over head insulator of any size and removing the insulator for site complete all as specified and as directed.
3Dismantling of cross arms/clamp/nuts/bolts fixed on Steel tubular poles carefully and removing unserviceable cross arms from site complete all as specified and as directed.
4Dismantling of stay assembly complete (demolition of concrete, etc and excavation measured separately) all as specified and as directed.
5Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft / loose soil complete all as specified and as directed.
6Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil after the pipes/fittings are laid/fixed jointed and tested complete all as specified and as directed.
7Removing excavated material from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5 mtr from the starting point complete complete all as directed as specified.
8M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm including spreading thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.
9Supply and laying sub class B bricks of size 230x125x73mm (+/- 10% tolerance limit) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed.
10Supply, laying, jointing and testing LT underground electric power cable crossed linked XLPE insulated, two or more core galvanized steel strip or wire armoured / PVC insulated armoured cable heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 120 sqmm 3.5 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts or passing through pipes etc fixing and connecting accessories such as Aluminium cable lugs, cable glands, nut, bolts, washers etc complete all as specified and as directed.Note: Excavation, earth work, sand cushioning, protection brick and pipe shall be measured and paid separately under appropriate items.
11All as per item No. 10 here-in-before but of 95 Sqmm, 3.5 Core.
12All as per item No. 10 here-in-before but of 70 Sqmm, 3.5 Core.
13All as per item No. 10 here-in-before but of 25 Sqmm, 3.5 Core.
14All as per item No. 10 here-in-before but of 16 Sqmm, 4 Core.
15All as per item No. 10 here-in-before but of 16 Sqmm, 2 Core.
16All as per item No. 10 here-in-before but of 10 Sqmm, 2 Core.
17Supplying and fixing Galvanised mild steel pipe/tubing, light grade complete with all fittings of 40 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washers as in cable protection complete all as specified and as directed.
18Supplying and fixing Galvanised mild steel pipe/tubing, light grade complete with all fittings of 50 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washers as in cable protection complete all as specified and as directed.
19Supplying and fixing Galvanised mild steel pipe/tubing, light grade complete with all fittings of 80 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washers as in cable protection complete all as specified and as directed.
20M&L for Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 meter below the Road Surface / footpath with the help of GI Tubing not exc. 80mm bore (dia) for passing of UG Cable, complete all as specified and directed. NOTE: GI Pipe laid will be measured and paid separately under appropriate Item.
21Supply and fixed in repair single run 3 core, 1.50 sqmm nominal cross sectional area multistranded copper conductor cable, over all PVC sheathed, 1100 Volts grade confirming to IS-694-2010 (FRLSH) heavy duty cable PVC insulated and PVC sheathed from pole junction box to light fitting complete all as specified and as directed.
22S&F of thermoplastic polycarbonate cable terminal box of size 250 x 200 x 100, IP 66 protection, screw cover top type, suitable for 16 sqmm, 4 core cable, 3P+N incoming/outgoing cable and P+N PVC sheathed connection cable for light fitting, having DIN rail mounting arrangement for holding SPN MCB, with and including SPN MCB 10 Amp, cable junction terminals, IP 55 cable glands of suitable size for cable entry/out and 02 nos of MS clamps and 04 nos of mounting brackets, including all fixing accessories etc, complete all as specified and as directed.
23Supply, installation, testing and commissioning of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Panel Board with raised projected sloped canopy of size 900 X 700 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Digital VAF Meter- 01 Set (Make- L&T/ Schneider/ Legrand/ Siemens), including LED indicating lamps- 03 Nos (Make- L&T/ Schneider/ Legrand/ Siemens), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. The TPN aluminium bus bars of capacity 200 Amps shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator, connected with Aluminium lugs, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following :- (Near ET-697(R&I))(a) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.(b) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job. (c) Bus bar chamber comprising 04 Nos aluminium strip bus bar mounted on DMC ( Dough Moulding Compound) insulator and PVC sheathed of capacity 200 Amps with colour coding for RYB & N - 01 SetINCOMINGL:-(d) MCCB 100 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side- 01 No.OUT GOING:-(e) MCCB 63 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 16KA)Ics=100% of Icu, with Spreader terminal of both side- 01 No. (f) MCB Triple Pole & Neutral (TPN) 16 Amp, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)- 04 No. (g) MCB Single Pole & Neutral (SPN) 40-63 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)- 05 Nos. (h) MCB Single Pole & Neutral (SPN) 20 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)- 04 Nos. (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication).
24Supply, installation, testing and commissioning of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Panel Board with raised projected sloped canopy of size 900 X 700 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Digital VAF Meter- 01 Set (Make- L&T/ Schneider/ Legrand/ Siemens), including LED indicating lamps- 03 Nos (Make- L&T/ Schneider/ Legrand/ Siemens), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. The TPN aluminium bus bars of capacity 200 Amps shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator, connected with Aluminium lugs, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following :- (Panel near ET-209)(a) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.(b) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job. (c) Bus bar chamber comprising 04 Nos aluminium strip bus bar mounted on DMC ( Dough Moulding Compound) insulator and PVC sheathed of capacity 200 Amps with colour coding for RYB & N - 01 SetINCOMING(d) MCCB 100 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side-01 No.OUTGOING(e) MCCB 25 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 16KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. (f) MCB Triple Pole & Neutral (TPN) 16 Amp, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 No. (g) MCB Single Pole & Neutral (SPN) 40-63 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-03 Nos. (h) MCB Single Pole & Neutral (SPN) 20 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-05 Nos. (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication).
25Supply, installation, testing and commissioning of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Panel Board with raised projected sloped canopy of size 700 X 600 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Digital VAF Meter- 01 Set (Make- L&T/ Schneider/ Legrand/ Siemens), including LED indicating lamps- 03 Nos (Make- L&T/ Schneider/ Legrand/ Siemens), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. The TPN aluminium bus bars of capacity 200 Amps shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator, connected with Aluminium lugs, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following :- (Panel near ET-187)(a) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.(b) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job. (c) Bus bar chamber comprising 04 Nos aluminium strip bus bar mounted on DMC ( Dough Moulding Compound) insulator and PVC sheathed of capacity 200 Amps with colour coding for RYB & N - 01 SetINCOMING(d) MCCB 63 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 16KA)Ics=100% of Icu, with Spreader terminal of both side-01 No.OUTGOING (e) MCB Triple Pole & Neutral (TPN) 25 Amp, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)-03 No. (f) MCB Single Pole & Neutral (SPN) 40 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-05 Nos. (g) MCB Single Pole & Neutral (SPN) 25 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-04 Nos.(h) MCB, SPN 240 volt, 6 Amp, breaking capacity of 10 KA. - 01 Nos (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication).
26Supply, installation, testing and commissioning of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Panel Board with raised projected sloped canopy of size 900 X 700 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Digital VAF Meter- 01 Set (Make- L&T/ Schneider/ Legrand/ Siemens), including LED indicating lamps- 03 Nos (Make- L&T/ Schneider/ Legrand/ Siemens), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. The TPN aluminium bus bars of capacity 200 Amps shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator, connected with Aluminium lugs, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following :- (Near ET-114)(a) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.(b) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job. (c) Bus bar chamber comprising 04 Nos aluminium strip bus bar mounted on DMC ( Dough Moulding Compound) insulator and PVC sheathed of capacity 200 Amps with colour coding for RYB & N - 01 SetINCOMING(d) MCCB 100 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side-01 No.OUTGOING(e) MCCB 63 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 16KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. (f) MCB Triple Pole & Neutral (TPN) 25 Amp, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 No. (g) MCB Single Pole & Neutral (SPN) 40 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 Nos. (h) MCB Single Pole & Neutral (SPN) 25 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-04 Nos.(j) MCB Single Pole & Neutral (SPN) 10 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-03 Nos. (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication).
27Supply, installation, testing and commissioning of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Panel Board with raised projected sloped canopy of size 800 X 700 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Digital VAF Meter- 01 Set (Make- L&T/ Schneider/ Legrand/ Siemens), including LED indicating lamps- 03 Nos (Make- L&T/ Schneider/ Legrand/ Siemens), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. The TPN aluminium bus bars of capacity 200 Amps shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator, connected with Aluminium lugs, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following :- (Panel near ET-105)(a) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.(b) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job. (c) Bus bar chamber comprising 04 Nos aluminium strip bus bar mounted on DMC ( Dough Moulding Compound) insulator and PVC sheathed of capacity 200 Amps with colour coding for RYB & N - 01 SetINCOMING(d) MCCB 63 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 16KA)Ics=100% of Icu, with Spreader terminal of both side-01 No.OUTGOING(e) MCB Triple Pole & Neutral (TPN) 25 Amp, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 No. (f) MCB Single Pole & Neutral (SPN) 40 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-03 Nos. (g) MCB Single Pole & Neutral (SPN) 25 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-03 Nos. (h) MCB Single Pole & Neutral (SPN) 10 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 Nos. (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication). Please Enable Macros to View BoQ information
28Supply, installation, testing and commissioning of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Panel Board with raised projected sloped canopy of size 800 X 700 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Digital VAF Meter- 01 Set (Make- L&T/ Schneider/ Legrand/ Siemens), including LED indicating lamps- 03 Nos (Make- L&T/ Schneider/ Legrand/ Siemens), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. The TPN aluminium bus bars of capacity 200 Amps shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator, connected with Aluminium lugs, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following :- (Panel near ET-105)(a) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.(b) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job. (c) Bus bar chamber comprising 04 Nos aluminium strip bus bar mounted on DMC ( Dough Moulding Compound) insulator and PVC sheathed of capacity 200 Amps with colour coding for RYB & N - 01 SetINCOMING(d) MCCB 63 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 16KA)Ics=100% of Icu, with Spreader terminal of both side-01 No.OUTGOING(e) MCB Triple Pole & Neutral (TPN) 25 Amp, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 No. (f) MCB Single Pole & Neutral (SPN) 40 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-03 Nos. (g) MCB Single Pole & Neutral (SPN) 25 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-03 Nos. (h) MCB Single Pole & Neutral (SPN) 10 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 Nos. (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication). Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57415618
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42.36 Lakhs
LAST DATE 29-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Convert Old Overhead Acsr Line Into Lt Underground Cable Alongwith Panels At Certain Locations/Units At Hattigor Under Ge Rangia
Basic Detail
Tender No 8089/RNG/E8
Bidding Type Tender
Location
City Baksa
State Assam
Key Dates
Publish Date 08 Sep 2026
Submission Date 29 Sep 2026
Open Date 05 Oct 2026
Finance
Tender Value 42.36 Lakhs
Tender Fee 500
EMD 84720
Exemption Available
Document List
44e681e2-500e-4d60-8541-154ee853f60f.html
8089TENDERDOCUMENT.pdf
BOQ_883688.xls
Schedule_of_Credit-89.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Oct 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

44e681e2-500e-4d60-8541-154ee853f60f.html

pdf

8089TENDERDOCUMENT.pdf

xls

BOQ_883688.xls

pdf

Schedule_of_Credit-89.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders