Water Resources and Irrigation Government Departments Closing in 6 days TDR #57405565

Tender For Supply, Replacement, Augmentation Of Ht (33/3.3Kv) And Lt Transformer, Ht Vcb Panel And Other Allied Accessories At Various Pump Houses In M/Garh W/S Mech. Division Narnaul

Issued by Government Departments · Mahendragarh, Haryana
Tender Value
14.50 Crore
Estimated cost
Bid Submission
17 Sep 2026
6 days left
EMD
29 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mahendragarh → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Supply, Replacement, Augmentation Of Ht (33/3.3Kv) And Lt Transformer, Ht Vcb Panel And Other Allied Accessories At Various Pump Houses In M/Garh W/S Mech. Division Narnaul

BOQ

Name of Work:-
Sl. No. Item Description
1Supply erection & Comissioning power transformer 3.5 MVA 33/3.3 KV with augmentation of 5 MVA power transformer installed at 33 KV sub station of various Pump Houses under ‘OP’ S/Divn. DHBVN, Nahar, Kanina,Buchawas, M/Garh & Simha . Transformer complete with all accessories with 5 year complete warranty {Including ACSR conductor 50 sqmm (Rabbit) , GSL 8SWG G.I Nut and bolt of sizes, eye screw bolt wt. 0.483 kg,} /fitting & conforming to Nigam's technical specification No. CSC-76-R-I/DH/UH/P&D/2015-16 and relevant ISS with latest amendments including all charges i.e Supply, transportation charges/crane charges loading & unloading charges, Fencing & Stone gravels in switch yards area, 4 No. Fire Extingusher with each Transformer, 8x8 feet plinth structure and any type of testing charges i.e. M&P , CEI charges etc. (all type of third party inspection charges during any state inclusive of rate) including Chemical earthing (earthing rod wt. 6.175kg GI pipe 40mm dia 6 mtr. Long earthing set B class, GI strip 25x6mm 9mtr. for earthing wt. 10.80kg, Copper plate earthing for Neutral of transformer, Energy meter, insulator, Cable Dismantlement, Cable erection with 33 KV HT XLPE Cable Termination Kit Single core 630 sqmm (8 No. Indoor Kit & 8No. Outdoor Kit) &1000 sqmm (4 No. Indoor Kit & 4 No. Outdoor Kit) and Commissioning Charges as per site requirement. (at PH MC-1,2,3,4 NB-1,4,5)
2Replacement of 200 KVA 3.3/0.440 KV Distribution transformer with 400KVA 3.3/0.440 KV Distribution transformer {Including ACSR conductor 50 sqmm (Rabbit) , GSL 8 SWG G.I nuts and bolts of sizes, eye screw bolts wt. 0.483 kg, earthing rod wt. 6.175kg GI pipe 40mm dia 6 mtr. Long earthing set B class, GI strip 25x6mm 9mtr. for earthing wt. 10.80kg, Lightening Arrestor 9 KV, HT XLPE cable 3c*50sqmm with TR, Termitation kit O/D 3c*50 sqmm, wodden gutka GI channel 100x50x6mm 2200 mm for holding fuse board, LT fuse board with busbar abd aluminium patti, plinth structure including PCC Pole 11 Mtr. Long, 3.3KV GO switch complete with handle, pipe & supporting channel, Single Core 630 sqmm cable with proper thimbling and any other leftover item if any as per site requirement and spcification appproved by DHBVN Department.} installed at 33 KV sub station Pump House NB-5
3Replacement of 100 KVA 3.3/0.440 KV Distribution transformer with 200KVA 3.3/0.440 KV Distribution transformer {Including ACSR conductor 50 sqmm (Rabbit) , GSL 8 SWG G.I nuts and bolts of sizes, eye screw bolts wt. 0.483 kg, earthing rod wt. 6.175kg GI pipe 40mm dia 6 mtr. Long earthing set B class, GI strip 25x6mm 9mtr. for earthing wt. 10.80kg, Lightening Arrestor 9 KV, HT XLPE cable 3c*50sqmm with TR, Termitation kit O/D 3c*50 sqmm, wodden gutka GI channel 100x50x6mm 2200 mm for holding fuse board, LT fuse board with busbar abd aluminium patti, plinth structure including PCC Pole 11 Mtr. Long, 3.3KV GO switch complete with handle, pipe & supporting channel, Single Core 630 sqmm cable with proper thimbling and any other leftover item if any as per site requirement and spcification appproved by DHBVN Department.} installed at 33 KV sub station Pump House NB-1 & 4
4Supply, Installation & Commissioning of 1600 KVA Transformer 11 KV/440 V {Including ACSR conductor 50 sqmm (Rabbit) , GSL 8 SWG G.I nuts and bolts of sizes, eye screw bolts wt. 0.483 kg, earthing rod wt. 6.175kg GI pipe 40mm dia 6 mtr. Long earthing set B class, GI strip 25x6mm 9mtr. for earthing wt. 10.80kg, Lightening Arrestor 9 KV, HT XLPE cable 3c*50sqmm with TR, Termitation kit O/D 3c*50 sqmm, wodden gutka GI channel 100x50x6mm 2200 mm for holding fuse board, LT fuse board with busbar abd aluminium patti, plinth structure including PCC Pole 11 Mtr. Long (with Half clamp weight 1.47 kg HVPN Drg. No. 2380, full clamp weight 2.325 kg HVPN Drg. No. 2349, 11KV Polymeric pin with insulator , 11KV Polymeric Disc insulator with fitting (T&C type), Stay set 8 feet long complete with X - Plate 460m of angle 65x65x6mm Elbow & rod Wt.13.80kg , stay wire 7/8 SWG, GI channel 100x50x6mm 2200 mm for H- Pole wt 21.032 kg , GI channel 50x50x6mm 2400 mm for earth wire wt. 10.80kg, GI channel 75x40x6mm 2200 mm for fuse unit wt 15.708kg, GI channel 100x50x6mm 2200 mm for H- Pole wt 21.032 kg,11KV GO switch complete with handle, pipe & supporting channel, Single Core 630 sqmm cable with proper thimbling and any other leftover item if any as per site requirement and spcification appproved by DHBVN Department.} at PH NB-6
5Supply, errection & commissioning of 33/3.3 kV VCB, (Indoor type/incommer Panel) with 02 No. 3.3kV outgoing CTR 800/400-5-5A, indoor metal-clad draw out VCB incommer-1250 A & outgoing 630A each, 3.6kV Class, 25kA for 3 second, 62.5kA peak, vecume interpretor, with numerical OC/EF protection, CTs, PT/VT as required, transformer protection trip interfaces, metering, earth switch, interlocks, IAC protection suitable for 33/3.3KV, 5MVA Power Transformer at Sub Station Yard end with complete earthing, lightening Arrestor and all other protections as per DHBVN approved specifications with IEC 62271 series/applicable IS standards. (at PH MC-1,2,3,4 NB-1,4,5)
6Supply, errection & commissioning of 11 KV VCB Panels set (Set of 01 incoming and 02 outgoing Panels) 25 KA, 475 MVA rupturing capacity, 24V DC operated, indoor type with a set of CTs 400-200/ 5-5A, PTS KWH Meter, Relays, instruments, earthing etc complete in all respect conforming to Nigam's (DHBVN) Tech Set (Set specifications & all relevent ISS/IES with latest amendments. Rating:- 1250 Amps for of 01 IC both incoming & outgoing Panels (Indoor Type) alongwith LT Switchgear 1600 Amps ACB, 4 Pole, Manual Operated, Fixed types with enclosures & with copper bush bars. Make:- As per latest list of approved makes by DHBVN at PH NB-6
7Supply, laying & installatuion of 33/3.3 KV HT TR-XLPE 1000 sqmm single core armoured Aluminium Cable confirming to IS 7098/(Part-II)1995 (Cable Code A2XCEFaY) as approved make
8Supply, laying & installatuion of 3.3 KV HT TR-XLPE 630 sqmm single core armoured Aluminium Cable confirming to IS 7098/(Part-II)1995 (Cable Code A2XCEFaY) as approved make
9Supply, laying and installation HT Cable 240 Sq mm, 3.3 KV, Three Core armoured Aluminium Cable as latest ISI specification of approved make by technical committee. (Cable Code A2XCEFY)
10Supply, laying and installation of LT 1100 Volts Cable PVC XLPE armoured Aluminium Conductor of sizes as mentioned as per relevant IS specification & approved make as per annexure-c in technical specification (Cable Code A2XWaY/A2XFaY) 1. Single Core 1000 Sq. MM
11Providing and fixing of chemical Earthing by digging diameter 200 mm, complete with G.I. electrode with GI strip of suitable length with proper specification and proper wiring with all allied accessories and Coke & salt etc along with name plate complete as per requirement.
12Providing & Fixing of Lightening arrester with protection radius of 100 mtr. Alongwith earthing management as per proper specifications of Pump House Building and as per site requirement
13Supply, laying of HDPE Pipe 200mmm PE-63 PN8 for cables protection
14HSR Item 34.29.2-Providing and fixing 1.8 metres high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x50 mm x 6 mm placed every 3 metres centre to centre founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 807 HSR Rate (Rs):- 435.00 Through Rate around all pump House (350 mtr for each PH) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57405565
AUTHORITY Government Departments
TENDER VALUE 14.50 Crore
LAST DATE 17-09-2026
Authority
Authority Name Department Of Irrigation
Work Description Tender for Supply, Replacement, Augmentation Of Ht (33/3.3Kv) And Lt Transformer, Ht Vcb Panel And Other Allied Accessories At Various Pump Houses In M/Garh W/S Mech. Division Narnaul
Basic Detail
Tender No 4259-72/9-A Dated 27/08/2026
Bidding Type Tender
Location
City Mahendragarh
State Haryana
Key Dates
Publish Date 08 Sep 2026
Submission Date 17 Sep 2026
Open Date 18 Sep 2026
Finance
Tender Value 14.50 Crore
Tender Fee 20000
EMD 29 Lakhs
Exemption Available
Document List
4d244d6c-0c17-430a-a376-d62088121e62.html
AnnexureC.pdf
Approvedmake.pdf
Bidbook11.pdf
BOQ_625808.xls
Tendernotice_1 (19).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Sep 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

4d244d6c-0c17-430a-a376-d62088121e62.html

pdf

AnnexureC.pdf

pdf

Approvedmake.pdf

pdf

Bidbook11.pdf

xls

BOQ_625808.xls

pdf

Tendernotice_1 (19).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders