Public Administrative Department Local Bodies Closing in 5 days TDR #57413282

Tender For The Construction Of Drinking Water Facility Near Birendra Nath Barman House Booth No 3/24 Under Bararangrash Gram Panchayat Under Cooch Behar-Ii Panchayat Samity. ( Activity Id: 117596920 - 2025-26)

Issued by Local Bodies · Coochbehar, West Bengal
Tender Value
3.49 Lakhs
Estimated cost
Bid Submission
17 Sep 2026
5 days left
EMD
6989
Bank guarantee accepted
Document Fee
750
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Coochbehar → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for The Construction Of Drinking Water Facility Near Birendra Nath Barman House Booth No 3/24 Under Bararangrash Gram Panchayat Under Cooch Behar-Ii Panchayat Samity. ( Activity Id: 117596920 - 2025-26)

BOQ

Name of Work:- The Construction of Drinking water facility near Birendra Nath Barman house booth no 3/24 under Bararangrash Gram Panchayat under Cooch Behar-II Panchayat Samity. ( Activity ID: 117596920 - 2025-26)
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge
2Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
3Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
4Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
5Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
6Cement mortar 1:4 (1 cement : 4 coarse sand)
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8
8Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
9Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
10Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
11Columns, Pillars, Piers, Abutments, Posts and Struts
12Shelves (Cast in situ)
13Lintels, beams, plinth beams, girders, bressumers and cantilevers
14Suspended floors, roofs, landings, balconies and access platform
15Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
16Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
1712 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
1820 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
19Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
20Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile
21Precast terrazo tiles 22 mm thick with graded marble chips of sizes upto 12 mm, in skirting and risers of steps not exceeding 30 cm in height, on 12 mm thick cement plaster 1:3 (1 cement : 3 coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of : Dark shade pigment using ordinary cement
22Neat cement punning
23Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
24Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr/10 sqm
25Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes,scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. For100 mm dia
26For 50 mm dia
27Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD -1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross,elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc.fitted including cost of all materials ,jointing materials, cutting pipes,making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe lineincluding all specials No separate payment will be made for accessories, specials.) 100 mm dia
28For 50 mm dia
29Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. 80 MM DIA
30Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer 1000 lt capacity
31Providing and fixing PTMT bib cock of approved quality and colour. 15 mm nominal bore, 90 mm long, weighing not less than 93 gms
32Providing and fixing PTMT stop cock of approved quality and colour. 15 mm nominal bore, 86 mm long, weighing not less than 88 gms
33Chemical and Biological testing of Water sample from GOVT. approved Lab.
34Supply, transport, installation and commissioning of ISI marked as per IS 14286 and IEC 61853(1), 61730(1&2), 61710 certified Solar Module of Multicrystaline/Monocrystalline/ Monocrystalline PERC/bifacial cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2/4.0 mm tempered glass, framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC, should be a minimum of 300 Watt peak, with adequate provision for measurement tolerances. Modules supplied with the SPV system should have warranty for output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be sunplied b) For 2 HP Off-grid Solar Water Pumping System with Monocrystalline/ Monocrystalline PERC/bifacial SPV modules - 2150-2400 Wp.
35Supplying, Fitting Fixing & Installation of Iron Removing Filter Plant Capacity 1500 LPH IR Media Filter Working-Downilow max Flow Rate -3m3/hr Working Pressure-1-3 kg/cm2 Size- 13\\"X54\\" (BIS Standards & Including 1 Year Warranty
36Supply and fixing MC4 Connector for panel loop.
37Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG Gl (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl, drilling holes, with bolts, nuts, washers etc.
38Supply and installation of 3 phase electromotor pump-motor set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading. transportation etc.: ii) 2 HP Open well submersible pump set for PDW with discharge of 5.0-6.0 Lps at 16 mts. total head with, required quantity of flexible delivery pipe( 20m), clamps, cable and all other accessories to complete connection of suction and delivery side.
39Supply, transport, installation and commissioning of IP 54 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 60068-2-Environment Standard safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure. Inverter should have protection against Dry run, Over current, Under current, Over voltage, Under voltage, Short circuit etc. System should be able to run at low sunshine and minimum 7 to 8 hours a day run should be possible during normal sunshine.condition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter eter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Out put AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc. The system should store the data at a set interval, be capable to transfer it to external storage device and support communication of its operational parameters and logs over Modbus protocol. It should also monitor and save total run time, total water pumped etc. There should be provision for interfacing GPRS based data transmission b) For 2 HP capacity Pump-motor set
40Supplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc. i. 4.0 Sq mm single core multi studs - 5m(for 1HP/2HP/3 HP) & 26m(for 5/10 HP)ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57413282
AUTHORITY Local Bodies
TENDER VALUE 3.49 Lakhs
LAST DATE 17-09-2026
Authority
Authority Name Zilla Parishad
Work Description Tender for The Construction Of Drinking Water Facility Near Birendra Nath Barman House Booth No 3/24 Under Bararangrash Gram Panchayat Under Cooch Behar-Ii Panchayat Samity. ( Activity Id: 117596920 - 2025-26)
Basic Detail
Tender No 16/EO/COB-II PS/2026-27
Bidding Type Tender
Location
City Coochbehar
State West Bengal
Key Dates
Publish Date 08 Sep 2026
Submission Date 17 Sep 2026
Open Date 19 Sep 2026
Finance
Tender Value 3.49 Lakhs
Tender Fee 750
EMD 6989
Exemption Not Available
Document List
935d4e8e-a587-4ed7-a8a8-8a5cc572567e.html
BOQ_5105679.xls
Tendernotice_1 (39).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Sep 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

935d4e8e-a587-4ed7-a8a8-8a5cc572567e.html

xls

BOQ_5105679.xls

pdf

Tendernotice_1 (39).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders