Tender For Removing Dark Spot And annual maintenance contract For 3 Years At I.A. Rania Site-1 &2 Kanpur Dehat
Tender Value
58.28 Lakhs
Estimated cost
Bid Submission
28 Sep 2026
13 days left
EMD
1.38 Lakhs
Bank guarantee accepted
Document Fee
3172
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur Nagar → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Removing Dark Spot And annual maintenance contract For 3 Years At I.A. Rania Site-1 &2 Kanpur Dehat
BOQ
| Sl. No. | Item Description |
| 1 | S/F of MS Earthing Rod (2500*20 mm) in verticaly ground level and connecting the pole with help of 6 SWG Wire including cost of all material men and T&P |
| 2 | Supply and laying of 25 mm x3mm G.I Strip from earth electrode directly in ground as required aspect as per uppwd sch no-716 |
| 3 | Supply, installation, testing and commissioning of Chemical Earthing for panel in complete in all respect as per complete. |
| 4 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. complete in all respect. (40 Amp. TPN) |
| 5 | Supply & wiring of submain with 2 Nos. of 2.5 sqmm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cables in existing conduit complete with supply of all material labour and T&P required for proper complation of the work as directed as site by Engineer I/C as Per UPPWD sch No. 289 (Polycab /KEI/ Havells/ Grandley/Gloster Make ) |
| 6 | S/F of brass nickel Plated compression gland for PVC insulated and armoured served sheated ,underground cable including rubber ring etc. comlete in all respects.the armouring of the cable shall be properly connected with the earth as per direction of Engineer-incharge as per UPPWD sch. no. 503 (k) 35 sq. mm 3.5 core |
| 7 | S/F of palm or pin type copper tin plated cable socket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (f) 35 sq. mm |
| 8 | Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected. with bruntbrick on sides and on top complete in alll respects as per PWD Sch. No. 501(J) 25sqmm 3.5core (Polycab /KEI/ Havells/ Grandley/Gloster Make ) |
| 9 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer Incharge. as per UPPWD Sch No. 503 (c) 25sqmm 3.5 core |
| 10 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. As per UPPWD Sch. No. 504 ( e) 25 |
| 11 | Supply laying and Fixing 50 dia Gi pipe trench less Through manual Boggi including trenching 90 C.M. dccp and refilling etc. |
| 12 | Supply & laying 16 sq mm 2 core Al. conductor PVC insulated armoured, served, sheathed cable 1100 V grade at a depth of 750 mm beloow ground level over a cushion of 75 mm thick sand alround and protected with burnt bricks on sides ant top. On surface the cable run shall be fixed on MS clamps of suitable size or as directed by Engineer in-charge. The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per PWD Sch. 501(c) (Polycab /KEI/ Havells/ Grandlay/Gloster Make) |
| 13 | S/F of brass nickel Plated compression gland for PVC insulated and armoured served sheated ,underground cable including rubber ring etc. comlete in all respects.the armouring of the cable shall be properly connected with the earth as per direction of Engineer - incharge as per UPPWD sch. no. 503 (c) 16 sq. mm 2 core |
| 14 | S/F of palm or pin type copper tin plated cable socket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (d) 16 sq. mm |
| 15 | Sypply & laying of 63 mm dia DWC pipe ISI marked along with all accessories like socket, bend, couple etc. confirming to IS 14930 Part-II complete with fitting and cutting, jointing etc. direct in ground (75 cm delow ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as per required. |
| 16 | Supply and fixing of LED Street light fitting having die cast aluminium body and diffuser with driver set suitable for 120 watt confirming to IP 66 protection complete in all respects (With 5 Year Gaurantee(3+2) . Catt. AA as per UPPWD Sch. No.1424 (Bajaj /Philips/Wipro/Crompton Make) |
| 17 | Supply and fixing of 200 watt factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for confirming to IP 66 protection complete in all respects. Make as per direction of the Engineer- incharge Catt. AA as per UPPWD Sch. No.1455 (Bajaj, Crompton, Philips, Wipro Make) |
| 18 | Supply & fixing of 16 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 360 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect. make as per direction of the Engineer- incharge as per UPPWD Sch. No.652, (Bajaj, Crompton, Philips, Wipro Make) |
| 19 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.(25 Amp. TPN) |
| 20 | Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect.(Bajaj /Philips/Wipro/Crompton Make) |
| 21 | Supply and laying of 10 sq.mm 4 core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have it's own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. (Cable laid in Ex. DWC Pipe) (Polycab /KEI/ Havells/ Grandley/Gloster Make ) |
| 22 | S/F of palm or pin type copper tin plated cable socket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (c) 10 sq. mm |
| 23 | S/F of brass nickel Plated compression gland for PVC insulated and armoured served sheated, underground cable including rubber ring etc. comlete in all respects.the armouring of the cable shall be properly connected with the earth as per direction of Engineer- incharge as per UPPWD sch. no. 503 (b) 10 sq. mm 4 core |
| 24 | Supply and wring of submain with 03 no of 2.5 sqmm FRLSH PVC insulated 1100 V grade single cor multistrand copper conductor cable existing conduit complete with supply of all material,labour and T&P |
| 25 | Painting of ST/Old High Mast pole and all mountings on it with two coats of aluminium paints with an under coat of red oxide paint upto10 M. support above the ground level as per direction of Engineer in-charge of work/site including T&P , men & material required for proper completion of work. to be painted 150(for 1 year) x 3(for 3 year)=450 |
| 26 | Painting letters (Pole no.) 2.5 cm upto 8.0 cm size complete on street light pole/panel/other electrical properties under UPSIDA including cost of all material men and T&P complete in all respect |
| 27 | Strengthening of ST/Octogonal pole/High Mast/Panel, foundation by providing new concreting including broken of weak foundation,excavation below upto Ground level,Surface finishing and painting with white cement and dark yellow colour cost of all material men and T&P complete in all respect |
| 28 | Tree Branches Triming for removing dark spots including cost of all material men and T&P complete in all respect rates |
| 29 | Supply, sagging, jointing and binding of insulated ACSR Weasel conductor including cost of aluminium tape binding and jointing sleaves etc. complete in all respect rate ED-II/297/07.11.2023 |
| 30 | Dismantling & regrouting of street light /LT line 12 tilt/sick bend/ STP pole in 1:3:6 ratio cement concrete with stone pad including strengthening of pole by providing additional 4no. Support of 65X65X6 mm or higher size MS angle in suitable length with help of welding/cutting with grouting as per technical specifications. (as per UPPWD approved make list) |
| 31 | Supply & erection of \\"D\\" clamps of 38 mm x 6 mm flat iron for wall /roof type service bracket with bolts, nuts etc.complete in all respects including painting with aluminium paint . UPPWD Sh. No. 624 |
| 32 | Supply & Fixing of 32 MM Dia 1.20 Mtr long G.I Pipe Bracket For Fixing of LED lights complete in all respects with clamp etc as per sanctioned vide |
| 33 | Supply & fixing of as per Design Suitable for Fixing Shackle Insulator , Made out of size 50x6 mm M.S.flat Including all bolts with nuts and washers etc. complete in all respect as per UPSIDC Sch. No. 13.1 |
| 34 | Supply & fixing of 100 x 110 mm shackle insulator 100 x 80 mm pin insulator including GI volt spindle, nuts etc. as pre UPPWD Sch. No. 621 |
| 35 | Charges for maintenance ,proper watch and ward of entire electrical system of Street Light and High Mast Tower,cables,conductors,poles,panels etc and all other available material as per direction of engineer in charge for road lightng in IA to cover the general supervision for execution of work including dismantling and re fixing of all street light of UPSIDA during the period of AMC for 12 months (01 Electrican and 01 Helper for Each Site X 2=Rate taken form as per HO order UPSIDA Electrican 14498.00 + Helper11029.87=25527.87per month for 2 site) as per complete. |
| 36 | Lowering / Lifting of 30/16/12.5 Mtr. High mast lighting system complete in T&P men & material required proper completion of work etc. |
| 37 | S/F of Trailing Cable for High Mast lighting system complete including all T&P men and material required for proper completion of work . |
| 38 | S/Oiling of winch machine for High Mast lighting system complete including all T&P men and material required for proper completion of work . |
| 39 | Supply & Fixing of Male-Femal plug & socket for Hight Mast lighting system complete including all T&P men material required for proper completion of work as complete in all respect. |
| 40 | S/F of 6 Amp.To 32 Amp. SP MCB (10KA) C curve Cat-B complete in all respect. (1st year =50%, 2nd year=25%, 3rd year=25%) |
| 41 | S/F of 63 Amp. 4Pole MCB (10KA) C curve Cat-B complete in all respect.(1st year =50%, 2nd year=25%, 3rd year=25%) |
| 42 | S/F of heavy duty cadmium plated copper connector with end plate complete in all respects (c) four way connector HKM 100 as per complete. |
| 43 | S/F of 3-phase, 63A, 415V ML-3/4 power contactor MDS/L&T make complete including all T&P man and material required for proper completion of work as per complete. |
| 44 | S/F of Astronomical time switch (timer clock) L&T/Siemens/C&S make complete including all T&P men and material required for proper completion of work as per complete(1st year =50%, 2nd year=25%, 3rd year=25%) |
| 45 | Supply and wiring of (3CX1.5sqmm copper wire) for High Mast Lighting system complete including all T&P men and material required for proper completion of work as per directed by Engineer I/C. |
| 46 | Dismantaling & Re- Fixing of LED Street Light complete in all respect |
| 47 | Supply & Fixing of 63 Amp. 415 V metal clad T.P.N. rewireable type switch fuse unit on angle iron bracket complete in all respect. CAT B |
| 48 | Supply & fixing of driver suitable for (110 to 130 watt) LED street light / 50 to 200Watt Flood lights as per same makes that’s are installed at site completein all respect . |
| 49 | Supply & fixing of MCPCB (Metal Core Printed Circuit Board) with LED & Lance (110 to 130 watt) / 50 to 200Watt Flood lights as per same makes that’s are installed at site completein all respect .(1st year =50%, 2nd year=25%, 3rd year=25%) |
| 50 | Supply & Fixing of Glass suitable for installed (110 to 130 watt) LED street light / 50 to 200Watt Flood lights as per same makes that’s are installed at site completein all respect. (1st year =50%, 2nd year=25%, 3rd year=25%) |
| 51 | Supply & fixing of LDR (Light Dependent Resistor) suitable for installed (110 to 130 watt) LED street light / 50 to 200Watt Flood lights as per same makes that’s are installed at site completein all respect . |
| 52 | Supply & fixing of SPD (Surge Protection Device) suitable for (110 to 130 watt) LED street light / 50 to 200Watt Flood lights as per same makes that’s are installed at site completein all respect . |
| 53 | Cost of all material, spares wire fuses,small accessories required for general maint.,cleaning,oiling etc.to keep the entire installation in perfect working order during AMC period complete in all respect. as per complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysSep 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender