Tender For Special Repair To Building No Et-57 (Ors Living) At Darranga And Provn Of Dg Set 10 Kva At Tamulpur Under Ge Rangia
Tender Overview
Project Description
Tender For Special Repair To Building No Et-57 (Ors Living) At Darranga And Provn Of Dg Set 10 Kva At Tamulpur Under Ge Rangia
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-Sep-2026 | Schedule of Credit | Other | 28-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling asbestos cement ( Corrugated, Semi corrugated etc.) sheets in roof covering complete all as specified and as directed. |
| 2 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated / semi-corrugated (Trapezoidal) steel sheet 0.50 mm thick of a colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws alongwith washers etc complete all as specified and as directed by the Engg-in-charge. |
| 3 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of a colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks etc complete all as specified and directed. |
| 4 | M&L for Brickwork with subclass B brick straight and curved on plan to exc 6 m mean radius built in 1:6 cement mortar, incl demolition of brick work, built in cement mortar, complete all as specified and directed. |
| 5 | M&L for brick work with sub-class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4, incl demolition of brick work, built in cement mortar, complete all as specified and directed. |
| 6 | S&F in repair, exposed GI powder coated snap grid frame work for false ceiling of grid of size 600x600 mm comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 24x30x0.70mm with 2mm dia GI wire as suspender and including 4mm thick E-Board classic (decorative type) including fixing arrangement from roof truss of any type, complete all as specified and directed. |
| 7 | M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm and 5mm thick) finishing the surface fair and even without using extra cement to complete all as specified and as directed. |
| 8 | M&L for rendering 10 mm thick on other than fair faces of brick work or other side of lathing in cement mortar 1:6, surface finished fair and even without using extra cement complete all as specified and directed. |
| 9 | M&L for preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls, complete all as per specified and as directed. |
| 10 | M&L for applying two coats of oil bound distemper over a coat of priming paint applied over 1.5 mm thick wall care putty (in two layer) finished even and smooth on wall, complete all as specified and directed. |
| 11 | M&L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) using formwork if necessary in flooring/hard standing/pavings/plinth protections, incl demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (incl formwork where necessary) complete all as specified and directed. |
| 12 | M&L for RCC 1:2:4 type B1 (20 mm graded stone aggregate) nominal mix in beams, cantilevers, bressummers, lintels/chajjas, complete including demolition of old RCC complete all as specified and directed. |
| 13 | Use and waste of formwork to sides and soffits of roof beams, lintels/chajjas etc rough finished surfaces complete all as specified and directed. |
| 14 | M&L mild steel TMT bars 8 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. |
| 15 | M&L mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality confirming to Fe-410-S or Fe-410-O complete all as specified and directed. |
| 16 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 17 | M&L for Steel work in tubular trusses/posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979, complete all as specified and as directed by the Engg-in-charge. |
| 18 | M&L for Preparation of new or previously untreated or old steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of black japan paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 19 | Taking down chowkhats with shutters but not exceeding 1.5 Sqm each (without taking of shutters from the frame) complete all as specified and directed. |
| 20 | Taking down chowkhats with shutters but not exceeding 1.5 Sqm each but not exceeding 4 Sqm (without taking of shutters from the frame) complete all as specified and directed. |
| 21 | S&F Pressed steel double door frame of size 60 mm x 125 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, as specified, supplied & fixing in opening as per specification and drawing including filling of PCC (1:3:6) in 12.5 mm aggregates complete all as specified and as directed. |
| 22 | S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, and also one face is covered with decorative face veneer with lipping/frame to match, complete all as specified and as directed. |
| 23 | S&F 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. but divided into squares, with plain, chamfered or rounded, (rebated sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of Shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and as directed. |
| 24 | M&L for Preparation of newly untreated wood or wood base surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying two coats of Synthetic Enamel paint over a coat of zinc chromate primer complete all as specified and directed. |
| 25 | S&F 125 mm long extruded Aluminium alloy anodised Butt hinges with galvanized mild steel hinges complete all as specified and directed. |
| 26 | S&F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 27 | S&F 200 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 28 | S&F 300 mm aluminum alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 29 | S&F steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 30 | S&F steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified but without glazing bars complete all as specified and directed. |
| 31 | S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe. 290.Gde-E-165 complete all as specified and as directed. |
| 32 | M&L steel ventilators with top hung shutter including hinges, steel peg stay complete all as specified and directed. |
| 33 | S&F Stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.4 mm and fixed with 5mm thick PVC sheet fillet of width 35mm / stainless steel wire staples complete all as specified and as directed. |
| 34 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.50 Sqm in each pans complete all as specified and directed. |
| 35 | M&L for Chequered Cement Concrete Tiles 300x300x25mm thick pre printed colour or glossy finished tiles, Set and jointed in neat cement slurry with grey cement and pigment over and including screed bed 15mm thick in cement mortar 1:6 as in path, completed all as specified and directed. |
| 36 | S&F Vitrified ceramic tiles 10 mm thick of dark shade (Square/rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match with the shades of tiles including 20 mm thick screed bed or bedding layers in CM 1:6, complete all as per specified and directed. |
| 37 | All as per item No 36 but as in skirting complete all as specified and directed. |
| 38 | M&L 25 mm thick Cement concrete type C2, 1:2:4 (using 20 mm graded stone aggregate) in base of flooring complete all as specified and directed. |
| 39 | M&L 25mm dia mild steel powder coated drapery rod cut to length required without joint in between and including Mild steel powder coated fancy type brackets and fixed at openings including taking down existing old one complete all as specified and directed. |
| 40 | S&F in repair 250mm, ordinary mild steel rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 41 | S&F 5mm thick rubber beading strips of entrance doors having width exc 3cm and not exc 5cm to arrest entry of insects including taking down existing one complete all as specified and directed. |
| 42 | Taking down carefully aluminium/copper point wiring (light fan, socket or power, call bell point) complete incl fittings and fixtures such as switches, sockets, light fittings, ceiling rose, pendants, lamp holders, shade fittings and fixtures etc; separating serviceable fittings for reuse in the same work and removing unserviceable fittings and fixtures with wiring cable, battens, wooden boards etc from site and making good disturbed surfaces of walls, floors, ceiling etc all complete all as specified and as directed by Engineer-in-charge. |
| 43 | Taking down carefully unserviceable main switches and DB's incl wooden bds and removing from site incl making good disturbed surfaces of walls all complete. |
| 44 | Taking down and refixing old ceiling fans and to be kept safely in store and refixing the same after proper cleaning to the existing location along with suitable fan hook/hanging rod and testing complete all as specified and as directed. |
| 45 | M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and including PVC concealed (wall only) conduit and conduit accessories and fittings like bends, elbow, crosses, etc. with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/fan/exhaust fan/bell point controlled by one 1-way switch/bell push, complete all as per specified and as directed by Engineer-in-Charge. |
| 46 | All as per Item No. 45 here-in-above, but for One 3 pin socket outlet, 5 Amps, independent board, complete all as specified and as directed by Engineer-in-charge. |
| 47 | All as per Item No. 45 here-in-above, but for One 3 pin socket outlet, 5 Amps on the same board, complete all as specified and as directed by Engineer-in-charge. |
| 48 | All as per Item No. 45 here-in-above, but for One 3/5 pin socket outlet, 15 Amps, independent board, with cables 4 sq. mm size, complete all as specified and as directed by Engineer-in-charge. |
| 49 | S&F Modular Switch, One Module, 1-way, 20 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed. |
| 50 | S&F Modular Socket, 2/3 Pin, combined, two Module, 20 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed. |
| 51 | S&F Modular Socket, 3 Pin, combined, two Module, 10 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed. |
| 52 | S&F Modular Switch, One Module, 1-way, 10 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed. |
| 53 | S&F modular cover plate (white) with frame, 3-module, complete all as specified and as directed by Engineer-in-charge. |
| 54 | S&F of ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge. |
| 55 | S&F Modular stepped type electronic fan regulator, two module, 240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 56 | S&F surface and wall mounted LED tube light fitting 1x 20W, (4 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative box type with and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge. |
| 57 | S&F Energy saving new generation environmental friendly long life versatile pressure die cast aluminium housing and heat resistant, IP 66 street light fitting luminaire with high power LEDs as light source and heat resistant, 35 watts with pre wired and lens embedded PC cover having Top Opening separate driver compartment, with impact and corrosion resistant including thermal management in multiple optics and necessary mounting arrangements/fixing bracket, complete all as specified and as directed by Engineer-in-charge. |
| 58 | S&F of brackets for building security light made out of 25mm GI tubing medium grade 0.60 mtr long bend to required shape as in bracket for building security light fittings, including drilling hole in pipe for fixing with nut , bolt/screw in building wall complete all as specified and as directed. |
| 59 | S&F of Sheet Metal Enclosure MCB DB SPN, 8 way 240 volt, with suitable amp rated Bus-bar, double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge. |
| 60 | S&F in-repair of MCB Triple Pole & Neutral (TPN), 'C' Curve, 63 Amps, 415 Volt for fixing on MCB DB's, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge. |
| 61 | S&F MCB Single Pole & Neutral (SPN), 'C' Curve, 32 Amps, 240 Volt for fixing on MCB DB's, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge. |
| 62 | S&F MCB Single Pole (SP), 'C' Curve, 6-32 Amps, 240 Volt for fixing on MCB DB's, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge. |
| 63 | M&L sub main wiring two run of size 06 Sqmm PVC insulated electric power cable(heavy duty) 1100 Volt Grade with stranded copper conductor with 06.0 Sqmm PVC insulated copper conductor earth wire in PVC Conduit of suitable size (two run of 06 Sqmm cable and one of 6.00 Sqmm wire and one run of PVC conduit/Casing Caping will be measured as one unit) including dismantling of existing unserviceable submain wiring complete all as specified and as directed. |
| 64 | All as per item No 63 above but using two run 4.0 Sqmm multistranded copper conductor single core cable with one run 4.00 sqmm multistranded copper conductor single core cable as earth wire complete all as specified and as directed. |
| 65 | Supply, laying, jointing and testing LT underground electric power cable crossed linked XLPE insulated, two or more core galvanized steel strip or wire armored / PVC insulated armored cable heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 16 sqmm 2 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts or passing through pipes etc fixing and connecting accessories such as Aluminium cable lugs, cable glands, nut, bolts, washers etc complete all as specified and as directed.Note: Earth work, excavation, GI pipe, sand cushioning and protection brick shall be measured and paid separately under appropriate items. |
| 66 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft / loose soil complete all as specified and as directed. |
| 67 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250 mm in soft/loose soil, complete all as specified and as directed. |
| 68 | Removing excavated materials (soils) not exc. 50.00 M and deposited where directed at a level not exc. 1.50 M above the starting point in soil, complete all as specified and as directed. |
| 69 | M&L Sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreading thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. |
| 70 | Supply and laying sub class B bricks of size 230x125x73mm (+/- 10% tolerance limit) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed. |
| 71 | Excavation and cutting/boring in PCC/bitumen road for laying of underground cable of any size including making good and finishing to existing complete all as specified and as directed. |
| 72 | Supplying and fixing Galvanised mild steel pipe/tubing, light grade complete with all fittings of 40 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washers as in cable protection complete all as specified and as directed. |
| 73 | M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel, protected by GI pipe 15 mm bore (light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excavation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down old unserviceable one, complete all as specified & testing on completion. NOTE: (i) Item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) Item rates includes the cost of 7.5 mtr GI earth wire. Please Enable Macros to View BoQ information |
| 74 | M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel, protected by GI pipe 15 mm bore (light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excavation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down old unserviceable one, complete all as specified & testing on completion. NOTE: (i) Item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) Item rates includes the cost of 7.5 mtr GI earth wire. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 15 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender