Water Resources and Irrigation Government Departments Closing in 10 days TDR #57407353

Tender For Restoration Of Rain Damages Lwss Bountra In Section Kuthar Under Js Sub-Division Chandi In Tehsil Kasauli Distt. Solan (Hp) (Sh:- supply erection Of Centrifugal Pumping Machinery (10 Hp) Along With Allied Accessories) Sanction Id-9208) Und

Issued by Government Departments · Solan, Himachal Pradesh
Tender Value
1.40 Lakhs
Estimated cost
Bid Submission
18 Sep 2026
10 days left
EMD
2800
Bank guarantee accepted
Document Fee
350
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Solan → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Restoration Of Rain Damages Lwss Bountra In Section Kuthar Under Js Sub-Division Chandi In Tehsil Kasauli Distt. Solan (Hp) (Sh:- supply erection Of Centrifugal Pumping Machinery (10 Hp) Along With Allied Accessories) Sanction Id-9208) Under Pdna

BOQ

Name of Work:- Restoration of rain damages LWSS Bountra in section Kuthar under JS Sub-Division Chandi in Tehsil Kasauli Distt. Solan (HP) (SH:- S/E of centrifugal pumping machinery (10 HP) along with allied accessories) sanction ID-9208) Under PDNA
Sl. No. Item Description
1Providing Installation i/c testing and commissioning at site horizontal spindle horizontal split casing/end suctions (back full out arrangement) single/double/ multistage centrifugal pump or combination of pump in series of recommended make such as Crompton greaves /Mather and Platt/ KSB/ Kirloskar /Becon weir/BE/Jyoti as per IS-1520-1980 / IS 5659 - 1970 with up to date amendments, read with IS: 9137-1978 or latest edition suitable for lifting clear / raw water for under mentioned characteristics with bronze impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate ( base plate to be from the manufacturers of the pumping unit only) to Squirrel Cage / Slipring drip proof induction motor of standard make such as Kirloskar /Crompton /Bhel/NGEF/GEC/Siemen/Jyoti/ABB and suitable for operation on 400 (+)/-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be at least 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 25% of the duty point head. The motor should be as per IS: 325-1978 with up to date amendments read with IS: 900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:-
2Discharge (Q) : - 1.000 LPS
3Total dynamic head : 110.00 mtrs.
4(a) LWL in sump well (h) :
5(b) Shaft level :
6(c ) Level at discahrge point :
7(d) Suction lift :
8(e) Residual head :
9(f) Static head :
10(i) Rising Main :
11(a) Length 270 Mtrs
12(b) Dia. :40 mm
13(iv) Pumping Hours : 8 Hours.
14Altitude of installation above MSL:-
15Characteristic of Water
16Temperature:-
17Ambient
18Alkalinity :- Mg/CaCo3
19Size of the Solids (mm)
20Other
21(Including following accessories)
22Providing ICTP Main Switch with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB.
23Providing M.S. sheet, steel fabricated floor mounted closed (Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
24Providing Installation i/c testing and commissioning at site A.C.B./ OCB of Kilburn/ Havell/MDS/Standard/ L&T/MEI/GEC make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
25Providing Installation i/c testing and commissioning at site A.C.B./ OCB of Earth leakage circuit breaker of Havell/MDS/INDETEC/kilburn/L&T/MEI/GEC make as per IS: 2516-1977 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
26The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and iii electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part II) 1983 (Latest edition).
27100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part II)-1978 with up to date amendments.
28Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part V) 1983 (Latest edition with up to date amendments of suitable rating
29Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part IV) 1983 (Latest edition) with up to date amendments of suitable rating.
30Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of (e) full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments.
31ICTP switches HRC of L&T/ with Standard/Havells/Crompton/kilburn/Siemens make and of suitable fuses capacity as per IS: 4064 (Part II) -1978 with up to date amendments.
32Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 (P-I & II) with up to date amendments.
33100mm Square type AC supply Ammeter of AE/L&T Rishab make of suitable range with selector switches and CTS operated as per IS: 1248 (P-II) 1983 with up to date amendments. Capacitor of L&T/Bajaj/Assian/Crompton make as per IS:2834-1986 with up to date amendments.
34Capacitor of L&T/Bajaj/Assian/Crompton make as per IS:2834-1986 with up to date amendments raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVAr rating according to HP offered including cables as per relevant ISI code (of Siemens/Glocter/IEC make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part II) 1978 with upto date amendments
35Providing Installation i/c testing and commissioning at site suitable oil immersed star delta/ direct on line/Auto trasformer/ starter rotor starter of MEI/ Kilburn/Jyoti/ L&T/ Siemens make as per IS: 8544 - 1979 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments
36Providing Hour run meter or recommended make of suitable capaciy as per IS: 722 (Latest edition)
37Providing double flanged cast Iron sluice valve of Leader/Kirloskar make of 50mm dia for the suction pipe and capable of withstanding the normal seat pressure as per IS: 780-1984 with up to date amendments.
38P/F double flanged cast steel sluice valve of Kirloskar/KSB/Leader make and of class-300 for rising main and capable of with standing normal seat pressure as per relevant IS specifications with upto date amendments including rubber, gaskets, nuts and bolts complete in all respect and to the entire statisfaction of Engineer-in-Charge (40 mm dia).
39P/F double flanged cast steel swing type non return valves class-300 and of leader/ KSB/Kirloskar make on delivery line capable of with standing the normal seat pressure per relevant IS code with upto date amendments including rubber, gaskets, nuts and bolts complete in all respect and to the entire statisfaction of Engineer-in-Charge 40 mm dia complete in all respect.
40Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/GICO/Grandly/National make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor complete in all respects. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57407353
AUTHORITY Government Departments
TENDER VALUE 1.40 Lakhs
LAST DATE 18-09-2026
Authority
Authority Name Irrigation And Public Health Department
Work Description Tender for Restoration Of Rain Damages Lwss Bountra In Section Kuthar Under Js Sub-Division Chandi In Tehsil Kasauli Distt. Solan (Hp) (Sh:- supply erection Of Centrifugal Pumping Machinery (10 Hp) Along With Allied Accessories) Sanction Id-9208) Under Pdna
Basic Detail
Tender No NIT No. 19383-19483 Dt. 08-09-2026
Bidding Type Tender
Location
City Solan
State Himachal Pradesh
Key Dates
Publish Date 08 Sep 2026
Submission Date 18 Sep 2026
Open Date 18 Sep 2026
Finance
Tender Value 1.40 Lakhs
Tender Fee 350
EMD 2800
Exemption Not Available
Document List
a3353263-b585-4d6e-aa99-07c47602e785.html
BOQ_212386.xls
PWD6.pdf
PWD8.pdf
TandC.pdf
Tendernotice_1 (19).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 08, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Sep 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Sep 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

a3353263-b585-4d6e-aa99-07c47602e785.html

xls

BOQ_212386.xls

pdf

PWD6.pdf

pdf

PWD8.pdf

pdf

TandC.pdf

pdf

Tendernotice_1 (19).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders