Water Resources and Irrigation Local Bodies Closing in 5 days TDR #57405981

Tender For State Plan-State Plan-( 2026-27 )- Rwss To Elanthoor - Mallapuzhassery -Supply , Erection And Commissioning Of Suitable Hp Vt Pump Sets At Elanthoor-Mallapuzhassery Intake (Near Aranmula Temple) -State Plan-Pipeline Work

Issued by Local Bodies · Pathanamthitta, Kerala
Tender Value
34.59 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
5 days left
EMD
50000
Bank guarantee accepted
Document Fee
2760
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pathanamthitta → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for State Plan-State Plan-( 2026-27 )- Rwss To Elanthoor - Mallapuzhassery -Supply , Erection And Commissioning Of Suitable Hp Vt Pump Sets At Elanthoor-Mallapuzhassery Intake (Near Aranmula Temple) -State Plan-Pipeline Work

BOQ

Name of Work:- State Plan-State Plan-( 2026-27 )- RWSS to Elanthoor - Mallapuzhassery -Supply , Erection and Commissioning of suitable HP VT Pump Sets at Elanthoor-Mallapuzhassery Intake (Near Aranmula Temple) -State plan-Pipeline Work
Sl. No. Item Description
1Supplying erecting and commissioning of suitable VT pump set with all accessories at Elanthoor-Mallapuzhassery Intake Pump House
2OD264209/2025-2026:Design, supply and erection of reputed make best quality electrically driven water lubricated VT pump set , working one at a time having an individual discharge of 4500 M3/ day against a total head of 120 M (as per BEE standards) with the following specifications. 1) Pump - Supply ,erection testing and commissioning of KWA prequalified reputed make Vertical Turbine pump sets of Discharge per pump -4500 M3/ day , Total head - 120 M, Impeller - Bronze, Approximate length of column assembly - 15 M with flanged type column pipe (not more than 1.50 M length) with stainless steel line shaft, with couplings bronze impeller, bowl assembly with strainer etc. 2) Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make 1470 rpm SPDP emery efficient 3 phase AC, working voltage 418 V, 50 HZ TEFC vertically mounted squirrel cage induction motor with all accessories such as non reversible ratchet assembly etc. confirming to relevant IS as suitable in all respect to start and run coupled with the pump on all laid conditions (the motor should be if approved manufacturers by KWA) including providing suitable concrete foundation including cost of cement , sand and metal etc. complete. 3) Starter - Supply ,erection testing and commissioning of suitable rating Fully automatic Auto Transformer Starter with air break contact or FMCA soft starter suitable for the above motor with over voltage and under voltage protection, single phase run preventor, dry run preventor, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete. 4) Panel Board ( Suitable for operating two pump sets but one pump set at a time) . Supply ,erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1No. Suitable capacity MCCB as incomer and 2Nos. Suitable capacity MCCB as out going ( the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar interconnect the above MCCBs and fitted with 3Nos. of indicator lamps, 1No. volt meter with selector switch, 1No. Ammeter with selector switch and CTs etc. complete and provided with a common earth bus for the entire panel and interconnect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. 5) Cabling Works - Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from meter board to panel board, panel board to starter and from starter to motor considering energy conservation. 6) Earthing - Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/Copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. 7) Capacitor - Supply ,erection testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. the capacitor shall confirm to IS 2834. 8) Valves - Supply of 150/ 200mm or above size best quality heavy duty PN1.6 and ISI marked CI double flanged sluice valve and non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for non return valves. In case of positive suction, pump set sluice valve should be in suction as well as delivery sides for easy repair works. 9) Suction and delivery pipe connection - Supply and fitting of 150/200mm or above size best quality MS pipe of thickness not less than 10mm of required length suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. Supply and fixing best quality 100mm dia pressure gauge glycerine filled with SS body calibrated and graduated in kg/cm2 (0 to 10) with control valve and copper tube of required and all other accessories. 10)Supply and erection of suitable size MS fabricated wall mounting type meter board enabling to take power connection from KSEB with all accessories such as suitable size three phase fuse units - 3nos, single phase main switch - 1no, neutral link - 1no, single phase fuse unit - 1no, ELCB -1no. etc, making necessary cable holes, providing necessary enclosures for locking KSEB meters etc. complete as per KSEB rules and regulations. 11) Preparing all documents and submitting to KSEB through licensed electricians for obtaining power allocation for pump house from KSEB in order to run the pumpsets including all expenses for preparing documents and submitting but excluding power allocation charges payable to KSEB. 12) Erection charges of motor and pump with including all the above items on suitable cement concrete /MS foundations with MS plate, providing copper strips etc as per relevant IS standard and IE rules and conducting trial run without interruption to existing pumping arrangement.13) Additional supply and fitting of 150mm sluice valve on mallapuzhasseri distribution line Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57405981
AUTHORITY Local Bodies
TENDER VALUE 34.59 Lakhs
LAST DATE 15-09-2026
Authority
Authority Name Kerala Water Authority
Work Description Tender for State Plan-State Plan-( 2026-27 )- Rwss To Elanthoor - Mallapuzhassery -Supply , Erection And Commissioning Of Suitable Hp Vt Pump Sets At Elanthoor-Mallapuzhassery Intake (Near Aranmula Temple) -State Plan-Pipeline Work
Basic Detail
Tender No 11/26-27/EE/PH/PTA
Bidding Type Tender
Location
City Pathanamthitta
State Kerala
Key Dates
Publish Date 08 Sep 2026
Submission Date 15 Sep 2026
Open Date 16 Sep 2026
Finance
Tender Value 34.59 Lakhs
Tender Fee 2760
EMD 50000
Exemption Not Available
Document List
BOQ_1470241.xls
c0b38102-a45f-4616-885b-babddea2a6fe.html
KWAGeneralConditionsforeT_1.pdf
pricesbd.pdf
Tendernotice_1 (19).pdf
Tendernotice_2.pdf
Tendernotice_3 (1).pdf
Tendernotice_4.pdf
Tendernotice_5.pdf
Tendernotice_6.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Sep 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1470241.xls

html

c0b38102-a45f-4616-885b-babddea2a6fe.html

pdf

KWAGeneralConditionsforeT_1.pdf

pdf

pricesbd.pdf

pdf

Tendernotice_1 (19).pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3 (1).pdf

pdf

Tendernotice_4.pdf

pdf

Tendernotice_5.pdf

pdf

Tendernotice_6.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders