Health and Family Welfare Boards / Undertakings / PSU Closing in 17 days TDR #57407458

Tender For Renovation Of Stores Departments Room No. 58/Ks And 68/Ks At Khanolkar Shodhika (Cri) Building At Actrec

Issued by Boards / Undertakings / PSU · Raigad, Maharashtra
Tender Value
18.28 Lakhs
Estimated cost
Bid Submission
30 Sep 2026
17 days left
EMD
36567
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Raigad → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Of Stores Departments Room No. 58/Ks And 68/Ks At Khanolkar Shodhika (Cri) Building At Actrec

BOQ

Name of Work:- Renovation of stores Departments Room No. 58/KS and 68/KS at Khanolkar Shodhika (CRI) Building at ACTREC
Sl. No. Item Description
1Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2 coats
2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
3Providing and laying gang saw cut 18 mm thick, mirror polished pre-moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. With granite stone of area less than 0.50 sqm.
4Providing & fixing Roller blinds (Premium quality) of approved make with heavy duty roller brackets & necessary fixtures. Warranty for roller mechanism & others accessaries shall be for One year from date of installation. [AS PER SAMPLE AVAILABLE AT SITE] [Payment will be made on actual Mesurement basis. Windows mesurement to be taken before installation of roller blinds for achieving one piece work. ]
5Providing and fixing sun control films 1.5 mil thick garware film on window glasess without damaging rubber gaskets, handle , friction hinged etc complete including neccesary scafolding job is to be complited as per garware film specification and as directed by EIC.
6Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
7WOODEN PARTITION WITH TOUGHEN GLASS : Providing, fabricating, and erecting wooden partition of the required height, partly glazed with 8mm/12 mm thick toughened glass and partly panelled, or fully panelled, as per the approved drawing and as directed by the Engineer-in-Charge. The partition shall consist of a 50 mm × 50 mm teak wood framework placed at approximately 600 mm c/c or as required at site. The panelled portion shall be finished on both sides with 8 mm thick commercial plywood of approved make and quality, complete with 12 mm/16 mm grooves as per approved design.The glazed portion shall be fixed with 8mm/12 mm thick clear toughened glass, secured using 30 mm × 12 mm teak wood beading on both sides, complete with all necessary fittings include all necessary factory-made cut-outs/openings (counter/pass-through openings), drilled holes, notches, and polished edges as required at site for fixing hardware and providing service windows, complete in all respects .The partition shall include 125 mm × 12 mm teak wood skirting on both sides at the bottom and 125 mm × 20 mm teak wood top member/filler to suit the junction between the partition and the wall/ceiling, complete in all respects. The item shall also include a 35 mm thick hollow-core flush door of the required size with 75 mm × 50 mm teak wood door frame, complete with necessary teak wood beading, frosted film (where required), SS hinges, mortise lock with handles, tower bolts, Everite or equivalent door closer, stopper, and all other necessary hardware, fittings, fixtures, consumables, labour, scaffolding, and finishing, complete as directed by the Engineer-in-Charge.
8Providing & fixing 1.5 mm thick approved laminate of required colour over existing surfaces along with the adhesive all as required specification design etc. complete as specified and directed by Engineer-In-Charge
9Providing & fixing approved quality machine pressed phenol formaldehyde bonded commercial/marine plywood of approved size and fixing the same with necessary nails/screws/adhesive in partition cupboard shelves/ktichen cabinets/flush doors etc. at all floors and locations in quantities as required at site in following thickness including 6 mm thick T.W.lipping patti at all exposed edges with nails/screws/hardwares/adhesive wastage in cutting , transportation etc. complete all as directed by the Engineer-In-Charge. 19mm thick ply
10WOODEN CABINET/ Pedistrals/ cupboards 600 mm width Providing & fixing cabinet made up of 19 mm. Commercial ply of approved make for top, bottom, sides & shelves & 8 mm commercial ply approved make for back side Door shutter made up of 19 mm thick commercial ply and outer surfaces and top of shelves for open type cabinet should be laminated with 1.5 mm thick approved plastic laminate sheet of required colour including all brass fittings such as hinges, tower bolts, ball catches, stopper, SS handle 4”, kNosbs ,approved by Engineer-In-Charge etc. and all exposed edges lipping with 6mm Thick T.W. lipping patti locking arrangement with Godrej multipurpose lock etc. all complete as specified & directed by Engineer-In-Charge.( Full height storage and Low height floor mounted storage). Design should be prepared as per actual measurement and get it approved from EIC, ACTREC.
11Providing and fixing in position shelf of required size made of 19mm thick ply of approved make with T.W.lipping patti of 6mm thick of required size to all exposed surface with 1.5mm approved laminated on top of the shelf mounting over the bracket made out of 40mm x 40mm T.W section bracket with french polish to all Nosn laminated surface with bracket.Etc.complete all specified and directed by Engineer-in-Charge.
12COMPUTETR TABLE Providing making & supplying computer table made out fo 19mm commercial ply for table top, mounted on the vertical side fo 19mm commercial ply and cabinet made out of 19mm commercial ply for sides, shelves & shutters making concealed monitor arrangement by providing 8mm thick clear glass on table top of required size with edge polish as shown in drawing drawer and ready made key board drawer with heavy sliding channels with powder coated handle for shutter,cable manager drawers all edges shall be lipped with 6mm thick T.W. lipping patti. All exposed faces should be 1.5mm thk laminate of approved colour and non laminated area should be french polished inclu. cost of other materials labor etc. as per drawing and as specified and directed by Engineer-In-Charge.
13Supply of office revolving chair with synchronic tilt mechanism,any position locking mechanism with adjustable armrest type and arm movement, tilting backrest type with Back Cushion adjustable seat height (from 75 to 90 cm) 110 KGS weight capacity Seat material is Leather, 360-degree swivel; chrome arched base with heavy-duty, dual-wheel casters for smooth maneuverability; Supportive back cushion measures 16.5 by 10.2 inches (WxH), sturdy foot rest all complete as specified & directed by Engineer-In-Charge. One Sample of CHAIR shall be supplied if any modification is required in the sample shall be implemented at quoted cost only not extra cost to be born by ACTREC.
14Flush door with vision panel (fixed on hinges with mortise lock) (Size 900 mm L X 2400 MM h Providing & fixing in position door with frame of second class indian teak wood of size 100 x 50 mm & solid core waterproof flush door shutter of 35 mm thick & finished with 1 mm thick laminate of approved colour & texture on both sides & second class teak wood lipping of size 35 x 12 mm on edges of shutter. The shutter shall be provided with a vision panel of size 450 x 450mm using glass of 8 mm thick ( plain with option of etching) fixed with second class indian teak wood beading of size 19 x 12 mm on both sides. Door shall be fixed using SS brush finish brass butt hinges of size 100 x 75 mm x 3 mm & provided with a surface mounted hydralic door closer, SS matt finish concealed mortise lock case with lever handle, 1 no 450 mm tower bolt, pvc door buffer & SS brush finish door stopper. All exposed second class indian teak wood lipping & frame shall be finished with 2 to 3 coats of french polish (matt/gloss) to match the colour / shade of the laminate till the require finish is achieved. All material shall be of approved make. All works shall be completed as per the drawing, specification & direction of EIC.
15Dismantling/Removing of existing furnitures including all the components such as tables,storage units,chairs, pedistrials etc. and stacking the serviceable material anywhere in the campus Removing clearing the site complete,carting away all materials out of the hospital as directed by engineer in chargeas directed by EIC.
16Floor polishing : Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete as dircted by engineer in charge.
17Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width.
18Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
19Providing & laying poly vinyl chloride (PVC) rolls flooring manufactured of approved make and approved pattern for flooring, skirting/dado laid on existing cement tile or concrete of plastered floor finish with suitable adhesive as per manufacturers specifications close jointed and finished to proper bends, slopes and plumbs as directed etc. complete generally as per manufacturer’s specifications. 2 mm thick PVC flooring.
20Core Cutting for holes upto 100 mm in size clean with cleaning of debris and carting it away from ACTREC premises or dumping as per the instructions of engineer- in charge. Cleaning of dust caused due to core cutting is also in the scope of contractor.
21Dismantling old external anad internal plaster or skirting raking out joints and cleaning the surface for plaster including disposal disposal of unserviceable material outside ACTREC campus as per direction of Engineer-in-charge.
22Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
23Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
2415 mm cement plaster of mix for wall with ready mix plaster wherever required as per the instructions of Engineer incharge
25S.S. SINK: - Providing and fixing in position Stainless Steel sink with drain board or without drain board of Nirali make only resting over bracket with waste coupling including fabricating bracket from 'B' class GI pipe with necessary welding, chiselling in wall and fixing the sink in position with waste coupling, bottle trap all complete as per the specified and directed by engineer-in charge.510mm x432mm Medium x 190mm
26Providing & fixing approved make heavy quality C.P. brass screw down pillar tap with jam nut easy clean variety of 15 mm n.b. etc. complete all as directed by the Engineer-In-Charge (work includes removing old fittings and fixtures and handing over the same)Long Nose : Not LESS THAN 810 Gms
27S.S. waste coupling of required size of S.S. sink of Nirali make.
2875mm pvc pipe
29Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:
30Providing and fixing Wall cladding of made out of PVC fluted panels of wooden finish with grooves, approved pattern and colour as directed by engineer in charge.
31Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, 12.5 mm thick tapered edge gypsum moisture resistant board. shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge.12.5 mm thick tapered edge gypsum moisture resistant board.
32DEBRIS REMOVING: Removal of debris/murrum/stones etc. from ACTREC.premises including clearing the site/sweeping complete,carting away all materials out of the hospital premisesas specified & directe by the engineer incharge.
33Dismatling FCU including piping, valve station, cabling , drain etc as per instruction and as directed by OIC-ES
34Re-installtion of FCU with valve station ,cables,grills etc as per instruction and as directed by OIC-ES
35Chilled water piping PPR-CT (FCU units)SITC of PP-RCT (PPR-CT) piping for chilled water circulation.The PP-RCT piping shall conform to ISO 15874 and DIN 8077/8078 standards and shall be manufactured from pressure-rated PP-RCT material of minimum PN 20 rating. Pipes and fittings shall be sourced from the same manufacturer and joined by thermal socket fusion using approved fusion tools; threaded joints shall be permitted only at equipment, valve, and accessory connections using suitable transition fittings with brass inserts. Adequate supports, anchors, guides, and expansion provisions shall be provided in accordance with the manufacturer's recommendations. All chilled water piping shall be insulated with closed-cell elastomeric insulation of minimum 19 mm thickness with GC cloth for pipes hydrostatically tested at 1.5 times the working pressure and maintained for a minimum of two hours without any leakage or pressure loss before insulation and commissioning. Note:- Piping to be laid down in cable tray.25 mm PPRCT piping or equivalent to 1.0 TR FCU
36Supply, Installation, Testing and commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping complete with fittings(elbows, tees, reducers,sockets,u trap etc.) supports, jointing insulated with XLPE class O tubular insulation and any other item required to make the system complete. Nominal diameters of pipe in mms as indicated below:25 mm dia pipe, Insulation thickness - 19 mm
37Supply & installation of PVC conduit to run piping , cable, drain piping etc. 5\\" size or as per requirement
38Supply & installation of Condensate drain pump Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57407458
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 18.28 Lakhs
LAST DATE 30-09-2026
Authority
Authority Name Tata Memorial Centre
Work Description Tender for Renovation Of Stores Departments Room No. 58/Ks And 68/Ks At Khanolkar Shodhika (Cri) Building At Actrec
Basic Detail
Tender No ZS/ET-46/Renovation of Stores/2026
Bidding Type Tender
Location
City Raigad
State Maharashtra
Key Dates
Publish Date 08 Sep 2026
Submission Date 30 Sep 2026
Open Date 01 Oct 2026
Finance
Tender Value 18.28 Lakhs
Tender Fee Ref. Documents
EMD 36567
Exemption Not Available
Document List
164afc3b-5140-4517-9a5e-7c06302a8a99.html
AnnexureForm.xls
BOQ_972371.xls
TDET46.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Oct 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

164afc3b-5140-4517-9a5e-7c06302a8a99.html

xls

AnnexureForm.xls

xls

BOQ_972371.xls

pdf

TDET46.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders