Tender For Structural Rehabilitation Measures, Basic Facilities Improvement Works At Perch Dam, Distt. S.A.S. Nagar, Punjab Under Drip Project

Issued by Government Departments · S.a.s Nagar, Punjab
Tender Value
83.12 Lakhs
Estimated cost
Bid Submission
07 Oct 2026
22 days left
EMD
1.66 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
S.a.s Nagar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Structural Rehabilitation Measures, Basic Facilities Improvement Works At Perch Dam, Distt. S.A.S. Nagar, Punjab Under Drip Project

BOQ

Name of Work:- Structural Rehabilitation Measures, Basic Facilities Improvement Works at PERCH DAM, Distt. S.A.S. Nagar, Punjab under DRIP Project
Sl. No. Item Description
1Stripping and stacking iron sheets of a roof including ridging, flashing, eaves boards gutters and down pipes. Add for roof trusses of iron or wood, (rafters, purling etc.)
2Dismantling cement conglomerate floors 25mm to50mm thick including concrete base.
3Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
4Cement concrete 1:4:8 with stone aggregate 40mmgauge. mixing by mechanical means using concrete mixer volumetric type
5Cement concrete 1:2:4, with stone balast, mixing by mechanical means using concrete mixer volumetrictype.
6First class burnt brick work laid in cement sand mortar1:6 in foundation and plinth.
7First class 225mm thick honey-comb burnt brick worklaid in cement sand mortar 1:4
8First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
9First class burnt brick work laid in cement sand mortar1:6 in second storey upto 4 metres above the top of structural roof of lower storey.
10Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufacturesguidelines.
11115mm thick brick wall in cement sand mortar 1:4without reinforcement in superstructure
12Centring and shuttering for sides and soffits of beam,beams launchings girders bressumers, lintels.
13Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
14Reinforced cement concrete M-25 mechenically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering insuperstructure.
15Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundationand plinth.
16Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering insuperstructure.
17Cold twisted deformed (Ribbed/Tor Steel Bar) Bars Fe500 grade as per IS 1786-2008 for R.C.C. works, where not including in the complete rate of R.C.C. including bending and placing in position complete in all respect.
1812.5 mm thick cement plaster 1:4.
1920mm thick cement plaster 1:4 in two coat work.
20Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying twocoats to get required finish.
21Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats overone priming coat to give an even shade.
22Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
23Finishing walls with acrylic smooth exterior paint of required shade with two coats applied @ 1.67 litre/10sqm over and including base coat of waterproofing Cement Paint applied @ 2.20 Kg/10 sqm
24Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction ofthe Engineer-in-charge.
25Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc.
26Laying of Dry Brick Ballast 40 mm gauge for flooring.
27Brick Bats
28Base course of floor consisting of 100 mm thick cement concrete 1:8:16 with stone aggrigate 40 mm gauge and 100 mm fine sand filling using mechanicalmixer for mixing of material.
29Providing and laying vitrified floor tiles 600x600mm size premium quality, manufactured using Soluble Salt Technology, with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 fine sand ) for new flooring laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per sqm of tile area in average 3mm thickness over existing base etc.,complete
30Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed withpigment of matching shade complete.
31Supply & Fixing of pressed steel frames (Chowkats) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section(standard design latest) including iron lugs (hold fasts) iron hinges, confirming to P.W.D. specifications including bolts for fixing stops, lock-notch provision for receiving tower bolts, Hydraulic spring and finished with one priming coat of approved quality, fixed in position, including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete. Doors and windows frame of size 151mm x 60mm with 35 mm widedouble rebate weighing 3.95 kg per meter
32Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. Panelled, glazed or glazedand panelled (Double leaf), 40mm thick.
33Wire gauge Hollock wood door shutter without springshoused in chowkhat. 35 mm Thick
34Providing and fixing hydraulic door closer ISI markwith necessary screw etc. complete. I.S.I Designation No. II (size of door 701mm to 850mm).
35Providing & Fixing in position C.P./Aluminium Khunti with 6 pegs of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect
36Providing and fixing 6” stainless steel handles ISImarked on door & window frames complete in all respect as directions of Engineer – in Charge
37Providing and fixing 6” stainless steel bolts ISI marked on door & window frames complete in all respect asdirections of Engineer – in Charge
38Applying pink primer or aluminum priming coat on wood work including preparation of surface knottingand stopping etc.
39Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti includingfinishing the surface to required finish complete.
40Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an evenshade.
41Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shadeincluding rubbing down old paint.
42Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cementconcrete 1:8:16.
43Bottom Khurra on ground 1.2m x 0.6m consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thickcement plaster 1:3.
44Embedding 100mm dia CI rain water non pressure ISI mark pipe in cement mortar during masonry work.
45Providing and fixing cast iron shoe for rain water pipe on wooden plugs fixed on wall face including filling the joints with spun yarn and cement mortar 1:2.
46RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiringfan point with fan box in PVC insulated copper conductor single core FR cable (ISI marked) overall1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface). :-Wiring fan point (With fan box)
47RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring6Amp. wall socket point in PVC insulated copper conductor single core FR cable (ISI marked) overall1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface). :-Wiring light point
48RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring 3pin 6 Amp. wall socket (Shuttered) point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 11⁄2\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring 6Amp. wall socket point.
49RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 11⁄2\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring 16/20Amp. power plug control point.
50Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 2.5sq.mm (Un-sheathed)
51Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 4sq.mm (Un-sheathed).
52XLPE INSULATED UN-ARMOURED CABLES(LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 10sq.mm (4Core) Un-armoured (Loose)
53Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double Walled Corrugated HDPE Pipe 120/103.5mm (Outer/ Inner dia.)
54Cement Concrete 1:3:6 around pipe for protection. With stone ballast and mixing by mixing by mechanical means using concrete mixer volumetrictype
55Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-a) Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity (without cistern fitting) size 62x37x67 cm with P trap or S trap and seat cover complete in all respect.
56Providing and fixing jet spray with 2'-6\\" long PVCpipe. With C.P. Brass nut
57Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge) fixed into wall with rawl plugs and C.P brass screwscomplete in all respect
58Providing and fixing in position paper holders ofapproved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect. (a) C.P. brass toilet paper holder.
59Providing and fixing in position Acrylic towel Rails size 20mm dia 600mm long of approved make (to the approval of Engineer-in-charge) fixed in with rawl plugs embedded in walls with brass screws complete inall respect.
60Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tapcomplete in all respect. Size 450mmx300mm.
61Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 110mm o/d single socket SWR UPVCpipe lines laid complete.
62Providing and fixing in position single socket SWR UPVC soil waste or anti syphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type A, 75mm o/d single socket SWR UPVC pipe lines laid complete
63Providing and fixing in position single socket SWR UPVC soil waste or anti syphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type A, 160mm o/d single socket SWR UPVC pipe lines laid complete.
64CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. SDR 11 CPVC pipes & fittings 20mm o/d.
65CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.CPVC SDR 11 Pipe & fitting 25mm o/d.
66Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. 25mm i/d G.I.Union.
67Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
68Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. C.P. Brass extensionpiece, 25mm long to 50mm long
69Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect.
70Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge)complete in all respect. C.P. brass Bib cock long nose/long body foam flow without flange.
71Providing and fixing in position 15mm C.P. Pillar cockfoam flow of approved make (to the approval of Engineer-in-charge).
72Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P.brass 15mmAngle valve without flange.
73Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 600 mm with C.P. Brassnut.
74Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick, grade-304 (18/8) with waste coupling complete in all respect (Rectangular Sink with Deluxe Border Single Bowl Overall Size 555 mm x 475mm x200 mm).
75Providing and fixing H.C.I. Floor traps conforming toI.S.I. Specification of reputed firm of the self cleaning design with S.S. grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors,etc. With 100mm x 75mm i/d Floor Trap (weighing 4.0 Kg).
76Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber. (CSR Item No 30.99 (c)) 150mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size330mm x 330mm
77Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty doubleseal
78Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. TrippleLayer Tanks
79Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and PlasticBall , 25mm i/d
80Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) Size600mmx450mm
81SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc: -SP&N Double Door Distribution Board 16 way each.
82MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs: - (vii) MCB Double Pole 40amp. (10kA, Curve-C)
83MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder, facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs: - (ii) MCB Single Pole 6-32amp. (10kA, Curve-C)
84SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.,:- Ceiling Rose (Flush Piano type).
85SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.,:- Bakelite Batten Holder (Large size).
86Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect b) Glazing area above 0.09 sqm, 4mm thick or 10.78 Kg/ sqm.
87Providing and fixing in Each position G.I. Tank Nipple ofapproved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect (C) G.I. tank nipple 25mm i/d.
88Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts,screws, welding rod complete fixing in position.
89Steel work fixed independently without connecting plates including cutting hoisting and fixing in positionfor Tees angles & channels
90Applying priming coat with metal primer on new steelor iron work i/c preperation of surface.
91Supply of Ceiling Fan 1200 mm.
92Erection of ceiling/cabin/exhaust fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) Cable 0.75 sqmmComplete. For Celing Fan
93Supply of Exhaust Fan, Warranty 36 months.
94Erection of ceiling/cabin/exhaust fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) Cable 0.75 sqmmComplete. Erection of Exhaust fan
95Supply of LED Batten 20 Watt, 1150 mm
96Supply of LED bulb 12 watt.
97Supply of 30 Watt Flood Light
98Erection of light fixtures on wall /ceiling having connection with PVC insulated PVC sheathed two single core copper conductor (FR) Cable 0.75 sqmm Complete. Erection of 1x20/28/36/40W Box Type(LED/ Fluorescent) light fixture
99Boring with casing pipe for tube well in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested, equipment as required such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect (a) Boring with 150mm idHousing Pipe. As per CSR Item No 28.72 (a)
100Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer incharge. (a) 100 mm nominal size dia. As per CSR Item No 28.92 (a)
101Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge . (a) 100 mm nominal size dia. Asper CSR Item No 28.93 (a)
102Providing, Laying, fixing & jointing of ISI MarkedH.D.P.E. Pipes as per ISI - 4984-1995 casting along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. H.D.P.E pipe of 10 Kg. PE-80, 40 mm o/d.
103Supply & erection of electrically driven water lubricated submersible pumping set should strictly confirm to ISI:8034-1976 with latest amendments, directly coupled with Submersible electric motor capable to delivering 12000 Litres of water per hour against a head of 280 ft (3.7 kilowatt).
104Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size4.0sq.mm (56/0.3mm), 3Core
105Supply and fixing of bail plug of MS Pipe complete with inverted U-hook attached to the bottom plug complete in all respect. 100mm internal diameter(weight 14.5 kg per metre) 5.40 mm thickness
106Supply and fixing of well cap having thread to fix onhousing pipe complete in all respect. 100mm internal diameter
107Providing and fixing of STARTER, MAIN SWITCH/MCCB 32 AMP along with wiring etc. in cubical pillar box type panel board complete in allrespects.
108Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect . As per CSR ItemNo 28.77
1093-STEPPED STEEL TUBULAR POLE: Supply and erection of 3-Stepped steel tubular swaged and welded pole (410-SPMpa) of suitable length confirming to IS: 2713- (PART-II)-1980 (Steel tubes confirming to IS: 1161-1979, UTS 42 kgf/Sq.mm) to fix up to a required planting depth below ground level in a hole of excavation about 45 cm dia. and suitable depth to fill up to 15 cm below G/L with 1:2:4 cement concrete mixture including painting of pole with two coats of approved aluminium paint as required: -Overall length 7 metre, with planting depth 1.25 metre, length of sections 4 metre, 1.5 metre and 1.5 metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 114.3mm x 4.5mm, 88.9mm x 4.05mm and 76.1mm x 3.25mm (Bottom, Middle and Top respectively) with approximate weight 73 kg. (410 SP-2) and base Plate weight 7.5 kg. of size 12mm thick about 30 cm dia.
110Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. Water Cooler Full Steel Body40/80 ltr Capacity without Stablizer
111Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge) including carriage and fixing in position completein all respect.
112Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M-35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge.
113Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&Hspecifications.
114Dismantling metalling or dry brick ballast
115Relaying of recovered material obtain from dismantling of road crust as Construction of granular sub-base by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MORD technicalspecifications
116Providing, laying, spreading and compactingstone aggregates of Grading II to water boundmacadam specification including spreading inuniform thickness, hand packing, rolling withsmooth wheeled roller 8-10 tonnes in stages toproper grade and camber, applying and broomingrequisite type of binding Materials to fill up theinterstices of coarse aggregate, watering andcompacting to the required density complete aspertechnical specifications
117Providing and laying surface dressing in singlecoat using crushed stone aggregates of specifiedsize on a layer of bituminous binder VG-10 @ 1kgper sqm laid on prepared surface after cleaningthe road surface and rolling with 8-10 tonnesmooth wheeled steel roller complete as pertechnical clause 509 of MORT&Hspecifications
118Providing and applying tack coat with penetration grade bitumen VG-10 using bitumen pressure distributor at the rate of 0.40 kg per sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete asper technical specifications
119Providing, laying and compaction of open - graded premix surfacing of 20 mm thickness consisting ofcrushed stone aggregates of specified gradingpremixed in a Continuous type hot mix plant withbituminous binder VG-10 @ 1.46kg per sqm, laidwith Paver Finisher Mechanical and rolling with asmooth wheeled roller 8-10 tonne capacity,finished to required level and grades complete asper technicalclause 510 of MORT&H specification
120Providing and laying of premix sand seal coat premixed in Continuous type hot mix plant usingspecified fine aggregates and penetration gradebitumen VG-10 @ 0.68kg per sqm, laid to thespecified levels, grade and cross fall complete asper technical clause 511 of MORT&Hspecification
121Boulder masonry in cement mortar (1:6) in foundationsand plinth.
122Providing and fixing stair case railing made out of MS Square bars 20x 20 mm as vertical Cost 0.70 m high fixed with MS Base Plate of 40mmx40mmx6mm and flat iron 40mmx 6mm as hand rail complete in allrespect
123Place Identification sign board 900x600mm rectangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012 fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on two square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012. (a) Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012.
124Definition Plate 600x200mm rectangular as per as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. specifications. Fixed over 3mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame welded with vertical post of sign board complete as per clause 801 of MORT&Hspecifications. Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012. (a) Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 495609 and as per IRC 67 2012.
125Supply and Installation of 10 Kw Hybrid Grid tied Solar Power Plant with Batteries at Dam Site Complete in all respect as per Instructions of Engineer- in -Charge.
126Corrugated G.I. Sheet roofing 0.80 mm thick fixed with galvanized iron J or L hooks 10mm dia, G.I. Limpot and bitumen washers complete excluding thecost of purling rafters and trusses
127Cement pointing 1:2 deep variety.
128Surface Monitoring Points, Ground Settlement marker for monitering vertical settlement on the surface of embankment and soil mass etc. It comprise of a 2 m long x 16 mm dia SS-304 survey pin having a hemicpherical top and a MS grouting plate of 150 mm dia, 5 mm thickness. A red colored cross mark isprovided at its top.
129Providing Non-recording Rain Gauge Conforming toIS: 5225 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57395676
AUTHORITY Government Departments
TENDER VALUE 83.12 Lakhs
LAST DATE 07-10-2026
Authority
Authority Name Water Resources Department
Work Description Tender for Structural Rehabilitation Measures, Basic Facilities Improvement Works At Perch Dam, Distt. S.A.S. Nagar, Punjab Under Drip Project
Basic Detail
Tender No 3
Bidding Type Tender
Location
City S.a.s Nagar
State Punjab
Key Dates
Publish Date 07 Sep 2026
Submission Date 07 Oct 2026
Open Date 07 Oct 2026
Finance
Tender Value 83.12 Lakhs
Tender Fee 1000
EMD 1.66 Lakhs
Exemption Available
Document List
98bba880-1098-4523-8c60-8f0f6f5c3a21.html
BOQ_356034.xls
Tendernotice_1 (19).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 22 days
Oct 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

98bba880-1098-4523-8c60-8f0f6f5c3a21.html

xls

BOQ_356034.xls

pdf

Tendernotice_1 (19).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders