Tender For Repair/Maint Of Ceiling Fan, Exhaust Fan, Geyser, Wall Mounted Fan, Split And Window Ac, Water Cooler, Deep Freezer And Refrigerator Alongwith Connected Itesm At Cod Under Ge (I) Kanpur
Tender Value
36 Lakhs
Estimated cost
Bid Submission
29 Sep 2026
16 days left
EMD
72000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur Nagar → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Ceiling Fan, Exhaust Fan, Geyser, Wall Mounted Fan, Split And Window Ac, Water Cooler, Deep Freezer And Refrigerator Alongwith Connected Itesm At Cod Under Ge (I) Kanpur
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE(I) Kanpur Name of Work : REPAIR/MAINT OF CEILING FAN, EXHAUST FAN, GEYSER, WALL MOUNTED FAN, SPLIT AND WINDOW AC, WATER COOLER, DEEP FREEZER AND REFRIGERATOR ALONGWITH CONNECTED ITESM AT COD UNDER GE (I) KANPUR Contract No : GE(I)/KAN/T-85 OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Items/Works Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Repair, maint and making the continuity of electric supply after rectifying the defects of the ceiling fan, exhaust fan, wall fan, desert cooler, geyser, water cooler, refrigrator, ACs etc. including providing of small pieces of electrical wire of size 0.75 to 4 Sqmm twin/three core and length not exceding 1 mtrs and all types of screws, nuts, bolts & washers as required at site complete all as specified and directed. (Note :- (i) any other accessories found unserviceable shall be replaced & paid seprately under respective items of this Sch. (ii) Contractor will collect complaint slip on daily morning from MES complaint cell and deposit the same after rectifing the defact on next day morning (iii) Complaint slip book, registers as per sample will be provided by the contractor |
| 3 | Disconnecting electrically, taking down existing ceiling/exhasut fan any type and capacity with due care, dismantlin blades and removing for repair with all accessories complete all as specified and directed. |
| 4 | Assembling the fan any type with blades at site and hanging on ceiling /wall refixing after getting rapaired complete with all accessories complete all as specified and directed. |
| 5 | Strip opening of ceiling fan 230 volts any make /type/size for carrying out repair/greasing / oiling, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing complete all as specified and directed. Note :- 1. Repairs will be measured and paid separately under respective items. |
| 6 | Rewinding of ceiling fan motor 1200/1400 mm sweep any make/size with super enamelled copper winding wire with gauge including cutting of old burnt winding. Sleeve work varnishing with `B' class insulation varnish, greasing, connection with flexible wire of appropriate size two core copper wire upto connector block qty of copper winding wire complete all as specified and directed. |
| 7 | S&F in repair fan capacitor AC 440 volts 4 mfd 50HZ complete all as specified and directed. |
| 8 | All as per item No 6 above but 2.5 mfd and complete all as specified and directed. |
| 9 | All as per item No 6 above but 3.15 mfd and complete all as specified and directed. |
| 10 | S&F in repair of gun metal bush suitable for any size / model / type of fans complete all as specified & directed. |
| 11 | S&F in repair alignment grinding to shaft, remetalling & finishing all as required complete all as specified and directed. |
| 12 | S&F in repair ceiling fan shaft of standard size including taking out old shaft complete all as specified and directed. |
| 13 | Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically complete all as specified and directed. |
| 14 | Strip opening of exhaust fan/air circulator/table fan/Pedestal/wall fan any size / make / sweep for carry out repair/greasing, oiling work, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing after carrying out the repair complete all as specified and directed. |
| 15 | Rewinding of exhaust fan/ air circulator fan/ table fan/pedestal/wall mounted fan motor any size, from 225 to 450 mm sweep with supper enamelled copper wire as required including necessary cutting of old burnt winding wire, cleaning of slots, greasing and provision of necessary threading/sleeve work and taking out connection in lead with PVC copper wire of appropriate size upto connector block complete and all as specified. |
| 16 | S&F in repair of ball bearing any No suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed. |
| 17 | S&F in repair of ball bearing for exhaust fan/pedestal fan/air circulator/table/wall fan upto 450mm sweep complete all as specified and directed. |
| 18 | Cleaning thoroughly ceiling fans 48\\"/56\\" (1200mm / 1400mm) sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified and directed. |
| 19 | Cleaning thoroughly exhaust/wall/podestal fan 256 mm to 450 mm sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified and directed. |
| 20 | S&F in repair of fan blade set steel heavy duty suitable for exhaust/ pedestal/air circulator fan 250 to 450 mm sweep, complete all as specified and directed. |
| 21 | S&F in repair of fan blade set plastic suitable for exhaust/ pedestal/air circulator fan 250 to 450 mm sweep, complete all as specified and directed. |
| 22 | S&F in replacement of fan blade set steel 1200/1400mm sweep suitable for ceiling fan complete all as specified and directed. |
| 23 | S&F in replacement of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade duly threaded/pin complete all as specified and directed. |
| 24 | All as per item No 22 above but of size 1 Mtrs long and complete all as specified and directed. |
| 25 | All as per item No 22 above but of size 1.5 Mtrs long and complete all as specified and directed. |
| 26 | All as per item No 22 above but of size 2 Mtrs long and complete all as specified and directed. |
| 27 | All as per item No 22 above but of size 3 Mtrs long and complete all as specified and directed. |
| 28 | Disconnecting & taking down upto 1400m sweep ceiling fan and deposited to MES store yard and Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 3742019), THD less than 10%, electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete all as specified and directed.Note : (a) Make, Model & Colour of fan as approved by GE. (b) Writing MES No. in black synthetic enamel paint by the contractor.(c) T & P will be provided by the contractor for reaching any height of the ceiling. |
| 29 | Supply and fixing lower and upper canopy of fans of ceiling fans of suitable size required at site complete all as specified and directed. |
| 30 | S&F in repair for 40 / 50 mm bore galvanised iron tubing medium grade fixed to walls for hanging the fan complete all as specified and directed. |
| 31 | S&F of hook for hanging of fan on ceiling of suitable shape of mild steel flat iron with suitable size nuts, bolts & washers complete all as specified and directed. |
| 32 | M&L for providing PVC rounded 3 core 0.75 sqmm copper cable and making necessary connection complete all as specified and directed. |
| 33 | All as per item No 31 above but copper cable of size 1.5 Sqmm complete all as specified and directed. |
| 34 | Supply and fixing ceiling fan complete with blades, down rod, electronic regulator accessories ,230 V, 1200 mm sweep. Min air delivery 210 cfm with service value 6.00 BEE. 5 star rated with brushless direct current motor(BLDC) without remote control complete all as specified and directed. |
| 35 | Supply and fixing ceiling fan complete with blades, down rod, electronic regulator accessories ,230 V, 1400 mm sweep. Min air delivery 245 cfm with service value 6.00 BEE. 5 star rated with brushless direct current motor(BLDC) without remote control complete all as specified and directed. |
| 36 | Supply and fixing of exhaust fan, steel body ac single phse 230 of size 300 mm sweep with bldeand frame and louvers complete all as specified and directed. |
| 37 | M&L in repair for taking down/out desert cooler from exsting place and removing the old paint from the body of desert cooler and applying paint external body, fan and pump with a coat of synthetic enamel grey paint , internal body with a coat of synthetic enamel black paint with brush painting at site after proper dusting cleaning and scraping old painted surface and refixing on same/other location after painting complete all as specified and directed. |
| 38 | M&L in repair of side panels of desert cooler made out of 22 SWG mild steel sheet of size not more than 0.70x0.80 mtr to match with existing cooler complete with jalli, wood wool pad , fastners painting with two coat of synthetic enamel paint over a coat of primer etc complete all as specified and directed. |
| 39 | M&L inrepair of desert cooler water tank made out of 19 SWG mild steel sheet of size not more than 0.80x0.80x0.20 mtr (approx) to match with existing cooler including front side panel opening complete with louvers, provision for selector switch, indicator lamp etc and top cover plate made of 22 SWG mild steel along with vertical angle support of suitable height and two coat of synthetic enamel paint over a coat of primer etc complete all as specified and directed. |
| 40 | Supply and fixing in repair of water lifting pump submersible type 220 -240 Volts 50 HZ complete all as specified and directed. |
| 41 | Supply & fixing in repair of kit fan motor of desert cooler 230 volts complete with blades, fixing legs, nuts, bolts, washers etc complete all as specified and directed. |
| 42 | S&F in replacement of ready made wood wool pad size as required at site of 15 mm thickness, made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as specified & directed. |
| 43 | M&L for disconnecting, dismantling, refixing and rewinding of kit fan motor upto 450 mm sweep of desert coolers 230 volts AC 50 C/S with super enamelled copper conductor wire of existing gauge as original including replacement of bush -02 Nos shaft -01 No ring-01 No & clamp-04 Nos complete all as specified & directed |
| 44 | S&F in repair of desert cooler stand using angle iron (40 x 40 x 6 mm) making square type platform of min size 800 x 800mm and fixing through two angle iron piece for horizontal support and two angle iron piece for 45 degree angle vertical support into the walls of any type / height as required on site by means of required nuts, bolts, fastners, welding work etc to form a platform suitable for fixing the desert cooler of any size & type compete all as specified and directed.Note: Angle iron should be painted with a coat of red oxide primer and two coat of synthetic enamel paint. Minimum 20 cm length of the angle iron should be inserted into the wall and fixing the same through required PCC work. Cutting chases in walls required for fixing the angle iron support shall be finished with cement mortar 1:4 and surface shall be matched with existing surface by using putty, plaster of paris etc. and applying finishing coat of existing treatment shall be deemed to be included in the unit rate quoted by the contractor. |
| 45 | M&L in repair for dismentling, taking out old u/s clamp and fixing with new clamp for kit fan motor of desert cooler as per site requirement with nuts & washers complete all as specified and directed. |
| 46 | Dismantling old PVC Water distributor four way and refixing with new complete all as specified and directed. |
| 47 | S&F in repair of existing UNSV desert cooler blade and fix in the desert cooler complete all as specified and directed. |
| 48 | M&L for disconnecting, dismantling old u/s wiring of desert cooler and replacement with new wiring of selector switches and indication lamps and other as required at site with 1.5 Sqmm single core wires complete all as specified and directed. |
| 49 | S&F of desert cooler having tank capacity 60-80 litre, fitted with heavy duty fan/ blower, copper wound motor (single phase , 230 v, 50 HZ) high efficiency honeycomb cooling pads, water circulator pump , float valve arrangement, multi speed control, air deflection louvers and all internal wiring including connection with existing supply, providing suitable stand/ support complete in all respects as required at site. |
| 50 | Disconnecting, dismantling and taking out old u/s storage type water heater geyser of cap 25/35 Ltrs from wall for repair at site complete all as specified and directed. |
| 51 | Fixing only storage type water heater geyser on wall after repair and replacement of old unserviceable with gutties/anchor bolts or nuts & bolts and fixing the same in existing /other location complete all as specified and directed. |
| 52 | M&L for spray painting of outside surfaces of geyser with two coats of white synthetic enamel paint after preparing surface with and including writing MES No. complete all as specified and directed. |
| 53 | M&L for opening the geyser and replacement of glass wool for insulation of geyser of 25 to 50 ltrs capacity of any make / type complete all as specified and directed. |
| 54 | S&F in repair of chromium plated flexible copper connection with two brass adopter as per existing sample suitable for carrying hot / cold water, fixed one end at geyser inlet and other to outlet water supply point complete all as specified and directed. |
| 55 | S&F in repair of PVC flexible connection with two brass adopter as per existing sample suitable for carrying hot / cold water, fixed one end at geyser inlet and other to outlet water supply point complete all as specified and directed. |
| 56 | M&L for disconnecting, dismantling old u/s thermostat switch of geyser 25 to 50 ltrs capacity and replaced with new with temperature range adjustable from 25 to 90 degree centigrade, superior quality 20 Amps rating, 220 Volts AC supply complete all as specified and directed. |
| 57 | M&L for disconnecting, dismantling old u/s heating element of cap 2 kW and replaced with new and testing on completion complete all as specified and directed. |
| 58 | All as per item No 56 above but heating element of size 1.5 kW complete all as specified and directed. |
| 59 | M&L for dismantling old u/s syphon assembly of geyser 25 to 50 ltrs ltr capacity and replaced with new stainless steel syphon complete all as specified and directed. |
| 60 | M&L for dismantling old u/s inner tank of geyser and replaced with new stainless steel inner tank suitable for 25 to 50 ltrs ltrs capacity geysers of 22 SWG and hydraulically tested at 22.5 PSI pressure maintained at 90 degree centigrade as approved complete all as specified and directed. |
| 61 | M&L for single pole and neutral enclousere with a top pin, earth plug and socket copmlete with one MCB 25 Amps, 240 Volts complete all as specified and directed. |
| 62 | S&F in repair of pressure release valve with inlet coupling of superior quality as approved complete all as specified and directed. |
| 63 | S&F in repair of plug top 15 Amps complete all as specified and directed. |
| 64 | S&F in repair of indicator LED bulb square / round type complete with necessary connection wire of red & green colour complete all as specified and directed. |
| 65 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc complete all as specified and directed. |
| 66 | Disconnecting electrically, taking down, dismantling, opening the cover of AC and taking out and servicing of window type air conditioner cap 1.5/ 2 Ton capacity including cleaning / removing all dust / mud, oil and other foreign particle from grill, filter, condenser fin, evaporator fin including opening cover, peripheries and whole body using detergent solution or chemical solution and refitting all parts and fixing the same in existing/other location complete all as specified and directed. |
| 67 | Disconnecting, dismantling, opening the cover of AC and removing unserviceable / defective parts from the window AC of 1.5 / 2 Ton capacity including necessary welding with existing refrigerant pipe, charging refrigerant gas and testing complete all as specified and directed.Note: (i) All spares such as sealed compressor, fan motor, relay, capacitor, over load relay and refrigerant gas shall be measured and paid separately if required under respective item of Schedule ‘A’.(ii) If any item required to make equipment functional like capillary copper pipe etc is deemed to be included in unit quoted rate.(iii) Old unserviceable hermetic sealed unit and other materials obtained from the window type AC will be accounted under Schedule of credit and same shall become the property of the Contractor |
| 68 | S&F in repair of cooling coil of window type AC any cap up to 2 ton complete all as specified and directed. |
| 69 | S&F in repair of front grill of window AC suitable for 1.5/2 ton cap complete all as specified and directed. |
| 70 | S&F in repair of rotary type sealed compressor of window AC 1.5/2 Ton cap complete all as specified and directed. |
| 71 | S&F in repair of Air blower moter suitable for window/split type AC of 1.5/2 Ton capacity single phase complete all as specified and directed. |
| 72 | S&F in repair of starting capacitor suitable for window/split AC of rating 45 - 100 Mfd complete all as specified and directed. |
| 73 | S&F in repair of starting relay suitable for Window/split AC of capacity 1.5 / 2.0 Ton complete all as specified and directed. |
| 74 | S&F in repair of rotary /push type selector switch suitable for window type AC of capacity 1.5 / 2.0 Ton complete all as specified and directed. |
| 75 | S&F in repair of thermostat switch for window/split type AC of 1.5 /2.0 Ton capacity complete all as specified and directed. |
| 76 | S&F in repair of condenser fan blade suitable for window/split type AC of any make & capacity all as spfd and direceted. |
| 77 | M&L for minor denting work to window type air conditioners of 1.5 / 2 Ton capacity including applying spary painting with a coat of synthetic enamel paint of requried shade complete all as specified and directed. |
| 78 | Disconnecting electrically and opening the cover of split AC 1.5/2 ton cap inner/outer unit and servicing incluiding cleaning / removing all dust / mud, oil and other foreign particle from grill, screen filter at indoor unit and condenser fin, evaporator fin at outdoor unit using detergent solution or chemical solution complete including servicing, oiling, greasing complete air conditioner and checking of electrical connection and testing complete all as specified and directed. |
| 79 | Disconnecting, dismantling, opening the cover of AC and removing unserviceable / defective parts from the Split type AC of 1.5 / 2 Ton capacity and fixing only new spares as per model / capacity including necessary welding with existing refrigerant pipe, charging refrigerant gas and testing complete all as specified and directed.Note: (i) All spares such as sealed compressor, fan motor, relay, capacitor, over load relay and refrigerant gas shall be measured and paid separately under respective item of Schedule ‘A’.(ii) If any item required to make equipment functional like capillary copper pipe etc is deemed to be included in unit quoted rate. |
| 80 | S&F in repair of sealed compressor, rotary type, of any make suitable for split type AC of 1.5/2 Ton capacity complete all as specified and directed. |
| 81 | S&F in repair of Inlet / outlet control valve for outdoor / indoor unit of suitable size, of any make & any type complete all as specified and directed. |
| 82 | S&F in repair of discharge grill of outdoor unit of any size and type for split AC’s complete all as specified and directed. |
| 83 | Supply and fixing in repair of defective remote control hand set with \\"AAA\\" batteries for window/split type AC's, of any model / make complete all as specified and directed. |
| 84 | Supply and fixing in repair of display indication on LCD screen assembly mounted on indoor unit (cooling unit) for split type AC’s, of any model / make complete all as specified and directed. |
| 85 | Supply and fixing of micron filter suitable for window / split type AC of 1.5 Ton capacity complete all as specified and directed. |
| 86 | Supply and fixing of copper tube as per existing and site requirement complete all as specified and directed. |
| 87 | Supply and fixing of condenser / cooling coil for air conditioner of suitable size complete all as specified and directed. |
| 88 | Disconnecting, dismantling and taking out indoor and outdoor unit of split type AC with cooling tubing and other accessories with carefully and deposited to MES store yard complete with outer/inner unit, copper tubing, drain pipe and remort complete all as specified and directed. |
| 89 | M&L for fixing/installation of split AC inner/outer or both unit as received from item No 87 with all accessories and making all coonection of copper tubing/drain and electrically and testing on completion complete all as specified and directed. Note : Refrigrant and other connecting items i.e copper tube/ drain pipe will be measured and paid seperately under respective item if required. |
| 90 | Supply and fixing in repair of deoxidized annealed copper tube of including brazing etc. complete all as specified and directed. |
| 91 | Supply and fixing in repair of foamed polythene insulating pipe of 18 mm internal dia and 8 mm wall thickness complete all as specified and directed. |
| 92 | S&F in repair of Main control circuit (PCB) for window/split type AC's, of any model / make complete all as specified and directed. |
| 93 | S&F in replacement of Main control circuit (PCB) for inverter type split type AC's, (indoor & out door ) of existing model / make complete all as specified and directed. |
| 94 | S&F in replacement of Sensor for window/split type AC's, of any model / make complete all as specified and directed. |
| 95 | S&F in repair of PVC flexible drain pipe 15mm to 25mm dia complete all as specified and directed. |
| 96 | M&L for flushing, pressurising the system, leakage testing, vacuumization and charging with refrigerant R -22 / R-134a/R-410 (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for window / split type air conditioner 1.5 / 2.0 TR cap at site / contractor's workshop including any welding / repair work reqd at site complete all as specified and directed. |
| 97 | Supply & fix in concealed or fixed on wall of rigid non-metallic PVC conduit medium grade of size 20/25 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends for drain of AC complete all as specified and directed. |
| 98 | Supply only refrigerant R-22/R134a/R410 environment friendly refrigerants as per type of ACs for any type of gas filling the AC/Refrigeritor/water cooler/deep freezer etc complete one time for topping up or making full qty including plugging the leakage/ welding / repair work reqd at site complete all as specified and directed.Note : Refrigerant gas shall be supplied and paid separately under item No 95 herein after |
| 99 | S&F in replacment of split AC indoor undit complete of cap 1.5 ton 3 star rating built with copper evaporator including connecting with existing outdoor unit with electrically, gas pipes, electronic circuits and other accessories complete all as specified and directed. |
| 100 | S&F in replacment of split AC outdoor undit complete of cap 1.5 ton 3 star rating built with copper evaporator including connecting with existing indoor unit with electrically, gas pipes, electronic circuits and other accessories complete all as specified and directed. |
| 101 | Disconnecting, dismantling old u/s compressor from refrigrator and replaced with new for the refrigerator of capacity 165 to 310 Ltrs including necessary welding with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed. |
| 102 | Supply and fixing in repair of Starting relay suitable for refrigerator of any make and capacity complete all as specified and directed. |
| 103 | Supply and fixing in repair of Thermostat suitable for refrigerator of any make and capacity complete all as specified and directed. |
| 104 | Supply and fixing in repair of PVC freezer door suitable for any size and capacity of the refrigerator complete all as specified and directed. |
| 105 | Supply and fixing in repair of Magnetic rubber door gasket suitable for any size and capacity of the refrigerator complete all as specified and directed. |
| 106 | Supply and fixing in repair of Copper liquid line filter two way / one way of refrigrator any type/capacity complete all as specified and directed. |
| 107 | Supply and fixing in repair of Over load protector of size 1/6 HP to 1/8 HP of refrigrator any type complete all as specified and directed. |
| 108 | Supply and fixing in repair of Capillary tube as per site requirement of refrigrator/water cooler any type complete all as specified and directed. |
| 109 | Supply and fixing in repair of Bulb of refrigrator any type as per site requirement complete all as specified and directed. |
| 110 | Supply and fixing in repair of Ice tray twist type PVC of refrigrator any type complete all as specified and directed. |
| 111 | Supply and fixing in replacement of Freezer with door of any make, type of rfrigerator of capacity 320 ltrs complete all as specified and directed. |
| 112 | Supply and fixing in repair of Condenser cooling coil suitable for refrigerator capacity min 165 ltr to maximum 310 ltrs complete all as specified and directed. |
| 113 | Supply and fixing in repair of Vegetable basket suitable for refrigerator as per site requirement complete all as specified and directed. |
| 114 | Supply and fixing in repair of Partition jalli /glass shelf suitable for refrigerator as per site requirement complete all as specified and directed. |
| 115 | Disconnecting, dismantling and taking out old u/s voltage stabilizer of cap 2 to 5 kVA and refixing the same in same/other location after repair incl all minor parts i.e wire, nut, bolt and washers etc complete all as specified and directed. Note : Spare parts will be measured and paid seperately under respactive items. |
| 116 | Supply and fixing in repair of Main relay of voltage stabilizer 3 to 5 kVA complete all as specified and directed. |
| 117 | Supply and fixing in repair of Main control circuit (PCB) of voltage stabilizer 3 to 5 kVA complete all as specified and directed. |
| 118 | Supply and fixing in repair of replacement of sensor transformer of voltage stabilizer 3 to 5 kVA complete all as specified and directed. |
| 119 | Supply and fixing in repair of voltmeter of voltage stabilizer 3 to 5 kVA complete all as specified and directed. |
| 120 | Supply and fixing in repair of Time delay relay, 2-3 minute over / low voltage 180 Volts AC and high voltage 260 Volts AC of voltage stabilizer 1 to 5 kVA complete all as specified and directed. |
| 121 | Taking out old burnt winding of transformer and re-winding the same with super enameled copper winding wire (existing size) for 3 to 5 kVA voltage stabilizers including all necessary insulating material and testing complete all as specified and directed. |
| 122 | M&L repair for painting of voltage stabilizers with a coat of synthetic enamel paint of existing shade after proper cleaning and scraping out old painted surfaces and writing GE (I) Kanpur on voltage stabilizers in block letters with white synthetic enameled paint complete all as specified and directed. |
| 123 | Taking out water cooler of any make and type of capacity 40 / 80 / 150 ltrs from position and cleaning/serviceing the complete condenser coil and storage tank with chemical base solution and soda water including servicing, oiling of air blower motor, checking of electrical & water supply connection incl and re-fixing the same on its existing position after testing complete all as specified and directed. |
| 124 | Disconnecting, dismantling and taking out defective water cooler of any make and type of capacity 40 / 80 / 150 ltrs for repair complete all as specified and directed. |
| 125 | M&L repair for fixing/installation of water cooler any type of cap 40/ 80/ 150 ltrs and making all electrical/water connection and testing complete all as specified and directed. |
| 126 | S&F repair in replacement of sealed compressor suitable for water cooler of capacity up to 40 / 80/ 150 Ltrs complete all as specified and directed. |
| 127 | S&F repair in replacement of Starting capacitor 40-60 Mfd / 60-80 Mfd / 80-100 Mfd for water cooler complete all as specified and directed. |
| 128 | S&F repair in replacement of Running capacitor 10-30 Mfd for water coller/ window ac/ split ac/refrigerator complete all as specified and directed. |
| 129 | S&F repair in replacement of Thermostat suitable for water cooler of capacity 40 / 80 / 150 ltrs complete all as specified and directed. |
| 130 | S&F repair in replacement of Starting relay of water cooler as per compressor requirement complete all as specified and directed. |
| 131 | S&F repair in replacement of Blower motor of water cooler with fan blade of capacity 1/10 to 1/35 HP as per site requirement complete all as specified and directed. |
| 132 | S&F repair in replacement of over load protector of water cooler suitable for water coolers complete all as specified and directed. |
| 133 | S&F in repair of PVC flexible pipe transparent 15 / 20 mm dia for water cooler complete all as specified and directed. |
| 134 | S&F in replacement of Brass chromium plated Push cock heavy duty universal type, suitable for water cooler of capacity up to 150 ltrs complete all as specified and directed. |
| 135 | S&F in repair of PVC float valve 15 / 20 mm dia with rod & ball for water cooler complete all as specified and directed. |
| 136 | S&F in repair of Liquid line filter one way / two way for water cooler complete all as specified and directed. |
| 137 | Supply and fixing in repair of waste washing tray including PVC pipe connection of existing shape & size for water cooler as required at site complete all as specified and directed. |
| 138 | S&F in repair of condenser coil with copper tube and aluminium fins for water coolers suitable for up to 40 / 80/ 150 Ltrs capacity of any make and type complete all as specified and directed. |
| 139 | M&L repair for cutting out worn bottom and sheet base frame including mild steel legs from water coolers of any make and capacity and fixing the same with new plain galvanised iron sheet 16 SWG of existing size and new angle iron base frame and legs of existing size with and including necessary gas welding and providing nuts / bolts etc complete all as specified and directed. |
| 140 | M&L repair for minor denting work and applying a coat of spray painting to water cooler with synthetic enamel paint after proper scraping of old rusted painted surface complete all as specified and directed. |
| 141 | M&L repair for replacement of defective sealed compressor unit of 320 / 400 ltr cap deep freezer. The rates quoted by the contractor shall be inclusive of all charges like transportation fitting etc complete with necessary guarantee period including checking and rectification of any leakage in system and make it functional to entire satisfaction of EIC incl oiling, greasing, gas charging and testing complete all as specified and directed.Note : Refrigerant gas shall be supplied and paid separately under item No 97 herein after. |
| 142 | M&L repair for finding out leakage with the pressure testing of the condensor / cooling unit / compressor of deep freezer 320 / 400 Ltr cap including dismantling the same for recharging and stop leakage by brizing / soldering including charging the R-134A gas (or reqd type) to required level and testing the deep freezer for the entire satisfaction of EIC.Note : Refrigerant gas shall be supplied and paid separately under item No 97 herein after |
| 143 | M&L for Writing SM / MES No. of Summer cooling appliances including Water coolers, desert coolers, refrigerators and Air Conditioners with synthetic enamel paint of Make Asian paints Ltd. Or Stickers equivalent of approved colour complete all as specified and directed. |
| 144 | Supply & Fixing in replecement air ventilator iron body/plastic body 200/250 mm sweep complete with fittings & connections to wall complete all as specified and directed. |
| 145 | M&L repair for water leakage from indoor unit any type & any make, height upto 15 ft complete all as specified and directed. |
| 146 | S&F in replacement of PCB for BLDC fan any type and size complete all as specified and directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysOct 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender