Bids Are invited for Custom Bid For Services - Electrical Supply Works Of 32 Nos Air Conditioners At Tempo Club And Manoranjan Kendra Under Ghugus Sub Area - Making Cement Concrete Foundation Including Excavation For The Poles 60 Cm X 60 Cm X Deep 1/
Tender Overview
Project Description
Bids Are invited for Custom Bid For Services - Electrical Supply Works Of 32 Nos Air Conditioners At Tempo Club And Manoranjan Kendra Under Ghugus Sub Area - Making Cement Concrete Foundation Including Excavation For The Poles 60 Cm X 60 Cm X Deep 1/6 Of Pole Length In 1:3:6 Cement Concrete (20 X 25 Mm Stone Metal) And 45 Cm X 45 Cm X 45 Cm /45 Cm Dia. X 45 Cm. Height Plinth Duly Plastered And With Necessary Curing And Finishing In An Approved Manner. (For 9 M Poles & Above) 16-3-4 (23-24) , Making Cement Concrete Foundation Including Excavation For (60 X 60 X 150)Cm Deep In 1:3:6 Cement Concrete, (20 To 25) Mm Stone Metal With Necessary Curing And Finishing Complete .(For Stay ) 16-3-6 (23-24) , Supplying And Erecting Guarding Loop Using G.L. Wire No. 8Swg For Lt Oh Line Of Horizontal Formation Erected With 20Swg G.L. Wire As Binding Wire And 50Mm Section On Each Side Complete. 8-6-6 (23-24) , Supplying And Erecting Rolled Steel Joist (Girder) Pole 200 X 100 Mm. (25.9 Kg/M) With Provided Base Plate In Provided Foundation As Per Specification No. Oh-Pl/Rsj 8-1-10 (19-20) , Supplying And Erecting Bracket For Guarding Of Ht Oh Line, Made From Channel Iron 1600Mm In Length And 65X65x6mm Thick Erected On Pole As Per Specification No. Oh-Pl/Vc 8-3-16 (23-24) , Supplying And Erecting Acsr Conductor Of Size - 6/1-4.72 Mm (Dog) Complete. (394.00 Kg/Km) As Per Specification No.Oh-Con/Acsr 8-5-11 (19-20) , Supplying And Erecting Hard Drawn G.I. Wire 8 Swg Complete Erected For Overhead Line With Proper Size Of G.I. Wire For Binding With Jumpering Etc. 8-5-12 (17-18) , Supplying & Erecting Gi Stay Set For Poles Including Loop Insulator At Inaccesible Height Complete With Anchor Plate 300 X 300 X 6Mm Straining Screws, Gi Stay Wire 7/10Swg In Provided Cement Concrete Foundation 8-6-1 (23-24) , Supplying And Erecting Porcelain Shackle Type Lt Medium Insulator 75X115mm Dia. With G.L. (Shackle) Strips, Nuts And Bolts, Complete 8-5-2 (23-24) , Supplying & Erecting Triple Pole And Neutral Distribution Board (Tpndb), 3 Pole Mccb As Incomer & Outgoing Sp Mcb (12 Poles) Or Tp Mcb Of 4 Ways (12 Poles), With Door, 1.2Mm Thickness, Surface/Flush Mounted, On Provided Iron/Gi Frame (Vertical Busbar Type) As Per Specification No. Sw-Swr/Mcbdb1 5-4-17 (23-24)Sw- , Providing & Erecting 3 Pole Mccb, 415V, Up To 100A, Rated Short-Circuit Breaking Capacity 25 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb With Phase Barriers On Both Sides, Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. 5-5-1 (23-24) , Supplying,Erecting & Marking Spmcb 6A To 32A, C-Series With Rated Short-Circuit Breaking Capacity(Icn) 10Ka In Provided Distribution Board As Per Specificationno. Sw-Mcb 5-3-2(23-24) , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable, 1100 V 4 Core 70 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al 7-1-33 (23-24)
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Making cement concrete foundation including excavation for the poles 60 cm x 60 cm x deep 1/6 of pole length in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered and with necessary curing and finishing in an approved manner. (for 9 M Poles & Above) 16-3-4 (23-24) | Making cement concrete foundation including excavation for the poles 60 cm x 60 cm x deep 1/6 of pole length in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered and with necessary curing and finishing in an approved manner. (for 9 M Poles & Above) 16-3-4 (23-24) |
| 2 | Making cement concrete foundation including excavation for (60 x 60 x 150)cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete .(for stay ) 16-3-6 (23-24) | Making cement concrete foundation including excavation for (60 x 60 x 150)cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete .(for stay ) 16-3-6 (23-24) |
| 3 | Supplying and erecting guarding loop using G.l. wire no. 8SWG for LT OH line of horizontal formation erected with 20SWG G.l. wire as binding wire and 50mm section on each side complete. 8-6-6 (23-24) | Supplying and erecting guarding loop using G.l. wire no. 8SWG for LT OH line of horizontal formation erected with 20SWG G.l. wire as binding wire and 50mm section on each side complete. 8-6-6 (23-24) |
| 4 | Supplying and erecting Rolled steel Joist (Girder) pole 200 x 100 mm. (25.9 kg/m) with provided base plate in provided foundation as per specification No. OH-PL/RSJ 8-1-10 (19-20) | Supplying and erecting Rolled steel Joist (Girder) pole 200 x 100 mm. (25.9 kg/m) with provided base plate in provided foundation as per specification No. OH-PL/RSJ 8-1-10 (19-20) |
| 5 | Supplying and erecting bracket for guarding of HT OH Line, made from channel iron 1600mm in length and 65x65x6mm thick erected on pole as per specification no. OH-PL/VC 8-3-16 (23-24) | Supplying and erecting bracket for guarding of HT OH Line, made from channel iron 1600mm in length and 65x65x6mm thick erected on pole as per specification no. OH-PL/VC 8-3-16 (23-24) |
| 6 | Supplying and erecting ACSR conductor of size - 6/1-4.72 mm (Dog) complete. (394.00 kg/km) as per specification No.OH-CON/ACSR 8-5-11 (19-20) | Supplying and erecting ACSR conductor of size - 6/1-4.72 mm (Dog) complete. (394.00 kg/km) as per specification No.OH-CON/ACSR 8-5-11 (19-20) |
| 7 | Supplying and erecting hard drawn G.I. wire 8 SWG complete erected for overhead line with proper size of G.I. wire for binding with jumpering etc. 8-5-12 (17-18) | Supplying and erecting hard drawn G.I. wire 8 SWG complete erected for overhead line with proper size of G.I. wire for binding with jumpering etc. 8-5-12 (17-18) |
| 8 | Supplying & erecting GI Stay Set for poles including loop insulator at inaccesible height complete with anchor plate 300 x 300 x 6mm straining screws, GI Stay wire 7/10SWG in provided cement concrete foundation 8-6-1 (23-24) | Supplying & erecting GI Stay Set for poles including loop insulator at inaccesible height complete with anchor plate 300 x 300 x 6mm straining screws, GI Stay wire 7/10SWG in provided cement concrete foundation 8-6-1 (23-24) |
| 9 | Supplying and erecting porcelain shackle type LT medium insulator 75x115mm dia. with G.l. (shackle) strips, nuts and bolts, complete 8-5-2 (23-24) | Supplying and erecting porcelain shackle type LT medium insulator 75x115mm dia. with G.l. (shackle) strips, nuts and bolts, complete 8-5-2 (23-24) |
| 10 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on provided iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 5-4-17 (23-24)SW- | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on provided iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 5-4-17 (23-24)SW- |
| 11 | Providing & erecting 3 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. 5-5-1 (23-24) | Providing & erecting 3 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. 5-5-1 (23-24) |
| 12 | Supplying,erecting & marking SPMCB 6A to 32A, C-series with rated short-circuit breaking capacity(Icn) 10kA in provided distribution board as per specificationno. SW-MCB 5-3-2(23-24) | Supplying,erecting & marking SPMCB 6A to 32A, C-series with rated short-circuit breaking capacity(Icn) 10kA in provided distribution board as per specificationno. SW-MCB 5-3-2(23-24) |
| 13 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 7-1-33 (23-24) | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 7-1-33 (23-24) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender