Road Transport and Highways Government Departments Closing in 16 days TDR #57395762

Tender For Construction Of Boundary Fencing & Development Of Gau Prashikahan Kendra Keshav Smarak Samiti In Continuation To Previously Sanctioned Project At Umrangso, District Dima Hasao Under Untied Fund For The Year 2025-26.

Issued by Government Departments · Dima Hasao, Assam
Tender Value
86.09 Lakhs
Estimated cost
Bid Submission
29 Sep 2026
16 days left
EMD
1.72 Lakhs
Bank guarantee accepted
Document Fee
1722
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dima Hasao → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Boundary Fencing & Development Of Gau Prashikahan Kendra Keshav Smarak Samiti In Continuation To Previously Sanctioned Project At Umrangso, District Dima Hasao Under Untied Fund For The Year 2025-26.

BOQ

Name of Work:- Construction of Boundary Fencing & Development of Gau Prashikahan Kendra Keshav Smarak Samiti in continuation to previously sanctioned Project at Umrangso, District Dima Hasao under Untied Fund for the year 2025-26.
Sl. No. Item Description
1Construction of Cow Shed2.8 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 : All kinds of soil.
216.12: Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
34.1 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :4.1.5A : 1:3:6 (1 Cement : 3 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) )
45.22 : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.1 : Mild steel and Medium Tensile steel bars.
55.22 : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.1 : Mild steel and Medium Tensile steel bars.
65.9 : Centering and shuttering including strutting, propping etc. and removal of form for.5.9.1 : Foundations, footings, bases of columns, etc. for mass concrete.
75.9.5 : Lintels, beams, plinth beams, girders, bressumers and cantilevers
85.9.6 : Columns, Pillars, Piers, Abutments, Posts and Struts
95.1 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level :5.1.3 : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)
105.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing andreinforcement :5.2.2 : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
116.1 : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.2 : Cement mortar 1:6 (1 cement : 6 coarse sand)
1210.16 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.16.2 : Hot finished seamless type tubes
1312.1 : Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheetscomplete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required.12.1.3 : 0.63 mm thick with zinc coating not less than 275 gm/ m²
1412.4 : Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I.limpet and bitumen washers complete.12.4.2 : 0.63 mm thick with zinc coating not less than 275 gm/m²
152.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
1611.5 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete.11.3.1 : 40 mm thick with 20 mm nominal size stone aggregate
174.17 : Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth.
186.12 : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :6.12.2 : Cement mortar 1:3 (1 cement : 3 coarse sand)
1913.2 : 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.1 : 1:4 (1 cement: 4 fine sand)
2013.42 : Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, ofrequired shade and colour complete, as per manufacturer's specification.13.42.1 : Two or more coats on new work
21Construction of RCC Water Reservoir2.8 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 : All kinds of soil.
224.1 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :4.1.5 : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
235.22 : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.1 : Mild steel and Medium Tensile steel bars.
245.9 : Centering and shuttering including strutting, propping etc. and removal of form for.5.9.2 :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
255.9.3 : Suspended floors, roofs, landings, balconies and access platform
265.1 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level :5.1.2 : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
275.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing andreinforcement :5.2.2 : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
2813.2 : 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.1 : 1:4 (1 cement: 4 fine sand)
2913.3 : 20 mm cement plaster of mix :13.3.1 : 1:4 (1 cement: 4 fine sand)
30Construction of Toilet2.8 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 : All kinds of soil.
3116.12: Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
324.1 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :4.1.5 : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
335.22 : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 : Thermo-Mechanically Treated bars of grade Fe-500D or more.
345.9 : Centering and shuttering including strutting, propping etc. and removal of form for.5.9.1 : Foundations, footings, bases of columns, etc. for mass concrete
355.9.5 : Lintels, beams, plinth beams, girders, bressumers and cantilevers
365.9.6 : Columns, Pillars, Piers, Abutments, Posts and Struts
375.1 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level :5.1.3 : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)
386.1 : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.1 : Cement mortar 1:4 (1 cement : 4 coarse sand)
396.13 : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floorV level.6.13.2 : Cement mortar 1:4 (1 cement :4 coarse sand)
4010.13 : Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing ofnecessary butt hinges and screws and applying a priming coat of approved steel primer.10.13.1 : Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
4110.5 : Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners,all necessary fittings complete, including applying a priming coat of approved steel primer.10.5.2 : Using flats 30x6mm for diagonal braces and central cross piece
4210.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
4312.1 : Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheetscomplete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required.12.1.3 : 0.63 mm thick with zinc coating not less than 275 gm/ m²
4413.2 : 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.1 : 1:4 (1 cement: 4 fine sand)
4511.5 : 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardenermix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’sspecifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
4613.3 : 20 mm cement plaster of mix :13.3.1 : 1:4 (1 cement: 4 fine sand)
4713.37 : White washing with lime to give an even shade :13.37.1 : New work (three or more coats)
4819.3 : Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standarddesign :19.3.3 : 200 mm diameter S.W. pipe
4919.32 : Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.19.32.1 : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
50Sanitary & Water Supply Works17.1 : Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required:17.1.1 : White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
5117.35 : Providing and fixing soil, waste and vent pipes :17.35.1 : 100 mm dia17.35.1.1 : Sand cast iron S&S pipe as per IS: 1729
5217.35.2 : 75 mm diameter :17.35.2.1 : Sand cast iron S&S pipe as per IS: 1729
5317.39 : Providing and fixing plain bend of required degree.17.39.1 : 100 mm dia17.39.1.1 : Sand cast iron S&S as per IS - 1729
5417.42 : Providing and fixing double equal plain junction of required degree.17.42.1 : 100x100x100x100 mm17.42.1.1 : Sand cast iron S&S as per IS - 1729
55Construction of Boundary Fencing2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 mabove ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
562.8 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 : All kinds of soil.
5716.12: Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
584.1 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :4.1.5 : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
595.9 : Centering and shuttering including strutting, propping etc. and removal of form for.5.9.5 : Lintels, beams, plinth beams, girders, bressumers and cantilevers
605.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing andreinforcement :5.2.2 : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
616.12 : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :6.12.1 :Cement mortar 1:3 (1 cement : 3 coarse sand)
6210.25 : Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.10.25.2 : In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
6316.70 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire ornuts, bolts and washers as required complete as per the direction of Engineer-in-charge.16.70.1 : Made of G.I. wire of dia 4 mm
6413.2 : 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.1 : 1:4 (1 cement: 4 fine sand)
65Construction of Hall2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 mabove ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
662.8 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 : All kinds of soil.
6716.12: Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
684.1 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :4.1.5 : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
695.22 : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.4 :Hot rolled deformed bars
705.9 : Centering and shuttering including strutting, propping etc. and removal of form for.5.9.1 : Foundations, footings, bases of columns, etc. for mass concrete
715.9.5 : Lintels, beams, plinth beams, girders, bressumers and cantilevers
725.9.6 : Columns, Pillars, Piers, Abutments, Posts and Struts
735.1 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level :5.1.3 : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)
745.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing andreinforcement :5.2.2 : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
756.1 : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.2 : Cement mortar 1:6 (1 cement : 6 coarse sand)
769.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fastlugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.3 : Kiln seasoned and chemically treated hollock wood
7710.13 : Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing ofnecessary butt hinges and screws and applying a priming coat of approved steel primer.10.13.1 : Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
7821.3 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):21.3.3 : With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
799.20 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.9.20.1 : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
806.8 : Brick work 7 cm thick with common burnt clay F.P.S. (non modular) brick of class designation 7.5 in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure above plinth level and upto floor five level.
8110.16 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.16.2 : Hot finished seamless type tubes
8212.1 : Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheetscomplete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.12.1.3 : 0.63 mm thick with zinc coating not less than 275 gm/ m²
8312.4 : Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I.limpet and bitumen washers complete.12.4.2 : 0.63 mm thick with zinc coating not less than 275 gm/m²
842.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
8511.3 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete11.3.1 : 40 mm thick with 20 mm nominal size stone aggregate
8612.24 : Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) :12.24.1 : Natural colour insulating board12.24.1.1 : 12 mm thick
8713.2 : 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.2 : 1:6 (1 cement: 6 fine sand)
8813.9 : Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.13.9.1 : 12 mm cement plaster
8913.42 : Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, ofrequired shade and colour complete, as per anufacturer's specification.13.42.1 : Two or more coats on new work
9013.50 : Applying priming coat:13.50.2 : With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood
9113.61 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :13.61.1 : Two or more coats on new work
929.96 :Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :9.96.1 : 300x16 mm
939.97 : Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete :9.97.1 : 300x10 mm
949.100 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyedto required colour or shade, with necessary screws etc. complete :9.100.1 : 125 mm
9519.3 : Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standarddesign :19.3.3 : 200 mm diameter S.W. pipe
96Store Room2.8 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 : All kinds of soil.
974.1 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :4.1.5B : 1:3:6 (1 cement : 3 manufactured sand derived from Recycled concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm nominal size Recycled Aggregate (RA) )
985.22 : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.1 : Mild steel and Medium Tensile steel bars
995.9 : Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 : Foundations, footings, bases of columns, etc. for mass concrete
1005.9.5 : Lintels, beams, plinth beams, girders, bressumers and cantilevers
1015.9.6 : Columns, Pillars, Piers, Abutments, Posts and Struts
1025.1 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level :5.1.3A : 1:2:4 (1 cement : 2 coarse sand incuding manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 4 graded stone aggregate 20 mm nominal size of Recycled Con crete Aggregate (RCA) upto 20%).
1035.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of entering, shuttering, finishing and reinforcement :5.2.2A : 1:1.5:3 (1 cement : 1.5 coarse sand incuding manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) upto 20%
1046.1 : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.2 : Cement mortar 1:6 (1 cement : 6 coarse sand)
1056.8 : Brick work 7 cm thick with common burnt clay F.P.S. (non modular) brick of class designation 7.5 in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure above plinth level and upto floor five level.
10610.16 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.16.1 : Hot finished welded type tubes
10712.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
10812.51 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :12.51.1 : Ridges plain (500 - 600mm)
1092.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
11011.3 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete.11.3.1 : 40 mm thick with 20 mm nominal size stone aggregate
11112.26 : Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceilingetc. complete (frame work to be paid seperatately).12.26.2 : 6 mm thick Cement bonded wood particle board as per IS:14276
11210.31 : Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred andwelded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessarybutt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
1139.21 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters: 9.21.3 : 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws
11410.10 : Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metalsash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost.10.10.2 : Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately).
11513.4 : 12mm cement plaster of mix.13.4.1 : 1:6 (1 cement: 6 coarse sand).
11613.9 : Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.13.9.1 : 12mm cement plaster.
11713.81 : Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.13.81.2 : Two coats.
11813.50 : Applying priming coat.13.50.1 : With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood).
11913.63 : Painting with aluminium paint of approved brand and manufacture to give an even shade.13.63.1 : Two or more coats on new work.
1209.96 : Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete.9.96.1 : 300 x 16mm.
1219.100 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete.9.100.1 : 125mm.
122Construction of Gau Palok Quarter2.8 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.2.8.1 : All kinds of soil.
12311.2 : Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
1244.1 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.5A : 1:3:6 (1 Cement : 3 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 6 graded stone aggregate 20mm nominal size Recycled Concrete Aggregate (RCA).
1255.22 : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22.1 : Mild steel and Medium Tensile steel bars.
1265.9 : Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 : Foundations, footings, bases of columns, etc. for mass concrete.
1275.9.5 : Lintels, beams, plinth beams, girders, bressumers and cantilevers
1285.9.6 : Columns, Pillars, Piers, Abutments, Posts and Struts
1295.1 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.5.1.2 : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources).
1305.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.5.2.2 : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources).
1316.1 : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in.6.1.1 : Cement mortar 1:4 (1 cement : 4 coarse sand).
1326.12 : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in.6.12.2 : Cement mortar 1:4 (1 cement :4 coarse sand).
1339.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.3 : Kiln seasoned and chemically treated hollock wood.
1349.20 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.9.20.1 : 35mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
13510.11 : Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).10.11.1 : Fixing with 15 x 3mm lugs 10 cm long embedded in cement concrete block 15 x 10 x 10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
13610.30 : Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with.1030.1 : 4.0mm thick glass panes.
13710.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
13812.1 : Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.12.1.3 : 0.63mm thick with zinc coating not less than 275 gm/m².
13912.4 : Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete.12.4.2 : 0.63mm thick with zinc coating not less than 275 gm/m².
14012.24 : Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately).12.24.1 : Natural colour insulating board.12.24.1.1 : 12mm thick.
14111.4 : 52mm thick cement concrete flooring with concrete hardener topping, under layer 40mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
1429.48 : Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.9.48.1 : Fixed to steel windows by welding.
14313.2 : 15mm cement plaster on the rough side of single or half brick wall of mix.13.2.1 : 1:4 (1 cement: 4 fine sand).
14413.41 : Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.13.41.1 : New work (two or more coats) over and including water thinnable priming coat with cement primer.
1459.96 : Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete.9.96.1 : 300 x 16mm.
1469.97 : Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete.9.97.1 : 300 x 10mm.
1479.100 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete.9.100.1 : 125mm.
14813.5 : Applying priming coat.13.50.1 : With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood).
14913.48 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications.13.48.3 : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture.
15013.48 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications.13.48.3 : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
1514.17A : Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm nominal size (Recycled Concrete Aggregate (RCA) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
15219.3 : Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design.19.3.3 : 200mm diameter S.W. pipe.
15313.3 : 20mm cement plaster of mix :13.3.1 : 1:4 (1 cement: 4 fine sand).
154Sanitary & Water Supply Works17.7 : Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.17.1.1 : White Vitreous china Orissa pattern W.C. pan of size 580 x 440mm with integral type foot rests.
15517.35 : Providing and fixing soil, waste and vent pipes.17.35.1 : 100mm dia.17.35.1.1 : Sand cast iron S&S pipe as per IS: 1729.
15617.35.2 : 75mm diameter.17.35.2.1 : Sand cast iron S&S pipe as per IS: 1729.
15717.39 : Providing and fixing plain bend of required degree.17.39.1 : 100mm dia.17.39.1.1 : Sand cast iron S&S as per IS - 1729.
15817.42 : Providing and fixing double equal plain junction of required degree.17.42.1 : 100 x 100 x 100 x 100mm.17.42.1.1 : Sand cast iron S&S as per IS - 1729.
15918.15 : Providing and fixing brass bib cock of approved quality.18.15.1 : 15 mm nominal bore.
16018.16 : Providing and fixing brass stop cock of approved quality.18.16.1 : 15 mm nominal bore.
16118.9 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.18.9.5 : 40mm nominal dia Pipes.
16218.9.3 : 25 mm nominal dia Pipes.
16318.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
164Compound Development and Levelling2.2 : Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m :.2.2.1 : All kinds of soil.
165Construction of Gate2.8 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.2.8.1 : All kinds of soil.
16616.11 : Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete.
1674.1 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.5 : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20mm nominal size derived from natural sources).
1685.22 : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level5.22.6 : Thermo-Mechanically Treated bars of grade Fe-500D or more.
1695.9 : Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 : Foundations, footings, bases of columns, etc. for mass concrete
1705.9.5 : Lintels, beams, plinth beams, girders, bressumers and cantilevers
1715.9.6 : Columns, Pillars, Piers, Abutments, Posts and Struts
1725.9.3 : Suspended floors, roofs, landings, balconies and access platform.
1735.3 : Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources).
17413.2 : 15mm cement plaster on the rough side of single or half brick wall of mix.13.2.1 : 1:4 (1 cement: 4 fine sand).
17510.25 : Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.10.25.2 : In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
17613.18 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
17713.43 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.13.43.1 : Water thinnable cement primer.
17813.45 : Finishing walls with textured exterior paint of required shade.13.45.1 : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.
17913.48 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications.13.48.3 : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
180Construction of Boundary Wallx2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.
1812.8 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.2.8.1 : All kinds of soil.
18216.11 : Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete.
1835.22A : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22.1 : Mild steel and Medium Tensile steel bars.
1845.9 : Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 : Foundations, footings, bases of columns, etc. for mass concrete.
1855.9.5 : Lintels, beams, plinth beams, girders, bressumers and cantilevers
1865.9.6 : Columns, Pillars, Piers, Abutments, Posts and Struts
1875.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.5.2.2 : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources).
1886.13 : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 : Cement mortar 1:4 (1 cement :4 coarse sand).
18913.2 : 15mm cement plaster on the rough side of single or half brick wall of mix.13.2.1 : 1:4 (1 cement: 4 fine sand).
19013.39 : Colour washing such as green, blue or buff to give an even shade :13.39.1 : New work (two or more coats) with a base coat of white washing with lime.
19110.25 : Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.10.25.2 : In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
19216.18 : Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used.16.18.1 : 250mm diameter S.W. pipe.
193Construction of Hall (Electrical works)1.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.1.1.1 : Group A
1941.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.1.1.2 : Group B
1951.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.1.1.3 : Group C
1961.12 : Wiring for light/power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed mudium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
1971.29 : Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLS including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.
1981.30 : Supplying and fixing metal box of 180mmx100x60mm deep (Nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
1991.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/wooden block including connection etc. as required.
2001.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.1.7.1 : 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2011.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.1.7.2 : 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2021.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.1.7.3 : 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2031.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.1.7.4 : 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2041.33 : Supplying and fixing brass batten/angle holder including connection etc. as required.
205NS-1 : Supplying fitting & fixing of 20 W LED LAMP HAVELS MAKE in he exising lamp holder as specified and directed by the deparment.
2062.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)2.3.1 : 6 way, Double door
2072.10 : Supplying and fixing 5 Amps to 32 Amps rating, Single pole 24/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2082.12 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. As required.2.12.1 : 40 Amps
20919.1 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceilling fan with Brush Less Direct Current (BLDC) Motor, class of insulaion: B, 3 Nos. blades, 30 cm long down rod, 2 Nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remoe or elecronic regulaor unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz single phase AC Supply, earthing etc. complete as required.
2101.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
2115.1 : Earthing withG.I. earth pipe 4.5 meter long, 40mm dia in including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/coke and salt) as required.
2125.18 : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required.
213Construction of Gau Palok Quarter (Electrical works)1.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.1.1.1 : Group A
2141.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.1.1.2 : Group B
2151.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.1.1.3 : Group C
2161.12 : Wiring for light/power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed mudium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
2171.29 : Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLS including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.
2181.30 : Supplying and fixing metal box of 180mmx100x60mm deep (Nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
2191.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/wooden block including connection etc. as required.
22011.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required..7.1 : 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2211.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.1.7.2 : 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2221.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.1.7.3 : 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2231.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.1.7.4 : 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2241.33 : Supplying and fixing brass batten/angle holder including connection etc. as required.
225NS-1 : Supplying fitting & fixing of 20 W LED LAMP HAVELS MAKE in he exising lamp holder as specified and directed by the deparment.
2262.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)2.3.1 : 6 way, Double door
2272.10 : Supplying and fixing 5 Amps to 32 Amps rating, Single pole 24/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2282.12 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. As required.2.12.1 : 40 Amps
22919.1 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceilling fan with Brush Less Direct Current (BLDC) Motor, class of insulaion: B, 3 Nos. blades, 30 cm long down rod, 2 Nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remoe or elecronic regulaor unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz single phase AC Supply, earthing etc. complete as required.
2301.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
2315.1 : Earthing withG.I. earth pipe 4.5 meter long, 40mm dia in including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/coke and salt) as required.
2325.18 : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required.
2331Electrical Works (Fan Fittings and External Works).1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.1.1.1 : Group A
234.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.1.1.2 : Group B
235.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.1.1.3 : Group C
2361.12 : Wiring for light/power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed mudium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
2371.29 : Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLS including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.
2381.30 : Supplying and fixing metal box of 180mmx100x60mm deep (Nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
2391.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/wooden block including connection etc. as required.
2401.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.1.7.1 : 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2411.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.1.7.2 : 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2421.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.1.7.3 : 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2431.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.1.7.4 : 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2441.33 : Supplying and fixing brass batten/angle holder including connection etc. as required.
245NS-1 : Supplying fitting & fixing of 20 W LED LAMP HAVELS MAKE in he exising lamp holder as specified and directed by the deparment.
2462.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)2.3.1 : 6 way, Double door
2472.10 : Supplying and fixing 5 Amps to 32 Amps rating, Single pole 24/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2482.12 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. As required.2.12.1 : 40 Amps
24919.1 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceilling fan with Brush Less Direct Current (BLDC) Motor, class of insulaion: B, 3 Nos. blades, 30 cm long down rod, 2 Nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remoe or elecronic regulaor unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz single phase AC Supply, earthing etc. complete as required.
2501.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
2515.1 : Earthing withG.I. earth pipe 4.5 meter long, 40mm dia in including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/coke and salt) as required.
2525.18 : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required. Please Enable Macros to View BoQ information
2535.18 : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57395762
AUTHORITY Government Departments
TENDER VALUE 86.09 Lakhs
LAST DATE 29-09-2026
Authority
Authority Name Public Works Roads Department
Work Description Tender for Construction Of Boundary Fencing & Development Of Gau Prashikahan Kendra Keshav Smarak Samiti In Continuation To Previously Sanctioned Project At Umrangso, District Dima Hasao Under Untied Fund For The Year 2025-26.
Basic Detail
Tender No CS-5/09/2026-27/05
Bidding Type Tender
Location
City Dima Hasao
State Assam
Key Dates
Publish Date 08 Sep 2026
Submission Date 29 Sep 2026
Open Date 30 Sep 2026
Finance
Tender Value 86.09 Lakhs
Tender Fee 1722
EMD 1.72 Lakhs
Exemption Available
Document List
BOQ_84595.xls
e72ae479-90c1-4353-8e8c-1a852d464554.html
Tendernotice_1 (24).pdf
Tendernotice_2 (4).pdf
Tendernotice_3 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Sep 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_84595.xls

html

e72ae479-90c1-4353-8e8c-1a852d464554.html

pdf

Tendernotice_1 (24).pdf

pdf

Tendernotice_2 (4).pdf

pdf

Tendernotice_3 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail