Tender For annual rate contract For Supply Installation Testing and Commissioning of Ahu/Csu/Fcu/Scrubber Filters With Hepa Filters Validation At Hbch&Rc, New Chandigarh 140901.
Tender Value
27.51 Lakhs
Estimated cost
Bid Submission
26 Sep 2026
17 days left
EMD
64927
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
S.a.s Nagar → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for annual rate contract For Supply Installation Testing and Commissioning of Ahu/Csu/Fcu/Scrubber Filters With Hepa Filters Validation At Hbch&Rc, New Chandigarh 140901.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Installation, testing and Commissioning of following sizes box/flange type washable filters Aluminium construction Pre filters as per site conditions for 90% down to 10 MIC, G2 as per IS 7613:1973. The filtering media Aluminium channel frame with pleated media 3 layes of HDPE mesh & 2 layers of SS wire mesh to ensure a large dust holding capacity and high performance for Cancer Hospital AHU, CSU,FCU, Kitchen Scrubber and Air washer and Exhaust system etc. Pricing should be with buyback of old/used filters. Atmost care has been taken to prepare details of these filters, however vendor shall check the site and make sure that filters are supplied as per site condtions. Make- Airtech, Thermodyne,Camfil,Frudenburg, AAF and equivalent |
| 2 | Pre filter 610*610*50 |
| 3 | Pre filter 610*305*50 |
| 4 | Pre filter 305*305*50 |
| 5 | Pre filter 475*448*25 |
| 6 | Pre filter 595*528*25 |
| 7 | Pre filter 475*494*25 |
| 8 | Pre filter 675*570*25 |
| 9 | Pre filter 420*461*25 |
| 10 | Pre filter 500*465*25 |
| 11 | Pre filter 360*585*25 |
| 12 | Pre filter 600*555*50 |
| 13 | Pre filter 830*260*50 |
| 14 | Pre filter 830*305*50 |
| 15 | Pre filter 950*330*50 |
| 16 | Electrostatic air filter with scrubber box type pre filter 500*480*25 |
| 17 | FCU filter 275*865*12 |
| 18 | FCU filter 329*798*12 |
| 19 | FCU filter 658*275*12 |
| 20 | Supply, Installation, testing and Commissioning of following sizes washable filters Aluminium constructions fine filters box/ flange type with efficiency 99% @3mic as per site conditions for Cancer Hospital AHU, CSU,FCU, Kitchen Scrubber and Air washer and Exhaust system etc. Initial pressure drop of 6.5 mm of WG, final pr. drop of 20 mm of WG in dirty condition with test dust no G2 as per IS 7613:1973. The filtering media shall be synthetic fabric suitably reinforced, folded into deep pleates and held rigidly by spacer rods to ensure a large dust holding capacity and high performace. Pricing should be with buyback of old/used filters. Atmost care has been taken to prepare details of these filters, however vendor shall check the site and make sure that filters are supplied as per site condtions. Make- Airtech, Thermodyne,Camfil,Frudenburg, AAF and equivalent |
| 21 | Fine Filter 610*610*305 Flange type |
| 22 | Fine Filter 610*305*305 Flange type |
| 23 | Fine Filter 305*305*305 Flange type |
| 24 | Fine Filter 610*305*100 Flange type |
| 25 | Fine Filter 600*555*150 Box type |
| 26 | Fine Filter 830*260*150* Box type |
| 27 | Fine Filter 830*305*150 Box type |
| 28 | Supply, Installation, testing and Commissioningand validation (AHU side and inside OT/ BMT etc)of following sizes Aluminium constructions hepa filters box/ flange type with efficiency 99.99% @0.03mic as per site conditions for Cancer Hospital AHU, CSU,FCU, Kitchen Scrubber and Air washer and Exhaust system etc. Initial pressure drop of 10-15 mm of WG, final pr. drop of 20-50 mm of WG in dirty condition with test dust no G2 as per IS 7613:1973. The filtering media shall be synthetic fabric suitably reinforced, folded into deep pleates and held rigidly by spacer rods to ensure a large dust holding capacity and high performace. Pricing should be with buyback of old/used filters. Atmost care has been taken to prepare details of these filters, however vendor shall check the site and make sure that filters are supplied as per site condtions. The work shall be carried out as per site conditions and as per instructions of Engineer-in-Charge. Efficiency : 99.997% down to 0.03 MicronIPD : 10-15 mm of WC±10%FPD : 25-50 mm of WCCasing : Aluminium ConstructionMedia : Submicronic Glass Fiber PaperSeparators : Hot melt ThreadsGasket : Food GradeSealant : PolyurethaneWashable : NoTemperature : Up to 40 Deg.Make: Airtech, Thermodyne,Camfil,Frudenburg, AAF and equivalent |
| 29 | Hepa Filter 1220*610*69 Box type |
| 30 | Hepa Filter 915*610*69 Box type |
| 31 | Hepa Filter 610*610*69 Box type |
| 32 | Hepa Filter 610*305*69 Box type |
| 33 | Hepa Filter 1200*610*75 Box type |
| 34 | Hepa Filter 870*520*75 Box type |
| 35 | Hepa Filter 520*495*75 Box type |
| 36 | Hepa Filter 610*610*305 Flange type |
| 37 | Hepa Filter 610*305*305 Flange type |
| 38 | HEPA Filter gel type Box type 905*680*105 |
| 39 | HEPA Filter gel type Box type 480*55*105 |
| 40 | HEPA Filter gel type Box type 624*680*105 |
| 41 | Hepa Filter 600*555*300 Box type |
| 42 | Hepa Filter 830*260*300 box type |
| 43 | Hepa Filter 830*305*300 Box type |
| 44 | HEPA Filter gel type 905*680*105 Box type |
| 45 | HEPA Filter 905*680*105 Box type |
| 46 | Supply, Installation, testing and Commissioning of following sizes box/flange type Carbon/charcoal filters with Aluminium construction as per IS/CPWD. These filters will be installed in exhaust system in the hospital. Pricing should be with buyback of old/used filters. Atmost care has been taken to prepare details of these filters, however vendor shall check the site and make sure that filters are supplied as per site condtions. Make- Airtech, Thermodyne,Camfil,Frudenburg, AAF and equivalent |
| 47 | Carbon filter - 7 carbon filter/ candle in one filter housing having approx dia of 120mm and length of 150mm Carbon filter. Size 610x320x150, Flange type |
| 48 | Charcoal Filter 600*555*100 Box type |
| 49 | Charcoal Filter 830*260*100 Box type |
| 50 | Charcoal Filter 830*305*100 Box type |
| 51 | Charcoal Filter 830*260*100 Box type |
| 52 | SCHEDULE OF VALIDATION: It has to be done as per latest guidelines/ ISO/IS on cleanrooms • Inspection of Clean Rooms. • Testing the integrity of HEPA filters. (Using PAO liquid) • Air Velocity measuring. (Using Anemometer) • Air borne particle counts test under static conditions. (Using Particle Counter) • Validation certificate provided as per ISO 14644, WHO, USFDA & MHRA Std. • Validation raw data, SOP, Instrument calibration & Traceability certificate will be provided during validation. |
| 53 | Operation Theatres |
| 54 | BMT Rooms |
| 55 | BMA rooms |
| 56 | ICU/Sterile store/OT Corridore/ IR/Any other area as specified by EIC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysSep 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender