BOQ
| Sl. No. | Item Description |
| 1 | Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolisdhed, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and taxture laid over 20 mm thick base cement, mixed with matching pigment, epoxy thouch ups, including rubbing curing, mouldign and polishing of edges to give high gloss finish etc, complete at all levels. (As per DSR 8.2- 8.2.2.1 Granite Stone Slab of Colour black, Cherry/Ruby red) area of slab upto 0.50sqm |
| 2 | Providing and fixing cramps of required size & shape in RCC/CC/Brick masonry backing with cement mortar 1:2 (1 cement : 2 coarse sand) including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately) (As per DSR 8.7- 8.7.2 Stainless steel cramps) |
| 3 | Providing and fixing expansion hold fasteners on C.C./R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bold etc. complete (As per DSR 8.8- 8.8.1.2 Fasterner with threaded dia 10mm) |
| 4 | Extra for fixing marble/granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete (As per DSR 8.4) |
| 5 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc. , including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer in Charge. (As per DSR 8.3) |
| 6 | Mirror Polishing on marble work/Granite work/Stoe work where ever required to giev high gloss finish complete. (As per DSR 8.6) |
| 7 | C- The fastening brackets of Aluminium alloy 6005 T5/MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour componenet, the cost of all mock ups at site, cost of all samples of the indidual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding till the handing over of the building for occupation, Base fram work for ACP cladding is payable under the relevant anuminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance charactgeristics all complete as per theArchitectural drawing and as directed by the Engineer in charge. However for the purpose of payment, only the actual area on the external face of the curtian wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. (As per DSR 8.32 C) |
| 8 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (As per DSR 13.80) |
| 9 | Finishing walls with Premium Acrtylic Smooth exterior paint with Silicone additives of requried shade:- New work (Two or More coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @0.90 litre/10sqm) (As per DSR 13.47, 13.47.1) |
| 10 | Providing and fixing Name Words of 12\\" to 15\\" long made of SS 304 steel of golden colour including brackets, holfast and other fixtuers. |
| 11 | Providing and fixing Logo of 15\\" to 18\\" long made of SS 304 steel of golden colour with UV print including brackets, holfast and other fixtuers. |
| 12 | Wiring for light point / fan point / exaust fan point / call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit with Modular switch,modular plate , suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable as required.Group - C |
| 13 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door |
| 14 | Supplying and fixing 5 A to 32 A rating,Single Pole 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. |
| 15 | Supplying and fixing 5 A to 32 A rating,Double Pole 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 16 | Description LED Down lighter 8 w to 10 w (SMD Type) (System lumen Unit Rate efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) |
| 17 | LED Down lighter (COB Type) 18 w (System lumen efficacy ≥105 < 120 lm/Watt ). Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) |
| 18 | LED Flood Light 50 W, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 OC to 50 OC, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, 54 DELHI SCHEDULE OF RATES (E&M)-2025 EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM 21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) 135 Im/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 daySep 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender