Tender For Pirgachi (Dosti More At Nh 34) To Kunor Via Malgaon - Vr Chainage From 0.00 Km To 15.40 Km (Excluding Market Portion - 1250 Mtr), Strengthening And Protection Work Under Uttar Dinajpur Division P.W.D. In The District Of Uttar Dinajpur.
Tender Overview
Project Description
Tender for Pirgachi (Dosti More At Nh 34) To Kunor Via Malgaon - Vr Chainage From 0.00 Km To 15.40 Km (Excluding Market Portion - 1250 Mtr), Strengthening And Protection Work Under Uttar Dinajpur Division P.W.D. In The District Of Uttar Dinajpur.
BOQ
| Sl. No. | Item Description |
| 1 | Pavement WorksMaintenance of Earth Shoulder (stripping excess soil) Stripping excess soil from the shoulder surface to achieve theapproved level and compacting with plate compactor as per the requirement of MORT&H's specification 3003.The earth stripped from earthen shoulders to be dumped on the side slopes locally for disposal. |
| 2 | Construction of Subgrade and Earthen ShouldersConstruction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 (Reference to MoRT&H's specification clause 305).Lead upto 5 km.Land owned and arranged by contractor. |
| 3 | Scarifying Existing Bituminous Surface to a depth of 50 mm by Mechanical MeansScarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material within all lifts and lead upto 1000 metres (Reference to MoRT&H's specification clause 305.4.3). |
| 4 | Excavation in Soil using Hydraulic Excavator CK 90 and Tippers with Disposal upto 1000 metres.Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m (Reference to MoRT&H's specification clause 301). |
| 5 | Medium Sand Filling in Foundation Trenches with good local sand free from earth not exceeding 150 mm compacted thickness including inundating each layer by profuse water and porking and rammimg layer by layer. Quality of sand is to be approved by the Engineer-in-charge.(Reference to MORT&H's specification 304). |
| 6 | Granular Sub-Base with Graded MaterialPlant Mix MethodConstruction of granular sub-base by providing graded material such asnatural sand/crushed gravel/crushedstone/combination depending uponthe required grading spreading inuniform layers with motor grader onprepared surface, mixing byappropriate mechanical mixure (withcontrolled addition of water), and compacting with vibratory roller toachieve at least 98% of the maximumdry density for the materialdetermined as per IS:2720 (Part complete as per clause 401Grading-V Material |
| 7 | Wet Mix MacadamProviding, laying, spreading and compacting graded stone aggregate conforming to the grading of table 400- 13 revised vide table 2 of IRC : 109 (2015) to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density .The thickness of a single compacted layer shall not be less than 75 mm.(Reference to MoRT&H's specification 406. Using Pakur Variety Stone Aggregates.(Payment will be made on the basis of finished compacted volume) |
| 8 | Prime Coat Providing and applying primer coat with cationic bitumen emulsion SS1 grade conforming to IS:8887 on prepared porous granular surface including clearing of road surface and spraying primer using mechanical means (Reference to MORT&H's specification clause 502).On WMM/WBM surface @ 0.85kg /sqm. Using Cationic SS-1 |
| 9 | Tack CoatProviding and applying tack coat with Cationic bitumen emulsion (RS1) complying with IS:8887 using emulsion pressure distributor on the prepared bituminous/granular /cement concrete pavement surface cleaned with mechanical broom and high pressure air jet (Reference to MORT&H's specification clause 503). On bituminous surface @ 0.25kg /sqm Using Cationic RS1 |
| 10 | Tack CoatProviding and applying tack coat with Cationic bitumen emulsion (RS1) complying with IS:8887 using emulsion pressure distributor on the prepared bituminous/granular /cement concrete pavement surface cleaned with mechanical broom and high pressure air jet (Reference to MORT&H's specification clause 503).On Granular surface treated with primer @ 0.275 /sqm. Using Cationic RS1 |
| 11 | Tack CoatProviding and applying tack coat with Cationic bitumen emulsion (RS1) complying with IS:8887 using emulsion pressure distributor on the prepared bituminous/granular /cement concrete pavement surface cleaned with mechanical broom and high pressure air jet (Reference to MORT&H's specification clause 503).On Cement Concrete surface with primer @ 0.325 /sqm. Using Cationic RS1 |
| 12 | Dense Graded Bituminous MacadamProviding and laying dense graded bituminous macadam with 100-120 TPH batch type HMP using crushed aggregates (Pakur variety) of specified grading, premixed with bituminous binder of approved grade @ 4.0% (min) for Grading -1 and 4.5% (min) for Grading -2 by weight of total mix and filler(Cement /hydrated lime / Rock dust ) as per table 500-10 and mix design done as per table 500- 11and job mix formula as per clause 505.3.3 transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory tandem roller and with pneumatic tyre roller of 12 to 15 tonne weight with a pressure at least 0.56 MPa as directed by E-I-C, and to achieve the desired compaction as per MORT&H specification clause No. 505.3.5 complete in all respects (Reference to MORT&H's specification clause 505).For Grading 2 (26.5 mm nominal maximum aggregate size ) Layer compacted thickness 50 mm using Bulk Bitumen VG-30 (Payment will be made on the basis of finished compacted volume) |
| 13 | Bituminous ConcreteProviding and laying bituminous concrete with 100-120 TPH batch type hot mix plant using crushed aggregates (Pakur variety) of specified grading, premixed with bituminous binder of approved grade@ 5.2% (min) for Gr.-1 & @ 5.4% (min) for Gr.-2 , as per table 500-17, and mix design done as per table 500-10 and job mix formula as per cl. 505.3.3 and filler(Cement /hydrated lime / Rock dust ), transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory tandem roller and with pneumatic tyre roller of 12 to 15 tonne weight with a pressure at least 0.56 MPa as directed by E-I-C to achieve the desired compaction as per clause no 507.3.5 complete in all respects ref. to MORTH specification clause No.507.For Grading-2 (13.2 mm nominal maximum aggregate size), Layer compacted thickness:30 mm using Bulk Bitumen VG-30 (Payment will be made on the basis of finished compacted volume) |
| 14 | Supplying and Laying in the particular pattern of cement concrete block pavements with BIS certification and spacer nib of size and shape with aspect ratio as per IS 15658 with cement concrete grade not less than M40 on the prepared base course of specified CBR as mentioned in design and drawing with a cushion of bedding sand of 30 to 50 mm thick (grading of the bedding sand as per clause 6.5.1 of IRC SP-63) and filling up the gaps between two paver block with joint filling sand (the grading of the joint filling sand will be as per clause 6.5.2) complete as per IRC SP - 63 with proper confinement of bedding and joint filling sand, compaction,levelling and filling up of the edge gaps with mortar. Type I, II,III, IV should be as per design requeirment or instruction of E-I-C. Type - II (100 mm thickness) inter locking system |
| 15 | Plain/Reinforced cement concrete in open foundation complete all including vibrating and compacting, finishing, curing, sampling, testing etc. as per drawing and Technical Specifications (Reference to MORT&H's specifications 1500, 1700 & 2200).PCC Grade M20Including FormworkUsing concrete mixture |
| 16 | Water Bound MacadamProviding, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density (Reference to MoRT&H's specification 404). Manual MeansFor 1 cum compacted volume Using 1.09 cum of Jhama Metal (63 mm - 45 mm) and 0.26 cum of Moorum screening. |
| 17 | Boulder Sausage Crate WorksExcavation for StructuresEarth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work (Reference to MoRT&H's specification clause 304).Ordinary soilMechanical Means (Depth upto 3 m)Including Cost of dewatering. |
| 18 | Boulder Apron Laid in Wire CratesProviding and laying of boulder apron laid in wire crates made with 4mm dia wire dia not less than 4mm GI wire conforming to IS: 280 & IS:4826 in 100mm x 100mm mesh Mesh size not more than 150mm (weaved diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 40 kg each ( Tensile strength 300-450mpa, size of wire crates 3.0mx1.50mx1.25 m) (Reference to MORT&H's specification 2503). |
| 19 | Plain/Reinforced cement concrete in sub-structure complete all including vibrating and compacting, finishing, curing, sampling, testing etc. by mechanically mixed as per drawing and Technical Specifications (Reference to MORT&H's specifications 1500, 1700 & 2200).PCC Grade M20Height upto 5mIncluding FormworkUsing concrete mixture |
| 20 | Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification (710.1.4 of IRC:78 & 2200).For 1 cum compacted volume Using 0.72 cum of Brick Aggregates and 0.48 cum of Coarse Sand (Dry loose volume) |
| 21 | Gravity Wall WorksExcavation for StructuresEarth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work (Reference to MoRT&H's specification clause 304).Ordinary soilMechanical Means (Depth upto 3 m)Including Cost of dewatering. |
| 22 | Medium Sand Filling in Foundation Trenches with good local sand free from earth not exceeding 150 mm compacted thickness including inundating each layer by profuse water and porking and rammimg layer by layer. Quality of sand is to be approved by the Engineer-in-charge.(Reference to MORT&H's specification 304). |
| 23 | Plain/Reinforced cement concrete in sub-structure complete all including vibrating and compacting, finishing, curing, sampling, testing etc. by mechanically mixed as per drawing and Technical Specifications (Reference to MORT&H's specifications 1500, 1700 & 2200).PCC Grade M20Height upto 5mIncluding FormworkUsing concrete mixture |
| 24 | Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC/PVC/HDPC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications (Reference to MORT&H's specifications 2706 & 2200). |
| 25 | Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification (710.1.4 of IRC:78 & 2200).For 1 cum compacted volume Using 0.72 cum of Brick Aggregates and 0.48 cum of Coarse Sand (Dry loose volume) |
| 26 | Eucalyptus Bullah Wall and Gunny Bag WorksDrum Sheet Walling 1.40m (av.) high on Sal-bullah / Eucalyptus bullah piling 10 cm dia. and 3.25m long driven 1.75m (av.) below G.L. and 75cm centre to centre including fitting fixing 3 nos. of half bullah pieces (from 10 cm dia) and drum(empty bitumen) sheet (approved condition) of height 1.5m , cutting and straightening drum sheet (each joint must have lap length of min.50mm) including cost of necessary nails, bolts, nuts etc. and providing 2 to 3m long half bullah ties of 10cm dia. @ 2.25 m centre to centre fixed with 10 cm dia. bullah posts driven 1.5m below G.L. including cost of all materials and one coat of coal tarring to all bullah etc. complete as per direction.Using Eucalyptus bullah |
| 27 | Filling empty Cement bags with fine sand, stitching the bags (cost of thread included) and carrying and placing them in position and all incidental charges complete including cost of fine sand and gunny bags. |
| 28 | Road furniture WorksReinforced cement concrete M15 grade kilometre stone of standard design as per IRC:8-1980, fixing inposition including painting and printing etc (Reference to MORT&H's specification 805) 5th kilometre stone (precast) |
| 29 | Reinforced cement concrete M15 grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc (Reference to MORT&H's specification 805) Ordinary kilometer stone (precast) |
| 30 | Reinforced cement concrete M15 grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc (Reference to MORT&H's specification 805) Hectometer stone (precast) |
| 31 | Retro-Reflectorised Traffic SignsProviding and fixing of retroreflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick,when signs with maximum side dimensions do not exceed 600mm, or with aluminium sheeting 2.0mm thick when signs with maximum side dimensions exceeds 600mm, supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing90 cm equilateral triangle |
| 32 | Retro-Reflectorised Traffic SignsProviding and fixing of retroreflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick,when signs with maximum side dimensions do not exceed 600mm, or with aluminium sheeting 2.0mm thick when signs with maximum side dimensions exceeds 600mm, supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing90 cm high octagon |
| 33 | Retro-Reflectorised Traffic SignsProviding and fixing of retroreflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick,when signs with maximum side dimensions do not exceed 600mm, or with aluminium sheeting 2.0mm thick when signs with maximum side dimensions exceeds 600mm, supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing60 cm circular |
| 34 | Retro-Reflectorised Traffic SignsProviding and fixing of retroreflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick,when signs with maximum side dimensions do not exceed 600mm, or with aluminium sheeting 2.0mm thick when signs with maximum side dimensions exceeds 600mm, supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing80 cm x 60 cm rectangular |
| 35 | Direction and Place Identification Signs upto 0.9 sqm Size Board:Providing and erecting direction and place identification retroreflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground y means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing |
| 36 | Direction and Place Identification Signs with size more than 0.9 sqm size Board.Providing and erecting direction and place identification retroreflectorised sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing |
| 37 | Supplying & fixing of Raised Pavement Markers/Road Studs/Cats Eye made of polycarbonate moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face which shall support a load of 13635 kg tested in accordance to ASTM D 4280 Type H and compling to Specifications of Category A of MoR&TH Circular No. RW/NH/33023/10-97 - DO III Dt. 11.06.1997 & MoRT&H's specification for Road &Bridge Works (Fifth Rev.). Marker height shall not be less than 10 mm and shall not exceed 20 mm, width shall not exceed 130mm and with minimum reflective area of 13 sqcm on each side and slope to the base shall be 35 ± 5 degree. Fixing will be without nails but by using epoxy resin based adhesive as per manufacturer's recommendation including site clearence etc and complete as directed by the Engineer in Charge. The contractor will have to provide a test certificate from a reputable national/international laboratory comforming the above specifications. |
| 38 | Metal Beam Crash Barrier Reference to MORT&H's specification 811).Type - A, \\"W\\" : Metal Beam Crash Barrier Providing and erecting a \\"W\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811 |
| 39 | Road Delineators :-Supplying and installation of delineators (road way indicators, hazard markers, object markers), 80- 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and conforming to IRC-79 and the drawings |
| 40 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous SurfaceProviding and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes |
| 41 | Supplying & fixing of Hazard Markers of size : 30cm X 90 cm as per IRC :79-1981 ( The above is inclusive of vertical post) |
| 42 | Raised Profile Edge Markings with Reflectorised Hot Applied Thermoplastic Compound on Bituminous Road surfaces. Providing a laying of Raised Profile Edge Markings with Hot Applied Thermoplastic Road Markings along with Drop on Glass Beads as per the Provisions laid in IRC 35-2015, the height of the rib should be 8 mm for normal roads and it may extend upto 11 mm incase of expressway, the general gap between each rib shall vary between 200- 500 mm, as per the direction of the Engineer in charge. |
| 43 | R.C. Guard postSupplying fitting and fixing R.C. guard post 1.37m long with C.C. 1:2:4 with graded stone chips of 13.2 mm down casting , curing complete including cost of providing 4nos.of 12mm dia. rod of length 1.54m as main reinforcement and 6 nos. of round shaped 8mm dia rods used as binders; the placing of the first binder should be at 75mm below the top finished surface and the other 5 nos of binders should be placed at 245mm c/c ; the guard post is of octagonal section with inscribed circle of dia 24cm at the base tapering to corresponding dimensions of 16cm at the top including two coats of painting with best quality synthetic enamel paint of approved make and grade to form 6 nos. horizontal alternate bands in white/tannery yellow and black to 90 cm length standing up above ground after mending good damages if any during striking off shuttering, making hole in ground of 47cm depth and 30cm. minimum dia, fixing the guard posts in the same holes and repacking the earth properly so as to keep the guard posts standing properly erect in correct position true to line and length including carriage of R. C. Guard Post with due care to the site including loading into the truck and unloading at site complete in all respect.With Pakur variety stone chips |
| 44 | Plain/Reinforced cement concrete in open foundation complete all including vibrating and compacting, finishing, curing, sampling, testing etc. as per drawing and Technical Specifications (Reference to MORT&H's specifications 1500, 1700 & 2200). PCC Grade M15 (Including shuttering)Including FormworkUsing concrete mixture |
| 45 | Surface Drain WorksExcavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material (Reference to MORT&H's specification 304).Ordinary soil Mechanical Means Depth upto 3 mIncluding Dewatering |
| 46 | Medium Sand Filling in Foundation Trenches with good local sand free from earth not exceeding 150 mm compacted thickness including inundating each layer by profuse water and porking and rammimg layer by layer. Quality of sand is to be approved by the Engineer-in-charge. (Reference to MORT&H's specification 304). |
| 47 | Plain/Reinforced cement concrete in open foundation complete all including vibrating and compacting, finishing, curing, sampling, testing etc. as per drawing and Technical Specifications (Reference to MORT&H's specifications 1500, 1700 & 2200). PCC Grade M15 (Including shuttering)Including FormworkUsing concrete mixture |
| 48 | Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications (Reference to MORT&H's specifications 1500, 1700 & 2200). Using concrete Mixer RCC Grade M25 Height upto 5mIncluding Formwork |
| 49 | Supplying, binding, fixing etc. including initial straightening, cutting to requisite length, hooking and bending to correct shape, placing in proper position of uncoated HYSD reinforcement bar in foundation complete as per drawing and Technical Specifications (Reference to MORT&H's specifications 1600 & 2200). |
| 50 | Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC/PVC/HDPC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications (Reference to MORT&H's specifications 2706 & 2200). |
| 51 | 1200 Dia Hume Pipe Culvert WorksDismantling of StructuresDismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metresBy Mechanical MeansDismantling Brick / Tile workIn cement mortar |
| 52 | Dismantling of Flexible PavementsDismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separatelyBy Manual MeansGranular courses |
| 53 | Removing all types of Hume Pipes and Stacking within a lead of 1000 metres including Earthwork and Dismantling of Masonry Works.600 mm to 900 mm dia |
| 54 | Excavation for StructuresEarth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work (Reference to MoRT&H's specification clause 304).Ordinary soilMechanical Means (Depth upto 3 m)Including Cost of dewatering |
| 55 | Fine Sand Filling in Foundation Trenches with good local sand free from earth not exceeding 150 mm compacted thickness including inundating each layer by profuse water and porking and rammimg layer by layer. Quality of sand is to be approved by the Engineer-in-charge.(Reference to MORT&H's specification 304). |
| 56 | Plain/Reinforced cement concrete in open foundation complete all including vibrating and compacting, finishing, curing, sampling, testing etc. as per drawing and Technical Specifications (Reference to MORT&H's specifications 1500, 1700 & 2200).PCC Grade M20Including FormworkUsing concrete mixture |
| 57 | Plain/Reinforced cement concrete in open foundation complete all including vibrating and compacting, finishing, curing, sampling, testing etc. as per drawing and Technical Specifications (Reference to MORT&H's specifications 1500, 1700 & 2200). PCC Grade M15 Including FormworkUsing concrete mixture |
| 58 | Laying Reinforced Cement Concrete Pipe NP4 / Prestressed Concrete Pipe on First Class Bedding in Single Row .Laying Reinforced cement concrete pipe NP4/prestressed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling,concrete and masonry works in head walls and parapets as per the requirements of MORT&H's specification 2900.1200 mm dia |
| 59 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm (Reference to MORT&H's specification 800). |
| 60 | Providing and laying Flooring shall consist 150 mm thick complete as per drawing and Technical specifications laid over cement concrete bedding (Reference to MORT&H's specification. (Cement Concrete blocks Grade M15) |
| 61 | Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification Gradation of filter , Thickness of filter 200/300 mm (Reference to MORT&H's specification 2504).For 1 cum compacted volume Using 0.72 cum of Brick Aggregates and 0.48 cum of Coarse Sand (Dry loose volume) |
| 62 | Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC/PVC/HDPC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications (Reference to MORT&H's specifications 2706 & 2200). |
| 63 | Minor Rehabilitation WorksMaintenance of Culverts Maintenance of Hume pipe Culvert by way of Clearing, Cleaning, Erosion repair, repairs to cracks, parapet wall and protection work as per drawing and technical specification Clause 1908 for Rural Roads of MORD. |
| 64 | Maintenance of Culverts Slab type Maintenance of Slab type Culverts by way of clearing, Cleaning, Erosion repair, repairs to cracks, parapet walls and Protection works as per drawing and technical specification Clause 1908 for Rural Roads of MORD. |
| 65 | Plastering with cement mortar (1:3) on brick work in sub-structure complete all including raking outjoints curing, etc as per Technical Specifications (Reference to MORT&H's specifications 1300 & 2200). |
| 66 | Brick masonry work with 1st class full size bricks except when necessary to complete the bond in cement morter 1:3 in sub-structure complete, including thoroughly soaking the bricks in a tank filled with water for a minimum period of one hour prior to being laid, protecting the green structure from rain by suitable covering and with a minimum Seven days curing etc., but excluding pointing and plastering, as per drawing and Technical.Specifications. (Reference to MORT&H's specifications 1300 &2200) |
| 67 | Painting two coats, after filling the surface & applying a sealing primer, with synthetic enamel paint in all shades on new plastered concrete surfaces as per MORT7H's specification 803.6.2.(Reference to MORT&H's specification 803). |
| 68 | Cleaning the exposed corroded Reinforcement as well as worn out concrete by sand blasting with air compressor including all materials, hire charges of machineries and labour etc. all complete as per technical specification and direction of the Engineer-in-Charge. |
| 69 | Epoxy bonding of new concrete to old concrete ( crack/spalling shall be sealed with epoxy injection/grouting coating of epoxy resin @ 0.80kg /sqm should be applied )(Reference to MORT&H's specification 2805). |
| 70 | Patching of damaged concrete surface with polymer concrete and curing compounds, initiator and promoter, available in present formulations, to be applied as per instructions of manufacturer and as approved by the Engineer (Reference to MORT&H's specification 2800). Thickness of patching = 25mm**This item is a proprietory item available in market as pre-packed polymer concrete and is required to be applied as per instructions of the manufacturer. |
| 71 | Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, with a minimum 10 days curing complete as per approved drawings and technical specifications (Reference to MORT&H's specifications 2703, 1500, 1600 & 1700). |
| 72 | ADD GST @ 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender