Tender For Improvement Of Tubular Structure Barrack Under Occupation Of 97 Bn Bsf (Used As Jawan Barrack, Kote, Signal Centre, Coy Office & Cqmh Store) At Bop Rangna Under Shq Shq Panisagar.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Sep 2026
4 days left
EMD
11988
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Improvement Of Tubular Structure Barrack Under Occupation Of 97 Bn Bsf (Used As Jawan Barrack, Kote, Signal Centre, Coy Office & Cqmh Store) At Bop Rangna Under Shq Shq Panisagar.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (i) (Group B) |
| 2 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 3 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. i) 3 x 1.5 sq. mm |
| 6 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. i) 5/6 amps switch |
| 7 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. ii) 3 pin 5/6 amp socket outlet |
| 8 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 10 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 11 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 12 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) i) 16 way, Double door (Havells/Legrand/Indoasian/L&T make) |
| 13 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Havells/Legrand/Indoasian/L&T make) i) Single pole |
| 14 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Havells/Legrand/Indoasian/L&T make) ii) Double pole |
| 15 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 16 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. |
| 17 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 18 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 19 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 20 | Providing installation testing and commissioning of ISI marked ceiling fans of 1200 mm sweep, capacitor type with double ball bearing complete with capacitor, 300 mm down rod, canopies,with 1.5 sqmm FR PVC indulsted, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required suitable for single phase, AC 230 Volt, 50Hz supply. |
| 21 | Supplying and fixing of pvc holder along with energy efficient 10 Watt LED bulb suitable for PVC batten/ angle holder etc. as required. |
| 22 | Supplying, installation , testing and commissioning of energy efficient pre wired LED tubelight of 20 W LED tube, decorative slim liner LED batten, polycarbonate housing & integrated electronic driver. ceiling surface mounted/suspention type, completed with all accessories inc etc. as required. |
| 23 | Supplying, installation, testing & commissioning of following pre-wired ,LED type street light fittings, complete with all accessories, and 32 mm dia(nominal) 'B' class GI pipe bracket, reduser for mounting fitting on wall including bending the pipe to the required shape, and connections with 3 x 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. a) 70 W LED Street light luminaire with power LEDs. (Make- havells/philips/Syska/ Halonix/CG) |
| 24 | Supplying & laying of one number XLPE insulated and PVC sheathed Armoured power cable of 1.1 KV grade of size 2 x 25 sqmm, direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering Conf. to IS:7098 part - I of make Havells / Polycab / finolex / Gloster/KEI or equivalent. |
| 25 | Supplying & laying of one number XLPE insulated and PVC sheathed Armoured power cable of 1.1 KV grade of size 2 x 25 sqmm, in the existing masonry open duct as required.(IS:7098 part - I |
| 26 | Supplying & laying of G.I. pipe of 40 mm dia (medium duty ) G.I pipe in floor/wall/road for protection of UG cable including cutting the wall/floor/metalled road and making good the same as required. Make Jindal/ TATA/ Bansal/ Hindustan/equivalent. |
| 27 | Dismantling of existing fitting fixture and accessories, switch board, distribution board, etc in Jawan Barrack including making good the damage etc complete as reqd Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents