Tender For Special Repairs Of R-Class Simulator Classroom And Roof Treatment Of Kuruvila Block (P-01) At installation Dronacharya
Tender Overview
Project Description
Tender for Special Repairs Of R-Class Simulator Classroom And Roof Treatment Of Kuruvila Block (P-01) At installation Dronacharya
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-Sep-2026 | amendment01 | Date | 12-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down old existing water proofing APP membrane only of any thickness from the roof surface, parapets and walls and removing out of MoD land complete all as specified and as directed by Engr-in-Charge |
| 2 | Demolition of cement concrete including cement screed roof tiles of any description and in any position not otherwise specifically provided for and removing out of MoD land complete all as specified and directed . |
| 3 | For filling opening (holes in roof slab)M&L for filling the old dummy cable opening /holes over the roof slab, 75 mm to 100mm dia and depth thickness of slab with chemical Grout including chipping old concrete, removing dummy cable pieces and cleaning the opening, etc complete all as specified . Make: FOSROC (Conbextra GP 2)/BOSTIC (Flow fill Grout GP)/SIKA (Grout 214) |
| 4 | For crack filling over roof slabCutting the Groove 5 mm wide and 5 mm deep on the terrace mother slab whereever cracks are observed, cleaned with blower and Providing and applying low viscous epoxy grout Fosroc Nitofill EPLV into the grooves complete all as specified and as directed. |
| 5 | For injection grouting at points of leakage (soffit of roof ceiling)Providing and installing mechanical injection grouting ports and injecting rapid foaming and setting resin PU foam injection Fosroc Nitofill 11R grout which reacts with contact of water and seal the crack and making waterproofing complete all as specified and as directed. |
| 6 | For crack filling (soffit of roof ceiling)Cutting the V groove 6-8mm wide on the soffit of slab/ ceiling surface 10mm deep whereever cracks are observed, cleaned and Providing and applying sealing the crack with Fosroc Nituseal PU40N/Nitoseal PU50 complete all as specified and as directed. |
| 7 | M&L for Prepration for chemical waterproofing treatment as per following specification complete all as specified and as directed by Engr-in-Charge :(i) Grinding the RCC roof slab surface with machenical grinder to make the surface even and remove all the undulations,followed by cleaning, washing, removing all dirt/ dust using electrical blower complete.(ii) Applying cement slurry coat admixed with Fosroc Nitobond SBR Latex as per manufacturers instructions over the cleaned surface and providing and laying 45 GSM fibre mesh embedded in cement slurry. (iii) Finishing the depressions using polymerised mortar admixed with Nitobond SBR Latex. |
| 8 | M & L for application of chemical water proofing treatment as per following specification complete all as specified and as directed by Engr-in-Charge :-(i) Applying a coat of Epoxy primer, Fosroc Nitoproof WB Primer, a two component product that is mixed as per manufactuer's specification and is diluted with double quantity of water. It is applied by roller at a coverage of 8-10 m/liter. The applied primer shall reach tack-free condition before waterproffing coating is applied.(ii) Application of Two coats of Fosroc Nitoproof 600 PF Polyurethane elastomeric seamless waterproofing coating of DFT 1.30 mm wtih a coverage of 2 kg/Sqm, a single component pitch free polyurethane based coating with roller that cures by reaction with atmospheric moisture to form a tough but flexible waterproofing membrane, The second coat should be applied in perpendicular direction to the First coat. Termination to be done on wall extending the coating to min.150mm height above the finished floor level.Nitoproof 600 PF having a elongation capacity of over 400% The material shall comply to - ASTM C 836. Elongation (ASTM D412) : >400 %, Tensile Strength of 2.5 N/mm* (ASTM D 412) : >400% , Tensile Strength of 2.5 N/mm (ASTM D 412)Specific gravity : 1.4 g/cc, Solid content: 85%, Modulus @ 100% elongation (ASTM D412): 0.62 N/mm?, Tear resistance (ASTM D624) : 15 N, Water vapour transmission (ASTM E96) : 0.6 g/m/hr., Water permeability @ 5 bar : Nil, Shore A hardness (ASTM D2240) : 60Note: (i) Flood Test Prior to placement of screed protection, flood to a minimum depth of 50mm of water for 24 hours. Drains shall be plugged and barriers placed to contain the water. (ii) Item No 3 to 8 shall be executed by authorized applicators of the manufacturers only. |
| 9 | M&L for providing and fixing 150 GSM non woven Polypropylene geo textile membrane with over lap of minimum 50mm as protective medium before screed concrete works over waterproofing treatment complete all as specfied and as directed. |
| 10 | M&L M20 grade Ready mix concrete layer as in screed concrete course laid in pannels over roof treatment including necessary formwork and filler boards to maintain proper slope, finished even and smooth without using extra cement complete all as specified and as directed. |
| 11 | Cutting of construction joints 25 mm deep and 10 mm wide by early entry saw cut using diamond by cutter of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and the debris. Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. Placing of closed cell medium density, crossed linked polyethylene foam backup rod of 12 mm dia, application of bond breake tape on top of back up rod for complete width of the joint and filled with polyurethane based sealant complying with BS-5212, BS 4254 and EN- 141875 2003, having minimum 10 year performance guarantee, applying masked tape on the edges of joints and removing the masking tape after filling of sealant as per the method specified by the manufacturer complete as specified and directed Make : Fosroc/ Bostik/ SIKA |
| 12 | M&L for chipping and removing all damaged and de-bonded/spalled concrete and plaster from the roof projections, facia, ceilings, chajja, columns etc manually or mechanically so as to expose the corroded reinforcement bars, complete all as specified and as directed. |
| 13 | M&L for application Rust Remover (Fosroc Reebaklens RR or equivalent in BOSTIC & SIKA) to remove the excess rust on the surface of the reinforcement bars and leave it for one day, The surface to be wiped and cleaned. After 24 hours Anti-corrosion coating of Zinc primer (Fosroc Nitozinc Primer or equivalent in BOSTIC & SIKA) on the reinforcement bars to prevent further corrosion complete all as specified and directed by Engineer-in-charge. |
| 14 | M&L for application of a coat of epoxy based bond coat (with Fosroc Nitobond EP or equivalent in BOSTIC & SIKA) over the entire spalled surface to receive the forthcoming repair mortar and plastering with SBR bonding agent chemical cum cement mortar/concrete modifier modified cement mortar (1:4) to an average thickness of 30-40 mm (applied in two layers not exceeding 20mm each), including the cost of all materials, scaffolding as required complete. |
| 15 | Dismantling wrought iron or mild steel work (MS plates cable duct covers & MS Railing etc) of any description not otherwise provided for complete all as specified and directed. |
| 16 | M&L for providing and fixing stainless steel (Grade 304) railing, balusters, ladder made of hollow tubes, stairs, frame work etc including welding, grinding, buffing, polishing and making curvature (where ever required) with necessary accessories, like bends, decorative cups etc including fixing the railing with stainless steel bar hold fast, dash fasteners, nut bolts etc, to the slab, steps, columns, beams, etc with suitable arrangement, complete all as specified and directed. Note: (1) Make and Grade shall be clearly engraved on each sections. |
| 17 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 18 | M&L 100 mm thick PCC type D-2, 1:4:8, using 40 mm graded stone aggreage as in sub base, etc. complete all as specified and directed. |
| 19 | M&L 25 mm thick PCC type B-1, 1:2:4, using 20 mm graded stone aggreage as in floors, levelling course, etc. complete all as specified and directed. |
| 20 | Dismantling floor, hearth, mossaic tiles or skirting/wall tiling including cement mortar bedding screed and plaster (but not backing), and and rubbish off the premises or filling the old ducts as directed by Engr-in charge complete all as specified and directed. |
| 21 | Roughening surfaces of old concrete floor/ mossaic floor by chipping, picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed. |
| 22 | M&L PCC type B-1, 1:2:4, using 20 mm graded stone aggreage as in floors, coping, levelling course, for filling hold fast etc. complete all as specified and directed. |
| 23 | M&L for Virified coloured premium tiles 10 mm thick area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm as in floors, and shall be jointed in neat cement slurry and pointed in paste pigment to tile shade etc. over and including 15 mm thick screed bedding layers in cement mortar 1:6 for laying floor finishes tiles etc. complete all as specified and directed. |
| 24 | M&L for Virified coloured premium tiles 10 mm thick area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqmas as in skirting/dado including necessary cutting etc over and including 10 mm thick plaster in CM 1:4 on brick or concrete surfaces, for receiving wall tiles complete all as specified and directed. |
| 25 | Dismantling old false ceiling boards with grid any discription, including hanging wire/ suspenders complete all as specified and as directed. |
| 26 | M&L for 5 mm thick plain embossed PVC false ceiling boards of size 595 mm x 595 mm of density 600 Kg/Cum, plain colour decorative type fixed with and including pre powder coated white GI snap grid frame work (Make: Everest, Armstrong etc) of size, Main runner 24x38x0.32 mm, cross tee 24x28x0.3 mm and wall angle 19x22x0.4 mm to placed at desired level fixed with 4mm dia GI suspender wire @ 1.20 center to centre with wooden rafter/purlins complete all as specified and directed by Engr-in-Charge. Make:- SMP Emplex Magma, Sintex Industries, Madhu Industries, etc |
| 27 | Taking down chowkats or frames not exc. 1.50 Sqm each with shutters (without taking off shutters from the frame) etc. complete all as specified and directed. |
| 28 | Taking down chowkats or frames exc. 1.5 Sqm and not exc 4.00 sqm each with shutters (without taking off shutters from the frame) etc. complete all as specified and directed. |
| 29 | S&F factory made uPVC white colour Sliding window Three track frame with shutters, Area not exceeding 2.00 sqm each made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners and sealed with silicon sealent alround the frame internal and external side, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system including two shutters with glass and including one shutter with Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories) |
| 30 | Providing and fixing factory made uPVC white colour casement (Openable) Door frame with single/double shutter made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, Frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing with selected quality glass. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) |
| 31 | S&F 5 mm thick plain transparent glass, ordinary quality and glazing with necessary required EPDM rubber/ neoprene gasket etc. in each pane etc. complete all as specified and directed. |
| 32 | S&F for powder coated aluminium coated deco grill of approved colour, design & pattern, with approved standard section fixed to frame with and including frame aluminium frame work hollow, 'H'/ 'F' channels by stainless steel screws complete all as specified and directed. |
| 33 | Demollition of Cement concrete (unreinforced) n exc 15 cm thickness (below or above ground floors) complete all as specified and directed . |
| 34 | Demolition of brick / concrete block masonry built in cement mortar complete all as specified and directed. |
| 35 | M&L precast cement concrete 1:3:6, type C0 (12.50 mm graded stone aggragate) block masonary with solid blocks, exc. 10 cm in width and setting in CM 1:6 for closing door/window openings etc. complete all as specified and directed. |
| 36 | M&L precast cement concrete 1:3:6, type C0 (12.50 mm graded stone aggragate) block masonary with solid blocks, n.exc. 10 cm in width and setting in CM 1:4 complete all as specified and directed. |
| 37 | M&L for 10 mm thick plastering in CM 1:6, on internal walls , window jambs finished even and smooth w/o using extra cement etc complete all as specified and directed. |
| 38 | Taking down cement plaster of any description on walls including raking out joints, hacking for key scrubbing down with water etc |
| 39 | M&L for rendering 15 mm thick in two coats (5 mm thick in cement mortar 1:4 with water proofing compound over 10 mm thick plaster in CM 1:6) on fair faces of brick work or concrete blocks surfaces finished even and smooth without using extra cement including (Note- water proofing compound shall be measured and paid seperately) . |
| 40 | M&L for 15 mm thick plastering in CM 1:4 in two layers 10mm + 5mm on ceiling and chajja cement finished even and smooth w/o using extra cement etc |
| 41 | Demolition of Stone slabs and tiles of any description or thickness in platforms, floors, aprons laid in cement mortar etc. and rubbish off the premises all as specified and as directed. |
| 42 | M&L 20 mm thick screed bedding layers in cement mortar 1:4 for laying topping layer of etc. complete all as specified and directed. |
| 43 | M&L for Granite 18 mm thick work (Rounded at edges and polished) in floors, steps treads and risers in one piece, or door cills, platforms, urinal partition etc and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite as approved by GE complete all as specified and directed. |
| 44 | Supply and installation of Zebra blinds (Green Guard Certificated ROHS Fabric), Anti-Wrinkle and Dust Proof, 250 GSM, Rolling Mechanism & material - Aluminum alloy weight 3.6 Kgs/ 15’ Length - Plastic gear set with steel coil inside - Polyester operated chain with drop 46” - Aluminum bottom rod of weight 3.2 kgs/15’ length - Support bracket of iron alloy with complete accessories required for installation/ fitting of blinds. Note:- Net window opening will be measured. |
| 45 | Supply & Installation of White Board size ( 8 feet x 4 feet ) for class room made of Aluminium frame, and Melamine board with built-in wall-hanging clips or wall-mounting clamps complete all as specified and as directed by Engr-in-Charge. |
| 46 | Complete removal of existing treatment by scrapping with steel scrapers, washing, rubbing down complete all as specified and directed. |
| 47 | M&L for 1.50 mm thick (in two layers 1mm+0.5mm) cement based wall care putty on walls etc. complete all as specified and directed. |
| 48 | M&L for applying Two or more coats of Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new and old prepaired surfaces complete all as specified and directed by Engr-in-Charge. |
| 49 | M&L for application of two coats of distemper Acrylic emulsion on wall surfaces over a coat of interior primer complete all as specified and as directed. |
| 50 | M&L for two coats of of distemper acrylic emulsion over ceiling surfaces over a coat of interior primer etc. complete all as specified and directed. |
| 51 | M&L for applying a coats of exterior emulsion weather proof paint with fungal resistance, dirt resistance properties on external wall all as specified and directed by Engineer-in-Charge. |
| 52 | M&L for preparation of previously treated surface of wall and applying a coat of distemper acrylic emultion including filling the cracks and depression with putty complete all as specified and directed. |
| 53 | M&L for preparation of previously treated surface of ceiling and applying a coat of distemper acrylic emultion including filling the cracks and depression with putty complete all as specified and directed. |
| 54 | INTERNAL ELECTRIFICATION |
| 55 | Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete,including fixture and fittings such as switches, ceiling roses, Pendants, regulators, sockets, light fittings etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface/location complete all as specified and as directed |
| 56 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Metal socket enclosure Switch , etc and making good to disturbed surface complete all as specified and as directed |
| 57 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and as directed |
| 58 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and as directed. |
| 59 | M & L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),complete with PVC insulated and unsheathed flame retardant low smoke ( FRLS ) cable of 1.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade ISI marked and including PVC casing caping with fixing accessories in wall/roof/floor etc. ISI marked including common earth dolly including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete including arrange necessary factory made modular type metal boxes and coverplates to modular type switch, sockets accessories etc and matching with the existing surfaces including colour washing all as specified for One light/ceiling fan point controlled by one switch ( Make - Havells, V-guard, finolex, Poly cab) |
| 60 | M & L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),complete with PVC insulated and unsheathed flame retardant low smoke ( FRLS ) cable of 1.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade ISI marked and including PVC casing caping with fixing accessories in wall/roof/floor etc. ISI marked including common earth dolly including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete including arrange necessary factory made modular type metal boxes and coverplates to modular type switch, sockets accessories etc and matching with the existing surfaces including colour washing all as specified for One 3/5 pin socket 5 Amp on same board, with 1.5 sqmm wire with 1.5 sqmm earth wire ( Make - Havells, V-guard, finolex, Poly cab) |
| 61 | M & L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),complete with PVC insulated and unsheathed flame retardant low smoke ( FRLS ) cable of 1.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade ISI marked and including PVC casing caping with fixing accessories in wall/roof/floor etc. ISI marked including common earth dolly including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete including arrange necessary factory made modular type metal boxes and coverplates to modular type switch, sockets accessories etc and matching with the existing surfaces including colour washing all as specified for one 3/5 pin socket 5 Amp on independent board.with 1.5 sqmm wire with 1.5 sqmm earth wire ( Make - Havells, V-guard, finolex, Poly cab) |
| 62 | M & L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),complete with PVC insulated and unsheathed flame retardant low smoke ( FRLS ) cable of 2.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade ISI marked and including PVC casing caping with fixing accessories in wall/roof/floor etc. ISI marked including common earth dolly including 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete including arrange necessary factory made modular type metal boxes and coverplates to modular type switch, sockets accessories etc and matching with the existing surfaces including colour washing all as specified for 3/5 pin socket outlet 15 Amps, independent with 2.5 Sqmm single core PVC insulated unsheathed 1100 Volts grade multi stranded copper conductor FRLS complete with 2.50 Sqmm stranded copper conductor PVC insulated unsheathed earth wire and connecting to earth dolly complete all as specified and directed ( Make - Havells, V-guard, finolex, Poly cab) |
| 63 | M & L for submain wiring with two run single core PVC insulated unsheathed cable 1100 volts, grade having stranded copper conductor of 2 X 6.0 sqmm nominal cross sectional area FRLS drawn through PVC casing and capping including one run of single core PVC insulated unsheathed copper conductor of size 1 X6.0 Sqmm for earth continuity conductor connected to earth dolly complete all as specified and as directed. Note :- I. Two runs of Copper Conductor of PVC insulated unsheathed 6.0 Sqmm and one run of size 6.0 Sqmm PVC insulated unsheathed copper wire & PVC casing caping will be measured as a single length. |
| 64 | M & L for submain wiring with two run single core PVC insulated unsheathed cable 1100 volts, grade having stranded copper conductor of 2 X 4.0 sqmm nominal cross sectional area FRLS drawn through PVC casing and capping including one run of single core PVC insulated unsheathed copper conductor of size1 X 4.0 Sqmm for earth continuity conductor connected to earth dolly complete all as specified and as directed. Note :- I. Two runs of Copper Conductor of PVC insulated unsheathed 4.0 Sqmm and one run of size 4.0 Sqmm PVC insulated unsheathed copper wire & PVC casing caping will be measured as a single length. |
| 65 | S & F ceiling rose surface type bakelite 65x50 mm two to three terminal suitable for 230 Volts AC 6 Amps, complete all as specified and as directed. |
| 66 | Supply and fix in repairs of sheet metal enclosure distribution board, triple pole and neutral, vertical type, AC, 415 volt, 04 way with 200 Amp rated copper bus bar and double door complete all as specified & directed and comprising of the following :(a) MCCB 125 Amp 04 pole AC 415 Volt of 25 KA breaking capacity complete 01 No (incoming)(b) MCB SP AC 240 V of upto 40 Amps 10 KA 'C' Curve capacity complete 12 No (outgoing) |
| 67 | S & F in replacement of distribution board sheet metal enclosure factory made fixed flush with wall inside the nitches or outside on wall surface suitable for mounting isolators & MCB's etc. 240 Volts, 200 Amps rated bus bar capacity SPN 12 way double door complete all as specified and as directed. Make -Legrand/L&T/ABB/Havlles |
| 68 | S & F in replacement of distribution board sheet metal enclosure factory made fixed flush with wall inside the nitches or outside on wall surface suitable for mounting isolators & MCB's etc. 240 Volts, 200 Amps rated bus bar capacity SPN 8 way double door complete all as specified and as directed. Make -Legrand/L&T/ABB/Havlles |
| 69 | S & F in replacement of distribution board sheet metal enclosure factory made fixed flush with wall inside the nitches or outside on wall surface suitable for mounting isolators & MCB's etc. 240 Volts, 200 Amps rated bus bar capacity SPN 4 way double door complete all as specified and as directed. Make -Legrand/L&T/ABB/Havlles |
| 70 | S & F in replacement of distribution board sheet metal enclosure factory made fixed flush with wall inside the nitches or outside on wall surface suitable for mounting isolators & MCB's etc. 240 Volts, withoutbus bar capacity SPN 2 way single door complete all as specified and as directed. Make -Legrand/L&T/ABB/Havlles |
| 71 | MCB ,SP 10 to 40 Amps C series 10 KA breaking capacity 240 Volts complete all as specified and as directed. Make:- Havells/ Legrand/L&T/SEMENS. |
| 72 | MCB ,SPN 63 Amps C series 10 KA breaking capacity 240 Volts. Make:- Havells/Legrand/L&T/SEMENS. |
| 73 | MCB ,SPN 40 Amps C series 10 KA breaking capacity 240 Volts. Make:- Havells/Legrand/L&T/SEMENS. |
| 74 | MCB ,DP 40 Amps C series 10 KA breaking capacity 240 Volts. Make:- Havells/Legrand/L&T/SEMENS. |
| 75 | M & L Modular switch 1 way 6A,1 module, all as specified and directed. |
| 76 | M & L Modular switch 1 way 16A,1 module, all as specified and directed. |
| 77 | M & L modular Socket, 6A - 2/3 pin combined 2 module all as specified and directed. |
| 78 | M & L Modular Socket 6A/16A - 2/3 pin combined 2 module all as specified and directed. |
| 79 | Supply and fix in replacement of surface mounted LED light fitting four feet long, 36 Watt with comprises of aluminium extruded channel, extruded aluminium body, integrated electronic driver, etc and all accessories pre-wired including connecting up complete all specified and as directed. Make : Havells or equivalent Cropmpton / Philips |
| 80 | Supply and fix LED security light 35 W IP 65 connecting upwith twin core twisted flexible copper conductor cable with suitable sizealong with provision of 25 mm dia GI pipe bracket long 4 feet with 135 degree bend fixed on wall with all fixing accessories like clamps nuts bolts etc complete all as specified and as directed Make: Havells or equivalent Cropmpton / Philips |
| 81 | Supply and fixing LED luminaire 600 mm x 600 mm,40 watt, 220 V AC recessed type with highefficiency PMMA diffuser soft glare free light completewith driver, holders & LED lamp suitable for ceiling including connecting up with driver threecore flexible copper conductor cases of suitable size complete all as specified |
| 82 | Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB,240 volt, 20 Amps complete all as specified & directed.Make: Havells, L& T,ABB |
| 83 | M&L XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 95 Sqmm 3.5 core , 1100 volt grade ,Heavy duty conforming to IS :7098 (Part 2) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and as directed. |
| 84 | Supplying and laying in repairs incl taking down old GI tubing light grade incl all accessories for encasing cables for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works all as specified and directed of size 50 mm bore. |
| 85 | Supply and installed Hi wall mounted air cooled star rated split type air conditioner, electric driven ,230 V,single phase indoor unit,outdoor unit complete with cordless remote control unit and with in built air ioniser, plasma filter, for better indoor air quality with minimum 5 star rating and BEE 5.0 of capacity 2.0 TR complete all as specified and directed. Make :- Blue Star, LG, Carrier, Diakin |
| 86 | Voltage stabilizer of automatic operation ,single phase ,copper wounded ,naturally air cooled indoor, type and designed, for input variation between 170 V to 250 V with out voltage stabilized at 230 V accuracy +/- 2.5 and of capacity 5.0 KVA Make :- V-Guard, Servo, Blue bird, Microtek. |
| 87 | Dismantling of existing old vintage UNSV AC plant duct removing the building wall surface,duct made out of GI sheets any gauge size up to 0.75Mtr x0.75 Mtr and maching with existing disturbed wall surface making good surface smooth with surrounding area complete all as specified and as directed Engr-in - charge and including complete duct taking out shifiting to site to deposited MES AGE EM OFFICE storeyard. |
| 88 | Earthing complete with GI earth plate electrode 60cm x 60cm x 6mm thick buried in ground vertically to a depth not less than 2.25 meters below ground level with the top edge of earth plate not less than 1.5 meters below ground level connected to galvanised iron earth wire 4mm dia by means of bolts, nuts, check nuts, washers maade out of galvanised iron steel all as shown in electrical plate No 3 of SSR Part I and earth wire protected by galvanised pipe light grade 15mm bore and connected to LT panel/ pole through test point including necessary earth work and excavation in any type of soil, GI light grade 15mm bore watering pipe with funnel and wire brush, PCC 1:2:4 type B1 chamber with 20mm thick RCC 1:2:4 type B1 , covere slab with 6mm dia MS bars at 100mm c/c both ways with MS hook 6mm dia etc complete all as specified and directed and testing on complete |
| 89 | LIGHTNING ARRESTOR |
| 90 | Taking down aluminium/GI/copper strip of upto 32 x 6 mm from the inspection box to the earth pit//roof conductors/down conductors and disconnecting insulators from the multi stories buildings/structures/over head tanks etc including porcelain insulators, complete all as specified and directed. |
| 91 | Taking down the inspection box of any size, jointing togather copper/aluminium /GI strip with all accessories complete all as specified and directed. |
| 92 | Taking down GI tubing medium grade 40 mm & 50 mm including dismantling PCC base/clamps complete all as specified and directed. |
| 93 | Taking down earth with electrode/plate complete all as specified and directed. |
| 94 | Taking down air termination aluminium/copper single pointed rod 12mm dia, 300 mm long complete all as specified and directed. |
| 95 | M/L for test point terminal block made of gun metal or phosphorus bronze size 75 x75 x 25 mm drilled & screwed including 3 Nos 8mm dia 25 mm long hex. Head screw complete all as specified and directed. |
| 96 | M/L for Aluminium strip 25 x 3.15 mm with saddles and fixing screw etc,on wall by using porcelain insulated clamps with connecting to roof conductor and down conductor,test point etc above ground complete all as specified and as directed |
| 97 | M/L for GI strip 32 x 6 mm mm fixed on wall/floor by using porcelain insulated clamps with connecting to wall and connecting to roof conductor and down conductor,test point etc buried in ground complete all as specified and as directed |
| 98 | Supply and Fixing of Air termination single pointed aluminium rod 12 mm x 300 mm long complete fixed to aluminium strip on roof with MS clamps, nuts & bolts complete all as specified. |
| 99 | S&F junction box made of HDPE material having IP 65 protection heavy duty water proof ,weather poorf,for outdoor installation of size 205mm x255mm x112mm fixed with ,Test point terminal block made of gun metal or phosphorus bronze size 75 x75 x 25 mm with holes ,nuts blots,whashers complete all specified and as directed by Engr- in -charge.(Make:Hansel,Sindex or equivelent) |
| 100 | Taking down split type air conditioner 1.5/2.0 ton capacity any type , any description incl indoor and outdoor units complete and all mounted accessories , keeping in safe custody till carrying out addition alteration and refixing the same after repair and complete servicing of indoor unit, out door unit, cleaning,carried out as per site requirement of any type , any description small spare parts, gas charging and replacement using complete indoor,out door units and including in aditional new copper pipe as per site requirement and mounting clamps completely and testing carried out smoothly functioning to the satisfaction of Engr in Charge. |
| 101 | M&L in repair for earthing complete with galvanized steel earth plate 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanized iron strip size 32x6mm as earthing lead by means of bolt ,nuts, check nuts and washer of galvanized iron or steel besides welding of all joints as shown in drawing and including excavation and earth work, G.I.pipe light grade 40 mm bore for protection of G.I.strip from earth electrode to and including the earth test point of galvanised iron /steel of size 75 x75x 25 mm , supplying and laying charcoal dust, common salt PCC 1:2:4 type B-I using 20 mm stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round ,PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed . Note :- Cost of earthing strip & GI pipe 40mm up to 7.5 m shall be included in cost of above item. |
| 102 | Dismantling of existing AC plant duct removing the building roop/wall surface,duct made out of GI sheets any gauge size up to 1.5 x2.5 mtr and maching with existing disturbed wall /roop surface making good surface smooth with surrounding area complete all as specified and as directed Engr-in - charge and including complete duct taking out shifiting to site to deposited MES AGE EM OFFICE storeyard. |
| 103 | Supplying and laying in repairs incl taking down old GI tubing light grade of size 40 mm dia incl all accessories for encasing cables for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works all as specified and directed.(MS works will be measured under seperate item in Schedule) |
| 104 | Supplying and laying in repairs incl taking down old GI tubing light grade of size 50 mm dia incl all accessories for encasing cables for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works all as specified and directed. (MS works will be measured under seperate item in Schedule) |
| 105 | Excavating and cutting the existing hard standing to a width not exc 1.5 m and not exc 1.5 m in depth and marking good after laying GI pipe for encasing GI strips complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender