Tender For Provision Of Tech Storage Building At Tangtse Under Ge 860 Ews
Tender Value
10.58 Crore
Estimated cost
Bid Submission
26 Oct 2026
22 days left
EMD
8.55 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
leh → Ladakh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Provision Of Tech Storage Building At Tangtse Under Ge 860 Ews
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-Sep-2026 | Corrigendum 01 | Date | 26-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | NOTE: Schedule ‘A’ Part - I to Part -XII are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. |
| 2 | Total amount of Sch 'A' Part - I (BUILDING Works) |
| 3 | Total amount of Sch 'A' Part - II (SITE CLEARANCE,EXCAVATION & EARTH WORK) |
| 4 | Total amount of Sch ‘A’ Part - III (INTERNAL ELECTRIFICATION) |
| 5 | Total amount of Sch ‘A’ Part - IV (INTERNAL WATER SUPPLY) |
| 6 | Total amount of Sch ‘A’ Part - V(PROTECTIVE WORK ) |
| 7 | Total amount of Sch ‘A’ Part - VI(ROAD,PATH AND HARDSTANDING ) |
| 8 | Total amount of Sch ‘A’ Part - VII(SEWAGE DISPOSAL ) |
| 9 | Total amount of Sch ‘A’ Part - VIII(AREA DRAINAGE) |
| 10 | Total amount of Sch ‘A’ Part - IX(LIGHTENING PROTECTION) |
| 11 | Total amount of Sch ‘A’ Part - X(EXTERNAL WATER SUPPLY) |
| 12 | Total amount of Sch 'A' Part - XI (EXTERNAL ELECTRIFICATION) |
| 13 | Total amount of Sch 'A' Part - XII (STAND BY DG SET) |
| 14 | SCH 'A PART - XIII (Miscellaneous B/R and E/M works for Sch 'A' Part-II to Part-XII)Note: This schedule is not pre-priced by MES and the rate indicated as \\"Rs 0.00\\" under Col 5 signifies this fact only |
| 15 | Supply only FRG dunnage block of size 30.00 cm x 30.00cm x20.00 cm |
| 16 | M& L for Excavation in Sign Boards (1.2m x1.2m x 2.7m) post holes PCC 1:4:8 as in fdn, MS work in frame, 1mm thick plain black sheet fixed over frame, reflective sheet including writing letters, synthetic enamal paint over a coat of primer complete all as specified and directed. |
| 17 | M& L for Excavation in UNHD Fire symbols Boards (1.2m x1.2m x 2.7m) post holes PCC 1:4:8 as in fdn, MS work in frame, 1mm thick plain black sheet fixed over frame, reflective sheet including writing letters, synthetic enamal paint over a coat of primer complete all as specified and directed. |
| 18 | Fire Point as per permanent zonal specifications based on dwg No CESZ/TD-1043/2011 |
| 19 | RCC M-30 design mix SWT 50000 Glns capacity as per permanent specification ref Drg No CELZ/WD/ST/22-04/2018 (sheet 1/2,2/2,3/3) |
| 20 | M&L for Polythene film ,black 125 micron laid in fool over sand cushioning for laying payment quality concrete complete all as specified and directed. |
| 21 | M &L for LLDPE septic tank exc designed to carry sewage and sullage water, excavation in any soil, PCC 1:4:8 in foundation vent shaft, connections etc complete all as specified and directed. |
| 22 | M&L for soakage well, exc including ordinary soil, fdn in PCC 1:3:6, wells of honey combed and soild in M-25 concrete, including intercepting chamber, screen chambers, brick work in CM, RCC cover slab in M-25 Grade/SFRC cover inter connecting pipes of RCC/DWC complete filled with brickbats of size 1.8Mtr Dia x3.00 Mtr effictive depth complete all as specified and directed. |
| 23 | Supply, erection and commissioning of Steel tubular swaged poles 11 mtr long complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 including excavation, returning filling, PCC complete all as specified and directed. |
| 24 | S&F Disc type Porcelain Insulator, vitreous brown , large size with overall dimension 90x140mm clearence of hole 25.5 mm ,working pressure 11000 volts all as complete all as specified and directed. by Engr-in-charge. |
| 25 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm complete all as specified and directed. |
| 26 | Supply, Installation, Commissioning and testing and testing of factory made, CPRI approved LT Panel of size 1.2m x 1.2m x 0.6mm, Indoor type made out of CRCA sheet 2mm thick, frame factory fabricated with front and back openable double door with locking arrangement with MS angle section 50x50x6mm support, duly powder coated painting having thickness not lless than 100 microns provided suitable gasket to make it dust and vermin proof , suitable for 3 phase 4 wire, 415 Volts, 50Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform complete all as directed suitable for and the following :-(a) Copper bus bar, 3 phase, 4 wire, AC supply system 50Hz mounted on epoxy based post insulators, including drilling hole for cable connection, rating of bus bar 630 Amps(b) Change over 400Amps, 4 pole 415 Volt.(c) MCCB 4 Pole, 415 Volt with thermal magnetic release (Manual dropout type) of capacity 400 Amps - 01 No.(d) MCCB 4 Pole, 415 Volt with thermal magnetic release (Manual drawout type) of capacity 400Amps - 01 No (O/G)(e) MCB 63 Amps, 415 Volts, 16 KA, thermal magnetic release - 02 No |
| 27 | (f) Indicator lamp LED type (RYB) - 01 Set (g) Digital type ammeter 3 phase with in built selectoe switch suitable for upto 100 Amp including CTs - 01 Set(h) Digital type Voltmeter 3 Phase with inbuilt selector switch suitable for upto 500Volt - 01 Set(j) All accessories prewired with appropriate size copper strip or wire thimbles etc(k) All as required including foundations as per manufacturers recommendation. |
| 28 | Supply and laying XLPE power cable of 1100 volt grade of size 300 Sqmm 3.5 core direct in ground including excavation , sand cushioning , protectiver covering and refilling the trench etc as required complete all as specified and directed. |
| 29 | Supplying and Making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs and other jointing materials for 3.5 core 185 Sqmm , XLPE aluminium conductor cable of 440 Volt grade as required complete all as specified and directed. |
| 30 | Supply and fixing LED Street light fixture, powder coated pressure die cast aluminium body with driver as per requirement with driver efficiency >85%, input voltage 140-270 Volt AC (System lumen efficacy >135 lm/Watt) of capacity 36 watt including 1.5 mtr long GI pipe, brackets, nuts and bolts complete all as specified and directed. |
| 31 | Supply and Fixing Sluice valves, flanged type of class 1.6 PN , of size 80 mm dia including rubber gasket for suitable size and nuts, bolts, washers complete all as specified and directed |
| 32 | Supply, laying and testing of ductile Iron pipe of 80mm dia, special Class 'K-7' including rubber gasket complete all as specified and directed by Engr-in-Charge |
| 33 | M&L for PCC Block masonary valve pit of size 1.2x1.2x1.6 cm (internal dimensions of chamber) built in CM 1:6 including 10mm thick plastering internally with cement mortar 1:6 and flush pointing externally as the work proceeds in same mortar complete with 5mm thick MS sheet cover with angle iron 40x40x6mm frame , handle locking arrangement and painting steel surfae ( cover inside and outside with frame) with two coats of synthetic enamel paint over a coat of red oxide primer including emebding angle in PCC complete all as specified and directed |
| 34 | Supply & installation of silent type Diesel Generating Set as per CPCB IV + or better norms along with having prime power rating of 380 KVA, 415 Volt at 1500 RPM , 0.8 lagging power factor at 415 Volt suitable for 501 Hz, 3 Phase system & for 0.85 Load factor including testing at factory and site with fuel, load for test other necessary arrangements complete as per CPWD specifications should contain drawing, test report OEM manual, Geo-Tag of manufacturing location, rating plate as per relevant IS code etc.. and consisting of the following:- |
| 35 | (A) Diesel Engine : Turbo Charged Diesel Engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP 462 (minimum) at 1500 RPM suitable for above output of alternator at 40 degree celsius, 50% RH & at 3150 above meter MSL, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with electronic governor, dry type air filter with service indicator , first filling of engine fuel (after commissioning) lubricating oil, coolant and other consumables complete with all the required accessories, the engine shall comply to thr latest CPCB norms (CPCB IV + or better) and conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. Note :- DG Set should be capable of giving output at 200 KVA at Tangtse. Engine BHP to be selected accordingly. |
| 36 | (B) Engine mounted instrument panel fitted with and having digital display for following:-(i) Start-Stop switch with key.(ii) Water Temperature indication.(iii) Lubrication Oil Pressure Indication.(iv) Lubrication Oil Temperature Indication.(v) Battery Charging Indication and Voltage Indication.(vi) RPM Indication.(vii) Over Speed Indication.(viii) Low lubrication Oil trip Indication.(ix) Engine running hours indication.(x) Fuel level. |
| 37 | (C) Alternator :- Syncronous alternator rated of 200 KVA, 415 Volts, 415 Volts at 1500 RPM, 3 Phase 50Hz, AC Supply with 0.8 lagging power factor at 40 degree C, 50% RH. The alternator shall be having screen protected drip proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour aftyer 12 hours continuous operation, self cooled, self excited and self- regulated through AVR conforming to IS 13364 (Part 20)/IS 4722/BS 2613 suitable for tropical conditions and with class-H insulation. |
| 38 | (D) Base frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. |
| 39 | (E) Fuel Tank :- Daily service of fuel tank of suitable litres capacity as per CPWD specifications, fabricated out of 3mm thick MS sheet complete all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia complete with valves, level indications & aceesories as required as per specifications. |
| 40 | (F) Exhaust System :- Dry exhaust manifold with hospital type exhaust silencer and catalytic converter. |
| 41 | (G) Starting System :- 12V/24V DC starting system comprising of starter motors, voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. |
| 42 | (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications. |
| 43 | (J) AMF Panel : Free standing floor mounted IP42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG Set complete with relays, timers set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Amp reactive power (KVARH), KVA (Phase & Total), KW & Provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and (Copper) cabling of suitable size upto 15 meter between AMF Panel , LT Panel and DG Set including connection interconnection etc.. as required, all complete band inter locking and communication/Ethernet/RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc.. as per approved by Engr-in-Charge and including the following:- |
| 44 | (i) Suitable numvers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/MCCB with electronic release for O/C & E/F and shunt trip.(ii) Auto/Manual/Test/Off selector switch.(iii) Protection for under and over voltage phase reversal (02 Nos Over voltage relay, 02 Nos reverse power relay and 02 Nos under voltage relay.(iv) 03 Sets of current transformers 15 P 10 accuracy for protection and 15VA class-I for metering.(v) Energy analyser unit to indicate current, Voltage (L-N & L-L), KW, KVA (Phase & Total ), Frequency, KWH,PF(vi) LED Indicating lamps for load on mains and load on set (vii) Fuse/MCB for instruments.(viii) Battery Charger complete with transformer/rectifier, DC voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.(ix) Main supply failure monitor(x) Supply failure timer.(xi) Restoration timer |
| 45 | (xii) Control unit with three impulse automatic engine start/stop and failure to start lockout.(xiii) Impulse counter with locking and reset facility.(xiv) ON/OFF/Control circuit switch with indicator(xv) Audio/Video annuciation for (a). High water temperature, (b). Low lubricating Oil Pressure, (c). Engine Over Speed, (d). Engine fails to start, ( e). Full mload/maximum load warning(xvi) Protectiobn for Over/Under frequency, loss of AC sensing, Over Current, Unbalancing Load with suitable number of relays and accessories.(xvii) Maintenance notification based on Engine Run Hour & due date.(xviii) Load management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel, interlocking providing signal to AMF Panel load status and AMF shall give command to DG Set to auto start/auto stop depending upon load status and requirement etcc. and operation shall be provided by the contractor including all control wiring. |
| 46 | (K). Civil Works :- All civil works including PCC plat form as per manufacture's design also 30 cm above the ground. The depth of the foundation and PCC as recommended by the manufacturer. |
| 47 | (L) Rubber Matting of LV grade 19mm thick of suitable size chequred type ISI marked to be laid in front of control panel should be provided. Please Enable Macros to View BoQ information |
| 48 | (L) Rubber Matting of LV grade 19mm thick of suitable size chequred type ISI marked to be laid in front of control panel should be provided. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 25, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Oct 26, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 22 daysOct 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysOct 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender