Tender For Repair And Replacement Of Old Unserviceable Cleaning Of Tank, Painting Of Overhead Tank And Old Unserviceable Ci/Gi Pipe Line At Rangia Under Ge Rangia
Tender Value
48 Lakhs
Estimated cost
Bid Submission
29 Sep 2026
16 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baksa → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Replacement Of Old Unserviceable Cleaning Of Tank, Painting Of Overhead Tank And Old Unserviceable Ci/Gi Pipe Line At Rangia Under Ge Rangia
BOQ
| Sl. No. | Item Description |
| 1 | M& L for Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed. |
| 2 | M&L for Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm, including dipositing the surplus soil along the line of pipe/ cable in the form of heap, complete all as per specified and as directed. |
| 3 | M&L for laying 32 mm dia (Outer) 3- layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply with all PP-R plain & brass threaded fittings fixed to wall including taking down the existing old unserviceable CI/GI/MS/PP-R pipe and testing complete all as specified and as directed. |
| 4 | All as per Item No. 03 here-in-above, but for 25mm dia (Outer) pipe complete all as specified and as directed. |
| 5 | M&L for laying 110 mm dia (Outer) 3- layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply with all PP-R plain & brass threaded fittings laid in trenches including taking down the existing old unserviceable CI/GI/MS/PP-R pipe and testing, complete all as specified and as directed. |
| 6 | All as per Item No. 05 here-in-above, but for 90mm dia (Outer) pipe, complete all as specified and as directed. |
| 7 | All as per Item No. 05 here-in-above, but for 63mm dia (Outer) pipe, complete all as specified and as directed. |
| 8 | All as per Item No. 05 here-in-above, but for 50mm dia (Outer) pipe, complete all as specified and as directed. |
| 9 | All as per Item No. 05 here-in-above, but for 32mm dia (Outer) pipe, complete all as specified and as directed. |
| 10 | All as per Item No. 05 here-in-above, but for 25mm dia (Outer) pipe, complete all as specified and as directed. |
| 11 | Supply & Fixing, jointing and testing of cast iron sluice Valve ISI mark of size 150 mm bore (Internal Dia) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets including taking out old unserviceable sluice valves complete all as specified and as directed. |
| 12 | All as per Item No. 11 here-in-above, but for 100 mm bore (Internal Dia) CI Sluice valve having gun metal spindle, complete all as specified and as directed. |
| 13 | All as per Item No. 11 here-in-above, but for 80mm bore (Internal Dia) CI Sluice valve having gun metal spindle, complete all as specified and as directed. |
| 14 | S&F in repair of 63 mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed. |
| 15 | All as per Item No. 14 here-in-above, but for 50mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed. |
| 16 | All as per Item No. 14 here-in-above, but for 32mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed. |
| 17 | All as per Item No. 14 here-in-above, but for 25mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed. |
| 18 | Supply & Fixing, jointing and testing of cast iron Non Return Valve (NRV) ISI mark of size 100 mm bore, without bypass arrangement, swing type, conforming to IS-5312, complete with nuts, bolts, washers and gaskets including taking out old unserviceable NRV, complete all as specified and as directed. |
| 19 | Supply and Fix CI butterfly valve 150 mm dia without lugs, lever operated CI disc, EPDM rubber lining including taking out old unserviceable one, complete all as specified and as directed. |
| 20 | Supply and Fix CI butterfly valve 100 mm dia without lugs, lever operated CI disc, EPDM rubber lining including taking out old unserviceable one, complete all as specified and as directed. |
| 21 | M&L for construction of Brick Masonry Valve Pit, of size 1200mm X 1200mm X 1200mm (Internal dimension), one Brick thick wall in cement mortar 1:4 on 150mm thick PCC 1:4:8, type D-2 (40mm graded aggregate) in Foundation, Rendering 15mm thick internally upto full depth and externally upto 150mm below GL, providing 4 mm thick MS sheet valve Pit Cover, welded with 40X6mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 50 x 50 x 6mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230 x 200 x 100 mm, applying two coats of Synthetic enamel Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed to Steel Surfaces including necessary Earth Work in Soft/Loose Soil and demolition of old unserviceable Valve Pit, complete all as specified and directed. |
| 22 | All as per Item No. 21 here-in-above, but for Brick Masonry Valve Pit, of size 900mm X 900mm X 900mm (Internal dimension), complete all as specified and as directed. |
| 23 | S&F in replacement of chemical dosing pump based on micro processor control of capacity of 100 ltrs per hours @ 10 kg Back pressure, 240 V, 50Hz and also replacement of FRP solution preparation cum settling tank with sludge deposition facility fitted with PVC agitator of capacity 100 ltrs with lid, port hole, inlet,oulet/drain connection, level gauge and fitted with 900 RPM motor for proper mixing of chemical solution facility including suitable size of connection pipe as per manufacturers recommendation for inlet-outlet pipe etc. and necessary connection to the terminal complete all as specified and as directed. |
| 24 | M&L for applying two coats of synthetic enamel paint (1st quality) by spray painting of existing colour on pump, motor, channel frame, inlet-outlet GI/ MS pipe line of pump house after necessary cleaning and preparation of surfaces, complete all as specified and as directed. |
| 25 | S&F in repair of combined digital voltmeter and ammeter as per existing size suitable for motor starter/ APFC Panel, complete all as specified and as directed. |
| 26 | S&F in-repair of pressure gauge 3'' dial 0-2.5 kg/cm² rating complete with nuts, bolts, washers and gaskets, complete all as specified and as directed. |
| 27 | S&F in repair fully automatic star delta starter 30 HP in sheet metal encloser type MN with single phase protection feature, AC 3 Phase 415 Volt 50 Hz, complete all as specified and as directed. |
| 28 | S&F in repair fully automatic star delta submersible starter 20 HP in sheet metal encloser type MU-G with single phase protection feature, AC 3 Phase 415 Volt 50 Hz, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 29 | S&F in repair fully automatic star delta submersible starter 20 HP in sheet metal encloser type MU-G with single phase protection feature, AC 3 Phase 415 Volt 50 Hz, complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysOct 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender