Power Government Departments Closing in 17 days TDR #57406841

Tender For Replacement Of Existing Acsr Zebra Conductor By Htls Conductor ( To Carry Minimum Current 1200 A) I.R.O 220 Kv Transmission Lines -1. Jeerat -Barasat D/C (Ckm= 42.00);2. Ktpp-Food Park D/C (Ckm= 104.00); 3. Jangalpur-Food Park D/C (Ckm= 12

Issued by Government Departments · 24 Paraganas North, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
05 Oct 2026
17 days left
EMD
1.50 Crore
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Existing Acsr Zebra Conductor By Htls Conductor ( To Carry Minimum Current 1200 A) I.R.O 220 Kv Transmission Lines -1. Jeerat -Barasat D/C (Ckm= 42.00);2. Ktpp-Food Park D/C (Ckm= 104.00); 3. Jangalpur-Food Park D/C (Ckm= 12.00); 4. Subhasgram Pgcilsubhasgram Wbsetcl D/C Along With Replacement Of 220 Kv Two Main & One Transfer Bus Conductors At Subhasgram Wbsetcl Substation (Ckm=02.50); 5. Durgapur 220-Shayam Sel S/C (Ckm=34.9); 6.Durgapur 220-Mongalpur S/C (Ckm=31.08) And Allied Works On Turn-Key Basis.

BOQ

Name of Work:- Replacement of existing ACSR Zebra conductor by HTLS conductor ( to carry minimum current 1200 A) i.r.o 220 kV Transmission Lines -1. Jeerat -Barasat D/C (CKM= 42.00);2. KTPP-Food Park D/C (CKM= 104.00); 3. Jangalpur-Food Park D/C (CKM= 12.00); 4. Subhasgram PGCILSubhasgram WBSETCL D/C along with replacement of 220 kV Two Main & One Transfer Bus Conductors at Subhasgram WBSETCL Substation (CKM=02.50); 5. Durgapur 220-SHAYAM SEL S/C (CKM=34.9); 6.Durgapur 220-Mongalpur S/C (CKM=31.08) and allied works on turn-key basis.
Sl. No. Item Description
1HTLS conductor
2Replacement of existing ACSR Zebra conductor by HTLS conductor (to carry minimum current 1200 A) i.r.o1. Jeerat -Barasat D/C (CKM= 42.00)2. KTPP-Food Park D/C (CKM= 104.00)3. Jangalpur-Food Park D/C (CKM= 12.00)4. Subhasgram PGCILSubhasgram WBSETCL D/C along with replacement of 220 kV Two Main & One Transfer Bus Conductors at Subhasgram WBSETCL Substation (CKM=02.50)5. Durgapur 220-SHAYAM SEL S/C (CKM=34.9)6.Durgapur 220-Mongalpur S/C (CKM=31.08)
3220 kV, Jeerat - Barasat D/C Transmission Line (CKM= 42.00)
4220 kV KTPP-Food Park D/CTransmission Line(CKM= 104.00)
5220 kV Jangalpur-Food Park D/C Transmission Line (CKM= 12.00)
6220 KV Subhasgram (PGCIL) -Subhasgram (WBSETCL) D/C Transmission Line with the Replacement of Existing ACSR Conductor of 220 kV
7220 kV Durgapur 220 kV - SHYAM SEL S/C Transmission Line (CKM= 34.90)
8220 kV DURGAPUR 220KV - MONGALPUR 220 KV S/C Transmission Line (CKM= 31.08)
9Solid Carbon Composite core HTLS Conductor for as per Technical Specification
10Solid Carbon Composite core HTLS Conductor to carry minimum current of 1200A for 220 kV, Jeerat - Barasat D/C Transmission Line (CKM= 42.00), as per technical specification
11Above HTLS Conductor -as SPARE
12Hardware Fittings and Clamp & Connector for above HTLS Conductor, as per Technical Specification
13Compression type Tension Clamp (Dead End Assembly) suitable to match with the Existing SingleTension Hardware Fittings Complete.
14Compression type Tension Clamp (Dead End Assembly) suitable to match with the Existing Double Tension Hardware Fittings Complete.
15Suspension Clamp suitable to match with the existing Single Suspension Hardware Fittings Complete.
16Suspension Clamp suitable to match with the existing Double Suspension Hardware Fittings Complete.
17Vibration Damper
18Suspension Clamp suitable to match with the existing Pilot Suspension Hardware Fittings Complete.
19Compression type T-Connector suitable for above HTLS conductor to Existing ACSR Conductor
20Compression type connector for CT Stud to HTLS Conductor
21T-Type,Terminal Connector for 220 kV AIR Bushing Stud (80- MM DIA) to HTLS Conductor
22Compression type T-Connector suitable for above HTLS conductor to above HTLS Conductor
23T-Connector suitable for above HTLS conductor to PAD
24Hardware Fittings and Clamp & Connector for above HTLS Conductor, as per Technical Specification- as SPARE
25Compression type Tension Clamp (Dead End Assembly) suitable to match with the Existing Single Tension Hardware Fittings Complete.
26Compression type Tension Clamp (Dead End Assembly) suitable to match with the Existing Double Tension Hardware Fittings Complete.
27Suspension Clamp suitable to match with the existing Single Suspension Hardware Fittings Complete.
28Suspension Clamp suitable to match with the existing Double Suspension Hardware Fittings Complete.
29Vibration Damper
30Suspension Clamp suitable to match with the existing Pilot Suspension Hardware Fittings Complete.
31Compression type T-Connector suitable for above HTLS conductor to Existing ACSR Conductor
32Compression type connector for CT Stud to HTLS Conductor
33Mid Span Compression Joint
34Compression Type Repair Sleeve
35T-Type,Terminal Connector for 220 kV AIR Bushing Stud (80- MM DIA) to HTLS Conductor
36Compression type T-Connector suitable for above HTLS conductor to above HTLS Conductor
37T-Connector suitable for above HTLS conductor to PAD
38Dismantling of Existing ACSR conductor with hardware fittings in 220 kV, Jeerat - Barasat D/C Transmission Line and handing over the same at WBSETCL Store as per direction of E-I-C.
39Erection of supplied HTLS conductor with hardware and accessories in the above Line as per Technical Specification.(All Road Crossings/ Building crossings are to be erected with the Double Tension /Suspension Fittings as per the direction of E-I-C)
40Solid Carbon Composite core HTLS Conductor as per Technical Specification
41Solid Carbon Composite core HTLS Conductor to carry minimum current of 1200A for 220 kV KTPP-Food Park D/CTransmission Line(CKM= 104.00), as per technical specification.
42Above HTLS Conductor -as SPARE
43Hardware Fittings and Clamp & Connector for above HTLS Conductor, as per Technical Specification
44Compression type Tension Clamp (Dead End Assembly) suitable to match with the Existing Single Tension Hardware Fittings Complete.
45Compression type Tension Clamp (Dead End Assembly) suitable to match with the Existing Double Tension Hardware Fittings Complete.
46Suspension Clamp suitable to match with the existing Single Suspension Hardware Fittings Complete.
47Suspension Clamp suitable to match with the existing Double Suspension Hardware Fittings Complete.
48Vibration Damper
49Suspension Clamp suitable to match with the existing Pilot Suspension Hardware Fittings Complete.
50Compression type T-Connector suitable for above HTLS conductor to Existing ACSR Conductor
51Compression type connector for CT Stud to HTLS Conductor
52T-Type,Terminal Connector for 220 kV AIR Bushing Stud (80- MM DIA) to HTLS Conductor
53Compression type T-Connector suitable for above HTLS conductor to above HTLS Conductor
54Compression type T-Connector suitable for HTLS Conductor to 3 Inch AL Bus Pipe
55Hardware Fittings and Clamp & Connector for above HTLS Conductor, as per Technical Specification- as SPARE
56Compression type Tension Clamp (Dead End Assembly) suitable to match with the Existing Single Tension Hardware Fittings Complete.
57Compression type Tension Clamp (Dead End Assembly) suitable to match with the Existing Double Tension Hardware Fittings Complete.
58Suspension Clamp suitable to match with the existing Single Suspension Hardware Fittings Complete.
59Suspension Clamp suitable to match with the existing Double Suspension Hardware Fittings Complete.
60Vibration Damper
61Suspension Clamp suitable to match with the existing Pilot Suspension Hardware Fittings Complete.
62Compression type T-Connector suitable for above HTLS conductor to Existing ACSR Conductor
63Compression type connector for CT Stud to HTLS Conductor
64Mid Span Compression Joint
65Compression Type Repair Sleeve
66T-Type,Terminal Connector for 220 kV AIR Bushing Stud (80- MM DIA) to HTLS Conductor
67Compression type T-Connector suitable for above HTLS conductor to above HTLS Conductor
68Compression type T-Connector suitable for HTLS Conductor to 3 Inch AL Bus Pipe
69Dismantling of Existing ACSR conductor with hardware fittings in 220 kV KTPP-Food Park D/C Transmission Line and handing over the same at WBSETCL Store as per direction of E-I-C.
70Erection of supplied HTLS conductor with hardware and accessories in the above Line as per Technical Specification.(All Road Crossings/ Building crossings are to be erected with the Double Tension /Suspension Fittings as per the direction of E-I-C)
71Solid Carbon Composite core HTLS Conductor as per Technical Specification
72Solid Carbon Composite core HTLS Conductor to carry minimum current of 1200A for 220 kV, Jangalpur-Food Park D/C Transmission Line (CKM= 12.00) , as per technical specification.
73Above HTLS Conductor -as SPARE
74Hardware Fittings and Clamp & Connector for above HTLS Conductor, as per Technical Specification
75Compression type Tension Clamp (Dead End Assembly) suitable to match with the Existing Single Tension Hardware Fittings Complete.
76Compression type Tension Clamp (Dead End Assembly) suitable to match with the Existing Double Tension Hardware Fittings Complete.
77Suspension Clamp suitable to match with the existing Single Suspension Hardware Fittings Complete.
78Suspension Clamp suitable to match with the existing Double Suspension Hardware Fittings Complete.
79Vibration Damper
80Suspension Clamp suitable to match with the existing Pilot Suspension Hardware Fittings Complete.
81Compression type T-Connector suitable for above HTLS conductor to Existing ACSR Conductor
82Compression type connector for CT Stud to HTLS Conductor
83T-Type,Terminal Connector for 220 kV AIR Bushing Stud (80- MM DIA) to HTLS Conductor
84Compression type T-Connector suitable for above HTLS conductor to above HTLS Conductor
85Compression type T-Connector suitable for HTLS Conductor to 3 Inch AL Bus Pipe
86Hardware Fittings and Clamp & Connector for above HTLS Conductor, as per Technical Specification- as SPARE
87Compression type Tension Clamp (Dead End Assembly) suitable to match with the Existing Single Tension Hardware Fittings Complete.
88Compression type Tension Clamp (Dead End Assembly) suitable to match with the Existing Double Tension Hardware Fittings Complete.
89Suspension Clamp suitable to match with the existing Single Suspension Hardware Fittings Complete.
90Suspension Clamp suitable to match with the existing Double Suspension Hardware Fittings Complete.
91Vibration Damper
92Suspension Clamp suitable to match with the existing Pilot Suspension Hardware Fittings Complete.
93Compression type T-Connector suitable for above HTLS conductor to Existing ACSR Conductor
94Compression type connector for CT Stud to HTLS Conductor
95Mid Span Compression Joint
96Compression Type Repair Sleeve
97T-Type,Terminal Connector for 220 kV AIR Bushing Stud (80- MM DIA) to HTLS Conductor
98Compression type T-Connector suitable for HTLS Conductor to 3 Inch AL Bus Pipe
99Dismantling of Existing ACSR conductor with hardware fittings in 220 kV Jangalpur-Food Park D/C Transmission Line and handing over the same at WBSETCL Store as per direction of E-I-C.
100Erection of supplied HTLS conductor with hardware and accessories in the above Line as per Technical Specification.(All Road Crossings/ Building crossings are to be erected with the Double Tension /Suspension Fittings as per the direction of E-I-C)
101Solid Carbon Composite core HTLS Conductor as per Technical Specification
102TWIN HTLS Conductor (each conductor to carry minimum current of 1200A.) for 220 KV Subhasgram (PGCIL) -Subhasgram (WBSETCL) D/C Transmission Line including 220 kV, 2 (Two) Main Bus and 01 (One)Transfer Bus. Remarks: Circuit consisting of 3 Phase with Twin HTLS Conductor in each Phase
103Hardware Fittings and Clamp & Connector for above HTLS Conductor, as per Technical Specification
104Compression type Tension Clamp (Dead End Assembly) suitable to match with the Existing Single/Double Tension Hardware Fittings Complete suitable for Twin HTLS Conductor.
105Suspension Clamp suitable to match with the existing Single/Double Suspension Hardware Fittings Complete suitable for Twin HTLS Conductor.
106Vibration Damper
107Compression type T-Connector suitable for above HTLS conductor to HTLS Conductor
108Spacer for Twin HTLS
109Compression type connector for Single HTLS conductor to 40mm Dia Isolator Stud
110Compression type connector for Single HTLS conductor to 30 mm Dia CT Stud
111Compression type connector for Single HTLS conductor to 40mm Dia CT Stud
112Compression type connector for Single HTLS conductor to 3 Inch IPS
113Compression type connector for Single HTLS conductor to Twin HTLS Conductor-T-type
114Compression type connector for Single HTLS conductor to PAD
115Compression type connector for Single HTLS conductor to Single HTLS Conductor-T-type
116Compression type connector for Twin HTLS conductor to 50 mm Buspipe
117Compression type connector for Twin HTLS conductor to 40mm Dia Stud/PAD
118Compression type connector for Twin HTLS conductor to 3 Inch IPS
119Compression type connector for Twin HTLS conductor to 40mm Dia Stud/PAD
120Compression type connector for Twin HTLS conductor to Twin HTLS conductor
121HARDWARE FITTINGS AND CLAMP & CONNECTOR AS SPARE AS PER TECHNICAL SPECIFICATION
122Compression type Tension Clamp (Dead End Assembly) suitable to match with the Existing Single/Double Tension Hardware Fittings Complete suitable for Twin HTLS Conductor.
123Suspension Clamp suitable to match with the existing Single/Double Suspension Hardware Fittings Complete suitable for Twin HTLS Conductor.
124Vibration Damper
125Compression type T-Connector suitable for above HTLS conductor to HTLS Conductor
126Spacer for Twin HTLS
127Compression type connector for Single HTLS conductor to 40mm Dia Isolator Stud
128Compression type connector for Single HTLS conductor to 30 mm Dia CT Stud
129Compression type connector for Single HTLS conductor to 40mm Dia CT Stud
130Compression type connector for Single HTLS conductor to 3 Inch IPS
131Compression type connector for Single HTLS conductor to Twin HTLS Conductor-T-type
132Compression type connector for Single HTLS conductor to PAD
133Compression type connector for Single HTLS conductor to Single HTLS Conductor-T-type
134Compression type connector for Twin HTLS conductor to 50 mm Buspipe
135Compression type connector for Twin HTLS conductor to 40mm Dia Stud/PAD
136Compression type connector for Twin HTLS conductor to 3 Inch IPS
137Compression type connector for Twin HTLS conductor to 40mm Dia Stud/PAD
138Compression type connector for Twin HTLS conductor to Twin HTLS conductor
139Mid Span Compression Joint
140Compression Type Repair Sleeve
141Dismantling of Existing Twin ACSR conductor with hardware fittings in 220 KV Subhasgram (PGCIL) -Subhasgram (WBSETCL) D/C Transmission Line including 220 kV, 2 (Two) Main Bus and 01 (One)Transfer Bus and handing over the same at WBSETCL Store as per direction of E-I-C.
142Erection of TWIN HTLS conductor (to be supplied by WBSETCL) with the hardwares and accessories in the above Line including 220 kV, 2 (Two) Main Bus and 01 (One)Transfer Bus as per Technical Specification.(All Road Crossings/ Building crossings are to be erected with the Double Tension /Suspension Fittings as per the direction of E-I-C)
143Solid Carbon Composite core HTLS Conductor as per Technical Specification
144Solid Carbon Composite core HTLS Conductor to carry minimum current of 1200A, for 220 kV Durgapur 220 kV - SHYAM SEL S/C Transmission Line (CKM= 34.90), as per technical specification.
145Above HTLS Conductor -as SPARE
146Hardware Fittings and Clamp & Connector for above HTLS Conductor, as per Technical Specification
147Compression type Tension Clamp (Dead End Assembly) suitable to match with the existing Single/ Double Tension Hardware Fittings Complete.
148Compression type Tension Clamp (Dead End Assembly) suitable to match with the existing Double Tension Hardware Fittings Complete.
149Suspension Clamp suitable to match with the existing Single Suspension Hardware Fittings Complete.
150Suspension Clamp suitable to match with the existing Double Suspension Hardware Fittings Complete.
151Vibration Damper
152Suspension Clamp suitable to match with the existing Pilot Insulator Suspension Hardware Fittings Complete.
153Compression type T-Connector suitable for above HTLS conductor to Existing ACSR Conductor
154Compression type connector for CT Stud to HTLS Conductor
155Hardware Fittings and Clamp & Connector for above HTLS Conductor, as per Technical Specification- as SPARE
156Compression type Tension Clamp (Dead End Assembly) suitable to match with the existing Single/ Double Tension Hardware Fittings Complete.
157Compression type Tension Clamp (Dead End Assembly) suitable to match with the existing Double Tension Hardware Fittings Complete.
158Suspension Clamp suitable to match with the existing Single Suspension Hardware Fittings Complete.
159Suspension Clamp suitable to match with the existing Double Suspension Hardware Fittings Complete.
160Vibration Damper
161Suspension Clamp suitable to match with the existing Pilot Insulator Suspension Hardware Fittings Complete.
162Compression type T-Connector suitable for above HTLS conductor to Existing ACSR Conductor
163Compression type connector for CT Stud to HTLS Conductor
164Mid Span Compression Joint
165Compression Type Repair Sleeve
166Dismantling of Existing ACSR conductor with hardware fittings in 220 kV Durgapur 220 kV - SHYAM SEL S/C Transmission Line and handing over the same at WBSETCL Store as per direction of E-I-C.
167Erection of supplied HTLS conductor with hardware and accessories in the above Line as per Technical Specification.(All Road Crossings/ Building crossings are to be erected with the Double Tension /Suspension Fittings as per the direction of E-I-C)
168Solid Carbon Composite core HTLS Conductor as per Technical Specification
169Solid Carbon Composite core HTLS Conductor to carry minimum current of 1200A for 220 kV, DURGAPUR 220KV - MONGALPUR 220 KV S/C Transmission Line (CKM= 31.08), as per technical specification.
170Above HTLS Conductor -as SPARE
171Hardware Fittings and Clamp & Connector for above HTLS Conductor, as per Technical Specification
172Compression type Tension Clamp (Dead End Assembly) suitable to match with the existing Single Tension Hardware Fittings Complete.
173Compression type Tension Clamp (Dead End Assembly) suitable to match with the existing Double Tension Hardware Fittings Complete.
174Suspension Clamp suitable to match with the existing Single Suspension Hardware Fittings Complete.
175Suspension Clamp suitable to match with the existing Double Suspension Hardware Fittings Complete.
176Vibration Damper
177Suspension Clamp suitable to match with the existing Pilot Insulator Suspension Hardware Fittings Complete.
178Compression type T-Connector suitable for above HTLS conductor to Existing ACSR Conductor
179Compression type connector for CT Stud to HTLS Conductor
180Hardware Fittings and Clamp & Connector for above HTLS Conductor, as per Technical Specification- as SPARE
181Compression type Tension Clamp (Dead End Assembly) suitable to match with the existing Single Tension Hardware Fittings Complete.
182Compression type Tension Clamp (Dead End Assembly) suitable to match with the existing Double Tension Hardware Fittings Complete.
183Suspension Clamp suitable to match with the existing Single Suspension Hardware Fittings Complete.
184Suspension Clamp suitable to match with the existing Double Suspension Hardware Fittings Complete.
185Vibration Damper
186Suspension Clamp suitable to match with the existing Pilot Insulator Suspension Hardware Fittings Complete.
187Compression type T-Connector suitable for above HTLS conductor to Existing ACSR Conductor
188Compression type connector for CT Stud to HTLS Conductor
189Mid Span Compression Joint
190Compression Type Repair Sleeve
191Dismantling of Existing ACSR conductor with hardware fittings in 220 kV Durgapur 220 kV - Mongalpur 220 kV S/C Transmission Line and handing over the same at WBSETCL Store as per direction of E-I-C.
192Erection of supplied HTLS conductor with hardware and accessories in the above Line as per Technical Specification.(All Road Crossings/ Building crossings are to be erected with the Double Tension /Suspension Fittings as per the direction of E-I-C) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57406841
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 05-10-2026
Authority
Authority Name West Bengal State Electricity Trasnmission Company Limited
Work Description Tender for Replacement Of Existing Acsr Zebra Conductor By Htls Conductor ( To Carry Minimum Current 1200 A) I.R.O 220 Kv Transmission Lines -1. Jeerat -Barasat D/C (Ckm= 42.00);2. Ktpp-Food Park D/C (Ckm= 104.00); 3. Jangalpur-Food Park D/C (Ckm= 12.00); 4. Subhasgram Pgcilsubhasgram Wbsetcl D/C Along With Replacement Of 220 Kv Two Main & One Transfer Bus Conductors At Subhasgram Wbsetcl Substation (Ckm=02.50); 5. Durgapur 220-Shayam Sel S/C (Ckm=34.9); 6.Durgapur 220-Mongalpur S/C (Ckm=31.08) And Allied Works On Turn-Key Basis.
Basic Detail
Tender No CE/ (O And M) - I/220 KV HTLS/JEERATBARASAT/ 26-27/10, DATED 08.09.2026
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 08 Sep 2026
Submission Date 05 Oct 2026
Open Date 07 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 1.50 Crore
Exemption Not Available
Document List
73bdca45-9176-4967-9502-d02dd013ca5c.html
Annexures.pdf
Appendix_to_Affidavit_reg_1.pdf
Bid_Forms.pdf
BOQ_2556244.xls
PRE_BID_FORMAT.xls
Tendernotice_1 (38).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Oct 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

73bdca45-9176-4967-9502-d02dd013ca5c.html

pdf

Annexures.pdf

pdf

Appendix_to_Affidavit_reg_1.pdf

pdf

Bid_Forms.pdf

xls

BOQ_2556244.xls

xls

PRE_BID_FORMAT.xls

pdf

Tendernotice_1 (38).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders