Tender For Supply Installation Testing and Commissioning of 6 Passenger Lift Including Allied El Work At Community Hall Of Akanksha Housing Complex Under South Kolkata Electrical Section -I, Hd. --- electrical installation Work.
Tender Overview
Project Description
Tender for Supply Installation Testing and Commissioning of 6 Passenger Lift Including Allied El Work At Community Hall Of Akanksha Housing Complex Under South Kolkata Electrical Section -I, Hd. --- electrical installation Work.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing Sheet steel Main Switches on angle iron frame on wall; 100/125 A, 415V TPN with fuse.(Havells) |
| 2 | Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) Dimension of Cu. Bars [85mm long] 4 x 15x3mm; Dimension of Sheet Metal Box 500x150mm; 4 bars 415 V, 100/125 A |
| 3 | Supplying and fixing double-door (12+2) way SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.INCOMING-Supplying and fixing 240V 40A DP MCB Isolator on din rail of existing DBs and necessary connection. -- 1 Nos.OUTGOING-Supplying and fixing 240V 6-16A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection -- 12 Nos. (Make: Legrand / L&T / Crabtree) |
| 4 | Supplying and fixing 4 Way MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment (Make: Legrand / L&T / Crabtree) |
| 5 | Supplying and fixing 2 Way MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment (Make: Legrand / L&T / Crabtree) |
| 6 | Supplying and fixing 415 V 25A, 30mA 4P RCCB on din rail of existing DBs and necessary connection (Make: Legrand / L&T / Crabtree) |
| 7 | Supplying and fixing 240/415 V 32A DP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make: Legrand / L&T / Crabtree) |
| 8 | Supply of 4 core 50sqmm of 1.1 KV grade alluminium XLPE, PVC/ armoured LT cable( Make : Havells/ Polycab/ Phinolex/ Glowstar ) |
| 9 | Supply of 4 core 16sqmm of 1.1 KV grade alluminium XLPE, PVC/ armoured LT cable( Make : Havells/ Polycab/ Phinolex/ Glowstar ) |
| 10 | Supply of 2 core 10sqmm of 1.1 KV grade alluminium XLPE, PVC/ armoured LT cable( Make : Havells/ Polycab/ Phinolex/ Glowstar ) |
| 11 | Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting |
| 12 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 13 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 14 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. a) 2.5 sqmm |
| 15 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below. a) 2 Core 10 sqmm |
| 16 | b) 4 Core 16 sqmm |
| 17 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. a) 2 Core 10 sqmm |
| 18 | b) 4 Core 16 sqmm |
| 19 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 20 | Supply of 10W LED bulkhead fittings complete with all the necessaries fittings accessories and driver.( Make : Philips / CG / Havells) |
| 21 | Fixing only bulk head ceiling fitting on wall /ceiling by screws etc. |
| 22 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe |
| 23 | Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil |
| 24 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required |
| 25 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe |
| 26 | Connecting the equipments to earth busbar including S & F Copper (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. 4 S.W.G Wire |
| 27 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required a) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 28 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.Average run 9 mtr |
| 29 | Supply & Fixing of 4ft long Single LED Tube Light Fitting (TMC 502 1xT-LED 22W) with 1 nos LED Tube Light 20W,2100lm (Make - Philips, Model -Mas LEDtube 1200mm 18W865 T8 I – 2100lm) or equivalent model of CG/WIPRO/ Havells as approved by EIC/Authority) |
| 30 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 31 | Supply of single LED light 20W, 2000 lm, 15,000 life hours, LED lamp ( Make : Wipro/Philips / Crompton ) |
| 32 | Fixing only pendent light fitting . |
| 33 | Add. G.S.T.@ 18% (on Total from item no 1 to 30) to be calculated by bidder |
| 34 | Add. LWC.@ 1% to be calculated (on total from item no 1 to 30 + GST@18%) by bidder Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender