Tender For Revival, Restoration,Preservation And Maintenance Of Architecture And Heritage Of Shrine Of Baba Haneef-Ud-Din (Ra) Yarmuqam Ganderbal.
Tender Value
75 Lakhs
Estimated cost
Bid Submission
14 Sep 2026
4 days left
EMD
1.50 Lakhs
Bank guarantee accepted
Document Fee
1600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ganderbal → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Revival, Restoration,Preservation And Maintenance Of Architecture And Heritage Of Shrine Of Baba Haneef-Ud-Din (Ra) Yarmuqam Ganderbal.
BOQ
| Sl. No. | Item Description |
| 1 | Clearance of site b.w.o removing garbage humps extracting of bushes by Mechanical/manual means incl. removal of same from site to out side municipal limits with roots making site workable for laying of layout for proposed building. |
| 2 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : |
| 3 | P/L, of dry stone soling duly hand packed with ramming, dressing, and compacting all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved complete |
| 4 | Supply & laying of GSB under floors in rooms sides of foundations etc consolidating each layer by ramming ,watering, compacting, all inclusive leads, lifts, loading, un-loading, cost and carriage of material all complete. |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) complete. |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m all complete. |
| 7 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) complete. |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.including all carriage involved complete. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form work for: Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs andsteps etc. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers etc all complete. |
| 12 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) complete. |
| 13 | Providing hoisting and fixing trusses/purlins /rafters/posts/ post-plates or like components including cost of screws etc. complete (Imported wood) Complete. |
| 14 | Labour charges for dismantelling of wood work and re-fixing the same as per the directions of EIC |
| 15 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : Of area beyond 3 sqm complete. |
| 16 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of : G.S. Sheet all complete. |
| 17 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead : Of sectional area 40 sqcm. and above all complete. |
| 18 | Removing white or color wash /distemper/paint by scrapping and sand papering and preparing the surface smooth including necessary repairs toscratches etc. complete. |
| 19 | Removing Polish by scrapping and sand papering and preparing the surface smooth including necessary repairs toscratches etc. complete. |
| 20 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand) incl. scaffolding all complete. |
| 21 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. complete. |
| 22 | Providing and laying chisel dressed Devri Stone of size 300x200 mm face with 150 mm depth in cement mortar 1: 6 (1 cement : 6 coarse sand) upto plinth level including curing. One face dressed Fine chisel dressed all complete. |
| 23 | Melamine polishing on wood work (one or more coats) |
| 24 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class kail wood all complete. |
| 25 | Providing and fixing of 35-40mm thick wooden Ornamental/hand kashmirir carved (Fully carving on front side and 50% carving on back side) door shutters of 1st class kail wood as per approved pattern and design all complete as per directions of EIC complete. |
| 26 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work |
| 27 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 28 | Providing and fixing of 4mm thick panels of colour glass for fixed glazing panels/shutters (only panel area to be measured) incl. cost of teak wood beadings of required size incl. necessary screws, nails all complete |
| 29 | Providing and fixing of ornamental wooden post of 200mm x200mm as per the local heritage/architectural features and as per the directions of consultant incl. cost of all material all leads, lifts and carriages upto site of work complete st class Kail wood as per the directions of the consultant/s per drawings enclosed all complete. |
| 30 | Providing and fixing of ornamental wooden grill (Pinjra work) with necessary grooves and chamfer fixed with screws etc incl. all carriages etc complete. |
| 31 | Providing and fixing of 4mm thick panels of plain glass for fixed glazing panels/shutters (only panel area to be measured) incl. all necessary screws, nails cost of beadings of required size complete. |
| 32 | Providing and fixing of ornamenta wooden Planks (40mm thick) for exterior work with necessary grooves and chamfer fixed with screws incl. all carriages complete Kail wood. |
| 33 | Providing and fixing ornamental pendents of 250mm x 250mm x 450 mm each sides as corners of roof as per the local heritage/architectural features and as per the directions of consultant including cost of all material,leads lifts and carriages upto site of work complete) ist class dewdar wood as per the directions of the consultant/as per drawing enclosed |
| 34 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood excluding the cost of frame work which is to be paid separatel Changez Khani |
| 35 | Providing and fixing plain lining with necessary screws/nuts & bolts/ nails,including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineerin-charge (Frame work shall be paid for separately). 12mm thick commercial ply conforming to S : 1328 BWR type |
| 36 | Providing and fixing ornamental eves boarding (300mm x 40mm ) first class kal wood fixed with screws etc, including allcarraiges .All job completed |
| 37 | Providing and fixing 20mm thick wooden planks ceiling (frame work for base to be paid for separately) with M.S. screws 1st class deodar wood. |
| 38 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 39 | Providing and fixing of high Rib colour coated sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, complete (upto any pitch in horizontal/vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm thick incl. Ridges, hips, Valleys etc all complete. |
| 40 | P/F 12mm thick Nordic pine wall panelling (T&G) fully finished & four sides planned, fungusand termite proof ( seasoned moisture content 8% to 15% imported type ISO :14001 approved including fixing with headless nails and inclusive of all headloads and carriages , all taxes of allied material involved complete ( including B/wood frame work by 50x62mm battens not more than 600mm C/C both ways, 12 mm thick plywood) |
| 41 | Carriage of material:- Stone agg. For an avg. lead of 20 Kms |
| 42 | Sand for an avg. lead of 20 Kms |
| 43 | Electric Part |
| 44 | Wiring for Light point/Exhaust/Fan Point point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab Green/Finolex/Salzer/Havells lifeguard Make) in existing surface/recessed Conduits laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Anti-Bacterial Series of Legrand/L&T/Siemens/ABB Make & shall be approved before execution of work. |
| 45 | Supplying and Fixing of Indicator as required, ISO/IEC Certified Anti-Bacterial Series of Legrand/L&T/Siemens/ABB Make & shall be approved before execution of work. |
| 46 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified Anti-Bacterial Series of Legrand/L&T/Siemens/ABB Make & shall be approved before execution of work. |
| 47 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab Green/Finolex/Salzer/Havells lifeguard Make) Including termination and p/f of Copper thimbles of required size and number on input and out side rolled with colour coded type and p/f of ferriols on i/p and o/p side |
| 48 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Anti-Bacterial Series of Legrand/L&T/Siemens/ABB Make & shall be approved before execution of work. |
| 49 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in existing surface/Recessed Conduit (Polycab Green/Finolex/Salzer/Havells lifeguard Make) Including termination and p/f of Copper thimbles of required size and number on input and out side rolled with colour coded type and p/f of ferriols on i/p and o/p side |
| 50 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Anti-Bacterial Series of Legrand/L&T/Siemens/ABB Make & shall be approved before execution of work. |
| 51 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H/HFFR PVC insulated copper conductor, single core Cable in existing surface/Recessed medium class PVC conduit (Polycab Green/Finolex/Salzer/Havells lifeguard Make) & shall be approved before execution of work. Including termination and p/f of Copper thimbles of required size and number on input and out side rolled with colour coded type and p/f of ferriols on i/p and o/p side |
| 52 | 2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/Inverter/AC Point Sub main in One run from Main Panel to Distribution Boards. |
| 53 | 2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Lighting/Inverter Circuit in One run from switch boards to Distribution Boards. |
| 54 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Legrand/L&T/Siemens/ABB Make |
| 55 | Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/ABB /Schneider/BCH Make) |
| 56 | Supply/Fixing/Testing and Commissioning of Supplying and fixing following rating, double pole,(single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (L&T/Siemens /Legrand/ABB/Schneider/BCH Make) |
| 57 | 25-32Amp. |
| 58 | 40Amp. |
| 59 | 63Amp. |
| 60 | Providing and fixing of bakelite hylam sheets of required size including cutting, filing with S/F screws etc. |
| 61 | Supplying and Fixing of MCB 12-Way horizontal typed , sheet steel, Double Door Distribution Board, SPN 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider/BCH Make) |
| 62 | Supply ,Laying of following PVC Conduits with allied accessories ,including cutting of walls /floors with hydraulic cutters and refacing to original position by way of p/l of cement concrete /POP and painting wherever required and as per instructions of EIC (BCH/Polycab/Finolex/Astral Make. |
| 63 | 25 mm dia |
| 64 | 32 mm dia |
| 65 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required, ISO/IEC Certified Anti-Bacterial Series of Legrand/L&T/Siemens/ABB Make |
| 66 | 5/6 A switch |
| 67 | 15/16 A switch |
| 68 | 3 pin 5/6 A socket outlet |
| 69 | 6 pin 15/16 A socket outlet |
| 70 | Supply and fixing of 12 Watt LED Powder coated die cast/Extruded aluminum Body including trim with Aluminum Reflector(System lumen efficacy ≥ 120 lm/Watt ) Recess/surface mounted (Commercial type) downlighter having following specficafications .The luminaire should have a colour temperature of 6500°K, CRI≥80 and SDCM≤5. Luminaire shall be designed to emit initial system lumen output of greater than 2150 lumens .The downlighter shall be back-lit & not side-lit. The driver shall have THD≤10% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing /body should made of pressure die-cast aluminum. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP20. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, \\"FAT\\" before dispatch as per IS 10322 & IK Test. The luminary shall have average life of 50000 hrs operating temperature -10 C to + 45 C The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab & BIS certificate for LED Luminaire & Driver. The Agency / firm must submit the Technical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials. The Job includes 2-years replacement warrenty from OEM for the entire lighting fixtures from the the date of sucessful handing over of site to intending department , covering any damage /mulfunctioning /burnt out what so ever reason.Approved Make: Philips /Wipro /Regent /Endo /Surya/Halonix Make. |
| 71 | Supplying, installation, Testing & Commissioning of 50 Watt (System lumen efficacy ≥120 lm/Watt) Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 lm/Wattoutput . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). The Agency / firm must submit the Technical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials. The Job includes 2-years replacement warrenty from OEM for the entire lighting fixtures from the the date of sucessful handing over of site to intending department , covering any damage /mulfunctioning /burnt out what so ever reason.Approved Make: Philips /Wipro /Regent /Endo /Surya/Halonix Make. |
| 72 | Supply/Installation/Testing and Commissioning of BLDC 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Halonix/Havells/Orient Make.(5-Star) |
| 73 | Supply/installation/testing and commissioning of CPRI-approved panel Wall/floor-mounted compartmentalized, 230 volts DP MCCB Main Distribution panels, fabricated out of sheet steel of 16 gauge dust-protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel.The Panel is to be provided and fitted with the following adjustable-type controlling/protection switchgear devices:1. Normal Incoming:125 Amp DP MCCB with suitable breaking capacity with extended thimbles of Legrand/Siemens/ABB//LK make = 1 No.,100 Amp Bus bar Al Strips(P+N) = 1 Set,Digital Voltmeter =1 No., Digital Ammeter = 1 No., CT coils for Ammeter 300 / 5A = 1 set, phase indicator =1 No.2. Generator/Inverter Incomer:63 Amp Single Phase Automatic Change over Switch of Legrand/Siemens/ABB/Havells/LK make = 1 No.Outgoing:(1) 63 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 02 No for normal heating sub main(2) 40 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 02 No for Sub main lighting(3) 32 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 02 No for Sub main invertorThe Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to be approved by Engineer Incharge before manufacturing. |
| 74 | Supply/Installation/Testing and Commissioning of IP-65/68 Homogenous LED Strip (Warm Type) Warm light with following Specifications: Input Wattage: 08-10W / Mtr,Input Voltage: 220 - 240VAC,Input Frequency: 50 Hz, Input Current (Max): 50mA, Power Factor:. > 0.95,Surge Protection:2.5KV, High Voltage Protection:300V,HI-POT:1.5KV,IP Rating:IP 65/68,Working Temperature:-10°C to 50°C, LED:Bridgelux,Lumen Maintenance:70% After 50000 BH,Rated CCT: 3000K, 4000K, 6500K,Rated CRI:> 80,System Efficacy:100lm/W,Housing:Silicon Pipe covers the LED Strip Light of Philips/Wioro/Jaguar/Surya/Equivalent Make & Shall be approved not less than by SDO. |
| 75 | Supply/Fixing/Testing and Commissioning of of Adoptor (CV DRIVER LED STRINGS 12 V 2 A IP44-66) of Philips/Wioro/Jaguar/Surya/Equivalent Make & Shall be approved not less than by SDO. |
| 76 | Supply/Laying/Testing and Commissioning of 2-Core 25 mm sq. Al armored XLPE Insulated,PVC cable Havells/Polycab/RR Kabel/Paramount/KEI Make. Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground & above level) including excavation where required and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping.(Only required quantity shall be executed) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender