Housing Urban and Rular Development Government Departments Closing in 6 days TDR #57397175

Tender For Forss2627100235-Construction Of Range Office Tral Awantipora.

Issued by Government Departments · Pulwama, Jammu and Kashmir
Tender Value
57.57 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
6 days left
EMD
1.15 Lakhs
Bank guarantee accepted
Document Fee
1600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pulwama → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Forss2627100235-Construction Of Range Office Tral Awantipora.

BOQ

Name of Work:- FORSS2627100235-Construction of Range Office Tral Awantipora.
Sl. No. Item Description
1CIVIL Part
2Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth anddisposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :
3Providing & Laying of stone soling (dully hand packed)including watering dressing and ramming with all carriages loading un-loading and stacking etc complete
4Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
5Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
6Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
7Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
8Reinforcement for RCC work incld straightning, cutting, bending, placing in position & binding all completeThermo-Mechanically Treated bars of grade Fe-500D or more
9Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns
10Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
11Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms.
12Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers
13Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) including Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
14Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Second class kail wood
15Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
16Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. First class kail wood 30mm.
17Extra for providing glass panes 10kg/sqm (4mm thick) in doors windows and clerestory window shutters (Area of opening for glass panes excld portion inside shall be measured)
18Providing & fixing 30mm thick wire gauze shutters using galvanised MS wire aperture1.4mm wire dia 0.63mm for doors & windows and clerestory windows including bright finished/ black enamelled M.S Butt hinges with necessary screws First class Kail wood.
19Providing and fixing factory made flush door shutters 30 mm thick made of pre-laminated flat pressed three layer particle board conforming to IS: 12823 exterior grade (Grade I Type il) having one side decorative lamination of approved shade and other side balancing lamination including second class teak wood lipping of 25mm widex 12mm thick with necessary screws and black enamelled M.S. butt hinges complete as per directions of Engineer- In-charge.
2015mm Cement Plaster of mix 1:4(1 cement:4 coarse sand).
216 mm cement plaster to ceiling of mix 1:3(1 cement: 3 fine sand)
22Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick
23Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS :15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
24Providing ard fixing 1st quality ceramic glazed floor tiles conforming to IS :15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand] and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
25Cement Concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone agg) finished with a floating coat of neat cement incld. cement slurry but excld the cost of nosing of steps etc complete 50mm thick with 20mm n/s stone agg crushed.
26Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
27Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. Including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-In-Charge. Granite Work.
28Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer
29Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
30Providing and fixing of Hardware fittings (Brass) as per approved samples
31125mm Handle
32150 mm Handle
33100mm Tower bolt
34150mm Tower bolts
35stay hooks
36L-drops 12\\"
37Carriage of materails By Mech.Transport, from source to site of work.
38Stone agg.for an avg lead of 15 km
39Sand for an avg lead of 15 km
40Bricks for an average of 30 kms.
41Septic Tank and Soakage Pit.
42Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth anddisposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :
43Providing & Laying of stone soling (dully hand packed)including watering dressing and ramming with all carriages loading un-loading and stacking etc complete
44Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
45Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
46Reinforcement for RCC work incld straightning, cutting, bending, placing in position & binding all completeThermo-Mechanically Treated bars of grade Fe-500D or more
47Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)
4815mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 coarse sand).
49Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns
50Cement Concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone agg) finished with a floating coat of neat cement incld. cement slurry but excld the cost of nosing of steps etc complete 50mm thick with 20mm n/s stone agg crushed.
51Dry rubble masonry with hard stone using quarry stone including all carriages complete.
52Carriage of materails By Mech.Transport, from source to site of work.
53Stone agg.for an avg lead of 15 km
54Sand for an avg lead of 15 km
55Bricks for an average of 30 kms.
56WATER SUPPLY AND SANITARY INSTALLATIONS FOR RANGE OFFICE TRAL
57Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 liter low level whiteP.V.C. flushing cistern, including flush pipe with manually controlleddevice (handle lever), conforming to IS:7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required: W.C. pan with ISI marked white solid plasticseat and lid.
58Providing and fixing CP Brass Single lever telephonic wall mixer of approved quality & make as approved by Engineer in charge. (a) 15 mm nominal dia
59Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
60Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
61Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: 32 mm dia.
62Providing and fixing P.V.C. P & S Trap for water closet or wash basin including P.V.C waste fittings complete:
63Providing and fixing PVC pipes class B including soil waste and vent pipes
64100mm
6575 mm
66Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.
67PN-16 pipe, 16mm OD(SDR-7.4)
68PN-16 pipe , 25mm OD(SDR-7.4)
69Providing and fixing PVC following sanitary items of approved brand complete .
70Door PVC TEE 100 mm
71Door PVC TEE 75 mm
72PVC Collar 100 mm
73PVC Collar 75 mm
74100X75 mm PVC Reducer
75F Trap 100mm with Jali
76Plain Bend 100mm
77Plain Bend 75mm
78Door Bend 100mm
79Door Bend 75mm
80P/F of CP Cupling of approved make
81P/F of PTMT liquid soap container of approved brand
82Providing and fixing 15 mm nomial board of standard back type C.P. Brass close hole basin mixer pillar tape of approved quality and make weighing not less than 1.97 kg
83Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040mm bowl depth 200mm
84.Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-incharge.
85Providing and fixing 15 mm nominal bore C.P. brass bib cock ofapproved quality conforming to IS : 8931
86Providing and fixing of 50 Ltr Capacity Gyser of 2000 Watt average water heater (white) of approved brand including installation complete.
87Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
88Providing and fixing uplasticized PVC connection pipe with brass unions 15 mm nominal bore
89Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms
90Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
91Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour: 18.73.1 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms.
92Providing and fixing of CP brass sink mixer of standard make incl all fittings and fixtures
93Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
94(TRUSS WORK)
95Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded
96Providing and fixing Hi-rib Colour Coated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(0.50 mm thickness )inlc.ridges and valleys.
97Electrification.
98Wiring for light point/ fan point/exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS/HFFR PVC Insulated copper conductor (Polycab Green/Havell Life guard/ Fenolex/ Salzer/RR/Apar make as desired by engineer Incharge) single core cable in surface/recessed medium class PVC conduit, including cutting the wall and making good the same in casa of recessed condult as required, with cement plaster, wall putty, paint, complete, with modular switch Antibacterial series (Legrand /ABB /Slemens make.), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable etc. as required
99Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire, FRLS/HFFR PVC insulated copper conductor (Polycab Green/Havell Life guard/Fenolex/ Salzer/RR/Apar make as desired by engineer incharge )) single core cable in surface/recessed medium class PVC conduit including cutting the wall and making good the same in case of recessed conduit as required.
100Supplying and fixing suitable size Gl box with modular plate and cover In front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 modular socket outlet and 15/16 A modular switch modular plate. Lable of box, connections etc. as required. Modular Switch & Socket:-antibacterial series (Legrand/ABB/Siemens make.)
101Wiring for lighting circuits/ 6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell life guard/Polycab/Finolex/ Anchor/eq. standard make as desired by engineer incharge ) single core cable in surface/recessed medium class PVC conduit along with 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
102Supplying and fixing suitable size G l box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket :- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /ABB Tvisha make.)
103Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch reconnections etc. as required.
104Supplying & fixing suitable size G l box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP M.C.B, \\"C\\" curve including connections. painting etc. as required.
105Wirng for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell life guard/Polycab/ Finolex/ Anchor/eq. standard make as desired by engineer incharge ), single core cable in surface/ recessed medium Class PVC Conduit as required.
106(a) 2 x 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
107(a ) 2 X6 sq. mm + 1 X 6 sq. mm earth wire
108( b )2 x, 16 sq. mm + 1 X 6 sq. mm earth wire
109Supplying and fixing of following sizes of medium class PVC condult Anchor/Ravindra/ Eq. make along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty, paint, complete
110Providing and fixing of 6-16mm Cu thimbles duly cramped at cable ends
111Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
112Supply installation testing and commissioning of Indicator of Anchor roma plus/Legrand Mylinc/SSK NV/schneider Livia /Crabtree/athena make.) including G l box along with modular base & cover Intake in recess etc. as required
113Sub Head-2 Fixtures and Fittings
114Supply installation testing and commissioning of 18 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 Im/W with Pressure Die cast Aluminium Housing and Heat Sink and P.F.>0.95 ,THD<10%,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, separate driver, heat sink, earthing provision . The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Crompton/Helonix/Havell make / sample to be approved before installation.
115S/F testing and comm. Of 20 Watt 4 ft. wall mounted LED batten with powdered coated aluminum housing & integrated electronic driver with THD<10%.( commercial series) Helonix/ wipro/ Havell make/ equal standard make as directed by engineer incharge.
116Supply, Installation, Testing and Commissioning of 1200 mm sweep, decorative ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50Hz, and including iron hook complete . USHA/orient/Crompton make sample to be approved before installation)
117Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc /ABB/Tysha/schneider Livia /Havell Coral make.
118Supply installation testing and comm. Of 250mm -300mm sweep exhaust fan steel body of havell /USHA/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/window as per site requirement and necessary connections.
119Supplying and fixing following way, triple pole and neutral, sheet steel, MCB distribution board,( Havell/ legrand/ Shinider/SSK make) 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator).
1206 way (4+18)way , Double Door.
121S/F testing and comm. Of MCB's 10 K of the below mentioned capacities in sub main controls legrand C curve/ Schinider/ ABB/equlvalent make as directed by engineer incharge.
122a) 6-32 Amp SP MCB
123b) 40-63amp DP MCB
124Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode, 80mm dia. connecting the plate with main control board by 8- 10 SWG G.I wire with 1/2\\" dia. Full thread brass nut and bolt and washers. Refilling of pit with 2 bags of chemical compound.
125S/L, testing and commissioning of PVC XLPE insulated alluminium un- armoured cable 650 V/1100 V Grade as per IS: 7098 (Part 1)1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.
126a)35 sq.mm 2 core
127Supply installation testing and comm. of flood light 30 W ( warm, white ), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07 with high power LED's as light source with Built-In Potted IP67 electronic LED driver with APFC, lower THD, toughned glass and secondary lens, Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1. Preferred make: Philips/ Havell /Wipro/Crompton make. the job also includes the angle iron stand of suitable size to be grouted in cement concrete with hold fasteners complete job.
128Design, Fabrication, Supplying, Installation, and Testing Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel, floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc.as required.( As per approved design, size may vary as per site requirement.
129Normal INCOMING:
130a)125A 2P MCCB 25 KA including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make.
131b) 2 No of Aluminium Bus Bar of 200 Amp.
132c)Digital meters and phase indicators -1 set.
133d) onload change over switch 63 Amp for generator Front operated. plus SPD /ayps-2, 10-20 KA
134e) 2 No. of Aluminium Bus Bar of 100 Amp
135c)Digital meters and phase indicators -1 set
136Inverter Incommer
137(a) 100 amp DP MCB 10K Legrand/ Shinider/Semiens/ABB make
138(b) 100 Amp 2 strip bus bar
139c)Digital meters and phase indicators -1 set.
140OUTGOING:
141c) 40-63amp DP MCB
142c) space for 12 way MCB's
143Supply installation testing and comm. of invertor battery 150 AH/12V Exide invatubular/ eq standard make as directed by engineer lncharre.
144Supply installation testing and commissioning of Sine Wave Inverter,Capacity 1400-1600VA, ,Supporting 2 no. battery,24 MonthWarranty Safe for sensitive appliances with Sine wave out-put, Autoover-load handling capacity Installation and maintenance friendlyOffers high quality and reliable power back-up solution for officeand homes ,MCB for protection from Input mains,Bypass switch forsupplying output directly from grid in case of Home UPSfault.Noiscless Operations with the help of low harmonic distortion,Intuitive Display to easily understand status of mains availability,battery status, etc.Comprehensive protection against short-circuit,reverse polarity, battery over-charge, deep-discharge etc AdaptiveBattery charging control system technology (ABCC) ensures fasterbattery charging and enhances battery life by around 70%.Supportsa wide battery range, i.e. Flat Plate, Tubular & VRLA (SMF) prafferedmake Luminous/ Microtek/Exide make. The job also includes thePVC Trollies suitale to hold 2 No. Battery and the inverter. (Complete job) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57397175
AUTHORITY Government Departments
TENDER VALUE 57.57 Lakhs
LAST DATE 21-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Forss2627100235-Construction Of Range Office Tral Awantipora.
Basic Detail
Tender No 114/EEA/RNB of 2026-27/5988-98 Dated 08-09-2026
Bidding Type Tender
Location
City Pulwama
State Jammu and Kashmir
Key Dates
Publish Date 08 Sep 2026
Submission Date 21 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 57.57 Lakhs
Tender Fee 1600
EMD 1.15 Lakhs
Exemption Not Available
Document List
12afeb7b-6971-4d1d-b71f-58fb1a3dcf4e.html
BOQ_1091150.xls
Tendernotice_1 (19).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

12afeb7b-6971-4d1d-b71f-58fb1a3dcf4e.html

xls

BOQ_1091150.xls

pdf

Tendernotice_1 (19).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender